-
Gain suppression study on LGADs at the CENPA tandem accelerator
Authors:
S. Braun,
Q. Buat,
J. Ding,
P. Kammel,
S. M. Mazza,
F. McKinney-Martinez,
A. Molnar,
C. Lansdell,
J. Ott,
A. Seiden,
B. Schumm,
Y. Zhao
Abstract:
Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge in the use of LGADs, studied by several research groups, is the gain suppression mechanism for large localized charge deposits. Using the CENPA Tandem accelerator at the University of Washington, the response of the LGADs…
▽ More
Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge in the use of LGADs, studied by several research groups, is the gain suppression mechanism for large localized charge deposits. Using the CENPA Tandem accelerator at the University of Washington, the response of the LGADs to MeV-range energy deposits from a proton beam was studied. Two LGAD prototypes and a PIN diode were characterized, and the gain of the devices was determined as a function of bias voltage, incidence beam angle and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. %At the center of the experiment, a high-granularity active target (ATAR) will stop the pion and characterize its decay. A range of deposited charge from Minimum Ionizing Particle (MIP, few 10s of KeV) from positrons to several MeV from the stop** pions/muons is expected in PIONEER; the detection and separation of close-by hits in such a wide dynamic range will be a main challenge of the experiment. To achieve this goal, the gain suppression mechanism has to be understood fully.
△ Less
Submitted 3 May, 2024;
originally announced May 2024.
-
Long-Distance Signal Propagation in AC-LGAD
Authors:
Casey Bishop,
Ayan Das,
Jane Ding,
Matthew Gignac,
Forest Martinez-McKinney,
Simone M. Mazza,
Adam Molnar,
Noah Nagel,
Mohammad Nizam,
Jennifer Ott,
Hartmut F. -W. Sadrozinski,
Bruce Schumm,
Abraham Seiden,
Taylor Shin,
Andrew Summerell,
Max Wilder,
Yuzhan Zhao
Abstract:
We investigate the signal propagation in AC-LGAD (aka RSD), which are LGAD with a common N+ layer and segmented AC-coupled readout contacts, by measuring response to IR laser TCT on a large selection of AC-LGAD with strip readout. The interest for this topic derives from the realization that while large charge sharing between neighboring strips is essential for good position resolution, large shar…
▽ More
We investigate the signal propagation in AC-LGAD (aka RSD), which are LGAD with a common N+ layer and segmented AC-coupled readout contacts, by measuring response to IR laser TCT on a large selection of AC-LGAD with strip readout. The interest for this topic derives from the realization that while large charge sharing between neighboring strips is essential for good position resolution, large sharing beyond the next neighbor generates background signals which in general are detrimental to the sensor goal of low occupancy. Using AC-LGAD with strip readout produced by Hamamatsu Photonics (HPK), we evaluate the effects of a variety of sensor properties, including geometrical parameters (strip length, width), process parameters like the N+ layer resistivity, the coupling capacitance, and the thickness of the bulk on the signal sharing and the position resolution.
△ Less
Submitted 22 May, 2024; v1 submitted 1 March, 2024;
originally announced March 2024.
-
Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes
Authors:
S. M. Mazza,
G. Saito,
Y. Zhao,
T. Kirkes,
N. Yoho,
D. Yerdea,
N. Nagel,
J. Ott,
M. Nizam,
M. Leite,
M. Moralles,
H. F. -W. Sadrozinski,
A. Seiden,
B. Schumm,
F. McKinney-Martinez,
G. Giacomini,
W. Chen
Abstract:
The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was 11-2, with a nominal beam size of 3 cm x 0.5 cm, a repetition rate of 500 MHz, and very monochromatic. LGADs of different thicknesses and gain layer configurations…
▽ More
The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was 11-2, with a nominal beam size of 3 cm x 0.5 cm, a repetition rate of 500 MHz, and very monochromatic. LGADs of different thicknesses and gain layer configurations were read out using fast amplification boards and digitized with a fast oscilloscope. Standard PiN devices were characterized as well. The devices' energy resolution and time resolution as a function of X-ray energy were measured. The charge collection and multiplication mechanism were simulated using TCAD Sentaurus, and the results were compared with the collected data.
△ Less
Submitted 1 September, 2023; v1 submitted 27 June, 2023;
originally announced June 2023.
-
TCAD simulation of AC-LGADs
Authors:
M. Nizam,
K. W. Shin,
S. M. Mazza,
J. Ott,
A. Seiden,
B. Schumm,
Y. Zhao
Abstract:
Low Gain Avalanche Detectors (LGADs) are thin silicon detectors with moderate internal signal amplification and time resolution as good as 17 ps for minimum ionizing particles. However, the current major limiting factor in granularity is due to protection structures preventing breakdown caused by high electric fields at the edge of the segmented implants. This structure, called Junction Terminatio…
▽ More
Low Gain Avalanche Detectors (LGADs) are thin silicon detectors with moderate internal signal amplification and time resolution as good as 17 ps for minimum ionizing particles. However, the current major limiting factor in granularity is due to protection structures preventing breakdown caused by high electric fields at the edge of the segmented implants. This structure, called Junction Termination Extension (JTE), causes a region of 50-100~\um\ of inactive space. Therefore, the granularity of LGAD sensors is currently limited to the mm scale. A solution would be AC-coupled LGADs (AC-LGADs) which can provide spatial resolution on the 10's of um scale. This is achieved by an un-segmented (p-type) gain layer and (n-type) N-layer, and a dielectric layer separating the metal readout pads. The high spatial precision is achieved by using the information from multiple pads, exploiting the intrinsic charge-sharing capabilities of the AC-LGAD provided by the common N-layer. TCAD software (Silvaco and Sentaurus) was used to simulate the behavior of AC-LGADs. A set of simulated devices was prepared by changing several parameters in the sensor: N+ resistivity, strip length, and bulk thickness.
△ Less
Submitted 24 May, 2023;
originally announced May 2023.
-
First Test Results of the Trans-Impedance Amplifier Stage of the Ultra-fast HPSoC ASIC
Authors:
C. Chock,
K. Flood,
L. Macchiarulo,
I. Mostafanezhad,
R. Perron,
D. Uehara,
F. Martinez-Mckinney,
A. Martinez- Rojas,
S. Mazza,
M. Nizam,
J. Ott,
E. Ryan,
H. F. -W. Sadrozinski,
B. Schumm,
A. Seiden,
K. Shin,
M. Tarka,
M. Wilder,
Y. Zhao
Abstract:
We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 um thick AC-LGAD. The evaluation of the analog front end with \b{eta}-particles im**ing on 3x3 AC-LGAD arrays (500 um pitch, 200x200 um2 metal) confirms a fast output rise time of 600 ps and good timing performance…
▽ More
We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 um thick AC-LGAD. The evaluation of the analog front end with \b{eta}-particles im**ing on 3x3 AC-LGAD arrays (500 um pitch, 200x200 um2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.
△ Less
Submitted 10 December, 2022; v1 submitted 17 October, 2022;
originally announced October 2022.
-
Solid State Detectors and Tracking for Snowmass
Authors:
A. Affolder,
A. Apresyan,
S. Worm,
M. Albrow,
D. Ally,
D. Ambrose,
E. Anderssen,
N. Apadula,
P. Asenov,
W. Armstrong,
M. Artuso,
A. Barbier,
P. Barletta,
L. Bauerdick,
D. Berry,
M. Bomben,
M. Boscardin,
J. Brau,
W. Brooks,
M. Breidenbach,
J. Buckley,
V. Cairo,
R. Caputo,
L. Carpenter,
M. Centis-Vignali
, et al. (110 additional authors not shown)
Abstract:
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the…
▽ More
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).
△ Less
Submitted 19 October, 2022; v1 submitted 8 September, 2022;
originally announced September 2022.
-
Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. Di Canto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than…
▽ More
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.
△ Less
Submitted 10 March, 2022;
originally announced March 2022.
-
PIONEER: Studies of Rare Pion Decays
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. DiCanto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the c…
▽ More
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stop** target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.
△ Less
Submitted 7 March, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.
-
Student-created physics problems as an independent and equitable assessment tool
Authors:
Bruce A. Schumm,
Joy Ishii,
Colin G. West
Abstract:
Traditional high-stakes summative assessments--timed, in-class exams accounting for a large percentage of the term's overall grade--have often received criticism from the educational community. Such assessments tend to prize a particular "narrow bundle of skills", and have been shown in some contexts to produce disparate outcomes between different demographic groups. Alternative low-stakes assessm…
▽ More
Traditional high-stakes summative assessments--timed, in-class exams accounting for a large percentage of the term's overall grade--have often received criticism from the educational community. Such assessments tend to prize a particular "narrow bundle of skills", and have been shown in some contexts to produce disparate outcomes between different demographic groups. Alternative low-stakes assessments have shown potential to improve student engagement and close demographic gaps. In this paper, we document our use of an alternative form of assessment, in which students were asked to create and solve a problem of their own design.
△ Less
Submitted 14 February, 2022;
originally announced February 2022.
-
Tuning of gain layer do** concentration and Carbon implantation effect on deep gain layer
Authors:
S. M. Mazza,
C. Gee,
Y. Zhao,
R. Padilla,
E. Ryan,
N. Tournebise,
B. Darby,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
B. Schumm,
V. Cindro,
G. Kramberger,
I. Mandić,
M. Mikuž,
M. Zavrtanik,
R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
V. Sola,
A. Staiano,
M. Boscardin,
G. F. Della Betta,
F. Ficorella
, et al. (2 additional authors not shown)
Abstract:
Next generation Low Gain Avalanche Diodes (LGAD) produced by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with ~1MeV neutrons at the JSI facility in Ljubljana. Sensors were irradiated to a maximum 1-MeV equivalent fluence of 2.5E15 Neq/cm2. The sensors analysed in this paper are an improvement after the lessons learned from previous FBK and…
▽ More
Next generation Low Gain Avalanche Diodes (LGAD) produced by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with ~1MeV neutrons at the JSI facility in Ljubljana. Sensors were irradiated to a maximum 1-MeV equivalent fluence of 2.5E15 Neq/cm2. The sensors analysed in this paper are an improvement after the lessons learned from previous FBK and HPK productions that were already reported in precedent papers. The gain layer of HPK sensors was fine-tuned to optimize the performance before and after irradiation. FBK sensors instead combined the benefit of Carbon infusion and deep gain layer to further the radiation hardness of the sensors and reduced the bulk thickness to enhance the timing resolution. The sensor performance was measured in charge collection studies using \b{eta}-particles from a 90Sr source and in capacitance-voltage scans (C-V) to determine the bias to deplete the gain layer. The collected charge and the timing resolution were measured as a function of bias voltage at -30C. Finally a correlation is shown between the bias voltage to deplete the gain layer and the bias voltage needed to reach a certain amount of gain in the sensor. HPK sensors showed a better performance before irradiation while maintaining the radiation hardness of the previous production. FBK sensors showed exceptional radiation hardness allowing a collected charge up to 10 fC and a time resolution of 40 ps at the maximum fluence.
△ Less
Submitted 31 January, 2022; v1 submitted 21 January, 2022;
originally announced January 2022.
-
Inter-pad dead regions of irradiated FBK Low Gain Avalanche Detectors
Authors:
B. Darby,
S. M. Mazza,
F. McKinney-Martinez,
R. Padilla,
H. F. -W. Sadrozinski,
A. Seiden,
B. Schumm,
M. Wilder,
Y. Zhao,
R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
V. Sola,
A. Staiano,
V. Cindro,
G. Kranberger,
I. Mandiz,
M. Mikuz,
M. Zavtranik,
M. Boscardin,
G. F. Della Betta,
F. Ficorella,
L. Pancheri,
G. Paternoster
Abstract:
Low Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer. LGADs manufactured by Fondazione Bruno Kessler (FBK) were tested before and after irradiation with neutrons. In this study, the Inter-pad distances (IPDs), defined as the width of the distances between pads, were measured with a TCT laser system. The response of the laser was tuned using $β$-pa…
▽ More
Low Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer. LGADs manufactured by Fondazione Bruno Kessler (FBK) were tested before and after irradiation with neutrons. In this study, the Inter-pad distances (IPDs), defined as the width of the distances between pads, were measured with a TCT laser system. The response of the laser was tuned using $β$-particles from a 90Sr source. These insensitive "dead zones" are created by a protection structure to avoid breakdown, the Junction Termination Extension (JTE), which separates the pads. The effect of neutron radiation damage at \fluence{1.5}{15}, and \fluence{2.5}{15} on IPDs was studied. These distances are compared to the nominal distances given from the vendor, it was found that the higher fluence corresponds to a better matching of the nominal IPD.
△ Less
Submitted 19 September, 2022; v1 submitted 24 November, 2021;
originally announced November 2021.
-
A new approach to achieving high granularity for silicon diode detectors with impact ionization gain
Authors:
S. Ayyoub,
C. Gee,
R. Islam,
S. M. Mazza,
B. Schumm,
A. Seiden,
Y. Zhao
Abstract:
Low Gain Avalanche Diodes (LGADs) are thin (20-50 $μm$)silicon di ode sensors with modest internal gain (typically 5 to 50) and exceptional time resolution (17 $ps$ to 50 $ps$). However, the granularity of such devices is limited to the millimeter scale due to the need to include protection structures at the boundaries of the readout pads to avoid premature breakdown due to large local electric fi…
▽ More
Low Gain Avalanche Diodes (LGADs) are thin (20-50 $μm$)silicon di ode sensors with modest internal gain (typically 5 to 50) and exceptional time resolution (17 $ps$ to 50 $ps$). However, the granularity of such devices is limited to the millimeter scale due to the need to include protection structures at the boundaries of the readout pads to avoid premature breakdown due to large local electric fields. In this paper we present a new approach -- the Deep-Junction LGAD (DJ-LGAD) -- that decouples the high-field gain region from the readout plane. This approach is expected to improve the achievable LGAD granularity to the tens-of-micron scale while maintaining direct charge collection on the segmented electrodes.
△ Less
Submitted 2 January, 2021;
originally announced January 2021.
-
Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept
Authors:
M. Jadhav,
W. Armstrong,
I. Cloet,
S. Joosten,
S. M. Mazza,
J. Metcalfe,
Z. -E. Meziani,
H. F. -W. Sadrozinski,
B. Schumm,
A. Seiden
Abstract:
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the…
▽ More
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 micro-m thick LGADs at -30 degree celsius with a precision of 14.3 ps (uncertainty 1.5 ps).
△ Less
Submitted 19 February, 2021; v1 submitted 6 October, 2020;
originally announced October 2020.
-
Potential for Improved Time Resolution Using Very Thin Ultra-Fast Silicon Detectors (UFSDs)
Authors:
A. Seiden,
H. Ren,
Y. **,
S. Christie,
Z. Galloway,
C. Gee,
C. Labitan,
M. Lockerby,
F. Martinez-McKinney,
S. M. Mazza,
R. Padilla,
H. F. -W. Sadrozinski,
B. Schumm,
M. Wilder,
W. Wyatt,
Y. Zhao,
N. Cartiglia
Abstract:
Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain allows excellent time measurement for im**ing minimum ionizing charged particles. An important design consideration is the sensor thickness, which has a stron…
▽ More
Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain allows excellent time measurement for im**ing minimum ionizing charged particles. An important design consideration is the sensor thickness, which has a strong impact on the achievable time resolution. We present the result of measurements for LGADs of thickness between 20 micro-m and 50 micro-m. The data are fit to a formula that captures the impact of both electronic jitter and Landau fluctuations on the time resolution. The data illustrate the importance of having a saturated electron drift velocity and a large signal-to-noise in order to achieve good time resolution. Sensors of 20 micro-m thickness offer the potential of 10 to 15 ps time resolution per measurement, a significant improvement over the value for the 50 micro-m sensors that have been typically used to date.
△ Less
Submitted 24 February, 2021; v1 submitted 7 June, 2020;
originally announced June 2020.
-
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
Authors:
X. Shi,
M. K. Ayoub,
J. Barreiro Guimarães da Costa,
H. Cui,
R. Kiuchi,
Y. Fan,
S. Han,
Y. Huang,
M. **g,
Z. Liang,
B. Liu,
J. Liu,
F. Lyu,
B. Qi,
K. Ran,
L. Shan,
L. Shi,
Y. Tan,
K. Wu,
S. Xiao,
T. Yang,
Y. Yang,
C. Yu,
M. Zhao,
X. Zhuang
, et al. (52 additional authors not shown)
Abstract:
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the co…
▽ More
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Effect of deep gain layer and Carbon infusion on LGAD radiation hardness
Authors:
R Padilla,
C. Labitan,
Z. Galloway,
C. Gee,
S. M. Mazza,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
B. Schumm,
M. Wilder,
Y. Zhao,
H. Ren,
Y. **,
M. Lockerby,
V. Cindro,
G. Kramberger,
I. Mandiz,
M. Mikuz,
M. Zavrtanik,
R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
V. Sola,
A. Staiano
Abstract:
The properties of 50 um thick Low Gain Avalanche Diode (LGAD) detectors manufactured by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with 1 MeV neutrons. Their performance were measured in charge collection studies using b-particles from a 90Sr source and in capacitance-voltage scans (C-V) to determine the bias to deplete the gain layer. Car…
▽ More
The properties of 50 um thick Low Gain Avalanche Diode (LGAD) detectors manufactured by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with 1 MeV neutrons. Their performance were measured in charge collection studies using b-particles from a 90Sr source and in capacitance-voltage scans (C-V) to determine the bias to deplete the gain layer. Carbon infusion to the gain layer of the sensors was tested by FBK in the UFSD3 production. HPK instead produced LGADs with a very thin, highly doped and deep multiplication layer. The sensors were exposed to a neutron fluence from 4e14 neq/cm2 to 4e15 neq/cm2. The collected charge and the timing resolution were measured as a function of bias voltage at -30C, furthermore the profile of the capacitance over voltage of the sensors was measured.
△ Less
Submitted 27 July, 2020; v1 submitted 10 April, 2020;
originally announced April 2020.
-
Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
Authors:
X. Yang,
S. Alderweireldt,
N. Atanov,
M. K. Ayoub,
J. Barreiro Guimaraes da Costa,
L. Castillo Garcia,
H. Chen,
S. Christie,
V. Cindro,
H. Cui,
G. D'Amen,
Y. Davydov,
Y. Y. Fan,
Z. Galloway,
J. J. Ge,
C. Gee,
G. Giacomini,
E. L. Gkougkousis,
C. Grieco,
S. Grinstein,
J. Grosse-Knetter,
S. Guindon,
S. Han,
A. Howard,
Y. P. Huang
, et al. (54 additional authors not shown)
Abstract:
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising…
▽ More
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Experimental Study of Acceptor Removal in UFSD
Authors:
Y. **,
H. Ren,
S. Christie,
Z. Galloway,
C. Gee,
C. Labitan,
M. Lockerby,
F. Martinez-McKinney,
S. M. Mazza,
R. Padilla,
H. F. -W. Sadrozinski,
B. Schumm,
A. Seiden,
M. Wilder,
W. Wyatt,
Y. Zhao,
R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
F. Siviero,
V. Sola,
M. Tornago,
V. Cindro,
A. Howard
, et al. (3 additional authors not shown)
Abstract:
The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with C-V measurements of the do** concentration and with measurements of charge collection using charged particles. We find a perfect linear correlation between t…
▽ More
The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with C-V measurements of the do** concentration and with measurements of charge collection using charged particles. We find a perfect linear correlation between the bias voltage to deplete the gain layer determined with C-V and the bias voltage to collect a defined charge, measured with charge collection. An example for the usefulness of this correlation is presented.
△ Less
Submitted 16 September, 2020; v1 submitted 16 March, 2020;
originally announced March 2020.
-
Signal Development for Saturated Ultrafast Sensors with Impact Ionization Gain
Authors:
Bruce A. Schumm
Abstract:
A closed-form approximate expression is presented for the short time-frame development of silicon diode sensor signals in the context of high frame-rate detection of incident X-ray fluxes, in the limit that the X-ray absorption profile generates a longitudinally-uniform distribution of electron-hole pairs in the detector bulk. The expression represents the immediate time development of signals fro…
▽ More
A closed-form approximate expression is presented for the short time-frame development of silicon diode sensor signals in the context of high frame-rate detection of incident X-ray fluxes, in the limit that the X-ray absorption profile generates a longitudinally-uniform distribution of electron-hole pairs in the detector bulk. The expression represents the immediate time development of signals from diode sensors both with (LGAD) and without (PIN) gain, and presents a temporal scale associated with the onset of gain. Principles limiting the detection frame rate in the presence of electronic readout noise are discussed. Making use of an elemental simulation, the relative advantage of LGAD vs. PIN diode sensors is explored as a function of the effective electronic collection time. It is found that for an idealized LGAD sensor with a gain of 30, the gain provided by impact ionization yields an advantage relative to PIN diode sensors for frame rates as high as 10 GHz.
△ Less
Submitted 1 March, 2020; v1 submitted 14 August, 2019;
originally announced August 2019.
-
New Technologies for Discovery
Authors:
Z. Ahmed,
A. Apresyan,
M. Artuso,
P. Barry,
E. Bielejec,
F. Blaszczyk,
T. Bose,
D. Braga,
S. A. Charlebois,
A. Chatterjee,
A. Chavarria,
H. -M. Cho,
S. Dalla Torre,
M. Demarteau,
D. Denisov,
M. Diefenthaler,
A. Dragone,
F. Fahim,
C. Gee,
S. Habib,
G. Haller,
J. Hogan,
B. J. P. Jones,
M. Garcia-Sciveres,
G. Giacomini
, et al. (58 additional authors not shown)
Abstract:
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by hi…
▽ More
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.
△ Less
Submitted 10 August, 2019; v1 submitted 31 July, 2019;
originally announced August 2019.
-
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
O. Borysov,
M. Borysova,
I. Bozovic- Jelisavcic,
W. Daniluk,
D. Dannheim,
M. Demichev,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempelb,
H. Henschel,
M. Idzik,
A. Ignatenkoc,
A. Ishikawa,
A. Joffe,
G. Kacarevic,
S. Kananov,
O. Karachebanb
, et al. (29 additional authors not shown)
Abstract:
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi…
▽ More
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
△ Less
Submitted 25 October, 2019; v1 submitted 29 December, 2018;
originally announced December 2018.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
Paul Anderson,
Wyatt Crockett,
Luc D'Hauthuille,
Vitaliy Fadeyev,
Caleb Fink,
Cesar Gonzalez-Renteria,
Benjamin Gruey,
Jane Gunnell,
Forest Martinez-McKinney,
Greg Rischbieter,
Kyle Rocha,
Bruce A. Schumm,
Edwin Spencer,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e$^+$e$^-$ `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on prior highlights and recent results of SLAC Experiment T-506, for which several different types of semiconductor sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, significant post-irradiation charge collection was observed for doses of several hundred Mrad.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
A Study of the Impact of High Cross Section ILC Processes on the SiD Detector Design
Authors:
Timothy Barklow,
Luc d`Hautuille,
Christopher Milke,
Bruce Schumm,
Anne Schütz,
Marcel Stanitzki,
Jan Strube
Abstract:
The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs created by the interaction of the colliding beams' electromagnetic fields. In order to provide hermeticity and sensitivity to beam targeting parameters, a forward Be…
▽ More
The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs created by the interaction of the colliding beams' electromagnetic fields. In order to provide hermeticity and sensitivity to beam targeting parameters, a forward Beamline Calorimeter (BeamCal) is being designed that will provide coverage down to 5 mrad from the outgoing beam trajectory, and intercept the majority of this pair background. Using the SiD simulation framework, the effect of this pair background on the SiD detector components, especially the vertex detector (VXD) and forward electromagnetic calorimeter (FCAL), is explored. In the case of the FCAL, backgrounds from Bhabha and two-photon processes are also considered. The consequence of several variants of the BeamCal geometry and ILC interaction region configuration are considered for both the vertex detector and BeamCal performance.
△ Less
Submitted 25 September, 2016;
originally announced September 2016.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
George Courcoubetis,
Wyatt Crockett,
Vitaliy Fadeyev,
Caleb Fink,
Nikolas Guillemaud,
Cesar Gonzalez Renteria,
Benjamin Gruey,
Patrick LaBarre,
Forest Martinez-McKinney,
Greg Rischbieter,
Bruce A. Schumm,
Edwin Spencer,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode and gallium-arsenide sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 270 Mrad.
△ Less
Submitted 27 February, 2016;
originally announced February 2016.
-
First Observation of CP Violation in B0->D(*)CP h0 Decays by a Combined Time-Dependent Analysis of BaBar and Belle Data
Authors:
The BaBar,
Belle Collaborations,
:,
A. Abdesselam,
I. Adachi,
A. Adametz,
T. Adye,
H. Ahmed,
H. Aihara,
S. Akar,
M. S. Alam,
J. Albert,
S. Al Said,
R. Andreassen,
C. Angelini,
F. Anulli,
K. Arinstein,
N. Arnaud,
D. M. Asner,
D. Aston,
V. Aulchenko,
T. Aushev,
R. Ayad,
V. Babu,
I. Badhrees
, et al. (450 additional authors not shown)
Abstract:
We report a measurement of the time-dependent CP asymmetry of B0->D(*)CP h0 decays, where the light neutral hadron h0 is a pi0, eta or omega meson, and the neutral D meson is reconstructed in the CP eigenstates K+ K-, K0S pi0 or K0S omega. The measurement is performed combining the final data samples collected at the Y(4S) resonance by the BaBar and Belle experiments at the asymmetric-energy B fac…
▽ More
We report a measurement of the time-dependent CP asymmetry of B0->D(*)CP h0 decays, where the light neutral hadron h0 is a pi0, eta or omega meson, and the neutral D meson is reconstructed in the CP eigenstates K+ K-, K0S pi0 or K0S omega. The measurement is performed combining the final data samples collected at the Y(4S) resonance by the BaBar and Belle experiments at the asymmetric-energy B factories PEP-II at SLAC and KEKB at KEK, respectively. The data samples contain ( 471 +/- 3 ) x 10^6 BB pairs recorded by the BaBar detector and ( 772 +/- 11 ) x 10^6, BB pairs recorded by the Belle detector. We measure the CP asymmetry parameters -eta_f S = +0.66 +/- 0.10 (stat.) +/- 0.06 (syst.) and C = -0.02 +/- 0.07 (stat.) +/- 0.03 (syst.). These results correspond to the first observation of CP violation in B0->D(*)CP h0 decays. The hypothesis of no mixing-induced CP violation is excluded in these decays at the level of 5.4 standard deviations.
△ Less
Submitted 20 July, 2015; v1 submitted 15 May, 2015;
originally announced May 2015.
-
Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
George Courcoubetis,
Wyatt Crockett,
Vitaliy Fadeyev,
Thomas Kelley,
Forest Martinez-McKinney,
Bruce A. Schumm,
Edwin Spencer,
Vivian Tang,
Max Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower-max are expected to reach 100 MRad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower-max are expected to reach 100 MRad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode and gallium-arsenide sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-10.6 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 220 MRad.
△ Less
Submitted 25 March, 2015;
originally announced March 2015.
-
ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
D. Avila,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Bergholz,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
L. Dumitru,
K. Elsener,
V. Fadeyev,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
H. Henschel
, et al. (44 additional authors not shown)
Abstract:
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens…
▽ More
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
△ Less
Submitted 1 June, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
The Physics of the B Factories
Authors:
A. J. Bevan,
B. Golob,
Th. Mannel,
S. Prell,
B. D. Yabsley,
K. Abe,
H. Aihara,
F. Anulli,
N. Arnaud,
T. Aushev,
M. Beneke,
J. Beringer,
F. Bianchi,
I. I. Bigi,
M. Bona,
N. Brambilla,
J. B rodzicka,
P. Chang,
M. J. Charles,
C. H. Cheng,
H. -Y. Cheng,
R. Chistov,
P. Colangelo,
J. P. Coleman,
A. Drutskoy
, et al. (2009 additional authors not shown)
Abstract:
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary…
▽ More
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary version of the Physics of the B Factories book. This uses the notation alpha, beta, gamma for the angles of the Unitarity Triangle. The nominal version uses the notation phi_1, phi_2 and phi_3. Please cite this work as Eur. Phys. J. C74 (2014) 3026.
△ Less
Submitted 31 October, 2015; v1 submitted 24 June, 2014;
originally announced June 2014.
-
Initial Results of a Silicon Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Authors:
R. Band,
V. Fadeyev,
R. C. Field,
S. Key,
T. Kim,
T. Markiewicz,
F. Martinez-McKinney,
T. Maruyama,
K. Mistry,
R. Nidumolu,
B. A. Schumm,
E. Spencer,
C. Timlin,
M. Wilder
Abstract:
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower-max are expected to reach 100 MRad per year…
▽ More
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower-max are expected to reach 100 MRad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-10.6 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 220 MRad.
△ Less
Submitted 11 February, 2014;
originally announced February 2014.
-
Evidence for the decay B0 --> omega omega and search for B0 --> omega phi
Authors:
The BABAR Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
E. Grauges,
A. Palano,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
M. J. Lee,
G. Lynch,
H. Koch,
T. Schroeder,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
R. Y. So,
A. Khan,
V. E. Blinov,
A. R. Buzykaev,
V. P. Druzhinin,
V. B. Golubev,
E. A. Kravchenko
, et al. (312 additional authors not shown)
Abstract:
We describe searches for B meson decays to the charmless vector-vector final states omega omega and omega phi with 471 x 10^6 B Bbar pairs produced in e+ e- annihilation at sqrt(s) = 10.58 GeV using the BABAR detector at the PEP-II collider at the SLAC National Accelerator Laboratory. We measure the branching fraction B(B0 --> omega omega) = (1.2 +- 0.3 +0.3-0.2) x 10^-6, where the first uncertain…
▽ More
We describe searches for B meson decays to the charmless vector-vector final states omega omega and omega phi with 471 x 10^6 B Bbar pairs produced in e+ e- annihilation at sqrt(s) = 10.58 GeV using the BABAR detector at the PEP-II collider at the SLAC National Accelerator Laboratory. We measure the branching fraction B(B0 --> omega omega) = (1.2 +- 0.3 +0.3-0.2) x 10^-6, where the first uncertainty is statistical and the second is systematic, corresponding to a significance of 4.4 standard deviations. We also determine the upper limit B(B0 --> omega phi) < 0.7 x 10^-6 at 90% confidence level. These measurements provide the first evidence for the decay B0 --> omega omega, and an improvement of the upper limit for the decay B0 --> omega phi.
△ Less
Submitted 6 March, 2014; v1 submitted 29 November, 2013;
originally announced December 2013.
-
Study of the decay $\bar{B}^{0}\rightarrowΛ_{c}^{+}\bar{p}π^{+}π^{-}$ and its intermediate states
Authors:
The Babar Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
E. Grauges,
A. Palano,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
R. Y. So,
A. Khan,
V. E. Blinov,
A. R. Buzykaev,
V. P. Druzhinin,
V. B. Golubev,
E. A. Kravchenko
, et al. (330 additional authors not shown)
Abstract:
We study the decay $\bar{B}^{0}\rightarrowΛ_{c}^{+}\bar{p}π^{+}π^{-}$, reconstructing the Λ_{c}^{+} baryon in the $p K^{-}π^{+}$ mode, using a data sample of $467\times 10^{6}$ $B\bar{B}$ pairs collected with the BaBar detector at the PEP-2 storage rings at SLAC. We measure branching fractions for decays with intermediate $Σ_{c}$ baryons to be…
▽ More
We study the decay $\bar{B}^{0}\rightarrowΛ_{c}^{+}\bar{p}π^{+}π^{-}$, reconstructing the Λ_{c}^{+} baryon in the $p K^{-}π^{+}$ mode, using a data sample of $467\times 10^{6}$ $B\bar{B}$ pairs collected with the BaBar detector at the PEP-2 storage rings at SLAC. We measure branching fractions for decays with intermediate $Σ_{c}$ baryons to be ${\cal B}[\bar{B}^{0}\rightarrowΣ_{c}(2455)^{++}\bar{p}π^{-}]=(21.3 \pm 1.0 \pm 1.0 \pm 5.5) \times 10^{-5}$, ${\cal B}[\bar{B}^{0}\rightarrowΣ_{c}(2520)^{++}\bar{p}π^{-}]=(11.5\pm 1.0 \pm 0.5 \pm 3.0)\times 10^{-5}$, ${\cal B}[\bar{B}^{0}\rightarrowΣ_{c}(2455)^{0}\bar{p}π^{+}]=(9.1 \pm 0.7 \pm 0.4 \pm 2.4)\times10^{-5}$, and ${\cal B}[\bar{B}^{0}\rightarrowΣ_{c}(2520)^{0}\bar{p}π^{+}]= (2.2 \pm 0.7 \pm 0.1\pm 0.6) \times 10^{-5}$, where the uncertainties are statistical, systematic, and due to the uncertainty on the $Λ_{c}^{+}\rightarrow\proton\Kmπ^{+}$ branching fraction, respectively. For decays without $Σ_{c}(2455)$ or $Σ_{c}(2520)$ resonances, we measure ${\cal B}[\bar{B}^{0}\rightarrowΛ_{c}^{+}\bar{p}π^{+}π^{-}]_{\mathrm{non-Σ_{c}}}=(79 \pm 4 \pm 4 \pm 20)\times10^{-5}$. The total branching fraction is determined to be ${\cal B}[\bar{B}^{0}\rightarrowΛ_{c}^{+}\bar{p}π^{+}π^{-}]_{\mathrm{total}}=(123 \pm 5 \pm 7 \pm 32)\times10^{-5}$. We examine multibody mass combinations in the resonant three-particle $Σ_{c}\bar{p}π$ final states and in the four-particle $Λ_{c}^{+}\bar{p}π^{+}π^{-}$ final state, and observe different characteristics for the $\bar{p}π$ combination in neutral versus doubly-charged $Σ_{c}$ decays.
△ Less
Submitted 28 March, 2013; v1 submitted 1 February, 2013;
originally announced February 2013.
-
Search for direct CP-violation in singly-Cabibbo suppressed D+- --> K+ K- pi+- decays
Authors:
BaBar Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
A. Palano,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
R. Y. So,
A. Khan,
V. E. Blinov,
A. R. Buzykaev,
V. P. Druzhinin,
V. B. Golubev
, et al. (338 additional authors not shown)
Abstract:
We report on a search for direct CP asymmetry in the singly Cabibbo-suppressed decay D+- --> K+ K- pi+- using a data sample of 476 fb-1 accumulated with the BaBar detector running at and just below the Y(4S) resonance. The CP-violating decay rate asymmetry A_CP is determined to be (0.35 +- 0.30 +- 0.15)%. Model-dependent and model-independent Dalitz plot analysis techniques are used to search for…
▽ More
We report on a search for direct CP asymmetry in the singly Cabibbo-suppressed decay D+- --> K+ K- pi+- using a data sample of 476 fb-1 accumulated with the BaBar detector running at and just below the Y(4S) resonance. The CP-violating decay rate asymmetry A_CP is determined to be (0.35 +- 0.30 +- 0.15)%. Model-dependent and model-independent Dalitz plot analysis techniques are used to search for CP-violating asymmetries in the various intermediate states.
△ Less
Submitted 21 February, 2013; v1 submitted 8 December, 2012;
originally announced December 2012.
-
Branching fraction and form-factor shape measurements of exclusive charmless semileptonic B decays, and determination of |V_{ub}|
Authors:
BABAR Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
A. Palano,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
R. Y. So,
A. Khan,
V. E. Blinov,
A. R. Buzykaev,
V. P. Druzhinin,
V. B. Golubev
, et al. (340 additional authors not shown)
Abstract:
We report the results of a study of the exclusive charmless semileptonic decays, B^0 --> pi^- l^+ nu, B^+ --> pi^0 l^+ nu, B^+ --> omega l^+ nu, B^+ --> eta l^+ nu and B^+ --> eta^' l^+ nu, (l = e or mu) undertaken with approximately 462x10^6 B\bar{B} pairs collected at the Upsilon(4S) resonance with the BABAR detector. The analysis uses events in which the signal B decays are reconstructed with a…
▽ More
We report the results of a study of the exclusive charmless semileptonic decays, B^0 --> pi^- l^+ nu, B^+ --> pi^0 l^+ nu, B^+ --> omega l^+ nu, B^+ --> eta l^+ nu and B^+ --> eta^' l^+ nu, (l = e or mu) undertaken with approximately 462x10^6 B\bar{B} pairs collected at the Upsilon(4S) resonance with the BABAR detector. The analysis uses events in which the signal B decays are reconstructed with a loose neutrino reconstruction technique. We obtain partial branching fractions in several bins of q^2, the square of the momentum transferred to the lepton-neutrino pair, for B^0 --> pi^- l^+ nu, B^+ --> pi^0 l^+ nu, B^+ --> omega l^+ nu and B^+ --> eta l^+ nu. From these distributions, we extract the form-factor shapes f_+(q^2) and the total branching fractions BF(B^0 --> pi^- l^+ nu) = (1.45 +/- 0.04_{stat} +/- 0.06_{syst})x10^-4 (combined pi^- and pi^0 decay channels assuming isospin symmetry), BF(B^+ --> omega l^+ nu) = (1.19 +/- 0.16_{stat} +/- 0.09_{syst})x10^-4 and BF(B^+ --> eta l^+ nu) = (0.38 +/- 0.05_{stat} +/- 0.05_{syst})x10^-4. We also measure BF(B^+ --> eta^' l^+ nu) = (0.24 +/- 0.08_{stat} +/- 0.03_{syst})x10^-4. We obtain values for the magnitude of the CKM matrix element V_{ub} by direct comparison with three different QCD calculations in restricted q^2 ranges of B --> pi l^+ nu decays. From a simultaneous fit to the experimental data over the full q^2 range and the FNAL/MILC lattice QCD predictions, we obtain |V_{ub}| = (3.25 +/- 0.31)x10^-3, where the error is the combined experimental and theoretical uncertainty.
△ Less
Submitted 6 November, 2012; v1 submitted 6 August, 2012;
originally announced August 2012.
-
Observation of Time Reversal Violation in the B0 Meson System
Authors:
The BABAR Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
A. Palanoab,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
R. Y. So,
A. Khan,
V. E. Blinov,
A. R. Buzykaev,
V. P. Druzhinin,
V. B. Golubev
, et al. (343 additional authors not shown)
Abstract:
Although CP violation in the B meson system has been well established by the B factories, there has been no direct observation of time reversal violation. The decays of entangled neutral B mesons into definite flavor states ($B^0$ or $\bar{B}^0$), and $J/ψK_S^0$ or $c\bar{c} K_S^0$ final states (referred to as $B_+$ or $B_-$), allow comparisons between the probabilities of four pairs of T-conjugat…
▽ More
Although CP violation in the B meson system has been well established by the B factories, there has been no direct observation of time reversal violation. The decays of entangled neutral B mesons into definite flavor states ($B^0$ or $\bar{B}^0$), and $J/ψK_S^0$ or $c\bar{c} K_S^0$ final states (referred to as $B_+$ or $B_-$), allow comparisons between the probabilities of four pairs of T-conjugated transitions, for example, $\bar{B}^0 \rightarrow B_-$ and $B_- \rightarrow \bar{B}^0$, as a function of the time difference between the two B decays. Using 468 million $B\bar{B}$ pairs produced in $Υ(4S)$ decays collected by the BABAR detector at SLAC, we measure T-violating parameters in the time evolution of neutral B mesons, yielding $ΔS_T^+ = -1.37 \pm 0.14 (stat.) \pm 0.06 (syst.)$ and $ΔS_T^- = 1.17 \pm 0.18 (stat.) \pm 0.11 (syst.)$. These nonzero results represent the first direct observation of T violation through the exchange of initial and final states in transitions that can only be connected by a T-symmetry transformation.
△ Less
Submitted 2 January, 2013; v1 submitted 24 July, 2012;
originally announced July 2012.
-
Initial-State Radiation Measurement of the e+e- -> pi+pi-pi+pi- Cross Section
Authors:
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
M. Martinelli,
D. A. Milanes,
A. Palano,
M. Pappagallo,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
A. Khan,
V. E. Blinov,
A. R. Buzykaev,
V. P. Druzhinin
, et al. (362 additional authors not shown)
Abstract:
We study the process e+e- -> pi+pi-pi+pi-gamma, with a photon emitted from the initial-state electron or positron, using 454.3 fb^-1 of data collected with the BABAR detector at SLAC, corresponding to approximately 260,000 signal events. We use these data to extract the non-radiative sigma(e+e- ->pi+pi-pi+pi-) cross section in the energy range from 0.6 to 4.5 Gev. The total uncertainty of the cros…
▽ More
We study the process e+e- -> pi+pi-pi+pi-gamma, with a photon emitted from the initial-state electron or positron, using 454.3 fb^-1 of data collected with the BABAR detector at SLAC, corresponding to approximately 260,000 signal events. We use these data to extract the non-radiative sigma(e+e- ->pi+pi-pi+pi-) cross section in the energy range from 0.6 to 4.5 Gev. The total uncertainty of the cross section measurement in the peak region is less than 3%, higher in precision than the corresponding results obtained from energy scan data.
△ Less
Submitted 27 August, 2012; v1 submitted 26 January, 2012;
originally announced January 2012.
-
Metastable Staus: Reconstructing Non-Prompt Tracks at the ILC with the SiD Detector
Authors:
Christopher Betancourt,
F. Alexander Bogert,
Bruce A. Schumm
Abstract:
We have explored the reconstruction of kinks from the decay of metastable staus into a gravitino and a stau lepton in the radial region between the outer layer of the vertex detector and the second central tracking layer. After applying a cut on track multiplicity, we find a high efficiency for such events, with minimal background from Standard Model processes.
We have explored the reconstruction of kinks from the decay of metastable staus into a gravitino and a stau lepton in the radial region between the outer layer of the vertex detector and the second central tracking layer. After applying a cut on track multiplicity, we find a high efficiency for such events, with minimal background from Standard Model processes.
△ Less
Submitted 20 December, 2011;
originally announced December 2011.
-
Generic Microstrip R&D Topics at SCIPP: Longitudinal Charge Division and Length Limitations for Long Strips
Authors:
Jerome K. Carman,
Vitaliy Fadeyev,
Khilesh Mistry,
Bruce A. Schumm,
Edwin Spencer,
Aaron Taylor,
Max Wilder
Abstract:
We discuss results on the use of charge division to estimate the longitudinal position of charge deposition in silicon microstrip sensors, and on the intrinsic noise limitation of microstrip sensors in the limit of long, narrow strips. We find a resolution of \pm6% of the length of the sensor for a 10cm-long sensor. We also find that network effects significantly reduce sensor readout noise relati…
▽ More
We discuss results on the use of charge division to estimate the longitudinal position of charge deposition in silicon microstrip sensors, and on the intrinsic noise limitation of microstrip sensors in the limit of long, narrow strips. We find a resolution of \pm6% of the length of the sensor for a 10cm-long sensor. We also find that network effects significantly reduce sensor readout noise relative to naive expectations that arise from treating the detector resistance and capacitance as single discrete electronic components.
△ Less
Submitted 20 December, 2011;
originally announced December 2011.
-
Development of Readout Interconnections for the Si-W Calorimeter of SiD
Authors:
M. Woods,
R. G. Fields,
B. Holbrook,
R. L. Lander,
A. Moskaleva,
C. Neher,
J. Pasner,
M. Tripathi,
J. E. Brau,
R. E. Frey,
D. Strom,
M. Breidenbach,
D. Freytag,
G. Haller,
R. Herbst,
T. Nelson,
S. Schier,
B. Schumm
Abstract:
The SiD collaboration is develo** a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for the interconnections, especially for attaching a silicon detector wafer to a flex cable readout bus. We review the interconnect technologies involved, including o…
▽ More
The SiD collaboration is develo** a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for the interconnections, especially for attaching a silicon detector wafer to a flex cable readout bus. We review the interconnect technologies involved, including oxidation removal processes, pad surface preparation, solder ball selection and placement, and bond quality assurance. Our results show that solder ball bonding is a promising technique for the Si-W ECAL, and unresolved issues are being addressed.
△ Less
Submitted 21 November, 2011; v1 submitted 31 October, 2011;
originally announced October 2011.
-
A Measurement of the Semileptonic Branching Fraction of the B_s Meson
Authors:
The BaBar Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
M. Martinelli,
D. A. Milanes,
A. Palano,
M. Pappagallo,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
A. Khan,
V. E. Blinov,
A. R. Buzykaev
, et al. (362 additional authors not shown)
Abstract:
We report a measurement of the inclusive semileptonic branching fraction of the B_s meson using data collected with the BaBar detector in the center-of-mass (CM) energy region above the Upsilon(4S) resonance. We use the inclusive yield of phi mesons and the phi yield in association with a high-momentum lepton to perform a simultaneous measurement of the semileptonic branching fraction and the pr…
▽ More
We report a measurement of the inclusive semileptonic branching fraction of the B_s meson using data collected with the BaBar detector in the center-of-mass (CM) energy region above the Upsilon(4S) resonance. We use the inclusive yield of phi mesons and the phi yield in association with a high-momentum lepton to perform a simultaneous measurement of the semileptonic branching fraction and the production rate of B_s mesons relative to all B mesons as a function of CM energy. The inclusive semileptonic branching fraction of the B_s meson is determined to be B(B_s to l nu X)=9.5 (+2.5/-2.0)(stat)(+1.1/-1.9)(syst)%, where l indicates the average of e and mu.
△ Less
Submitted 10 January, 2012; v1 submitted 25 October, 2011;
originally announced October 2011.
-
Search for hadronic decays of a light Higgs boson in the radiative decay Upsilon --> gamma A0
Authors:
The BABAR Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
M. Martinelli,
D. A. Milanes,
A. Palano,
M. Pappagallo,
G. Eigen,
B. Stugu,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
R. Y. So,
A. Khan,
V. E. Blinov
, et al. (364 additional authors not shown)
Abstract:
We search for hadronic decays of a light Higgs boson (A0) produced in radiative decays of an Upsilon(2S) or Upsilon(3S) meson, Upsilon --> gamma A0. The data have been recorded by the BABAR experiment at the Upsilon(3S) and Upsilon(2S) center of mass energies, and include (121.3 \pm 1.2) x 10^6 Upsilon(3S) and (98.3 \pm 0.9) x 10^6 Upsilon(2S) mesons. No significant signal is observed. We set 90%…
▽ More
We search for hadronic decays of a light Higgs boson (A0) produced in radiative decays of an Upsilon(2S) or Upsilon(3S) meson, Upsilon --> gamma A0. The data have been recorded by the BABAR experiment at the Upsilon(3S) and Upsilon(2S) center of mass energies, and include (121.3 \pm 1.2) x 10^6 Upsilon(3S) and (98.3 \pm 0.9) x 10^6 Upsilon(2S) mesons. No significant signal is observed. We set 90% confidence level upper limits on the product branching fractions B(Upsilon(nS)-->gamma A0) x B(A0-->hadrons) (n=2 or 3) that range from 1 x 10^{-6} for an A0 mass of 0.3 GeV/c^2 to 8 x 10^{-5} at 7 GeV/c^2.
△ Less
Submitted 17 August, 2011;
originally announced August 2011.
-
Observation of the baryonic B decay B0bar --> Lambda_c^+ anti-Lambda K-
Authors:
The BABAR Collaboration,
J. P. Lees,
V. Poireau,
V. Tisserand,
J. Garra Tico,
E. Grauges,
M. Martinelli,
D. A. Milanes,
A. Palano,
M. Pappagallo,
G. Eigen,
B. Stugu,
L. Sun,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
A. Khan,
V. E. Blinov
, et al. (363 additional authors not shown)
Abstract:
We report the observation of the baryonic B decay B0bar --> Lambda_c^+ anti-Lambda K- with a significance larger than 7 standard deviations based on 471x10^6$ BBbar pairs collected with the BABAR detector at the PEP-II storage ring at SLAC. We measure the branching fraction for the decay B0bar --> Lambda_c^+ anti-Lambda K- to be (3.8 \pm 0.8_{stat} \pm 0.2_{sys} \pm 1.0_{Lambda_c^+})x10^{-5}. The…
▽ More
We report the observation of the baryonic B decay B0bar --> Lambda_c^+ anti-Lambda K- with a significance larger than 7 standard deviations based on 471x10^6$ BBbar pairs collected with the BABAR detector at the PEP-II storage ring at SLAC. We measure the branching fraction for the decay B0bar --> Lambda_c^+ anti-Lambda K- to be (3.8 \pm 0.8_{stat} \pm 0.2_{sys} \pm 1.0_{Lambda_c^+})x10^{-5}. The uncertainties are statistical, systematic, and due to the uncertainty in the Lambda_c^+ branching fraction. We find that the Lambda_c^+ K^- invariant mass distribution shows an enhancement above 3.5 GeV/c^2.
△ Less
Submitted 16 August, 2011;
originally announced August 2011.
-
Study of radiative bottomonium transitions using converted photons
Authors:
The BABAR Collaboration,
J. P. Lees,
V. Poireau,
E. Prencipe,
V. Tisserand,
J. GarraTico,
E. Grauges,
M. Martinelli,
D. A. Milanes,
A. Palano,
M. Pappagallo,
G. Eigen,
B. Stugu,
L. Sun,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna,
A. Khan
, et al. (367 additional authors not shown)
Abstract:
We use 111+/-1 million Upsilon(3S) and 89+/-1 million Upsilon(2S) events recorded by the BaBar detector at the PEP-II B-factory at SLAC to perform a study of radiative transitions between bottomonium states using photons that have been converted to e+e- pairs by the detector material. We observe Upsilon(3S) -> gamma chi_b0,2(1P) decay, make precise measurements of the branching fractions for chi_b…
▽ More
We use 111+/-1 million Upsilon(3S) and 89+/-1 million Upsilon(2S) events recorded by the BaBar detector at the PEP-II B-factory at SLAC to perform a study of radiative transitions between bottomonium states using photons that have been converted to e+e- pairs by the detector material. We observe Upsilon(3S) -> gamma chi_b0,2(1P) decay, make precise measurements of the branching fractions for chi_b1,2(1P,2P) -> gamma Upsilon(1S) and chi_b1,2(2P) -> gamma Upsilon(2S) decays, and search for radiative decay to the eta_b(1S) and eta_b(2S) states.
△ Less
Submitted 21 December, 2011; v1 submitted 27 April, 2011;
originally announced April 2011.
-
Evidence for the h_b(1P) meson in the decay Upsilon(3S) --> pi0 h_b(1P)
Authors:
The BABAR Collaboration,
J. P. Lees,
V. Poireau,
E. Prencipe,
V. Tisserand,
J. Garra Tico,
E. Grauges,
M. Martinelli,
D. A. Milanes,
A. Palano,
M. Pappagallo,
G. Eigen,
B. Stugu,
L. Sun,
D. N. Brown,
L. T. Kerth,
Yu. G. Kolomensky,
G. Lynch,
I. L. Osipenkov,
H. Koch,
T. Schroeder,
D. J. Asgeirsson,
C. Hearty,
T. S. Mattison,
J. A. McKenna
, et al. (386 additional authors not shown)
Abstract:
Using a sample of 122 million Upsilon(3S) events recorded with the BaBar detector at the PEP-II asymmetric-energy e+e- collider at SLAC, we search for the $h_b(1P)$ spin-singlet partner of the P-wave chi_{bJ}(1P) states in the sequential decay Upsilon(3S) --> pi0 h_b(1P), h_b(1P) --> gamma eta_b(1S). We observe an excess of events above background in the distribution of the recoil mass against the…
▽ More
Using a sample of 122 million Upsilon(3S) events recorded with the BaBar detector at the PEP-II asymmetric-energy e+e- collider at SLAC, we search for the $h_b(1P)$ spin-singlet partner of the P-wave chi_{bJ}(1P) states in the sequential decay Upsilon(3S) --> pi0 h_b(1P), h_b(1P) --> gamma eta_b(1S). We observe an excess of events above background in the distribution of the recoil mass against the pi0 at mass 9902 +/- 4(stat.) +/- 2(syst.) MeV/c^2. The width of the observed signal is consistent with experimental resolution, and its significance is 3.1sigma, including systematic uncertainties. We obtain the value (4.3 +/- 1.1(stat.) +/- 0.9(syst.)) x 10^{-4} for the product branching fraction BF(Upsilon(3S)-->pi0 h_b) x BF(h_b-->gamma eta_b).
△ Less
Submitted 17 October, 2011; v1 submitted 22 February, 2011;
originally announced February 2011.
-
Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.
-
Developments in Readout for Silicon Microstrip Sensors at a Linear Collider Detector
Authors:
Jerome Carman,
Kelsey Collier,
Sean Crosby,
Vitaliy Fadeyev,
Bruce A. Schumm,
Ned Spencer
Abstract:
We report recent results on the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and on sources of electronic readout noise for long, thin strips. These results hold promise for the design of Linear Collider charged particle tracking system composed of silicon microstrip sensors.
We report recent results on the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and on sources of electronic readout noise for long, thin strips. These results hold promise for the design of Linear Collider charged particle tracking system composed of silicon microstrip sensors.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
Flavor Physics in the Quark Sector
Authors:
M. Antonelli,
D. M. Asner,
D. Bauer,
T. Becher,
M. Beneke,
A. J. Bevan,
M. Blanke,
C. Bloise,
M. Bona,
A. Bondar,
C. Bozzi,
J. Brod,
A. J. Buras,
N. Cabibbo,
A. Carbone,
G. Cavoto,
V. Cirigliano,
M. Ciuchini,
J. P. Coleman,
D. P. Cronin-Hennessy,
J. P. Dalseno,
C. H. Davies,
F. DiLodovico,
J. Dingfelder,
Z. Dolezal
, et al. (115 additional authors not shown)
Abstract:
One of the major challenges of particle physics has been to gain an in-depth understanding of the role of quark flavor and measurements and theoretical interpretations of their results have advanced tremendously: apart from masses and quantum numbers of flavor particles, there now exist detailed measurements of the characteristics of their interactions allowing stringent tests of Standard Model…
▽ More
One of the major challenges of particle physics has been to gain an in-depth understanding of the role of quark flavor and measurements and theoretical interpretations of their results have advanced tremendously: apart from masses and quantum numbers of flavor particles, there now exist detailed measurements of the characteristics of their interactions allowing stringent tests of Standard Model predictions. Among the most interesting phenomena of flavor physics is the violation of the CP symmetry that has been subtle and difficult to explore. Till early 1990s observations of CP violation were confined to neutral $K$ mesons, but since then a large number of CP-violating processes have been studied in detail in neutral $B$ mesons. In parallel, measurements of the couplings of the heavy quarks and the dynamics for their decays in large samples of $K, D$, and $B$ mesons have been greatly improved in accuracy and the results are being used as probes in the search for deviations from the Standard Model. In the near future, there will be a transition from the current to a new generation of experiments, thus a review of the status of quark flavor physics is timely. This report summarizes the results of the current generation of experiments that is about to be completed and it confronts these results with the theoretical understanding of the field.
△ Less
Submitted 19 February, 2010; v1 submitted 29 July, 2009;
originally announced July 2009.
-
ILC Instrumentation R&D at SCIPP
Authors:
J. Carman,
S. Crosby,
V. Fadeyev,
R. Partridge,
B. A. Schumm,
N. Spencer,
M. Wilder
Abstract:
The Santa Cruz Institute for Particle Physics (SCIPP) continues to be engaged in research and development towards an ILC detector. The latest efforts at SCIPP are described, including those associated with the LSTFE front-end readout ASIC, the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and the contribution of strip resistance to readout noise.
The Santa Cruz Institute for Particle Physics (SCIPP) continues to be engaged in research and development towards an ILC detector. The latest efforts at SCIPP are described, including those associated with the LSTFE front-end readout ASIC, the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and the contribution of strip resistance to readout noise.
△ Less
Submitted 16 January, 2009;
originally announced January 2009.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.