-
Laser Interactions with Gas Jets: EMP Emission and Nozzle Damage
Authors:
Philip Wykeham Bradford,
Valeria Ospina-Bohorquez,
Michael Ehret,
Jose-Luis Henares,
Pilar Puyuelo-Valdes,
Tomasz Chodukowski,
Tadeusz Pisarczyk,
Zofia Rusiniak,
Carlos Salgado-Lopez,
Christos Vlachos,
Massimiliano Sciscio,
Martina Salvadori,
Claudio Verona,
George Hicks,
Jean-Raphael Marques,
Laurent Gremillet,
Joao Jorge Santos,
Fabrizio Consoli,
Vladimir Tikhonchuk
Abstract:
We present a theoretical model of electromagnetic pulse emission and nozzle damage from high-power laser interactions with gas jets. As hot electrons are accelerated beyond the laser channel, they produce a positively-charged plasma that expands into the ambient gas until it reaches the gas jet nozzle. A strong plasma potential leads to electrical breakdown that ionises the gas even faster than th…
▽ More
We present a theoretical model of electromagnetic pulse emission and nozzle damage from high-power laser interactions with gas jets. As hot electrons are accelerated beyond the laser channel, they produce a positively-charged plasma that expands into the ambient gas until it reaches the gas jet nozzle. A strong plasma potential leads to electrical breakdown that ionises the gas even faster than the expanding plasma ions. When contact is made between the plasma and the conducting nozzle surface, a discharge current propagates to ground and an electromagnetic pulse is radiated via an antenna emission mechanism. Damage to gas jet nozzles is caused by heating from plasma ions rather than Ohmic heating via a discharge current. Our model agrees with experimental data from experiments on proton acceleration in near-critical plasmas at the Vulcan and VEGA-3 lasers.
△ Less
Submitted 22 April, 2024; v1 submitted 28 March, 2024;
originally announced March 2024.
-
Radioisotopes production using lasers: from basic science to applications
Authors:
M. R. D. Rodrigues,
A. Bonasera,
M. Scisciò,
J. A. Pérez-Hernández,
M. Ehret,
F. Filippi,
P. L. Andreoli,
M. Huault,
H. Larreur,
D. Singappuli,
D. Molloy,
D. Raffestin,
M. Alonzo,
G. G. Rapisarda,
D. Lattuada,
G. L. Guardo,
C. Verona,
Fe. Consoli,
G. Petringa,
A. McNamee,
M. La Cognata,
S. Palmerini,
T. Carriere,
M. Cipriani,
G. Di Giorgio
, et al. (15 additional authors not shown)
Abstract:
Laser technologies improved after the understanding of the Chirped Pulse Amplification (CPA) which allows energetic laser beams to be compressed to tens of femtosecond (fs) pulse durations and focused to few $μ$m. Protons of tens of MeV can be accelerated using for instance the Target Normal Sheath Acceleration (TNSA) method and focused on secondary targets. In such conditions, nuclear reactions c…
▽ More
Laser technologies improved after the understanding of the Chirped Pulse Amplification (CPA) which allows energetic laser beams to be compressed to tens of femtosecond (fs) pulse durations and focused to few $μ$m. Protons of tens of MeV can be accelerated using for instance the Target Normal Sheath Acceleration (TNSA) method and focused on secondary targets. In such conditions, nuclear reactions can occur and radioisotopes relevant for medical purposes be produced. High repetition lasers can be used to produce enough isotopes for medical applications. This route is competitive to conventional methods mostly based on accelerators. In this paper we study the production of $^{67}$Cu, $^{63}$Zn, $^{18}$F and $^{11}$C currently used in positron emission tomography (PET) and other applications. At the same time, we study the reaction $^{10}$B(p,$α$)$^{7}$Be and $^{70}$Zn(p,4n)$^{67}$Ga to put further constraints to the proton distributions at different angles and to the reaction $^{11}$B(p,$α$)$^{8}$Be relevant for energy production. The experiment was performed at the 1 petawatt (PW) laser facility at Vega III located in Salamanca-Spain. Angular distributions of radioisotopes in the forward (with respect to the laser direction) and backward directions were measured using a High Purity Germanium Detector (HPGE). Our results are reasonably reproduced by the numerical estimates following the approach of Kimura et al. (NIMA637(2011)167)
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Plasma density profile reconstruction of a gas cell for Ionization Induced Laser Wakefield Acceleration
Authors:
F. Filippi,
L. T. Dickson,
M. Backhouse,
P. Forestier-Colleoni,
C. Gustafsson,
C. Cobo,
C. Ballage,
S. Dobosz Dufrénoy,
E. Löfquist,
G. Maynard,
C. D. Murphy,
Z. Najmudin,
F. Panza,
A. Persson,
M. Scisciò,
O. Vasilovici,
O. Lundh,
B. Cros
Abstract:
Laser-driven plasma wakefields can provide hundreds of MeV electron beam in mm-range distances potentially shrinking the dimension of the actual particle accelerators. The plasma density plays a fundamental role in the control and stability of the acceleration process, which is a key development for the future electron injector proposed by EuPRAXIA. A gas cell was designed by LPGP and LIDYL teams,…
▽ More
Laser-driven plasma wakefields can provide hundreds of MeV electron beam in mm-range distances potentially shrinking the dimension of the actual particle accelerators. The plasma density plays a fundamental role in the control and stability of the acceleration process, which is a key development for the future electron injector proposed by EuPRAXIA. A gas cell was designed by LPGP and LIDYL teams, with variable length and backing pressure, to confine the gas and tailor the gas density profile before the arrival of the laser. This cell was used during an experimental campaign with the multi TW-class laser at the Lund Laser Centre. Ionization assisted injection in a tailored density profile is used to tune the electron beam properties. During the experiment, we filled the gas cell with hydrogen mixed with different concentration of nitrogen. We also varied the backing pressure of the gas and the geometrical length of the gas cell. We used a transverse probe to acquire shadowgraphic images of the plasma and to measure the plasma electron density. Methods and results of the analysis with comparisons between shadowgraphic and interferometric images will be discussed.
△ Less
Submitted 8 May, 2023; v1 submitted 19 April, 2023;
originally announced April 2023.
-
Characterization and performance of the Apollon Short-Focal-Area facility following its commissioning at 1 PW level
Authors:
K. Burdonov,
A. Fazzini,
V. Lelasseux,
J. Albrecht,
P. Antici,
Y. Ayoul,
A. Beluze,
D. Cavanna,
T. Ceccotti,
M. Chabanis,
A. Chaleil,
S. N. Chen,
Z. Chen,
F. Consoli,
M. Cuciuc,
X. Davoine,
J. P. Delaneau,
E. d'Humières,
J-L. Dubois,
C. Evrard,
E. Filippov,
A. Freneaux,
P. Forestier-Colleoni,
L. Gremillet,
V. Horny
, et al. (23 additional authors not shown)
Abstract:
We present the results of the first commissioning phase of the ``short focal length'' area (SFA) of the Apollon laser facility (located in Saclay, France), which was performed with the first available laser beam (F2), scaled to a nominal power of one petawatt. Under the conditions that were tested, this beam delivered on target pulses of 10 J average energy and 24 fs duration. Several diagnostics…
▽ More
We present the results of the first commissioning phase of the ``short focal length'' area (SFA) of the Apollon laser facility (located in Saclay, France), which was performed with the first available laser beam (F2), scaled to a nominal power of one petawatt. Under the conditions that were tested, this beam delivered on target pulses of 10 J average energy and 24 fs duration. Several diagnostics were fielded to assess the performance of the facility. The on-target focal spot, its spatial stability, the temporal intensity profile prior to the main pulse, as well as the resulting density gradient formed at the irradiated side of solid targets, have been thoroughly characterized, with the goal of hel** users design future experiments. Emissions of energetic electrons, ions, and electromagnetic radiation were recorded, showing good laser-to-target coupling efficiency and an overall performance comparable with that of similar international facilities. This will be followed in 2022 by a further commissioning stage at the multi-petawatt level.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Acceleration of collimated 45 MeV protons by collisionless shocks driven in low-density, large-scale gradient plasmas by a 10^20 W/cm^2, 1 micron wavelength laser
Authors:
P. Antici,
E. Boella,
S. N. Chen,
D. S. Andrews,
M. Barberio,
J. Böker,
F. Cardelli,
J. L. Feugeas,
M. Glesser,
P. Nicolaï,
L. Romagnani,
M. Sciscio,
M. Starodubtsev,
O. Willi,
J. C. Kieffer,
V. Tikhonchuk,
H. Pépin,
L. O. Silva,
E. d Humières,
J. Fuchs
Abstract:
A new type of proton acceleration stemming from large-scale gradients, low-density targets, irradiated by an intense near-infrared laser is observed. The produced protons are characterized by high-energies (with a broad spectrum), are emitted in a very directional manner, and the process is associated to relaxed laser (no need for high-contrast) and target (no need for ultra-thin or expensive targ…
▽ More
A new type of proton acceleration stemming from large-scale gradients, low-density targets, irradiated by an intense near-infrared laser is observed. The produced protons are characterized by high-energies (with a broad spectrum), are emitted in a very directional manner, and the process is associated to relaxed laser (no need for high-contrast) and target (no need for ultra-thin or expensive targets) constraints. As such, this process appears quite effective compared to the standard and commonly used Target Normal Sheath Acceleration technique (TNSA), or more exploratory mechanisms like Radiation Pressure Acceleration (RPA). The data are underpinned by 3D numerical simulations which suggest that in these conditions Low Density Collisionless Shock Acceleration (LDCSA) is at play, which combines an initial Collisionless Shock Acceleration (CSA) to a boost procured by a TNSA-like sheath field in the downward density ramp of the target, which leads to an overall broad spectrum. Experiments performed at 10^20 W/cm^2 laser intensity show that LDCSA can accelerate, from ~1% critical density, mm-scale targets, up to 5x10^9 protons/MeV/sr/J with energies up to 45(+/- 5) MeV in a collimated (~6$^\circ$ half-angle) manner.
△ Less
Submitted 8 August, 2017;
originally announced August 2017.