Pulsed RF Knock-Out Extraction: A Potential Enabler for FLASH Hadrontherapy in the Bragg Peak
Authors:
Simon Waid,
Andreas Gsponer,
Elisabeth Renner,
Claus Schmitzer,
Florian Kühteubl,
Clara Becker,
Jürgen Burin,
Philipp Gaggl,
Dale Prokopovich,
Thomas Bergauer
Abstract:
One challenge on the path to delivering FLASH-compatible beams with a synchrotron is facilitating an accurate dose-control for the required ultra-high dose rates. We propose the use of pulsed RFKO extraction instead of continuous beam delivery as a way to control the dose delivered per Voxel. In a first feasibility test dose rates in pulses of up to 600 Gy/s were observed, while the granularity at…
▽ More
One challenge on the path to delivering FLASH-compatible beams with a synchrotron is facilitating an accurate dose-control for the required ultra-high dose rates. We propose the use of pulsed RFKO extraction instead of continuous beam delivery as a way to control the dose delivered per Voxel. In a first feasibility test dose rates in pulses of up to 600 Gy/s were observed, while the granularity at which the dose was delivered is expected to be well below 0.5 Gy.
△ Less
Submitted 19 March, 2024; v1 submitted 15 November, 2023;
originally announced November 2023.
-
Medipix3 proton and carbon ion measurements across full energy ranges and at clinical flux rates in MedAustron IR1
Authors:
Navrit Johan Singh Bal,
Claus Stefan Schmitzer,
Andrea De Franco,
Sascha Enke
Abstract:
The Medipix3, a hybrid pixel detector with a silicon sensor, has been evaluated as a beam instrumentation device with proton and carbon ion measurements in the non-clinical research room (IR1) of MedAustron Ion Therapy Center. Protons energies are varied from 62.4 to 800 MeV with $10^{4}$ to $10^{8}$ protons per second im**ing on the detector surface. For carbon ions, energies are varied from 12…
▽ More
The Medipix3, a hybrid pixel detector with a silicon sensor, has been evaluated as a beam instrumentation device with proton and carbon ion measurements in the non-clinical research room (IR1) of MedAustron Ion Therapy Center. Protons energies are varied from 62.4 to 800 MeV with $10^{4}$ to $10^{8}$ protons per second im**ing on the detector surface. For carbon ions, energies are varied from 120 to 400 MeV/amu with $10^{7}$ to $10^{8}$ carbon ions per second. Measurements include simultaneous high resolution, beam profile and beam intensity with various beam parameters at up to 1000 FPS (frames per second), count rate linearity and an assessment of radiation damage after the measurement day using an x-ray tube to provide a homogeneous radiation measurement. The count rate linearity is found to be linear within the uncertainties (dominated by accelerator related sources due to special setup) for the measurements without degraders. Various frequency components are identified within the beam intensity over time firstly including 49.98 Hz with standard deviation, $σ=0.29$, secondly 30.55 Hz $σ=0.55$ and thirdly 252.51 Hz $σ=0.83$. A direct correlation between the number of zero counting and noisy pixels is observed in the measurements with the highest flux. No conclusive evidence of long term radiation damage was found as a result of these measurements over one day.
△ Less
Submitted 14 October, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Feasibility Study and Perspectives of proton Dielectric Laser Accelerators (p-DLA): from nanosource to accelerator scheme
Authors:
G. Torrisi,
D. Mascali,
A. Bacci,
G. A. P. Cirrone,
G. Cosentino,
G. Della Valle,
N. Gambino,
G. S. Mauro,
G. Petringa,
G. Russo,
C. Schmitzer,
G. Sorbello,
R. A. Wilhelm
Abstract:
In this paper we discuss the possibility to generate and accelerate proton nanobeams in fully dielectric laser-driven accelerators (p-DLAs). High gradient on-chip optical-power dielectric laser accelerators (DLAs) could represent one of the most promising way towards future miniaturized particle accelerator. A primary challenge for DLAs are small beam apertures having a size of the order of the dr…
▽ More
In this paper we discuss the possibility to generate and accelerate proton nanobeams in fully dielectric laser-driven accelerators (p-DLAs). High gradient on-chip optical-power dielectric laser accelerators (DLAs) could represent one of the most promising way towards future miniaturized particle accelerator. A primary challenge for DLAs are small beam apertures having a size of the order of the driving laser wavelength where low charge high-repetition (or also CW) ultralow emittance nanobeams have to be transported. For electrons beams generation and acceleration, intense research activities are ongoing, and several demonstrations have been already obtained by using electrons nanotip (or flat photocathode) sources feeding dielectric microstructures. In this article we aim at the possibility to integrate a nanosource for the generation of a light ion or proton nano-beams suitable for the subsequent acceleration into sub-relativistic (low-beta) p-DLA stages. Such integration includes the idea to use a proton dielectric radiofrequency quadrupole (p-DRFQ) for bridging the gap between the accelerator front-end and the drift-tube and high-beta sections. The paper has been prepared as a white book including state-of-art technologies and new solutions that now put the ambitious frontier of a fully nanostructured proton accelerator into reach. Conceptual studies of p-DLAs here presented could enable table-top proton nano-beams for several applications: proton beam writing, nuclear reaction analysis at sub-micrometer scales, the construction of miniaturized Proton-Boron Nuclear Fusion based Reactors, biological analysis at the micrometer scale, ion beam analysis at the sub-cellular level, mini-beams ion therapy to spare the shallow tissues, proton irradiation of transistors, compact proton linac for neutron generation.
△ Less
Submitted 25 June, 2021;
originally announced June 2021.
-
Commissioning of low particle flux for proton beams at MedAustron
Authors:
Felix Ulrich-Pur,
Laurids Adler,
Thomas Bergauer,
Alexander Burker,
Andrea De Franco,
Greta Guidoboni,
Albert Hirtl,
Christian Irmler,
Stefanie Kaser,
Sebastian Nowak,
Florian Pitters,
Mauro Pivi,
Dale Prokopovich,
Claus Schmitzer,
Alexander Wastl
Abstract:
MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This r…
▽ More
MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.
△ Less
Submitted 27 May, 2021; v1 submitted 11 February, 2021;
originally announced February 2021.
-
Experimental test of quantum contextuality in neutron interferometry
Authors:
H. Bartosik,
J. Klepp,
C. Schmitzer,
S. Sponar,
A. Cabello,
H. Rauch,
Y. Hasegawa
Abstract:
We performed an experimental test of the Kochen-Specker theorem based on an inequality derived from the Peres-Mermin proof, using spin-path (momentum) entanglement in a single neutron system. Following the strategy proposed by Cabello et al. [Phys. Rev. Lett. 100, 130404 (2008)], a Bell-like state was generated and three expectation values were determined. The observed violation 2.291 +/- 0.008…
▽ More
We performed an experimental test of the Kochen-Specker theorem based on an inequality derived from the Peres-Mermin proof, using spin-path (momentum) entanglement in a single neutron system. Following the strategy proposed by Cabello et al. [Phys. Rev. Lett. 100, 130404 (2008)], a Bell-like state was generated and three expectation values were determined. The observed violation 2.291 +/- 0.008 > 1 clearly shows that quantum mechanical predictions cannot be reproduced by noncontextual hidden variables theories.
△ Less
Submitted 23 July, 2009; v1 submitted 29 April, 2009;
originally announced April 2009.