-
Artificial Intelligence-Facilitated Online Adaptive Proton Therapy Using Pencil Beam Scanning Proton Therapy
Authors:
Hongying Feng,
Jie Shan,
Carlos E. Vargas,
Sameer R. Keole,
Jean-Claude M. Rwigema,
Nathan Y. Yu,
Yuzhen Ding,
Lian Zhang,
Steven E. Schild,
William W. Wong,
Sujay A. Vora,
JiaJian Shen,
Wei Liu
Abstract:
We propose an oAPT workflow that incorporates all these functionalities and validate its clinical implementation feasibility with prostate patients. AI-based auto-segmentation tool AccuContourTM (Manteia, Xiamen, China) was seamlessly integrated into oAPT. Initial spot arrangement tool on the vCT for re-optimization was implemented using raytracing. An LET-based biological effect evaluation tool w…
▽ More
We propose an oAPT workflow that incorporates all these functionalities and validate its clinical implementation feasibility with prostate patients. AI-based auto-segmentation tool AccuContourTM (Manteia, Xiamen, China) was seamlessly integrated into oAPT. Initial spot arrangement tool on the vCT for re-optimization was implemented using raytracing. An LET-based biological effect evaluation tool was developed to assess the overlap region of high dose and high LET in selected OARs. Eleven prostate cancer patients were retrospectively selected to verify the efficacy and efficiency of the proposed oAPT workflow. The time cost of each component in the workflow was recorded for analysis. The verification plan showed significant degradation of the CTV coverage and rectum and bladder sparing due to the interfractional anatomical changes. Re-optimization on the vCT resulted in great improvement of the plan quality. No overlap regions of high dose and high LET distributions were observed in bladder or rectum in re-plans. 3D Gamma analyses in PSQA confirmed the accuracy of the re-plan doses before delivery (Gamma passing rate = 99.57%), and after delivery (98.59%). The robustness of the re-plans passed all clinical requirements. The average time for the complete execution of the workflow was 9.12minutes, excluding manual intervention time. The AI-facilitated oAPT workflow was demonstrated to be both efficient and effective by generating a re-plan that significantly improved the plan quality in prostate cancer treated with PBSPT.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
-
Beam mask and sliding window-facilitated deep learning-based accurate and efficient dose prediction for pencil beam scanning proton therapy
Authors:
Lian Zhang,
Jason M. Holmes,
Zhengliang Liu,
Sujay A. Vora,
Terence T. Sio,
Carlos E. Vargas,
Nathan Y. Yu,
Sameer R. Keole,
Steven E. Schild,
Martin Bues,
Sheng Li,
Tianming Liu,
Jiajian Shen,
William W. Wong,
Wei Liu
Abstract:
Purpose: To develop a DL-based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on-line adaptive proton therapy clinical decision and subsequent replanning.
Methods: PBSPT plans of 103 prostate cancer patients and 83 lung cancer patients previously treated at our institution were included in the study, each with CTs, structure sets, and plan doses calculated b…
▽ More
Purpose: To develop a DL-based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on-line adaptive proton therapy clinical decision and subsequent replanning.
Methods: PBSPT plans of 103 prostate cancer patients and 83 lung cancer patients previously treated at our institution were included in the study, each with CTs, structure sets, and plan doses calculated by the in-house developed Monte-Carlo dose engine. For the ablation study, we designed three experiments corresponding to the following three methods: 1) Experiment 1, the conventional region of interest (ROI) method. 2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. 3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D-Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates, and dice coefficients for the structures enclosed by the iso-dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency.
Results: Compared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices. For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method can improve the passing rates in these regions and the sliding window method further improved them. A similar trend was also observed for the dice coefficients. In fact, this trend was especially remarkable for relatively low prescription isodose lines. The dose predictions for all the testing cases were completed within 0.25s.
△ Less
Submitted 29 May, 2023;
originally announced May 2023.
-
Deep-Learning-based Fast and Accurate 3D CT Deformable Image Registration in Lung Cancer
Authors:
Yuzhen Ding,
Hongying Feng,
Yunze Yang,
Jason Holmes,
Zhengliang Liu,
David Liu,
William W. Wong,
Nathan Y. Yu,
Terence T. Sio,
Steven E. Schild,
Baoxin Li,
Wei Liu
Abstract:
Purpose: In some proton therapy facilities, patient alignment relies on two 2D orthogonal kV images, taken at fixed, oblique angles, as no 3D on-the-bed imaging is available. The visibility of the tumor in kV images is limited since the patient's 3D anatomy is projected onto a 2D plane, especially when the tumor is behind high-density structures such as bones. This can lead to large patient setup…
▽ More
Purpose: In some proton therapy facilities, patient alignment relies on two 2D orthogonal kV images, taken at fixed, oblique angles, as no 3D on-the-bed imaging is available. The visibility of the tumor in kV images is limited since the patient's 3D anatomy is projected onto a 2D plane, especially when the tumor is behind high-density structures such as bones. This can lead to large patient setup errors. A solution is to reconstruct the 3D CT image from the kV images obtained at the treatment isocenter in the treatment position.
Methods: An asymmetric autoencoder-like network built with vision-transformer blocks was developed. The data was collected from 1 head and neck patient: 2 orthogonal kV images (1024x1024 voxels), 1 3D CT with padding (512x512x512) acquired from the in-room CT-on-rails before kVs were taken and 2 digitally-reconstructed-radiograph (DRR) images (512x512) based on the CT. We resampled kV images every 8 voxels and DRR and CT every 4 voxels, thus formed a dataset consisting of 262,144 samples, in which the images have a dimension of 128 for each direction. In training, both kV and DRR images were utilized, and the encoder was encouraged to learn the jointed feature map from both kV and DRR images. In testing, only independent kV images were used. The full-size synthetic CT (sCT) was achieved by concatenating the sCTs generated by the model according to their spatial information. The image quality of the synthetic CT (sCT) was evaluated using mean absolute error (MAE) and per-voxel-absolute-CT-number-difference volume histogram (CDVH).
Results: The model achieved a speed of 2.1s and a MAE of <40HU. The CDVH showed that <5% of the voxels had a per-voxel-absolute-CT-number-difference larger than 185 HU.
Conclusion: A patient-specific vision-transformer-based network was developed and shown to be accurate and efficient to reconstruct 3D CT images from kV images.
△ Less
Submitted 21 April, 2023;
originally announced April 2023.