-
New Algorithms for $M$-Estimation of Multivariate Scatter and Location
Authors:
Lutz Duembgen,
Klaus Nordhausen,
Heike Schuhmacher
Abstract:
We present new algorithms for $M$-estimators of multivariate scatter and location and for symmetrized $M$-estimators of multivariate scatter. The new algorithms are considerably faster than currently used fixed-point and related algorithms. The main idea is to utilize a second order Taylor expansion of the target functional and to devise a partial Newton-Raphson procedure. In connection with symme…
▽ More
We present new algorithms for $M$-estimators of multivariate scatter and location and for symmetrized $M$-estimators of multivariate scatter. The new algorithms are considerably faster than currently used fixed-point and related algorithms. The main idea is to utilize a second order Taylor expansion of the target functional and to devise a partial Newton-Raphson procedure. In connection with symmetrized $M$-estimators we work with incomplete $U$-statistics to accelerate our procedures initially.
△ Less
Submitted 3 December, 2015; v1 submitted 23 December, 2013;
originally announced December 2013.
-
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Authors:
The XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori
, et al. (58 additional authors not shown)
Abstract:
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A ve…
▽ More
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
△ Less
Submitted 18 July, 2013; v1 submitted 4 April, 2013;
originally announced April 2013.
-
Characterization of Monoenergetic Neutron Reference Fields with a High Resolution Diamond Detector
Authors:
A. Zimbal,
L. Giacomelli,
R. Nolte,
H. Schuhmacher
Abstract:
A novel radiation detector based on an artificial single crystal diamond was used to characterize in detail the energy distribution of neutron reference fields at the Physikalisch-Technische Bundesanstalt (PTB) and their contamination with charged particles. The monoenergetic reference fields at PTB in the neutron energy range from 1.5 MeV up to 19 MeV are generated by proton and deuteron beams…
▽ More
A novel radiation detector based on an artificial single crystal diamond was used to characterize in detail the energy distribution of neutron reference fields at the Physikalisch-Technische Bundesanstalt (PTB) and their contamination with charged particles. The monoenergetic reference fields at PTB in the neutron energy range from 1.5 MeV up to 19 MeV are generated by proton and deuteron beams im**ing on solid and gas targets of tritium and deuterium. The energy of the incoming particles and the variation of the angle under which the measurement is performed produce monoenergetic reference fields with different mean energies and line shapes.
In this paper we present high resolution neutron spectrometry measurements of different monoenergetic reference fields. The results are compared with calculated spectra taking into account the actual target parameters. Line structures in the order of 80 keV for a neutron energy of 9 MeV were resolved. The shift of the mean energy and the increasing of the width of the neutron peak with increasing pressure in the gas target in the order of 30 keV were measured.
Another result is the determination of the contamination of the neutron field at 14 MeV with high energy charged particles (protons) from side reactions inside the T-target.
The experiments have shown that this detector is an easy to operate compact neutron spectrometer with extremely good energy resolution and that detailed structures in the line shapes of monoenergetic neutron fields can be resolved without using time of flight techniques.
△ Less
Submitted 26 November, 2009;
originally announced November 2009.
-
Development and application of an optical TPC for charged particle track structure imaging in microdosimetry
Authors:
U. Titt,
V. Dangendorf,
B. Grosswendt,
H. Schuhmacher
Abstract:
An imaging system for measuring the track structure of charged particles in a low-pressure gas is presented. We describe the experimental method and compare experimental results with first results of a simulation of the chamber response.
An imaging system for measuring the track structure of charged particles in a low-pressure gas is presented. We describe the experimental method and compare experimental results with first results of a simulation of the chamber response.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Imaging of microscopic features of charged-particle tracks in a low-pressure gas
Authors:
V. Dangendorf,
H. Schuhmacher,
U. Titt,
K. Tittelmeier
Abstract:
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Digital imaging of charged particle track structures with a low-pressure optical time projection chamber
Authors:
U. Titt,
V. Dangendorf,
H. Schuhmacher
Abstract:
We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Images of ionisation tracks of electrons, protons, and heavier ions are presented and analysed.
We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Images of ionisation tracks of electrons, protons, and heavier ions are presented and analysed.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
A time projection chamber with optical readout for charged particle track structure imaging
Authors:
U. Titt,
A. Breskin,
R. Chechik,
V. Dangendorf,
H. Schmidt-Boecking,
H. Schuhmacher
Abstract:
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron aval…
▽ More
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron avalanches with an intensified CCD system. The detector permits to inves-tigate the spatial ionization distributions of particle tracks in gas, of equivalent length and resolution in tissue of 4 mm and 40 nm (RMS), respectively. We explain the relevance of this technique for dosimetry, describe the experimental method and the basic operation parameters. First results of the chamber response to protons and alpha particles are presented.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.