  1. Influence of mechanical deformations on the performance of a coaxial shield for a cryogenic current comparator

    Authors: Nicolas Marsic, Wolfgang F. O. Müller, Volker Tympel, Thomas Stöhlker, Max Stapelfeld, Frank Schmidl, Matthias Schmelz, Vyacheslav Zakosarenko, Ronny Stolz, David Haider, Thomas Sieber, Marcus Schwickert, Herbert De Gersem

    Abstract: This paper studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g. when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this paper also discusses the effect of mech… ▽ More

    Submitted 21 November, 2022; originally announced November 2022.

    Comments: 9 pages, 10 figures

    Journal ref: IEEE Transactions on Applied Superconductivity, vol. 32, no. 9, pp. 1-9, Art no. 2500409, 2022

  2. arXiv:2211.11267  [pdf, other

    physics.acc-ph physics.ins-det

    Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators

    Authors: Nicolas Marsic, Wolfgang F. O. Müller, Herbert De Gersem, Matthias Schmelz, Vyacheslav Zakosarenko, Ronny Stolz, Febin Kurian, Thomas Sieber, Marcus Schwickert

    Abstract: This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric perfor… ▽ More

    Submitted 21 November, 2022; originally announced November 2022.

    Comments: 13 pages, 15 figures

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 922, pp. 134-142, 2019

  3. arXiv:2203.02448  [pdf, other

    cond-mat.mtrl-sci cond-mat.supr-con physics.app-ph

    Reflection-enhanced gain in traveling-wave parametric amplifiers

    Authors: S. Kern, P. Neilinger, E. Iľichev, A. Sultanov, M. Schmelz, S. Linzen, J. Kunert, G. Oelsner, R. Stolz, A. Danilov, S. Mahashabde, A. Jayaraman, V. Antonov, S. Kubatkin, M. Grajcar

    Abstract: The operating principle of traveling-wave parametric amplifiers is typically understood in terms of the standard coupled mode theory, which describes the evolution of forward propagating waves without any reflections, i.e. for perfect impedance matching. However, in practice, superconducting microwave amplifiers are unmatched nonlinear finite-length devices, where the reflecting waves undergo comp… ▽ More

    Submitted 26 May, 2023; v1 submitted 4 March, 2022; originally announced March 2022.

    Comments: 10 pages, 6 figures

    Journal ref: Physical Review B, volume=107.17, 2023, pages: 174520

  4. arXiv:1706.05189  [pdf

    cond-mat.supr-con

    A new family of field-stable and highly sensitive SQUID current sensors based on sub-micrometer cross-type Josephson junctions

    Authors: M. Schmelz, V. Zakosarenko, T. Schönau, S. Anders, J. Kunert, M. Meyer, H. -G. Meyer, R. Stolz

    Abstract: We report on the development of a new family of SQUID current sensors based on sub-micron cross-type Josephson tunnel junctions. Their low total junction capacitance permit high usable voltage swings of more than 100 μV and exceptional low noise of the SQUIDs at 4.2 K. Integrated rf-filter as well as high tolerable background fields during cool-down of up to 9.6 mT enable their highly reliable and… ▽ More

    Submitted 16 June, 2017; originally announced June 2017.

    Comments: 6 pages, 4 figures

    Journal ref: Superconductor Science and Technology, 30, p. 074010 (2017)

  5. Nearly quantum limited nanoSQUIDs based on cross-type Nb/AlOx/Nb junctions

    Authors: M. Schmelz, V. Zakosarenko, T. Schönau, S. Anders, S. Linzen, R. Stolz, H. -G. Meyer

    Abstract: We report on the development of nearly quantum limited SQUIDs with miniature pickup loop dimensions. The implemented high quality and low capacitance cross-type Nb/AlOx/Nb Josephson junctions offer large $I_CR_N$-products and therefore enable an exceptional low noise level of the SQUIDs. Devices with loop dimensions of 1 μm exhibit white flux noise levels as low as $45 nΦ_0/Hz^{1/2}$ corresponding… ▽ More

    Submitted 17 May, 2017; originally announced May 2017.

    Journal ref: Supercond. Sci. Technol. 30 (2017) 014001

  6. arXiv:1705.06152  [pdf

    physics.ins-det cond-mat.supr-con

    Thin-film based ultralow noise SQUID magnetometer

    Authors: M. Schmelz, V. Zakosarenko, A. Chwala, T. Schönau, R. Stolz, S. Anders, S. Linzen, H. -G. Meyer

    Abstract: We report on the development of an ultralow noise thin-film based SQUID magnetometer. A niobium thin-film pickup coil is connected to the input coil of a SQUID current sensor. The low capacitance of the used sub-micrometer cross-type Josephson junctions enable superior noise performance of the device. Application scenarios e.g. in geophysics and ultra-low field magnetic resonance imaging are discu… ▽ More

    Submitted 17 May, 2017; originally announced May 2017.

    Comments: 3 pages, 2 figures

    Journal ref: IEEE Transactions on Applied Superconductivity ( Volume: 26, Issue: 5, Aug. 2016, page 1600804)

  7. Detection of weak microwave fields with an underdamped Josephson junction

    Authors: G. Oelsner, C. K. Andersen, M. Rehák, M. Schmelz, S. Anders, M. Grajcar, U. Hübner, K. Mølmer, E. Il'ichev

    Abstract: We have constructed a microwave detector based on the voltage switching of an underdamped Josephson junction, that is positioned at a current antinode of a λ/4 coplanar waveguide resonator. By measuring the switching current and the transmission through a waveguide capacitively coupled to the resonator at different drive frequencies and temperatures we are able to fully characterize the system and… ▽ More

    Submitted 23 May, 2016; v1 submitted 19 May, 2016; originally announced May 2016.

    Comments: 5 pages, 5 figures

    Journal ref: Phys. Rev. Applied 7, 014012 (2017)

  8. Investigation of all niobium Nano-SQUIDs based on sub-micrometer cross-type Josephson junctions

    Authors: M. Schmelz, Y. Matsui, R. Stolz, V. Zakosarenko, T. Schönau, S. Anders, S. Linzen, H. Itozaki, H. -G. Meyer

    Abstract: We report on the development of highly sensitive SQUIDs featuring sub-micrometer loop dimensions. The integration of high quality and low capacitance SIS Nb/AlOx/Nb cross-type Josephson tunnel junctions results in white flux noise levels as low as 66 n$Φ_0$/Hz$^{ 1/2} $, well below state-of-the-art values of their Nb-based counterparts based on constriction type junctions. Estimation of the spin s… ▽ More

    Submitted 5 January, 2015; originally announced January 2015.

    Comments: 8 pages, 3 figures

    Journal ref: Supercond. Sci. Technol. 28, 015004 (2015)