-
The time-variable ultraviolet sky: Active Galactic Nuclei, Stars and White Dwarfs
Authors:
Rolf Buehler,
Julian Schliwinski
Abstract:
Here, we present the 1UVA catalog of time variable ultraviolet (UV) sources. We describe a new analysis pipeline, the VAriable Source Clustering Analysis (VASCA). We apply the pipeline to 10 years of data from the GALaxy Evolution eXplorer (GALEX) satellite. We analyse a sky area of 302 deg$^2$ , resulting in the detection of 4202 time-variable UV sources. We cross correlate these sources with mul…
▽ More
Here, we present the 1UVA catalog of time variable ultraviolet (UV) sources. We describe a new analysis pipeline, the VAriable Source Clustering Analysis (VASCA). We apply the pipeline to 10 years of data from the GALaxy Evolution eXplorer (GALEX) satellite. We analyse a sky area of 302 deg$^2$ , resulting in the detection of 4202 time-variable UV sources. We cross correlate these sources with multi-frequency data from the Gaia satellite and the SIMBAD database, finding an association for 3655 sources. The source sample is dominated by Active Galactic Nuclei ($\approx$73 %) and stars ($\approx$24 %). We look at UV and multi-frequency properties of these sources, focusing on the stellar population. We find UV variability for four White Dwarfs. One of them, WD J004917.14-252556.81, has recently been found to be the most massive pulsating White Dwarf. Its Spectral Energy Distribution shows no sign of a stellar companion. The observed flux variability is unexpected and difficult to explain.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
The scientific payload of the Ultraviolet Transient Astronomy Satellite (ULTRASAT)
Authors:
Sagi Ben-Ami,
Yossi Shvartzvald,
Eli Waxman,
Udi Netzer,
Yoram Yaniv,
Viktor M. Algranatti,
Avishay Gal-Yam,
Ofer Lapid,
Eran Ofek,
Jeremy Topaz,
Iair Arcavi,
Arooj Asif,
Shlomi Azaria,
Eran Bahalul,
Merlin F. Barschke,
Benjamin Bastian-Querner,
David Berge,
Vlad D. Berlea,
Rolf Buhler,
Louise Dittmar,
Anatoly Gelman,
Gianluca Giavitto,
Or Guttman,
Juan M. Haces Crespo,
Daniel Heilbrunn
, et al. (23 additional authors not shown)
Abstract:
The Ultraviolet Transient Astronomy Satellite (ULTRASAT) is a space-borne near UV telescope with an unprecedented large field of view (200 sq. deg.). The mission, led by the Weizmann Institute of Science and the Israel Space Agency in collaboration with DESY (Helmholtz association, Germany) and NASA (USA), is fully funded and expected to be launched to a geostationary transfer orbit in Q2/3 of 202…
▽ More
The Ultraviolet Transient Astronomy Satellite (ULTRASAT) is a space-borne near UV telescope with an unprecedented large field of view (200 sq. deg.). The mission, led by the Weizmann Institute of Science and the Israel Space Agency in collaboration with DESY (Helmholtz association, Germany) and NASA (USA), is fully funded and expected to be launched to a geostationary transfer orbit in Q2/3 of 2025. With a grasp 300 times larger than GALEX, the most sensitive UV satellite to date, ULTRASAT will revolutionize our understanding of the hot transient universe, as well as of flaring galactic sources. We describe the mission payload, the optical design and the choice of materials allowing us to achieve a point spread function of ~10arcsec across the FoV, and the detector assembly. We detail the mitigation techniques implemented to suppress out-of-band flux and reduce stray light, detector properties including measured quantum efficiency of scout (prototype) detectors, and expected performance (limiting magnitude) for various objects.
△ Less
Submitted 11 March, 2023; v1 submitted 30 July, 2022;
originally announced August 2022.
-
Sensor characterization for the ULTRASAT space telescope
Authors:
Benjamin Bastian-Querner,
Nirmal Kaipachery,
Daniel Küsters,
Julian Schliwinski,
Shay Alfassi,
Arooj Asif,
Merlin F. Barschke,
Sagi Ben-Ami,
David Berge,
Adi Birman,
Rolf Bühler,
Nicola De Simone,
Amos Fenigstein,
Avishay Gal-Yam,
Gianluca Giavitto,
Juan M. Haces Crespo,
Dmitri Ivanov,
Omer Katz,
Marek Kowalski,
Shrinivasrao R. Kulkarni,
Ofer Lapid,
Tuvia Liran,
Ehud Netzer,
Eran O. Ofek,
Sebastian Philipp
, et al. (9 additional authors not shown)
Abstract:
The Ultraviolet Transient Astronomical Satellite is a scientific space mission carrying an astronomical telescope. The mission is led by the Weizmann Institute of Science in Israel and the Israel Space Agency, while the camera in the focal plane is designed and built by Deutsches Elektronen Synchrotron in Germany. Two key science goals of the mission are the detection of counterparts to gravitatio…
▽ More
The Ultraviolet Transient Astronomical Satellite is a scientific space mission carrying an astronomical telescope. The mission is led by the Weizmann Institute of Science in Israel and the Israel Space Agency, while the camera in the focal plane is designed and built by Deutsches Elektronen Synchrotron in Germany. Two key science goals of the mission are the detection of counterparts to gravitational wave sources and supernovae. The launch to geostationary orbit is planned for 2024. The telescope with a field-of-view of $\approx200$deg$^2$, is optimized to work in the near-ultraviolet band between $220$ and $280$nm. The focal plane array is composed of four $22.4$-megapixel, backside-illuminated CMOS sensors with a total active area of 90x90mm$^2$. Prior to sensor production, smaller test sensors have been tested to support critical design decisions for the final flight sensor. These test sensors share the design of epitaxial layer and anti-reflective coatings (ARC) with the flight sensors. Here, we present a characterization of these test sensors. Dark current and read noise are characterized as a function of the device temperature. A temperature-independent noise level is attributed to on-die infrared emission and the read-out electronics` self-heating. We utilize a high-precision photometric calibration setup to obtain the test sensors` quantum efficiency (QE) relative to PTB/NIST-calibrated transfer standards ($220$-$1100$nm), the quantum yield for $λ< 300$nm, the non-linearity of the system, and the conversion gain. The uncertainties are discussed in the context of the newest results on the setup`s performance parameters. From three ARC options, Tstd, T1 and T2, the latter optimizes out-of-band rejection and peaks in the mid of the ULTRASAT operational waveband (max. QE $\approx80\%$ at $245\mathrm{nm}$). We recommend ARC option T2 for the final ULTRASAT UV sensor.
△ Less
Submitted 5 August, 2021;
originally announced August 2021.
-
Design of the ULTRASAT UV camera
Authors:
Arooj Asif,
Merlin Barschke,
Benjamin Bastian-Querner,
David Berge,
Rolf Bühler,
Nicola De Simone,
Gianluca Giavitto,
Juan M. Haces Crespo,
Nirmal Kaipachery,
Marek Kowalski,
Shrinivasrao R. Kulkarni,
Daniel Küsters,
Sebastian Philipp,
Heike Prokoph,
Julian Schliwinski,
Mikhail Vasilev,
Jason J. Watson,
Steven Worm,
Francesco Zappon,
Shay Alfassi,
Sagi Ben-Ami,
Adi Birman,
Kasey Boggs,
Greg Bredthauer,
Amos Fenigstein
, et al. (12 additional authors not shown)
Abstract:
The Ultraviolet Transient Astronomical Satellite (ULTRASAT) is a scientific UV space telescope that will operate in geostationary orbit. The mission, targeted to launch in 2024, is led by the Weizmann Institute of Science (WIS) in Israel and the Israel Space Agency (ISA). Deutsches Elektronen Synchrotron (DESY) in Germany is tasked with the development of the UV-sensitive camera at the heart of th…
▽ More
The Ultraviolet Transient Astronomical Satellite (ULTRASAT) is a scientific UV space telescope that will operate in geostationary orbit. The mission, targeted to launch in 2024, is led by the Weizmann Institute of Science (WIS) in Israel and the Israel Space Agency (ISA). Deutsches Elektronen Synchrotron (DESY) in Germany is tasked with the development of the UV-sensitive camera at the heart of the telescope. The camera's total sensitive area of ~90mm x 90mm is built up by four back-side illuminated CMOS sensors, which image a field of view of ~200 deg2. Each sensor has 22.4 megapixels. The Schmidt design of the telescope locates the detector inside the optical path, limiting the overall size of the assembly. As a result, the readout electronics is located in a remote unit outside the telescope. The short focal length of the telescope requires an accurate positioning of the sensors within +-50 mu along the optical axis, with a flatness of +-10 mu. While the telescope will be at around 295K during operations, the sensors are required to be cooled to 200K for dark current reduction. At the same time, the ability to heat the sensors to 343K is required for decontamination. In this paper, we present the preliminary design of the UV sensitive ULTRASAT camera.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Sensitivity of the SHiP experiment to dark photons decaying to a pair of charged particles
Authors:
SHiP Collaboration,
C. Ahdida,
A. Akmete,
R. Albanese,
A. Alexandrov,
A. Anokhina,
S. Aoki,
G. Arduini,
E. Atkin,
N. Azorskiy,
J. J. Back,
A. Bagulya,
F. Baaltasar Dos Santos,
A. Baranov,
F. Bardou,
G. J. Barker,
M. Battistin,
J. Bauche,
A. Bay,
V. Bayliss,
G. Bencivenni,
A. Y. Berdnikov,
Y. A. Berdnikov,
M. Bertani,
C. Betancourt
, et al. (309 additional authors not shown)
Abstract:
Dark photons are hypothetical massive vector particles that could mix with ordinary photons. The simplest theoretical model is fully characterised by only two parameters: the mass of the dark photon m$_{γ^{\mathrm{D}}}$ and its mixing parameter with the photon, $\varepsilon$. The sensitivity of the SHiP detector is reviewed for dark photons in the mass range between 0.002 and 10 GeV. Different pro…
▽ More
Dark photons are hypothetical massive vector particles that could mix with ordinary photons. The simplest theoretical model is fully characterised by only two parameters: the mass of the dark photon m$_{γ^{\mathrm{D}}}$ and its mixing parameter with the photon, $\varepsilon$. The sensitivity of the SHiP detector is reviewed for dark photons in the mass range between 0.002 and 10 GeV. Different production mechanisms are simulated, with the dark photons decaying to pairs of visible fermions, including both leptons and quarks. Exclusion contours are presented and compared with those of past experiments. The SHiP detector is expected to have a unique sensitivity for m$_{γ^{\mathrm{D}}}$ ranging between 0.8 and 3.3$^{+0.2}_{-0.5}$ GeV, and $\varepsilon^2$ ranging between $10^{-11}$ and $10^{-17}$.
△ Less
Submitted 1 March, 2021; v1 submitted 10 November, 2020;
originally announced November 2020.
-
SND@LHC
Authors:
SHiP Collaboration,
C. Ahdida,
A. Akmete,
R. Albanese,
A. Alexandrov,
M. Andreini,
A. Anokhina,
S. Aoki,
G. Arduini,
E. Atkin,
N. Azorskiy,
J. J. Back,
A. Bagulya,
F. Baaltasar Dos Santos,
A. Baranov,
F. Bardou,
G. J. Barker,
M. Battistin,
J. Bauche,
A. Bay,
V. Bayliss,
G. Bencivenni,
A. Y. Berdnikov,
Y. A. Berdnikov,
M. Bertani
, et al. (319 additional authors not shown)
Abstract:
We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1)…
▽ More
We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1) and, given the pseudo-rapidity range accessible, the corresponding neutrinos will mostly come from charm decays: the proposed experiment will thus make the first test of the heavy flavour production in a pseudo-rapidity range that is not accessible by the current LHC detectors. In order to efficiently reconstruct neutrino interactions and identify their flavour, the detector will combine in the target region nuclear emulsion technology with scintillating fibre tracking layers and it will adopt a muon identification system based on scintillating bars that will also play the role of a hadronic calorimeter. The time of flight measurement will be achieved thanks to a dedicated timing detector. The detector will be a small-scale prototype of the scattering and neutrino detector (SND) of the SHiP experiment: the operation of this detector will provide an important test of the neutrino reconstruction in a high occupancy environment.
△ Less
Submitted 20 February, 2020;
originally announced February 2020.
-
Calorimeters for the FCC-hh
Authors:
M. Aleksa,
P. Allport,
R. Bosley,
J. Faltova,
J. Gentil,
R. Goncalo,
C. Helsens,
A. Henriques,
A. Karyukhin,
J. Kieseler,
C. Neubüser,
H. F. Pais Da Silva,
T. Price,
J. Schliwinski,
M. Selvaggi,
O. Solovyanov,
A. Zaborowska
Abstract:
The future proton-proton collider (FCC-hh) will deliver collisions at a center of mass energy up to $\sqrt{s}=100$ TeV at an unprecedented instantaneous luminosity of $L=3~10^{35}$ cm$^{-2}$s$^{-1}$, resulting in extremely challenging radiation and luminosity conditions. By delivering an integrated luminosity of few tens of ab$^{-1}$, the FCC-hh will provide an unrivalled discovery potential for n…
▽ More
The future proton-proton collider (FCC-hh) will deliver collisions at a center of mass energy up to $\sqrt{s}=100$ TeV at an unprecedented instantaneous luminosity of $L=3~10^{35}$ cm$^{-2}$s$^{-1}$, resulting in extremely challenging radiation and luminosity conditions. By delivering an integrated luminosity of few tens of ab$^{-1}$, the FCC-hh will provide an unrivalled discovery potential for new physics. Requiring high sensitivity for resonant searches at masses up to tens of TeV imposes strong constraints on the design of the calorimeters. Resonant searches in final states containing jets, taus and electrons require both excellent energy resolution at multi-TeV energies as well as outstanding ability to resolve highly collimated decay products resulting from extreme boosts. In addition, the FCC-hh provides the unique opportunity to precisely measure the Higgs self-coupling in the di-photon and b-jets channel. Excellent photon and jet energy resolution at low energies as well as excellent angular resolution for pion background rejection are required in this challenging environment. This report describes the calorimeter studies for a multi-purpose detector at the FCC-hh. The calorimeter active components consist of Liquid Argon, scintillating plastic tiles and Monolithic Active Pixel Sensors technologies. The technological choices, design considerations and achieved performances in full Geant4 simulations are discussed and presented. The simulation studies are focused on the evaluation of the concepts. Standalone studies under laboratory conditions as well as first tests in realistic FCC-hh environment, including pileup rejection capabilities by making use of fast signals and high granularity, have been performed. These studies have been performed within the context of the preparation of the FCC conceptual design reports (CDRs).
△ Less
Submitted 20 December, 2019;
originally announced December 2019.
-
Proof-of-principle measurements with a liquid-scintillator detector using wavelength-shifting optical modules
Authors:
M. Ehlert,
A. Hollnagel,
I. Korol,
A. Korzenev,
H. Lacker,
P. Mermod,
J. Schliwinski,
L. Shihora,
P. Venkova,
M. Wurm
Abstract:
Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light guides that are viewed either by a photomultiplier tube or by an array of silicon photomultipliers. We report on the efficiency, the time resolution and the detector…
▽ More
Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light guides that are viewed either by a photomultiplier tube or by an array of silicon photomultipliers. We report on the efficiency, the time resolution and the detector response to different particle types and point out potential ways to improve the detector performance.
△ Less
Submitted 16 December, 2018;
originally announced December 2018.