-
A single-photon large-momentum-transfer atom interferometry scheme for Sr or Yb atoms with application to determining the fine-structure constant
Authors:
Jesse S. Schelfhout,
Thomas M. Hird,
Kenneth M. Hughes,
Christopher J. Foot
Abstract:
The leading experimental determinations of the fine-structure constant, $α$, currently rely on atomic photon-recoil measurements from Ramsey-Bordé atom interferometry with large momentum transfer to provide an absolute mass measurement. We propose an experimental scheme for an intermediate-scale differential atom interferometer to measure the photon-recoil of neutral atomic species with a single-p…
▽ More
The leading experimental determinations of the fine-structure constant, $α$, currently rely on atomic photon-recoil measurements from Ramsey-Bordé atom interferometry with large momentum transfer to provide an absolute mass measurement. We propose an experimental scheme for an intermediate-scale differential atom interferometer to measure the photon-recoil of neutral atomic species with a single-photon optical clock transition. We calculate trajectories for our scheme that optimise the recoil phase while nullifying the undesired gravity-gradient phase by considering independently launching two clouds of ultracold atoms with the appropriate initial conditions. For Sr and Yb, we find an atom interferometer of height 3m to be sufficient for an absolute mass measurement precision of $Δm / m \sim 1\times 10^{-11}$ with current technology. Such a precise measurement (the first of its kind for Sr or Yb) would halve the uncertainty in $α$ -- an uncertainty that would no longer be limited by an absolute mass measurement. The removal of this limitation would allow the uncertainty in $α$ to be reduced by a factor of 10 by corresponding improvements in relative mass measurements, thus paving the way for higher-precision tests of the Standard Model of particle physics.
△ Less
Submitted 3 June, 2024; v1 submitted 15 March, 2024;
originally announced March 2024.
-
Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories
Authors:
B. Stray,
O. Ennis,
S. Hedges,
S. Dey,
M. Langlois,
K. Bongs,
S. Lellouch,
M. Holynski,
B. Bostwick,
J. Chen,
Z. Eyler,
V. Gibson,
T. L. Harte,
M. Hsu,
M. Karzazi,
J. Mitchell,
N. Mouelle,
U. Schneider,
Y. Tang,
K. Tkalcec,
Y. Zhi,
K. Clarke,
A. Vick,
K. Bridges,
J. Coleman
, et al. (47 additional authors not shown)
Abstract:
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the…
▽ More
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
MCDHF-CI calculations for Hg and Cd with estimates for unknown clock transition frequencies
Authors:
Jesse S. Schelfhout,
John J. McFerran
Abstract:
By use of the \textsc{grasp2018} package we perform Multiconfiguration Dirac-Hartree-Fock (MCDHF) calculations with configuration interaction (CI) for the $^{1}S_{0}$ and $^{3}P_{0,1}^o$ levels in neutral cadmium and mercury. By supplying the resultant atomic state functions to the \textsc{ris4} program, we evaluate the mass and field shift parameters for the $^{1}S_{0}-\,^{3}P_{0}^o$ (clock) and…
▽ More
By use of the \textsc{grasp2018} package we perform Multiconfiguration Dirac-Hartree-Fock (MCDHF) calculations with configuration interaction (CI) for the $^{1}S_{0}$ and $^{3}P_{0,1}^o$ levels in neutral cadmium and mercury. By supplying the resultant atomic state functions to the \textsc{ris4} program, we evaluate the mass and field shift parameters for the $^{1}S_{0}-\,^{3}P_{0}^o$ (clock) and $^{1}S_{0}-\,^{3}P_{1}^o$ (intercombination) lines. We make revised estimates of the nuclear charge parameters $λ^{A,A'}$ and differences in mean-square charge radii $δ\langle r^2\rangle^{A,A'}$ for both elements and point out a discrepancy with tabulated data for Cd. In constructing a King plot with the Hg lines we examine the second-order hyperfine interaction for the $^{3}P_{0,1}^o$ levels. Isotope shifts for the clock transition have been estimated from which we predict the unknown clock line frequencies in the bosonic Hg isotopes and all the naturally occurring isotopes of Cd.
△ Less
Submitted 20 December, 2021; v1 submitted 11 December, 2021;
originally announced December 2021.
-
Isotope shifts for ${}^1S_0-{}^3P_{0,1}^o$ Yb lines from multi-configuration Dirac-Hartree-Fock calculations
Authors:
Jesse S. Schelfhout,
John J. McFerran
Abstract:
Relativistic multiconfiguration Dirac-Hartree-Fock (MCDHF) calculations with configuration interaction (CI) are carried out for the $^{1}S_{0}$ and $^{3}P_{0,1}^o$ states in neutral ytterbium by use of the available GRASP2018 package. From the resultant atomic state functions and the RIS4 extension, we evaluate the mass and field shift parameters for the $^{1}S_{0}-\,^{3}P_{0}^o$ (clock) and…
▽ More
Relativistic multiconfiguration Dirac-Hartree-Fock (MCDHF) calculations with configuration interaction (CI) are carried out for the $^{1}S_{0}$ and $^{3}P_{0,1}^o$ states in neutral ytterbium by use of the available GRASP2018 package. From the resultant atomic state functions and the RIS4 extension, we evaluate the mass and field shift parameters for the $^{1}S_{0}-\,^{3}P_{0}^o$ (clock) and $^{1}S_{0}-\,^{3}P_{1}^o$ (intercombination) lines. We present improved estimates of the nuclear charge parameters, $λ^{A,A'}$, and differences in mean-square charge radii, $δ\langle r^2\rangle^{A,A'}$, and examine the second-order hyperfine interaction for the $^{3}P_{0,1}^o$ states. Isotope shifts for the clock transition have been estimated by three largely independent means from which we predict the unknown clock line frequencies in bosonic Yb isotopes. Knowledge of these line frequencies has implications for King plot nonlinearity tests and the search for beyond Standard-Model signatures.
△ Less
Submitted 17 March, 2021; v1 submitted 17 February, 2021;
originally announced February 2021.
-
Fourier transform detection of weak optical transitions with cyclic routines
Authors:
Jesse S. Schelfhout,
Lilani D. Toms-Hardman,
John J. McFerran
Abstract:
We demonstrate a means of detecting weak optical transitions in cold atoms that undergo cyclic routines with high sensitivity. The gain in sensitivity is made by probing atoms on alternate cycles leading to a regular modulation of the ground state atom population when at the resonance frequency. The atomic transition is identified by conducting a fast Fourier transform via algorithm or instrument.…
▽ More
We demonstrate a means of detecting weak optical transitions in cold atoms that undergo cyclic routines with high sensitivity. The gain in sensitivity is made by probing atoms on alternate cycles leading to a regular modulation of the ground state atom population when at the resonance frequency. The atomic transition is identified by conducting a fast Fourier transform via algorithm or instrument. We find an enhancement of detection sensitivity compared to more conventional scanning methods of $\sim 20$ for the same sampling time, and can detect clock lines with fewer than $10^3$ atoms in a magneto-optical trap. We apply the method to the $(6s^{2})$ $ ^{1}S_{0} - (6s6p)$ $^{3}P_{0}$ clock transition in $^{171}$Yb and $^{173}$Yb. The ac-Stark shift of this line in $^{171}$Yb is measured to be 0.19(3) kHz$\cdot$W$^{-1}\cdot$m$^2$ at 556 nm.
△ Less
Submitted 22 October, 2020;
originally announced October 2020.
-
The SKA Particle Array Prototype: The First Particle Detector at the Murchison Radio-astronomy Observatory
Authors:
J. D. Bray,
A. Williamson,
J. Schelfhout,
C. W. James,
R. E. Spencer,
H. Chen,
B. D. Cropper,
D. Emrich,
K. M. L. Gould,
A. Haungs,
W. Hodder,
T. Howland,
T. Huege,
D. Kenney,
A. McPhail,
S. Mitchell,
I. C. Niţu,
P. Roberts,
R. Tawn,
J. Tickner,
S. J. Tingay
Abstract:
We report on the design, deployment, and first results from a scintillation detector deployed at the Murchison Radio-astronomy Observatory (MRO). The detector is a prototype for a larger array -- the Square Kilometre Array Particle Array (SKAPA) -- planned to allow the radio-detection of cosmic rays with the Murchison Widefield Array and the low-frequency component of the Square Kilometre Array. T…
▽ More
We report on the design, deployment, and first results from a scintillation detector deployed at the Murchison Radio-astronomy Observatory (MRO). The detector is a prototype for a larger array -- the Square Kilometre Array Particle Array (SKAPA) -- planned to allow the radio-detection of cosmic rays with the Murchison Widefield Array and the low-frequency component of the Square Kilometre Array. The prototype design has been driven by stringent limits on radio emissions at the MRO, and to ensure survivability in a desert environment. Using data taken from Nov.\ 2018 to Feb.\ 2019, we characterize the detector response while accounting for the effects of temperature fluctuations, and calibrate the sensitivity of the prototype detector to through-going muons. This verifies the feasibility of cosmic ray detection at the MRO. We then estimate the required parameters of a planned array of eight such detectors to be used to trigger radio observations by the Murchison Widefield Array.
△ Less
Submitted 2 June, 2020; v1 submitted 14 May, 2020;
originally announced May 2020.
-
Hyperfine constants and line separations for the $^{1}S_{0}-\,^{3}P_{1}$ intercombination line in neutral ytterbium with sub-Doppler resolution
Authors:
Peggy E. Atkinson,
Jesse S. Schelfhout,
John J. McFerran
Abstract:
Optical frequency measurements of the intercombination line $(6s^{2})\,^{1}S_{0} -(6s6p)\,^{3}P_{1}$ in the isotopes of ytterbium are carried out with the use of sub-Doppler fluorescence spectroscopy on an atomic beam. A dispersive signal is generated to which a master laser is locked, while frequency counting of an auxiliary beat signal is performed via a frequency comb referenced to a hydrogen m…
▽ More
Optical frequency measurements of the intercombination line $(6s^{2})\,^{1}S_{0} -(6s6p)\,^{3}P_{1}$ in the isotopes of ytterbium are carried out with the use of sub-Doppler fluorescence spectroscopy on an atomic beam. A dispersive signal is generated to which a master laser is locked, while frequency counting of an auxiliary beat signal is performed via a frequency comb referenced to a hydrogen maser. The relative separations between the lines are used to evaluate the $^{3}P_{1}$-level magnetic dipole and electric quadrupole constants for the fermionic isotopes. The center of gravity for the $^3P_1$ levels in $^{171}$Yb and $^{173}$Yb are also evaluated, where we find significant disagreement with previously reported values. These hyperfine constants provide a valuable litmus test for atomic many-body computations in ytterbium.
△ Less
Submitted 9 August, 2019;
originally announced August 2019.