-
Skipper-in-CMOS: Non-Destructive Readout with Sub-Electron Noise Performance for Pixel Detectors
Authors:
Agustin J. Lapi,
Miguel Sofo-Haro,
Benjamin C. Parpillon,
Adi Birman,
Guillermo Fernandez-Moroni,
Lorenzo Rota,
Fabricio Alcalde Bessia,
Aseem Gupta,
Claudio Chavez Blanco,
Fernando Chierchie,
Julie Segal,
Christopher J. Kenney,
Angelo Dragone,
Shaorui Li,
Davide Braga,
Amos Fenigstein,
Juan Estrada,
Farah Fahim
Abstract:
The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtai…
▽ More
The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a 15 x 15 um^2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor's commercial 180 nm CMOS Image Sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep sub-electron noise of 0.15rms e-, demonstrating the charge transfer operation from the pinned photodiode and the single photon counting operation when the sensor is exposed to light. The article also discusses new testing strategies employed for its operation and characterization.
△ Less
Submitted 19 February, 2024;
originally announced February 2024.
-
Solid State Detectors and Tracking for Snowmass
Authors:
A. Affolder,
A. Apresyan,
S. Worm,
M. Albrow,
D. Ally,
D. Ambrose,
E. Anderssen,
N. Apadula,
P. Asenov,
W. Armstrong,
M. Artuso,
A. Barbier,
P. Barletta,
L. Bauerdick,
D. Berry,
M. Bomben,
M. Boscardin,
J. Brau,
W. Brooks,
M. Breidenbach,
J. Buckley,
V. Cairo,
R. Caputo,
L. Carpenter,
M. Centis-Vignali
, et al. (110 additional authors not shown)
Abstract:
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the…
▽ More
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).
△ Less
Submitted 19 October, 2022; v1 submitted 8 September, 2022;
originally announced September 2022.
-
Observation of magnetic Feshbach resonances between Cs and ${}^{173}$Yb
Authors:
Tobias Franzen,
Alexander Guttridge,
Kali E. Wilson,
Jack Segal,
Matthew D. Frye,
Jeremy M. Hutson,
Simon L. Cornish
Abstract:
We report the first observation of magnetic Feshbach resonances between ${}^{173}$Yb and $^{133}$Cs. In a mixture of Cs atoms prepared in the $(f=3, m_f=3)$ state and unpolarized fermionic ${}^{173}$Yb we observe resonant atom loss due to two sets of magnetic Feshbach resonances around 622~G and 702~G. Resonances for individual Yb nuclear spin components $m_{i,\mathrm{Yb}}$ are split by its intera…
▽ More
We report the first observation of magnetic Feshbach resonances between ${}^{173}$Yb and $^{133}$Cs. In a mixture of Cs atoms prepared in the $(f=3, m_f=3)$ state and unpolarized fermionic ${}^{173}$Yb we observe resonant atom loss due to two sets of magnetic Feshbach resonances around 622~G and 702~G. Resonances for individual Yb nuclear spin components $m_{i,\mathrm{Yb}}$ are split by its interaction with the Cs electronic spin, which also provides the main coupling mechanism for the observed resonances. The observed splittings and relative resonance strengths are in good agreement with theoretical predictions from coupled-channel calculations.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
Monolithic Active Pixel Sensors on CMOS technologies
Authors:
Nicole Apadula,
Whitney Armstrong,
James Brau,
Martin Breidenbach,
R. Caputo,
Gabriella Carinii,
Alberto Collu,
Marcel Demarteau,
Grzegorz Deptuch,
Angelo Dragone,
Gabriele Giacomini,
Carl Grace,
Norman Graf,
Leo Greiner,
Ryan Herbst,
Gunther Haller,
Manoj Jadhav,
Sylvester Joosten,
Christopher J. Kenney,
C. Kierans,
Jihee Kim,
Thomas Markiewicz,
Yuan Mei,
Jessica Metcalfe,
Zein-Eddine Meziani
, et al. (15 additional authors not shown)
Abstract:
Collider detectors have taken advantage of the resolution and accuracy of silicon detectors for at least four decades. Future colliders will need large areas of silicon sensors for low mass trackers and sampling calorimetry. Monolithic Active Pixel Sensors (MAPS), in which Si diodes and readout circuitry are combined in the same pixels, and can be fabricated in some of standard CMOS processes, are…
▽ More
Collider detectors have taken advantage of the resolution and accuracy of silicon detectors for at least four decades. Future colliders will need large areas of silicon sensors for low mass trackers and sampling calorimetry. Monolithic Active Pixel Sensors (MAPS), in which Si diodes and readout circuitry are combined in the same pixels, and can be fabricated in some of standard CMOS processes, are a promising technology for high-granularity and light detectors. In this paper we review 1) the requirements on MAPS for trackers and electromagnetic calorimeters (ECal) at future colliders experiments, 2) the ongoing efforts towards dedicated MAPS for the Electron-Ion Collider (EIC) at BNL, for which the EIC Silicon Consortium was already instantiated, and 3) space-born applications for MeV $γ$-ray experiments with MAPS based trackers (AstroPix).
△ Less
Submitted 28 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Radiation Hardness Study of the ePix100 Sensor and ASIC under Direct Illumination at the European XFEL
Authors:
I. Klačková,
K. Ahmed,
G. Blaj,
M. Cascella,
V. Cerantola,
C. Chang,
A. Dragone,
S. Göde,
S. Hauf,
C. Kenney,
J. Segal,
M. Kuster,
A. Šagátová
Abstract:
The ePix detector family provides multiple variants of hybrid pixel detectors to support a wide range of applications at free electron laser facilities. We present the results of a systematic study of the influence of radiation induced damage on the performance and lifetime of an ePix100a detector module using a direct attenuated beam of the EuXFEL at 9 keV photon energy and an average power of 10…
▽ More
The ePix detector family provides multiple variants of hybrid pixel detectors to support a wide range of applications at free electron laser facilities. We present the results of a systematic study of the influence of radiation induced damage on the performance and lifetime of an ePix100a detector module using a direct attenuated beam of the EuXFEL at 9 keV photon energy and an average power of 10 $μ$W. An area of 20 x 20 pixels was irradiated with an average photon flux of approx. 7 x $10^{9}$ photons/s to a dose of approximately 760$\pm$65 kGy at the location of the Si/SiO$_2$ interfaces in the sensor. A dose dependent increase in both offset and noise of the ePix100a detector have been observed originating from an increase of the sensor leakage current. Moreover, we observed an effect directly after irradiation resulting in the saturation of individual pixels by their dark current. Changes in gain are evaluated one and half hours post irradiation and suggest damage to occur also on the ASIC level. Based on the obtained results, thresholds for beam parameters are deduced and the detector lifetime is estimated with respect to the requirements to the data quality in order to satisfy the scientific standards defined by the experiments. We conclude the detector can withstand a beam with an energy up to 1 $μ$J at a photon energy of 9 keV impacting on an area of 1 mm$^2$. The detector can be used without significant degradation of its performance for several years if the incident photon beam intensities do not exceed the detector's dynamic range by at least three orders of magnitude. Our results provide valuable input for the operation of the ePix100a detector at FEL facilities and for the design of future detector technology.
△ Less
Submitted 17 August, 2021;
originally announced August 2021.
-
Measurement of the Nucleon $F^n_2/F^p_2$ Structure Function Ratio by the Jefferson Lab MARATHON Tritium/Helium-3 Deep Inelastic Scattering Experiment
Authors:
MARATHON Collaboration,
D. Abrams,
H. Albataineh,
B. S. Aljawrneh,
S. Alsalmi,
K. Aniol,
W. Armstrong,
J. Arrington,
H. Atac,
T. Averett,
C. Ayerbe Gayoso,
X. Bai,
J. Bane,
S. Barcus,
A. Beck,
V. Bellini,
H. Bhatt,
D. Bhetuwal,
D. Biswas,
D. Blyth,
W. Boeglin,
D. Bulumulla,
J. Butler,
A. Camsonne,
M. Carmignotto
, et al. (107 additional authors not shown)
Abstract:
The ratio of the nucleon $F_2$ structure functions, $F_2^n/F_2^p$, is determined by the MARATHON experiment from measurements of deep inelastic scattering of electrons from $^3$H and $^3$He nuclei. The experiment was performed in the Hall A Facility of Jefferson Lab and used two high resolution spectrometers for electron detection, and a cryogenic target system which included a low-activity tritiu…
▽ More
The ratio of the nucleon $F_2$ structure functions, $F_2^n/F_2^p$, is determined by the MARATHON experiment from measurements of deep inelastic scattering of electrons from $^3$H and $^3$He nuclei. The experiment was performed in the Hall A Facility of Jefferson Lab and used two high resolution spectrometers for electron detection, and a cryogenic target system which included a low-activity tritium cell. The data analysis used a novel technique exploiting the mirror symmetry of the two nuclei, which essentially eliminates many theoretical uncertainties in the extraction of the ratio. The results, which cover the Bjorken scaling variable range $0.19 < x < 0.83$, represent a significant improvement compared to previous SLAC and Jefferson Lab measurements for the ratio. They are compared to recent theoretical calculations and empirical determinations of the $F_2^n/F_2^p$ ratio.
△ Less
Submitted 9 June, 2021; v1 submitted 12 April, 2021;
originally announced April 2021.
-
Dynamics of a degenerate Cs-Yb mixture with attractive interspecies interactions
Authors:
Kali E. Wilson,
Alexander Guttridge,
I-Kang Liu,
Jack Segal,
Thomas P. Billam,
Nick G. Parker,
N. P. Proukakis,
Simon L. Cornish
Abstract:
We probe the collective dynamics of a quantum degenerate Bose-Bose mixture of Cs and $^{174}$Yb with attractive interspecies interactions. Specifically, we excite vertical center of mass oscillations of the Cs condensate, and observe significant dam** for the Cs dipole mode, due to the rapid transfer of energy to the larger Yb component, and the ensuing acoustic dissipation. Numerical simulation…
▽ More
We probe the collective dynamics of a quantum degenerate Bose-Bose mixture of Cs and $^{174}$Yb with attractive interspecies interactions. Specifically, we excite vertical center of mass oscillations of the Cs condensate, and observe significant dam** for the Cs dipole mode, due to the rapid transfer of energy to the larger Yb component, and the ensuing acoustic dissipation. Numerical simulations based on coupled Gross-Pitaevskii equations provide excellent agreement, and additionally reveal the possibility of late-time revivals (beating) which are found to be highly sensitive to the Cs and Yb atom number combinations. By further tuning the interaction strength of Cs using a broad Feshbach resonance, we explore the stability of the degenerate mixture, and observe collapse of the Cs condensate mediated by the attractive Cs-Yb interaction when $a_{\mathrm{Cs}}<50 \, a_0$, well above the single-species collapse threshold, in good agreement with simulations.
△ Less
Submitted 20 December, 2020;
originally announced December 2020.
-
Quantum Degenerate Mixtures of Cs and Yb
Authors:
Kali E. Wilson,
Alexander Guttridge,
Jack Segal,
Simon L. Cornish
Abstract:
We report the production of quantum degenerate Bose-Bose mixtures of Cs and Yb with both attractive (Cs + $^{174}$Yb) and repulsive (Cs + $^{170}$Yb) interspecies interactions. Dual-species evaporation is performed in a bichromatic optical dipole trap that combines light at 1070 nm and 532 nm to enable control of the relative trap depths for Cs and Yb. Maintaining a trap which is shallower for Yb…
▽ More
We report the production of quantum degenerate Bose-Bose mixtures of Cs and Yb with both attractive (Cs + $^{174}$Yb) and repulsive (Cs + $^{170}$Yb) interspecies interactions. Dual-species evaporation is performed in a bichromatic optical dipole trap that combines light at 1070 nm and 532 nm to enable control of the relative trap depths for Cs and Yb. Maintaining a trap which is shallower for Yb throughout the evaporation leads to highly efficient sympathetic cooling of Cs for both isotopic combinations at magnetic fields close to the Efimov minimum in the Cs three-body recombination rate at around 22 G. For Cs + $^{174}$Yb, we produce quantum mixtures with typical atom numbers of $N_\mathrm{Yb} \sim 5 \times 10^4$ and $N_\mathrm{Cs} \sim 5 \times 10^3$. We find that the attractive interspecies interaction (characterised by the scattering length $a_\mathrm{CsYb} = -75\,a_0$) is stabilised by the repulsive intraspecies interactions. For Cs + $^{170}$Yb, we produce quantum mixtures with typical atom numbers of $N_\mathrm{Yb} \sim 4 \times 10^4$, and $N_\mathrm{Cs} \sim 1 \times 10^4$. Here, the repulsive interspecies interaction ($a_\mathrm{CsYb} = 96\,a_0$) can overwhelm the intraspecies interactions, such that the mixture sits in a region of partial miscibility.
△ Less
Submitted 18 March, 2021; v1 submitted 10 November, 2020;
originally announced November 2020.
-
Steady State versus Pulsed Tokamak Reactors
Authors:
Daniel J. Segal,
Antoine J. Cerfon,
Jeffrey P. Freidberg
Abstract:
We have carried out a detailed analysis that compares steady state versus pulsed tokamak reactors. The motivations are as follows. Steady state current drive has turned out to be more difficult than expected - it takes too many watts to drive an Ampere, which has a negative effect on power balance and economics. This is partially compensated by the recent development of high temperature REBCO supe…
▽ More
We have carried out a detailed analysis that compares steady state versus pulsed tokamak reactors. The motivations are as follows. Steady state current drive has turned out to be more difficult than expected - it takes too many watts to drive an Ampere, which has a negative effect on power balance and economics. This is partially compensated by the recent development of high temperature REBCO superconductors, which offers the promise of more compact, lower cost tokamak reactors, both steady state and pulsed. Of renewed interest is the reduction in size of pulsed reactors because of the possibility of higher field OH transformers for a given required pulse size. Our main conclusion is that pulsed reactors may indeed be competitive with steady state reactors and this issue should be re-examined with more detailed engineering level studies.
△ Less
Submitted 24 August, 2020;
originally announced August 2020.
-
200 mm Sensor Development Using Bonded Wafers
Authors:
M. Alyari,
R. Bradford,
M. Campanella,
P. Camporeale,
R. Demina,
J. Everts,
Z. Gecse,
R. Halenza,
U. Heintz,
S. Holland,
S. Hong,
S. Korjenevski,
A. Lampis,
R. Lipton,
R. Patti,
J. Segal,
K. W. Shin
Abstract:
Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to $\> 200\ m^2$ for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than $200\ m^2$ of silicon and the CMS Hi…
▽ More
Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to $\> 200\ m^2$ for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than $200\ m^2$ of silicon and the CMS High Granularity Calorimeter (HGCAL) will require more than $600\ m^2$. The cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the size of the silicon sensors. In addition to large area, the devices must be radiation hard, which requires the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work. We describe work on development of thin sensors on $200 mm$ wafers using wafer bonding technology. Results of development runs with float zone, Silicon-on-Insulator and Silicon-Silicon bonded wafer technologies are reported.
△ Less
Submitted 2 September, 2020; v1 submitted 8 June, 2020;
originally announced June 2020.
-
Brand vs. Generic: Addressing Non-Adherence, Secular Trends, and Non-Overlap
Authors:
Lamar Hunt III,
Irene B. Murimi,
Jodi B. Segal,
Marissa J. Seamans,
Daniel O. Scharfstein,
Ravi Varadhan
Abstract:
While generic drugs offer a cost-effective alternative to brand name drugs, regulators need a method to assess therapeutic equivalence in a post market setting. We develop such a method in the context of assessing the therapeutic equivalence of immediate release (IM) venlafaxine, based on a large insurance claims dataset provided by OptumLabs\textsuperscript{\textregistered}. To properly address t…
▽ More
While generic drugs offer a cost-effective alternative to brand name drugs, regulators need a method to assess therapeutic equivalence in a post market setting. We develop such a method in the context of assessing the therapeutic equivalence of immediate release (IM) venlafaxine, based on a large insurance claims dataset provided by OptumLabs\textsuperscript{\textregistered}. To properly address this question, our methodology must deal with issues of non-adherence, secular trends in health outcomes, and lack of treatment overlap due to sharp uptake of the generic once it becomes available. We define, identify (under assumptions) and estimate (using G-computation) a causal effect for a time-to-event outcome by extending regression discontinuity to survival curves. We do not find evidence for a lack of therapeutic equivalence of brand and generic IM venlafaxine.
△ Less
Submitted 7 July, 2019;
originally announced July 2019.
-
Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers
Authors:
G. Blaj,
D. Bhogadi,
C. -E. Chang,
D. Doering,
C. J. Kenney,
T. Kroll,
M. Kwiatkowski,
J. Segal,
D. Sokaras,
G. Haller
Abstract:
Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches with strip detectors or small pixel detectors are not ideal. We present a novel approach, with a sensor…
▽ More
Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches with strip detectors or small pixel detectors are not ideal. We present a novel approach, with a sensor using rectangular pixels with a high aspect ratio (between strips and pixels, further called "strixels"), and strixel redistribution to match the square pixel arrays of typical ASICs while avoiding the considerable effort of redesigning ASICs. This results in a sensor area of 17.4 mm x 77 mm, with a fine pitch of 25 $μ$m in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e$^-$, or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 $μ$m) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 $μ$m) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution ($\sim$1 $μ$m) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with existing versions of ePix cameras.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs
Authors:
G. Blaj,
A. Dragone,
C. J. Kenney,
F. Abu-Nimeh,
P. Caragiulo,
D. Doering,
M. Kwiatkowski,
J. Pines,
M. Weaver,
S. Boutet,
G. Carini,
C. -E. Chang,
P. Hart,
J. Hasi,
M. Hayes,
R. Herbst,
J. Koglin,
K. Nakahara,
J. Segal,
G. Haller
Abstract:
ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs,…
▽ More
ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352x384 pixels of 100 $μ$m x 100 $μ$m each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e$^-$ equivalent noise charge (ENC), and a range of 11000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A
Authors:
Jefferson Lab Hall A Collaboration,
F. Garibaldi,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Beturin,
H. Benaoum,
J. Benesch,
P. Y. Bertin,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
F. Cusanno,
B. J. Craver,
G. De Cataldo
, et al. (75 additional authors not shown)
Abstract:
The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0p-shell region of nuclei such as the hypernuclei produced in electroproduction on 9Be, 12C and 16O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were adde…
▽ More
The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0p-shell region of nuclei such as the hypernuclei produced in electroproduction on 9Be, 12C and 16O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. For the first time, measurable strength with sub-MeV energy resolution was observed for the core-excited states of Lambda 12B. A high-quality Lambda 16N hypernuclear spectrum was likewise obtained. A first measurement of the Lambda binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 +/- 0.16 MeV. Similarly, the first Lambda 9Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Lambda separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been shown that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the gamma-ray spectroscopy technique.
△ Less
Submitted 26 July, 2018; v1 submitted 25 July, 2018;
originally announced July 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Quantum Sensing for High Energy Physics
Authors:
Zeeshan Ahmed,
Yuri Alexeev,
Giorgio Apollinari,
Asimina Arvanitaki,
David Awschalom,
Karl K. Berggren,
Karl Van Bibber,
Przemyslaw Bienias,
Geoffrey Bodwin,
Malcolm Boshier,
Daniel Bowring,
Davide Braga,
Karen Byrum,
Gustavo Cancelo,
Gianpaolo Carosi,
Tom Cecil,
Clarence Chang,
Mattia Checchin,
Sergei Chekanov,
Aaron Chou,
Aashish Clerk,
Ian Cloet,
Michael Crisler,
Marcel Demarteau,
Ranjan Dharmapalan
, et al. (91 additional authors not shown)
Abstract:
Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.
Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.
-
Detector Damage at X-Ray Free-Electron Laser Sources
Authors:
G. Blaj,
G. Carini,
S. Carron,
G. Haller,
P. Hart,
J. Hasi,
S. Herrmann,
C. Kenney,
J. Segal,
C. A. Stan,
A. Tomada
Abstract:
Free-electron lasers (FELs) opened a new window on imaging the motion of atoms and molecules. At SLAC, FEL experiments are performed at LCLS using 120 Hz pulses with 10^12 to 10^13 photons in 10 fs (billions of times brighter than at the most powerful synchrotrons). Concurrently, users and staff operate under high pressure due to flexible and often rapidly changing setups and low tolerance for sys…
▽ More
Free-electron lasers (FELs) opened a new window on imaging the motion of atoms and molecules. At SLAC, FEL experiments are performed at LCLS using 120 Hz pulses with 10^12 to 10^13 photons in 10 fs (billions of times brighter than at the most powerful synchrotrons). Concurrently, users and staff operate under high pressure due to flexible and often rapidly changing setups and low tolerance for system malfunction. This extreme detection environment raises unique challenges, from obvious to surprising, and leads to treating detectors as consumables. We discuss in detail the detector damage mechanisms observed in 7 years of operation at LCLS, together with the corresponding damage mitigation strategies and their effectiveness. Main types of damage mechanisms already identified include: (1) x-ray radiation damage (from "catastrophic" to "classical"), (2) direct and indirect damage caused by optical lasers, (3) sample induced damage, (4) vacuum related damage, (5) high-pressure environment. In total, 19 damage mechanisms have been identified. We also present general strategies for reducing damage risk or minimizing the impact of detector damage on the science program. These include availability of replacement parts and skilled operators and also careful planning, incident investigation resulting in updated designs, procedures and operator training.
△ Less
Submitted 5 June, 2017;
originally announced June 2017.
-
Analytical Solutions of Transient Drift-Diffusion in P-N Junction Pixel Sensors
Authors:
G. Blaj,
C. J. Kenney,
J. Segal,
G. Haller
Abstract:
Radiation detection in applications ranging from high energy physics to medical imaging rely on solid state detectors, often hybrid pixel detectors with (1) reverse biased p-n junction pixel sensors and (2) readout ASICs, attached by flip-chip-bonding. Transient signals characteristics are important in, e.g., matching ASIC and sensor design, modeling and optimizing detector parameters and describi…
▽ More
Radiation detection in applications ranging from high energy physics to medical imaging rely on solid state detectors, often hybrid pixel detectors with (1) reverse biased p-n junction pixel sensors and (2) readout ASICs, attached by flip-chip-bonding. Transient signals characteristics are important in, e.g., matching ASIC and sensor design, modeling and optimizing detector parameters and describing timing and charge sharing properties. Currently analytical forms of transient signals are available for only a few limited cases (e.g., drift or diffusion) or for the steady state (which is not relevant for high energy radiation detection). Tools are available for (relatively slow) numerical evaluation of the transient charge transport. We present here the first analytical solutions of partial differential equations describing drift-diffusion-recombination charge transport in planar p-n junction sensors in a variety of conditions: (1) undepleted, (2) fully depleted, (3) taking into account the gradual velocity saturation, and (4) overdepleted. We deduce the Green's functions which can be applied to any detection problem through simple convolution with the initial conditions. We compare the analytical solutions with Monte Carlo simulations and industry standard simulations (Synopsys Sentaurus), demonstrating good agreement. Using the analytical equations enables fast modeling of the influence of various detector parameters on tracking, imaging and timing performance, describing performance and enabling optimizations for different applications. Finally, we illustrate this model with applications in 3D+T (x,y,z,time) photon tracking and 4D+T (x,y,theta,phi,time) relativistic charged particle tracking.
△ Less
Submitted 5 June, 2017;
originally announced June 2017.
-
JLab Measurements of the 3He Form Factors at Large Momentum Transfers
Authors:
A. Camsonne,
A. T. Katramatou,
M. Olson,
A. Acha,
K. Allada,
B. D. Anderson,
J. Arrington,
A. Baldwin,
J. -P. Chen,
S. Choi,
E. Chudakov,
E. Cisbani,
B. Craver,
P. Decowski,
C. Dutta,
E. Folts,
S. Frullani,
F. Garibaldi,
R. Gilman,
J. Gomez,
B. Hahn,
J. -O. Hansen,
D. W. Higinbotham,
T. Holmstrom,
J. Huang
, et al. (44 additional authors not shown)
Abstract:
The charge and magnetic form factors, FC and FM, of 3He have been extracted in the kinematic range 25 fm-2 < Q2 < 61 fm-2 from elastic electron scattering by detecting 3He recoil nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements are indicative of a second diffraction minimum for the magnetic form factor, which was p…
▽ More
The charge and magnetic form factors, FC and FM, of 3He have been extracted in the kinematic range 25 fm-2 < Q2 < 61 fm-2 from elastic electron scattering by detecting 3He recoil nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements are indicative of a second diffraction minimum for the magnetic form factor, which was predicted in the Q2 range of this experiment, and of a continuing diffractive structure for the charge form factor. The data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.
△ Less
Submitted 24 October, 2016;
originally announced October 2016.
-
Spectroscopy of Lambda-9Li by electroproduction
Authors:
G. M. Urciuoli,
F. Cusanno,
S. Marrone,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Baturin,
P. Y. Bertin,
H. Benaoum,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
B. J. Craver,
G. De Cataldo,
C. W. de Jager
, et al. (73 additional authors not shown)
Abstract:
In the absence of accurate data on the free two-body hyperon-nucleon interaction, the spectra of hypernuclei can provide information on the details of the effective hyperon-nucleon interaction. Electroproduction of the hypernucleus Lambda-9Li has been studied for the first time with sub-MeV energy resolution in Hall A at Jefferson Lab on a 9Be target. In order to increase the counting rate and to…
▽ More
In the absence of accurate data on the free two-body hyperon-nucleon interaction, the spectra of hypernuclei can provide information on the details of the effective hyperon-nucleon interaction. Electroproduction of the hypernucleus Lambda-9Li has been studied for the first time with sub-MeV energy resolution in Hall A at Jefferson Lab on a 9Be target. In order to increase the counting rate and to provide unambiguous kaon identification, two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. The cross section to low-lying states of Lambda-9Li is concentrated within 3 MeV of the ground state and can be fitted with four peaks. The positions of the doublets agree with theory while a disagreement could exist with respect to the relative strengths of the peaks in the doublets. A Lambda separation energy of 8.36 +- 0.08 (stat.) +- 0.08 (syst.) MeV was measured, in agreement with an earlier experiment.
△ Less
Submitted 1 October, 2014; v1 submitted 22 May, 2014;
originally announced May 2014.
-
JLab Measurement of the $^4$He Charge Form Factor at Large Momentum Transfers
Authors:
A. Camsonne,
A. T. Katramatou,
M. Olson,
N. Sparveris,
A. Acha,
K. Allada,
B. D. Anderson,
J. Arrington,
A. Baldwin,
J. -P. Chen,
S. Choi,
E. Chudakov,
E. Cisbani,
B. Craver,
P. Decowski,
C. Dutta,
E. Folts,
S. Frullani,
F. Garibaldi,
R. Gilman,
J. Gomez,
B. Hahn,
J. -O. Hansen,
D. Higinbotham,
T. Holmstrom
, et al. (44 additional authors not shown)
Abstract:
The charge form factor of $^$4He has been extracted in the range 29 fm$^{-2}$ $\le Q^2 \le 77$ fm$^{-2}$ from elastic electron scattering, detecting $^4$He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second…
▽ More
The charge form factor of $^$4He has been extracted in the range 29 fm$^{-2}$ $\le Q^2 \le 77$ fm$^{-2}$ from elastic electron scattering, detecting $^4$He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second diffraction minimum, which was predicted in the $Q^2$ range of this experiment, and rule out conclusively long-standing predictions of dimensional scaling of high-energy amplitudes using quark counting.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
-
Measurement of the 12C(e,e'p)11B Two-Body Breakup Reaction at High Missing Momentum Values
Authors:
P. Monaghan,
R. Shneor,
R. Subedi,
B. D. Anderson,
K. Aniol,
J. Annand,
J. Arrington,
H. Benaoum,
F. Benmokhtar,
P. Bertin,
W. Bertozzi,
W. Boeglin,
J. P. Chen,
Seonho Choi,
E. Chudakov,
C. Ciofi degli Atti,
E. Cisbani,
W. Cosyn,
B. Craver,
C. W. de Jager,
R. J. Feuerbach,
E. Folts,
S. Frullani,
F. Garibaldi,
O. Gayou
, et al. (59 additional authors not shown)
Abstract:
The five-fold differential cross section for the 12C(e,e'p)11B reaction was determined over a missing momentum range of 200-400 MeV/c, in a kinematics regime with Bjorken x > 1 and Q2 = 2.0 (GeV/c)2. A comparison of the results and theoretical models and previous lower missing momentum data is shown. The theoretical calculations agree well with the data up to a missing momentum value of 325 MeV/c…
▽ More
The five-fold differential cross section for the 12C(e,e'p)11B reaction was determined over a missing momentum range of 200-400 MeV/c, in a kinematics regime with Bjorken x > 1 and Q2 = 2.0 (GeV/c)2. A comparison of the results and theoretical models and previous lower missing momentum data is shown. The theoretical calculations agree well with the data up to a missing momentum value of 325 MeV/c and then diverge for larger missing momenta. The extracted distorted momentum distribution is shown to be consistent with previous data and extends the range of available data up to 400 MeV/c.
△ Less
Submitted 16 June, 2014; v1 submitted 29 January, 2013;
originally announced January 2013.
-
Search for a new gauge boson in the $A'$ Experiment (APEX)
Authors:
S. Abrahamyan,
Z. Ahmed,
K. Allada,
D. Anez,
T. Averett,
A. Barbieri,
K. Bartlett,
J. Beacham,
J. Bono,
J. R. Boyce,
P. Brindza,
A. Camsonne,
K. Cranmer,
M. M. Dalton,
C. W. deJager,
J. Donaghy,
R. Essig,
C. Field,
E. Folts,
A. Gasparian,
N. Goeckner-Wald,
J. Gomez,
M. Graham,
J. -O. Hansen,
D. W. Higinbotham
, et al. (41 additional authors not shown)
Abstract:
We present a search at Jefferson Laboratory for new forces mediated by sub-GeV vector bosons with weak coupling $α'$ to electrons. Such a particle $A'$ can be produced in electron-nucleus fixed-target scattering and then decay to an $e^+e^-$ pair, producing a narrow resonance in the QED trident spectrum. Using APEX test run data, we searched in the mass range 175--250 MeV, found no evidence for an…
▽ More
We present a search at Jefferson Laboratory for new forces mediated by sub-GeV vector bosons with weak coupling $α'$ to electrons. Such a particle $A'$ can be produced in electron-nucleus fixed-target scattering and then decay to an $e^+e^-$ pair, producing a narrow resonance in the QED trident spectrum. Using APEX test run data, we searched in the mass range 175--250 MeV, found no evidence for an $A'\to e^+e^-$ reaction, and set an upper limit of $α'/α\simeq 10^{-6}$. Our findings demonstrate that fixed-target searches can explore a new, wide, and important range of masses and couplings for sub-GeV forces.
△ Less
Submitted 21 August, 2011; v1 submitted 12 August, 2011;
originally announced August 2011.
-
Measurements of the Electric Form Factor of the Neutron up to Q2=3.4 GeV2 using the Reaction He3(e,e'n)pp
Authors:
S. Riordan,
S. Abrahamyan,
B. Craver,
A. Kelleher,
A. Kolarkar,
J. Miller,
G. D. Cates,
N. Liyanage,
B. Wojtsekhowski,
A. Acha,
K. Allada,
B. Anderson,
K. A. Aniol,
J. R. M. Annand,
J. Arrington,
T. Averett,
A. Beck,
M. Bellis,
W. Boeglin,
H. Breuer,
J. R. Calarco,
A. Camsonne,
J. P. Chen,
E. Chudakov,
L. Coman
, et al. (93 additional authors not shown)
Abstract:
The electric form factor of the neutron was determined from studies of the reaction He3(e,e'n)pp in quasi-elastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with ne…
▽ More
The electric form factor of the neutron was determined from studies of the reaction He3(e,e'n)pp in quasi-elastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons that were registered in a large-solid-angle detector. More than doubling the Q2-range over which it is known, we find GEn = 0.0225 +/- 0.0017 (stat) +/- 0.0024 (syst), 0.0200 +/- 0.0023 +/- 0.0018, and 0.0142 +/- 0.0019 +/- 0.0013 for Q2 = 1.72, 2.48, and 3.41 GeV2, respectively.
△ Less
Submitted 2 November, 2010; v1 submitted 10 August, 2010;
originally announced August 2010.
-
High Resolution Spectroscopy of 16N_Lambda by Electroproduction
Authors:
F. Cusanno,
G. M. Urciuoli,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Baturin,
P. Y. Bertin,
H. Benaoum,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
B. J. Craver,
G. De Cataldo,
C. W. de Jager,
R. De Leo
, et al. (74 additional authors not shown)
Abstract:
An experimental study of the 16O(e,e'K^+)16N_Lambda reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e,e'K^+)Lambda,Sigma_0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 +/- 0.16 MeV was obtained for 16N_Lambda with better precision than p…
▽ More
An experimental study of the 16O(e,e'K^+)16N_Lambda reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e,e'K^+)Lambda,Sigma_0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 +/- 0.16 MeV was obtained for 16N_Lambda with better precision than previous measurements on the mirror hypernucleus 16O_Lambda. Precise energies have been determined for peaks arising from a Lambda in s and p orbits coupled to the p_{1/2} and p_{3/2} hole states of the 15N core nucleus.
△ Less
Submitted 12 November, 2009; v1 submitted 21 October, 2008;
originally announced October 2008.
-
High Resolution Spectroscopy of 12B_Lambda by Electroproduction
Authors:
M. Iodice,
F. Cusanno,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Baturin,
P. Y. Bertin,
H. Benaoum,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
B. J. Craver,
G. DeCataldo,
C. W. deJager,
R. DeLeo
, et al. (74 additional authors not shown)
Abstract:
An experiment measuring electroproduction of hypernuclei has been performed in Hall A at Jefferson Lab on a $^{12}$C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has bee…
▽ More
An experiment measuring electroproduction of hypernuclei has been performed in Hall A at Jefferson Lab on a $^{12}$C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has been achieved. Thus, the observed \lam{12}{B} spectrum shows for the first time identifiable strength in the core-excited region between the ground-state {\it s}-wave $Λ$ peak and the 11 MeV {\it p}-wave $Λ$ peak.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.
-
An Electromagnetic Calorimeter for the JLab Real Compton Scattering Experiment
Authors:
D. J. Hamilton,
A. Shahinyan,
B. Wojtsekhowski,
J. R. M. Annand,
T. -H. Chang,
E. Chudakov,
A. Danagoulian,
P. Degtyarenko,
K. Egiyan,
R. Gilman,
V. Gorbenko,
J. Hines,
E. Hovhannisyan,
C. E. Hyde-Wright,
C. W. de Jager,
A. Ketikyan,
V. H. Mamyan,
R. Michaels,
A. M. Nathan,
V. Nelyubin,
I. Rachek,
M. Roedelbrom,
A. Petrosyan,
R. Pomatsalyuk,
V. Popov
, et al. (4 additional authors not shown)
Abstract:
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the…
▽ More
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/\sqrt(Eγ [GeV]). Features of both the detector design and its performance in the high luminosity environment during the experiment are presented.
△ Less
Submitted 25 September, 2015; v1 submitted 14 April, 2007;
originally announced April 2007.
-
Invariant rings of orthogonal groups over the field of two elements
Authors:
P. H. Kropholler,
S. Mosheni Rajaei,
J. Segal
Abstract:
We determine the rings of invariants in the symmetric algebra on the dual of a vector space V over the field of two elements, for the group G of orthogonal transformations preserving a non-singular quadratic form on V. The invariant ring is shown to have a presentation in which the difference between the number of generators and the number of relations is equal to the minimum possibility, namely…
▽ More
We determine the rings of invariants in the symmetric algebra on the dual of a vector space V over the field of two elements, for the group G of orthogonal transformations preserving a non-singular quadratic form on V. The invariant ring is shown to have a presentation in which the difference between the number of generators and the number of relations is equal to the minimum possibility, namely the dimension of V, and it is shown to be a complete intersection. In particular, the rings of invariants computed here are all Gorenstein and hence Cohen-Macaulay.
△ Less
Submitted 22 December, 2003;
originally announced December 2003.
-
Precise n-gram Probabilities from Stochastic Context-free Grammars
Authors:
Andreas Stolcke,
Jonathan Segal
Abstract:
We present an algorithm for computing n-gram probabilities from stochastic context-free grammars, a procedure that can alleviate some of the standard problems associated with n-grams (estimation from sparse data, lack of linguistic structure, among others). The method operates via the computation of substring expectations, which in turn is accomplished by solving systems of linear equations deri…
▽ More
We present an algorithm for computing n-gram probabilities from stochastic context-free grammars, a procedure that can alleviate some of the standard problems associated with n-grams (estimation from sparse data, lack of linguistic structure, among others). The method operates via the computation of substring expectations, which in turn is accomplished by solving systems of linear equations derived from the grammar. We discuss efficient implementation of the algorithm and report our practical experience with it.
△ Less
Submitted 10 May, 1994;
originally announced May 1994.