Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (115 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
Authors:
SENSEI Collaboration,
Prakruth Adari,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Michael Crisler,
Miguel Daal,
Ansh Desai,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Yonatan Kehat,
Yaron Korn,
Ian Lawson,
Steffon Luoma,
Aviv Orly,
Santiago E. Perez,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza
, et al. (12 additional authors not shown)
Abstract:
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 elect…
▽ More
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
CUTE: A Cryogenic Underground TEst Facility at SNOLAB
Authors:
Philippe Camus,
Jonathan Corbett,
Sean Crawford,
Koby Dering,
Eleanor Fascione,
Gilles Gerbier,
Richard Germond,
Muad Ghaith,
Jeter Hall,
Ziqing Hong,
Andrew Kubik,
Adam Mayer,
Serge Nagorny,
Payam Pakarha,
Wolfgang Rau,
Silvia Scorza,
Ryan Underwood
Abstract:
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range. Devices based on these technologies are often sensitive to small energy depositions as can be caused by environmental radiation. The Cryogenic Underground TEst…
▽ More
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range. Devices based on these technologies are often sensitive to small energy depositions as can be caused by environmental radiation. The Cryogenic Underground TEst facility (CUTE) at SNOLAB is a platform for testing and operating cryogenic devices in an environment with low levels of background. The large experimental chamber ($\mathcal{O}$(10) L) reaches a base temperature of $\sim$12 mK; it can hold a payload of up to $\sim$20 kg and provides a radiogenic background event rate as low as a few events/kg/keV/day in the energy range below about 100 keV, as well as a negligible muon rate ($\mathcal{O}$(1)/month). CUTE was designed and built in the context of the Super Cryogenic Dark Matter Search experiment (SuperCDMS) which uses cryogenic detectors to search for interactions of dark matter particles with ordinary matter. The facility has been used to test SuperCDMS detectors since its commissioning in 2019. In 2021, it was handed over to SNOLAB to become a SNOLAB user facility after the completion of the testing of detectors for SuperCDMS. The facility will be available for projects that benefit from these special conditions, based on proposals assessed for their scientific and technological merits. This article describes the main design features and operating parameters of CUTE.
△ Less
Submitted 30 January, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Evaluation of SNOLAB background mitigation procedures through the use of an ICP-MS based dust monitoring methodology
Authors:
M. L. di Vacri,
S. Scorza,
A. French,
N. D. Rocco,
T. D. Schlieder,
I. J. Arnquist,
E. W. Hoppe,
J. Hall
Abstract:
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models…
▽ More
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. In this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB, and informs dust backgrounds during laboratory activities. Fallout rates of major constituent of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. A ca. two order of magnitude increase in stable Pb fallout rate was determined in an experimental area during activities involving handling of Pb bricks. Increased K-40, Th-232, and U-238 fallout rates were measured in clean experimental areas during activities generating particulate.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M
Authors:
I. Arnquist,
N. Avalos,
D. Baxter,
X. Bertou,
N. Castello-Mor,
A. E. Chavarria,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
J. Duarte-Campderros,
E. Estrada,
N. Gadola,
R. Gaior,
T. Hossbach,
L. Iddir,
B. J. Kavanagh,
B. Kilminster,
A. Lantero-Barreda,
I. Lawson,
S. Lee,
A. Letessier-Selvon,
P. Loaiza,
A. Lopez-Virto,
K. J. McGuire
, et al. (15 additional authors not shown)
Abstract:
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from D…
▽ More
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with periods in the range 1-48 h. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Paarl Africa Underground Laboratory (PAUL)
Authors:
Robert Adam,
Claire Antel,
Munirat Bashir,
Driss Benchekroun,
Xavier Bertou,
Markus Böttcher,
Andy Buffler,
Andrew Chen,
Rouven Essig,
Jules Gascon,
Mohamed Gouighri,
Trevor Hass,
Gregory Hillhouse,
Abdeslam Hoummada,
Anslyn John,
Pete Jones,
Youssef Khoulaki,
Luca Lavina,
Lerothodi Leeuw,
Mantile Lekala,
Robert Lindsay,
Roy Maartens,
Yin-Zhe Ma,
Fairouz Malek,
Peane Maleka
, et al. (21 additional authors not shown)
Abstract:
Establishing a deep underground physics laboratory to study, amongst others, double beta decay, geoneutrinos, reactor neutrinos and dark matter has been discussed for more than a decade within the austral African physicists' community. PAUL, the Paarl Africa Underground Laboratory, is an initiative foreseeing an open international laboratory devoted to the development of competitive science in the…
▽ More
Establishing a deep underground physics laboratory to study, amongst others, double beta decay, geoneutrinos, reactor neutrinos and dark matter has been discussed for more than a decade within the austral African physicists' community. PAUL, the Paarl Africa Underground Laboratory, is an initiative foreseeing an open international laboratory devoted to the development of competitive science in the austral region. It has the advantage that the location, the Huguenot tunnel, exists already and the geology and the environment of the site is appropriate for an experimental facility. The paper describes the PAUL initiative, presents the physics prospects and discusses the capacity for building the future experimental facility.
△ Less
Submitted 21 June, 2023;
originally announced June 2023.
-
Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs
Authors:
A. Aguilar-Arevalo,
I. Arnquist,
N. Avalos,
L. Barak,
D. Baxter,
X. Bertou,
I. M. Bloch,
A. M. Botti,
M. Cababie,
G. Cancelo,
N. Castelló-Mor,
B. A. Cervantes-Vergara,
A. E. Chavarria,
J. Cortabitarte-Gutiérrez,
M. Crisler,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
A. Drlica-Wagner,
J. Duarte-Campderros,
J. C. D'Olivo,
R. Essig,
E. Estrada,
J. Estrada
, et al. (47 additional authors not shown)
Abstract:
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. W…
▽ More
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
△ Less
Submitted 26 March, 2024; v1 submitted 2 June, 2023;
originally announced June 2023.
-
First demonstration of 30 eVee ionization energy resolution with Ricochet germanium cryogenic bolometers
Authors:
C. Augier,
G. Baulieu,
V. Belov,
L. Bergé,
J. Billard,
G. Bres,
J. -L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chala,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
E. Cudmore,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. -B. Filippini
, et al. (55 additional authors not shown)
Abstract:
The future Ricochet experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the Ricochet collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector…
▽ More
The future Ricochet experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the Ricochet collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30~eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar heat-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector. Additionally, we discuss the implications of these results in the context of the future Ricochet experiment and its expected background mitigation performance.
△ Less
Submitted 31 May, 2023;
originally announced June 2023.
-
SENSEI: Search for Millicharged Particles produced in the NuMI Beam
Authors:
Liron Barak,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Roni Harnik,
Stephen E. Holland,
Yaron Korn,
Zhen Liu,
Sravan Munagavalasa,
Aviv Orly,
Santiago E. Perez,
Ryan Plestid,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza,
Aman Singal,
Miguel Sofo Haro
, et al. (6 additional authors not shown)
Abstract:
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisi…
▽ More
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisions of protons in the NuMI beam with a fixed graphite target. The absence of any ionization events with 3 to 6 electrons in the SENSEI data allow us to place world-leading constraints on millicharged particles for masses between 30 MeV to 380 MeV. This work also demonstrates the potential of utilizing low-threshold detectors to investigate new particles in beam-dump experiments, and motivates a future experiment designed specifically for this purpose.
△ Less
Submitted 24 May, 2023; v1 submitted 8 May, 2023;
originally announced May 2023.
-
Results from a Prototype TES Detector for the Ricochet Experiment
Authors:
Ricochet Collaboration,
C. Augier,
G. Baulieu,
V. Belov,
L. Bergé,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chala,
C. L. Chang,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
E. Cudmore,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol
, et al. (66 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of $\sim$30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the "Q-Array") will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.
△ Less
Submitted 12 January, 2024; v1 submitted 28 April, 2023;
originally announced April 2023.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley,
H. Coombes
, et al. (108 additional authors not shown)
Abstract:
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nuc…
▽ More
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 17 February, 2023;
originally announced February 2023.
-
Effective Field Theory Analysis of CDMSlite Run 2 Data
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (105 additional authors not shown)
Abstract:
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected back…
▽ More
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Snowmass2021 Cosmic Frontier White Paper: Calibrations and backgrounds for dark matter direct detection
Authors:
Daniel Baxter,
Raymond Bunker,
Sally Shaw,
Shawn Westerdale,
Isaac Arnquist,
Daniel S. Akerib,
Rob Calkins,
Susana Cebrián,
James B. Dent,
Maria Laura di Vacri,
Jim Dobson,
Daniel Egana-Ugrinovic,
Andrew Erlandson,
Chamkaur Ghag,
Carter Hall,
Jeter Hall,
Scott Haselschwardt,
Eric Hoppe,
Chris M. Jackson,
Yonatan Kahn,
Alvine Kamaha,
Mike Kelsey,
Alexander Kish,
Noah Kurinsky,
Matthias Laubenstein
, et al. (26 additional authors not shown)
Abstract:
Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background rates in future detectors. Improving the precision of signal and background modeling goes hand-in-hand with novel calibration techniques that can probe rare processes and lower threshold detector response. The goal of t…
▽ More
Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background rates in future detectors. Improving the precision of signal and background modeling goes hand-in-hand with novel calibration techniques that can probe rare processes and lower threshold detector response. The goal of this white paper is to outline community needs to meet the background and calibration requirements of next-generation dark matter direct detection experiments.
△ Less
Submitted 1 May, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
SuperCDMS Collaboration,
Musaab Al-Bakry,
Imran Alkhatib,
Dorian Praia do Amaral,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Iman Ataee Langroudy,
Elham Azadbakht,
Samir Banik,
Corey Bathurst,
Dan Bauer,
Lucas Bezerra,
Rik Bhattacharyya,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Robert Cameron,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Mouli Chaudhuri,
Ran Chen,
Nicholas Chott
, et al. (106 additional authors not shown)
Abstract:
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucle…
▽ More
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 19 May, 2022; v1 submitted 4 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Direct method for the quantitative analysis of surface contamination on ultra-low background materials from exposure to dust
Authors:
M. L. di Vacri,
I. J. Arnquist,
S. Scorza,
E. W. Hoppe,
Jeter Hall
Abstract:
In this work we present a method for the direct determination of contaminant fallout rates on material surfaces from exposure to dust. Naturally occurring radionuclides K-40, Th-232, U-238 and stable Pb were investigated. Until now, background contributions from dust particulate have largely been estimated from fallout models and assumed dust composition. Our method utilizes a variety of low backg…
▽ More
In this work we present a method for the direct determination of contaminant fallout rates on material surfaces from exposure to dust. Naturally occurring radionuclides K-40, Th-232, U-238 and stable Pb were investigated. Until now, background contributions from dust particulate have largely been estimated from fallout models and assumed dust composition. Our method utilizes a variety of low background collection media for exposure in locations of interest, followed by surface leaching and leachate analysis using inductively coupled plasma mass spectrometry (ICP-MS). The method was validated and applied in selected locations at Pacific Northwest National Laboratory (PNNL) and the SNOLAB underground facility.
△ Less
Submitted 23 June, 2020;
originally announced June 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trap** and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Searches for electron interactions induced by new physics in the EDELWEISS-III germanium bolometers
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. Gascon,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
V. Kozlov,
H. Kraus,
V. A. Kudryavtsev,
H. Le-Sueur,
R. Maisonobe,
S. Marnieros
, et al. (17 additional authors not shown)
Abstract:
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters…
▽ More
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters $g_{ae}<1.1\times 10^{-11}$ and $g_{ae}\times g_{aN}^{\rm eff} < 3.5\times 10^{-17}$ at 90% C.L. in the massless limit. We also directly search for the absorption of bosonic dark matter particles that would constitute our local galactic halo. Limits are placed on the couplings of ALPs or hidden photon dark matter in the mass range $0.8 - 500$ keV/c$^2$. Prospects for searching for dark matter particles with masses down to 150 eV/c$^2$ using improved detectors are presented.
△ Less
Submitted 5 November, 2018; v1 submitted 7 August, 2018;
originally announced August 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Authors:
Robert Agnese,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Elham Azadbakht,
William Baker,
Samir Banik,
D'Ann Barker,
Dan Bauer,
Thomas Binder,
Michael Bowles,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Jodi Cooley,
Brett Cornell,
Priscilla Cushman,
Philippe Di Stefano,
Todd Doughty,
Eleanor Fascione,
Tali Figueroa
, et al. (72 additional authors not shown)
Abstract:
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which w…
▽ More
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
△ Less
Submitted 16 April, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Radon Daughter Plate-out Measurements at SNOLAB for Polyethylene and Copper
Authors:
Matthew Stein,
Dan Bauer,
Ray Bunker,
Rob Calkins,
Jodi Cooley,
Ben Loer,
Silvia Scorza
Abstract:
Polyethylene and copper samples were exposed to the underground air at SNOLAB for approximately three months while several environmental factors were monitored. Predictions of the radon-daughter plate-out rate are compared to the resulting surface activities, obtained from high-sensitivity measurements of alpha emissivity using the XIA UltraLo-1800 spectrometer at SMU. From these measurements, we…
▽ More
Polyethylene and copper samples were exposed to the underground air at SNOLAB for approximately three months while several environmental factors were monitored. Predictions of the radon-daughter plate-out rate are compared to the resulting surface activities, obtained from high-sensitivity measurements of alpha emissivity using the XIA UltraLo-1800 spectrometer at SMU. From these measurements, we determine an average $^{210}$Pb plate-out rate of 249 and 423 atoms/day/cm$^{2}$ for polyethylene and copper, respectively, when exposed to radon activity of 135 Bq/m$^{3}$ at SNOLAB. A time-dependent model of alpha activity is discussed for these materials placed in similar environmental conditions.
△ Less
Submitted 13 November, 2017; v1 submitted 30 August, 2017;
originally announced August 2017.
-
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (79 additional authors not shown)
Abstract:
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ (…
▽ More
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the strongest limits for WIMP--germanium-nucleus interactions for masses $>$12 GeV/$c^2$.
△ Less
Submitted 29 August, 2017;
originally announced August 2017.
-
Optimizing EDELWEISS detectors for low-mass WIMP searches
Authors:
EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
Y. **,
A. Juillard,
M. Kleifges,
V. Kozlov,
H. Kraus
, et al. (18 additional authors not shown)
Abstract:
The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely profile likelihood and boosted decision tree. Both current and achievable experimental performance are considered. The optimal str…
▽ More
The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely profile likelihood and boosted decision tree. Both current and achievable experimental performance are considered. The optimal strategy for detector optimization depends critically on whether the emphasis is put on WIMP masses below or above $\sim$ 5 GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon cross-section of $σ_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future hundred-kilogram scale experiment designed to reach the bounds imposed by the coherent scattering of solar neutrinos are also described. By improving the ionization resolution down to 50 eV$_{ee}$, we show that such an experiment installed in an even lower background environment (e.g. at SNOLAB) should allow to observe about 80 $^8$B neutrino events after discrimination.
△ Less
Submitted 11 July, 2017;
originally announced July 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Performance of the EDELWEISS-III experiment for direct dark matter searches
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
T. de Boissière,
G. Bres,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Foerster,
N. Fourches,
G. Garde,
J. Gascon,
A. Giuliani,
M. Grollier
, et al. (38 additional authors not shown)
Abstract:
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used…
▽ More
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $β$- and $α$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $α$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $γ$-ray events has been demonstrated using $γ$-calibrations with $^{133}$Ba sources leading to a value of $R_{γ{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $γ$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.
△ Less
Submitted 4 June, 2017;
originally announced June 2017.
-
Input Comparison of Radiogenic Neutron Estimates for Ultra-low Background Experiments
Authors:
J. Cooley,
K. J. Palladino,
H. Qiu,
M. Selvi,
S. Scorza,
C. Zhang
Abstract:
Ultra-low-background experiments address some of the most important open questions in particle physics, cosmology and astrophysics: the nature of dark matter, whether the neutrino is its own antiparticle, and does the proton decay. These rare event searches require well-understood and minimized backgrounds. Simulations are used to understand backgrounds caused by naturally occurring radioactivity…
▽ More
Ultra-low-background experiments address some of the most important open questions in particle physics, cosmology and astrophysics: the nature of dark matter, whether the neutrino is its own antiparticle, and does the proton decay. These rare event searches require well-understood and minimized backgrounds. Simulations are used to understand backgrounds caused by naturally occurring radioactivity in the rock and in every piece of shielding and detector material used in these experiments. Most important are processes like spontaneous fission and (α,n) reactions in material close to the detectors that can produce neutrons. A comparison study between two dedicated software packages is detailed. The cross section libraries, neutron yields, and spectra from the Mei-Zhang-Hime and the SOURCES-4A codes are presented. The resultant yields and spectra are used as inputs to direct dark matter detector toy models in GEANT4, to study the impact of their differences on background estimates and fits. Although differences in neutron yield calculations up to 50% were seen, there was no systematic difference between the Mei-Hime-Zhang and SOURCES-4A results. Neutron propagation simulations smooth differences in spectral shape and yield, and both tools were found to meet the broad requirements of the low-background community.
△ Less
Submitted 12 May, 2017;
originally announced May 2017.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
Measurement of the cosmogenic activation of germanium detectors in EDELWEISS-III
Authors:
The EDELWEISS Collaboration,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
G. Heuermann,
Y. **,
A. Juillard
, et al. (24 additional authors not shown)
Abstract:
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for…
▽ More
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for $^{65}$Zn. These results are the most accurate for these isotopes. A lower limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also presented. They are compared to model predictions present in literature and to estimates calculated with the ACTIVIA code.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach
Authors:
EDELWEISS Collaboration,
L. Hehn,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
G. Heuermann,
Y. **,
A. Juillard
, et al. (24 additional authors not shown)
Abstract:
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoi…
▽ More
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoils from $^{206}$Pb and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on Boosted Decision Trees (BDT). For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90% C.L. exclusion limit set for WIMPs with $m_χ= 4\,\mathrm{GeV/}c^2$ is $1.6 \times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above $15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in good agreement.
△ Less
Submitted 20 September, 2016; v1 submitted 12 July, 2016;
originally announced July 2016.
-
Signals induced by charge-trap** in EDELWEISS FID detectors: analytical modeling and applications
Authors:
The EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
L. Dumoulin,
K. Eitel,
N. Foerster,
N. Fourches,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
G. Heuermann,
M. De Jésus,
Y. **
, et al. (25 additional authors not shown)
Abstract:
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trap** significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID…
▽ More
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trap** significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID detectors based on the Shockley-Ramo theorem. It is used to demonstrate that veto electrodes, initially designed for the sole purpose of surface event rejection, can be used to provide a sensitivity to the depth of the energy deposits, characterize the trap** in the crystals, perform heat and ionization energy corrections and improve the ionization baseline resolutions. These procedures are applied successfully to actual data.
△ Less
Submitted 29 June, 2016; v1 submitted 26 June, 2016;
originally announced June 2016.
-
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
Authors:
EDELWEISS Collaboration,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
J. Blümer,
T. de Boissière,
G. Bres,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Foerster,
N. Fourches,
G. Garde,
J. Gascon
, et al. (42 additional authors not shown)
Abstract:
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear rec…
▽ More
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an illustration the number of observed events in the search for 5 (resp. 20) GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1 (resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times 10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a 41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints of WIMP signals from some recent experiments, thus confirming results obtained with different detection techniques.
△ Less
Submitted 9 May, 2016; v1 submitted 16 March, 2016;
originally announced March 2016.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Improved WIMP-search reach of the CDMS II germanium data
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano
, et al. (64 additional authors not shown)
Abstract:
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity n…
▽ More
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there were zero candidate events above a deposited energy of 10 keV and 6 events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and $1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$ WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
△ Less
Submitted 13 October, 2015; v1 submitted 22 April, 2015;
originally announced April 2015.
-
Dark matter effective field theory scattering in direct detection experiments
Authors:
K. Schneck,
B. Cabrera,
D. G. Cerdeno,
V. Mandic,
H. E. Rogers,
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
D. O. Caldwell,
R. Calkins,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman
, et al. (62 additional authors not shown)
Abstract:
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter paramete…
▽ More
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when develo** signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.
△ Less
Submitted 16 August, 2016; v1 submitted 11 March, 2015;
originally announced March 2015.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
Background studies for the EDELWEISS dark matter experiment
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couedo,
P. Coulter,
G. A. Cox,
M. De Jesus,
J. Domange,
A. -A. Drilien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
M. Gros
, et al. (34 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present h…
▽ More
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of 1.0-3.1 events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events ($\le0.9$), surface betas ($\le0.3$), and muon-induced neutrons ($\le0.7$), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as 14-44 events/kg/day and 0.7-1.4 events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected rate of background events in the next phase of the experiment.
△ Less
Submitted 15 May, 2013;
originally announced May 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.
-
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
E. Do Couto E Silva
, et al. (66 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206P…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
△ Less
Submitted 11 October, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Silicon detector results from the first five-tower run of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
P. C. F. Di Stefano,
E. do Couto e Silva
, et al. (65 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 k…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
△ Less
Submitted 14 September, 2013; v1 submitted 12 April, 2013;