PIFON-EPT: MR-Based Electrical Property Tomography Using Physics-Informed Fourier Networks
Authors:
Xinling Yu,
José E. C. Serrallés,
Ilias I. Giannakopoulos,
Ziyue Liu,
Luca Daniel,
Riccardo Lattanzi,
Zheng Zhang
Abstract:
We propose Physics-Informed Fourier Networks for Electrical Properties (EP) Tomography (PIFON-EPT), a novel deep learning-based method for EP reconstruction using noisy and/or incomplete magnetic resonance (MR) measurements. Our approach leverages the Helmholtz equation to constrain two networks, responsible for the denoising and completion of the transmit fields, and the estimation of the object'…
▽ More
We propose Physics-Informed Fourier Networks for Electrical Properties (EP) Tomography (PIFON-EPT), a novel deep learning-based method for EP reconstruction using noisy and/or incomplete magnetic resonance (MR) measurements. Our approach leverages the Helmholtz equation to constrain two networks, responsible for the denoising and completion of the transmit fields, and the estimation of the object's EP, respectively. We embed a random Fourier features map** into our networks to enable efficient learning of high-frequency details encoded in the transmit fields. We demonstrated the efficacy of PIFON-EPT through several simulated experiments at 3 and 7 tesla (T) MR imaging, and showed that our method can reconstruct physically consistent EP and transmit fields. Specifically, when only $20\%$ of the noisy measured fields were used as inputs, PIFON-EPT reconstructed the EP of a phantom with $\leq 5\%$ error, and denoised and completed the measurements with $\leq 1\%$ error. Additionally, we adapted PIFON-EPT to solve the generalized Helmholtz equation that accounts for gradients of EP between inhomogeneities. This yielded improved results at interfaces between different materials without explicit knowledge of boundary conditions. PIFON-EPT is the first method that can simultaneously reconstruct EP and transmit fields from incomplete noisy MR measurements, providing new opportunities for EPT research.
△ Less
Submitted 20 December, 2023; v1 submitted 23 February, 2023;
originally announced February 2023.
-
MR-Based Electrical Property Reconstruction Using Physics-Informed Neural Networks
Authors:
Xinling Yu,
José E. C. Serrallés,
Ilias I. Giannakopoulos,
Ziyue Liu,
Luca Daniel,
Riccardo Lattanzi,
Zheng Zhang
Abstract:
Electrical properties (EP), namely permittivity and electric conductivity, dictate the interactions between electromagnetic waves and biological tissue. EP can be potential biomarkers for pathology characterization, such as cancer, and improve therapeutic modalities, such radiofrequency hyperthermia and ablation. MR-based electrical properties tomography (MR-EPT) uses MR measurements to reconstruc…
▽ More
Electrical properties (EP), namely permittivity and electric conductivity, dictate the interactions between electromagnetic waves and biological tissue. EP can be potential biomarkers for pathology characterization, such as cancer, and improve therapeutic modalities, such radiofrequency hyperthermia and ablation. MR-based electrical properties tomography (MR-EPT) uses MR measurements to reconstruct the EP maps. Using the homogeneous Helmholtz equation, EP can be directly computed through calculations of second order spatial derivatives of the measured magnetic transmit or receive fields $(B_{1}^{+}, B_{1}^{-})$. However, the numerical approximation of derivatives leads to noise amplifications in the measurements and thus erroneous reconstructions. Recently, a noise-robust supervised learning-based method (DL-EPT) was introduced for EP reconstruction. However, the pattern-matching nature of such network does not allow it to generalize for new samples since the network's training is done on a limited number of simulated data. In this work, we leverage recent developments on physics-informed deep learning to solve the Helmholtz equation for the EP reconstruction. We develop deep neural network (NN) algorithms that are constrained by the Helmholtz equation to effectively de-noise the $B_{1}^{+}$ measurements and reconstruct EP directly at an arbitrarily high spatial resolution without requiring any known $B_{1}^{+}$ and EP distribution pairs.
△ Less
Submitted 22 October, 2022;
originally announced October 2022.
-
A hybrid volume-surface integral equation method for rapid electromagnetic simulations in MRI
Authors:
Ilias I. Giannakopoulos,
Georgy D. Guryev,
José E. C. Serrallés,
Jan Paška,
Bei Zhang,
Luca Daniel,
Jacob K. White,
Christopher M. Collins,
Riccardo Lattanzi
Abstract:
Objective: We developed a hybrid volume surface integral equation (VSIE) method based on domain decomposition to perform fast and accurate magnetic resonance imaging (MRI) simulations that include both remote and local conductive elements. Methods: We separated the conductive surfaces present in MRI setups into two domains and optimized electromagnetic (EM) modeling for each case. Specifically, in…
▽ More
Objective: We developed a hybrid volume surface integral equation (VSIE) method based on domain decomposition to perform fast and accurate magnetic resonance imaging (MRI) simulations that include both remote and local conductive elements. Methods: We separated the conductive surfaces present in MRI setups into two domains and optimized electromagnetic (EM) modeling for each case. Specifically, interactions between the body and EM waves originating from local radiofrequency (RF) coils were modeled with the precorrected fast Fourier transform, whereas the interactions with remote conductive surfaces (RF shield, scanner bore) were modeled with a novel cross tensor train-based algorithm. We compared the hybrid- VSIE with other VSIE methods for realistic MRI simulation setups. Results: The hybrid-VSIE was the only practical method for simulation using 1 mm voxel isotropic resolution (VIR). For 2 mm VIR, our method could be solved at least 23 times faster and required 760 times lower memory than traditional VSIE methods. Conclusion: The hybrid-VSIE demonstrated a marked improvement in terms of convergence times of the numerical EM simulation compared to traditional approaches in multiple realistic MRI scenarios. Significance: The efficiency of the novel hybrid-VSIE method could enable rapid simulations of complex and comprehensive MRI setups.
△ Less
Submitted 22 June, 2022;
originally announced June 2022.
-
Compression of volume-surface integral equation matrices via Tucker decomposition for magnetic resonance applications
Authors:
Ilias I. Giannakopoulos,
Georgy D. Guryev,
Jose E. C. Serralles,
Ioannis P. Georgakis,
Luca Daniel,
Jacob K. White,
Riccardo Lattanzi
Abstract:
In this work, we propose a method for the compression of the coupling matrix in volume\hyp surface integral equation (VSIE) formulations. VSIE methods are used for electromagnetic analysis in magnetic resonance imaging (MRI) applications, for which the coupling matrix models the interactions between the coil and the body. We showed that these effects can be represented as independent interactions…
▽ More
In this work, we propose a method for the compression of the coupling matrix in volume\hyp surface integral equation (VSIE) formulations. VSIE methods are used for electromagnetic analysis in magnetic resonance imaging (MRI) applications, for which the coupling matrix models the interactions between the coil and the body. We showed that these effects can be represented as independent interactions between remote elements in 3D tensor formats, and subsequently decomposed with the Tucker model. Our method can work in tandem with the adaptive cross approximation technique to provide fast solutions of VSIE problems. We demonstrated that our compression approaches can enable the use of VSIE matrices of prohibitive memory requirements, by allowing the effective use of modern graphical processing units (GPUs) to accelerate the arising matrix\hyp vector products. This is critical to enable numerical MRI simulations at clinical voxel resolutions in a feasible computation time. In this paper, we demonstrate that the VSIE matrix\hyp vector products needed to calculate the electromagnetic field produced by an MRI coil inside a numerical body model with $1$ mm$^3$ voxel resolution, could be performed in $\sim 33$ seconds in a GPU, after compressing the associated coupling matrix from $\sim 80$ TB to $\sim 43$ MB.
△ Less
Submitted 2 June, 2021; v1 submitted 10 March, 2021;
originally announced March 2021.
-
Magnetic-resonance-based electrical property map** using Global Maxwell Tomography with an 8-channel head coil at 7 Tesla: a simulation study
Authors:
Ilias I. Giannakopoulos,
José E. C. Serrallés,
Luca Daniel,
Daniel K. Sodickson,
Athanasios G. Polimeridis,
Jacob K. White,
Riccardo Lattanzi
Abstract:
Objective: Global Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil. Methods: We designed a transmit-receive RF coil with…
▽ More
Objective: Global Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil. Methods: We designed a transmit-receive RF coil with $8$ decoupled channels for $7$T head imaging. We calculated the RF transmit field ($B_1^+$) inside heterogeneous head models for different RF shimming approaches, and used them as input for GMT to reconstruct EP for all voxels. Results: Coil tuning/decoupling remained relatively stable when the coil was loaded with different head models. Mean error in EP estimation changed from $7.5\%$ to $9.5\%$ and from $4.8\%$ to $7.2\%$ for relative permittivity and conductivity, respectively, when changing head model without re-tuning the coil. Results slightly improved when an SVD-based RF shimming algorithm was applied, in place of excitation with one coil at a time. Despite errors in EP, RF transmit field ($B_1^+$) and absorbed power could be predicted with less than $0.5\%$ error over the entire head. GMT could accurately detect a numerically inserted tumor. Conclusion: This work demonstrates that GMT can reliably reconstruct EP in realistic simulated scenarios using a tailored 8-channel RF coil design at $7$T. Future work will focus on construction of the coil and optimization of GMT's robustness to noise, to enable in-vivo GMT experiments. Significance: GMT could provide accurate estimations of tissue EP, which could be used as biomarkers and could enable patient-specific estimation of RF power deposition, which is an unsolved problem for ultra-high-field magnetic resonance imaging.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.