Skip to main content

Showing 1–3 of 3 results for author: Schmälzlin, E

.
  1. arXiv:2011.13736  [pdf, other

    physics.ins-det astro-ph.IM physics.app-ph physics.bio-ph

    Wide Field Spectral Imaging with Shifted Excitation Raman Difference Spectroscopy Using the Nod and Shuffle Technique

    Authors: Florian Korinth, Elmar Schmälzlin, Clara Stiebing, Tanya Urrutia, Genoveva Micheva, Christer Sandin, André Müller, Martin Maiwald, Bernd Sumpf, Christoph Krafft, Günther Tränkle, Martin M. Roth, Jürgen Popp

    Abstract: Wide field Raman imaging using the integral field spectroscopy approach was used as a fast, one shot imaging method for the simultaneous collection of all spectra composing a Raman image. For the suppression of autofluorescence and background signals such as room light, shifted excitation Raman difference spectroscopy (SERDS) was applied to remove background artifacts in Raman spectra. To reduce a… ▽ More

    Submitted 27 November, 2020; originally announced November 2020.

    Comments: Accepted and Published by "Sensors" Journal, 19 pages, 8 figures

    Journal ref: Sensors 2020, 20(23), 6723

  2. arXiv:1810.03363  [pdf

    astro-ph.IM physics.med-ph

    Nonscanning large-area Raman imaging for ex vivo/in vivo skin cancer discrimination

    Authors: Elmar Schmälzlin, Benito Moralejo, Ingo Gersonde, Johannes Schleusener, Maxim E. Darvin, Gisela Thiede, Martin M. Roth

    Abstract: Imaging Raman spectroscopy can be used to identify cancerous tissue. Traditionally, a step-by-step scanning of the sample is applied to generate a Raman image, which, however, is too slow for routine examination of patients. By transferring the technique of integral field spectroscopy (IFS) from astronomy to Raman imaging, it becomes possible to record entire Raman images quickly within a single e… ▽ More

    Submitted 8 October, 2018; originally announced October 2018.

  3. The Potsdam MRS Spectrograph - heritage of MUSE and the impact of cross-innovation in the process of technology transfer

    Authors: Benito Moralejo, Martin M. Roth, Philippe Godefroy, Thomas Fechner, Svend M. Bauer, Elmar Schmälzlin, Andreas Kelz, Roger Haynes

    Abstract: After having demonstrated that an IFU, attached to a microscope rather than to a telescope, is capable of differentiating complex organic tissue with spatially resolved Raman spectroscopy, we have launched a clinical validation program that utilizes a novel optimized fiber-coupled multi-channel spectrograph whose layout is based on the modular MUSE spectrograph concept. The new design features a t… ▽ More

    Submitted 6 July, 2016; v1 submitted 5 July, 2016; originally announced July 2016.

    Comments: 13 pages, 13 figures. Submitted in SPIE Astronomical Telescopes + Instrumentation, Paper No. 9912-72