-
Wide Field Spectral Imaging with Shifted Excitation Raman Difference Spectroscopy Using the Nod and Shuffle Technique
Authors:
Florian Korinth,
Elmar Schmälzlin,
Clara Stiebing,
Tanya Urrutia,
Genoveva Micheva,
Christer Sandin,
André Müller,
Martin Maiwald,
Bernd Sumpf,
Christoph Krafft,
Günther Tränkle,
Martin M. Roth,
Jürgen Popp
Abstract:
Wide field Raman imaging using the integral field spectroscopy approach was used as a fast, one shot imaging method for the simultaneous collection of all spectra composing a Raman image. For the suppression of autofluorescence and background signals such as room light, shifted excitation Raman difference spectroscopy (SERDS) was applied to remove background artifacts in Raman spectra. To reduce a…
▽ More
Wide field Raman imaging using the integral field spectroscopy approach was used as a fast, one shot imaging method for the simultaneous collection of all spectra composing a Raman image. For the suppression of autofluorescence and background signals such as room light, shifted excitation Raman difference spectroscopy (SERDS) was applied to remove background artifacts in Raman spectra. To reduce acquisition times in wide field SERDS imaging, we adapted the nod and shuffle technique from astrophysics and implemented it into a wide field SERDS imaging setup. In our adapted version, the nod corresponds to the change in excitation wavelength, whereas the shuffle corresponds to the shifting of charges up and down on a Charge-Coupled Device (CCD) chip synchronous to the change in excitation wavelength. We coupled this improved wide field SERDS imaging setup to diode lasers with 784.4/785.5 and 457.7/458.9 nm excitation and applied it to samples such as paracetamol and aspirin tablets, polystyrene and polymethyl methacrylate beads, as well as pork meat using multiple accumulations with acquisition times in the range of 50 to 200 ms. The results tackle two main challenges of SERDS imaging: gradual photobleaching changes the autofluorescence background, and multiple readouts of CCD detector prolong the acquisition time.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Nonscanning large-area Raman imaging for ex vivo/in vivo skin cancer discrimination
Authors:
Elmar Schmälzlin,
Benito Moralejo,
Ingo Gersonde,
Johannes Schleusener,
Maxim E. Darvin,
Gisela Thiede,
Martin M. Roth
Abstract:
Imaging Raman spectroscopy can be used to identify cancerous tissue. Traditionally, a step-by-step scanning of the sample is applied to generate a Raman image, which, however, is too slow for routine examination of patients. By transferring the technique of integral field spectroscopy (IFS) from astronomy to Raman imaging, it becomes possible to record entire Raman images quickly within a single e…
▽ More
Imaging Raman spectroscopy can be used to identify cancerous tissue. Traditionally, a step-by-step scanning of the sample is applied to generate a Raman image, which, however, is too slow for routine examination of patients. By transferring the technique of integral field spectroscopy (IFS) from astronomy to Raman imaging, it becomes possible to record entire Raman images quickly within a single exposure, without the need for a tedious scanning procedure. An IFS-based Raman imaging setup is presented, which is capable of measuring skin ex vivo or in vivo. It is demonstrated how Raman images of healthy and cancerous skin biopsies were recorded and analyzed.
△ Less
Submitted 8 October, 2018;
originally announced October 2018.
-
The Potsdam MRS Spectrograph - heritage of MUSE and the impact of cross-innovation in the process of technology transfer
Authors:
Benito Moralejo,
Martin M. Roth,
Philippe Godefroy,
Thomas Fechner,
Svend M. Bauer,
Elmar Schmälzlin,
Andreas Kelz,
Roger Haynes
Abstract:
After having demonstrated that an IFU, attached to a microscope rather than to a telescope, is capable of differentiating complex organic tissue with spatially resolved Raman spectroscopy, we have launched a clinical validation program that utilizes a novel optimized fiber-coupled multi-channel spectrograph whose layout is based on the modular MUSE spectrograph concept. The new design features a t…
▽ More
After having demonstrated that an IFU, attached to a microscope rather than to a telescope, is capable of differentiating complex organic tissue with spatially resolved Raman spectroscopy, we have launched a clinical validation program that utilizes a novel optimized fiber-coupled multi-channel spectrograph whose layout is based on the modular MUSE spectrograph concept. The new design features a telecentric input and has an extended blue performance, but otherwise maintains the properties of high throughput and excellent image quality over an octave of wavelength coverage with modest spectral resolution. We present the opto-mechanical layout and details of its optical performance.
△ Less
Submitted 6 July, 2016; v1 submitted 5 July, 2016;
originally announced July 2016.