-
Electron counting capacitance standard and quantum metrology triangle experiments at PTB
Authors:
H Scherer,
J Schurr,
F J Ahlers
Abstract:
This paper summarizes the final results of the electron counting capacitance standard experiment at the Physikalisch-Technische Bundesanstalt (PTB) achieved since the publication of a preliminary result in 2012. All systematic uncertainty contributions were experimentally quantified and are discussed. Frequency-dependent measurements on the 1 pF cryogenic capacitor were performed using a high-prec…
▽ More
This paper summarizes the final results of the electron counting capacitance standard experiment at the Physikalisch-Technische Bundesanstalt (PTB) achieved since the publication of a preliminary result in 2012. All systematic uncertainty contributions were experimentally quantified and are discussed. Frequency-dependent measurements on the 1 pF cryogenic capacitor were performed using a high-precision transformer-based capacitance bridge with a relative uncertainty of 0.03 microF/F. The results revealed a crucial problem related to the capacitor, which hampered realizing the quantum metrology triangle with an accuracy corresponding to a combined total uncertainty of better than a few parts per million and eventually caused the discontinuation of the experiment at PTB. This paper provides a conclusion on the implications for future quantum metrology triangle experiments from the latest CODATA adjustment of fundamental constants, and summarizes perspectives and outlooks on future quantum metrology triangle experiments based on topical developments in small-current metrology.
△ Less
Submitted 4 April, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
Nonequilibrium mesoscopic conductance fluctuations as the origin of 1/f noise in epitaxial graphene
Authors:
Cay-Christian Kalmbach,
Franz Josef Ahlers,
Jürgen Schurr,
André Müller,
Juraj Feilhauer,
Mattias Kruskopf,
Klaus Pierz,
Frank Hohls,
Rolf J. Haug
Abstract:
We investigate the 1/f noise properties of epitaxial graphene devices at low temperatures as a function of temperature, current and magnetic flux density. At low currents, an exponential decay of the 1/f noise power spectral density with increasing temperature is observed that indicates mesoscopic conductance fluctuations as the origin of 1/f noise at temperatures below 50 K. At higher currents, d…
▽ More
We investigate the 1/f noise properties of epitaxial graphene devices at low temperatures as a function of temperature, current and magnetic flux density. At low currents, an exponential decay of the 1/f noise power spectral density with increasing temperature is observed that indicates mesoscopic conductance fluctuations as the origin of 1/f noise at temperatures below 50 K. At higher currents, deviations from the typical quadratic current dependence and the exponential temperature dependence occur as a result of nonequilibrium conditions due to current heating. By applying the theory of Kubakaddi [S. S. Kubakaddi, Phys. Rev. B 79, 075417 (2009)], a model describing the 1/f noise power spectral density of nonequilibrium mesoscopic conductance fluctuations in epitaxial graphene is developed and used to determine the energy loss rate per carrier. In the regime of Shubnikov-de Haas oscillations a strong increase of 1/f noise is observed, which we attribute to an additional conductance fluctuation mechanism due to localized states in quantizing magnetic fields. When the device enters the regime of quantized Hall resistance, the 1/f noise vanishes. It reappears if the current is increased and the quantum Hall breakdown sets in.
△ Less
Submitted 16 September, 2016;
originally announced September 2016.
-
Reflections on a Measurement of the Gravitational Constant Using a Beam Balance and 13 Tons of Mercury
Authors:
S. Schlamminger,
R. E. Pixley,
F. Nolting,
J. Schurr,
U. Straumann
Abstract:
In 2006, a final result of a measurement of the gravitational constant $G$ performed by researchers at the University of Zürich was published. A value of $G=6.674\,252(122)\times 10^{-11}\,\mbox{m}^3\,\mbox{kg}^{-1}\,\mbox{s}^{-2}$ was obtained after an experimental effort that lasted over one decade. Here, we briefly summarize the measurement and discuss the strengths and weaknesses of this appro…
▽ More
In 2006, a final result of a measurement of the gravitational constant $G$ performed by researchers at the University of Zürich was published. A value of $G=6.674\,252(122)\times 10^{-11}\,\mbox{m}^3\,\mbox{kg}^{-1}\,\mbox{s}^{-2}$ was obtained after an experimental effort that lasted over one decade. Here, we briefly summarize the measurement and discuss the strengths and weaknesses of this approach.
△ Less
Submitted 19 July, 2014;
originally announced July 2014.
-
Towards a Graphene-Based Quantum Impedance Standard
Authors:
C. -C. Kalmbach,
J. Schurr,
F. J. Ahlers,
A. Müller,
S. Novikov,
N. Lebedeva,
A. Satrapinski
Abstract:
Precision measurements of the quantum Hall resistance with alternating current (ac) in the kHz range were performed on epitaxial graphene in order to assess its suitability as a quantum standard of impedance. The quantum Hall plateaus measured with alternating current were found to be flat within one part in 10^7. This is much better than for plain GaAs quantum Hall devices and shows that the magn…
▽ More
Precision measurements of the quantum Hall resistance with alternating current (ac) in the kHz range were performed on epitaxial graphene in order to assess its suitability as a quantum standard of impedance. The quantum Hall plateaus measured with alternating current were found to be flat within one part in 10^7. This is much better than for plain GaAs quantum Hall devices and shows that the magnetic-flux-dependent capacitive ac losses of the graphene device are less critical. The observed frequency dependence of about -8x10^-8/kHz is comparable in absolute value to the positive frequency dependence of plain GaAs devices, but the negative sign is attributed to stray capacitances which we believe can be minimized by a careful design of the graphene device. Further improvements thus may lead to a simpler and more user-friendly quantum standard for both resistance and impedance.
△ Less
Submitted 20 August, 2014; v1 submitted 24 June, 2014;
originally announced June 2014.
-
Compendium for precise ac measurements of the quantum Hall resistance
Authors:
F J Ahlers,
B Jeanneret,
F Overney,
J Schurr,
B M Wood
Abstract:
In view of the progress achieved in the field of the ac quantum Hall effect, the Working Group of the Comite Consultatif d'Electricite et Magnetisme (CCEM) on the AC Quantum Hall Effect asked the authors of this paper to write a compendium which integrates their experiences with ac measurements of the quantum Hall resistance. In addition to the important early work performed at the Bureau Intern…
▽ More
In view of the progress achieved in the field of the ac quantum Hall effect, the Working Group of the Comite Consultatif d'Electricite et Magnetisme (CCEM) on the AC Quantum Hall Effect asked the authors of this paper to write a compendium which integrates their experiences with ac measurements of the quantum Hall resistance. In addition to the important early work performed at the Bureau International des Poids et Mesures and the National Physical Laboratory, UK, further experience has been gained during a collaboration of the authors' institutes NRC, METAS, and PTB, and excellent agreement between the results of different national metrology institutes has been achieved. This compendium summarizes the present state of the authors' knowledge and reviews the experiences, tests and precautions that the authors have employed to achieve accurate measurements of the ac quantum Hall effect. This work shows how the ac quantum Hall effect can be reliably used as a quantum standard of ac resistance having a relative uncertainty of a few parts in 10^8.
△ Less
Submitted 1 July, 2009; v1 submitted 25 March, 2009;
originally announced March 2009.
-
A Measurement of Newton's Gravitational Constant
Authors:
St. Schlamminger,
E. Holzschuh,
W. Kündig,
F. Nolting,
R. E. Pixley,
J. Schurr,
U. Straumann
Abstract:
A precision measurement of the gravitational constant $G$ has been made using a beam balance. Special attention has been given to determining the calibration, the effect of a possible nonlinearity of the balance and the zero-point variation of the balance. The equipment, the measurements and the analysis are described in detail. The value obtained for G is 6.674252(109)(54) 10^{-11} m3 kg-1 s-2.…
▽ More
A precision measurement of the gravitational constant $G$ has been made using a beam balance. Special attention has been given to determining the calibration, the effect of a possible nonlinearity of the balance and the zero-point variation of the balance. The equipment, the measurements and the analysis are described in detail. The value obtained for G is 6.674252(109)(54) 10^{-11} m3 kg-1 s-2. The relative statistical and systematic uncertainties of this result are 16.3 10^{-6} and 8.1 10^{-6}, respectively.
△ Less
Submitted 7 September, 2006;
originally announced September 2006.