Skip to main content

Showing 1–3 of 3 results for author: Scharfetter, H

.
  1. arXiv:2102.09955  [pdf, other

    eess.SP eess.IV physics.med-ph

    Joint multi-field T$_1$ quantification for fast field-cycling MRI

    Authors: Markus Bödenler, Oliver Maier, Rudolf Stollberger, Lionel M. Broche, P. James Ross, Mary-Joan MacLeod, Hermann Scharfetter

    Abstract: Purpose: Recent developments in hardware design enable the use of Fast Field-Cycling (FFC) techniques in MRI to exploit the different relaxation rates at very low field strength, achieving novel contrast. The method opens new avenues for in vivo characterisations of pathologies but at the expense of longer acquisition times. To mitigate this we propose a model-based reconstruction method that full… ▽ More

    Submitted 18 May, 2021; v1 submitted 19 February, 2021; originally announced February 2021.

    Comments: 25 pages + 9 supporting information, 8 figures and 2 tables in main text, 5 supporting figures; accepted in MRM; Markus Bödenler and Oliver Maier are equally contributing first authors

  2. R1 dispersion contrast at high field with fast field-cycling MRI

    Authors: Markus Bödenler, Martina Basini, Maria Francesca Casula, Evrim Umut, Christian Gösweiner, Andreas Petrovic, DanutaKruk, Hermann Scharfetter

    Abstract: Contrast agents with a strong $R_1$ dispersion have been shown to be effective in generating target-specific contrast in MRI. The utilization of this $R_1$ field dependence requires the adaptation of a MRI scanner for fast field-cycling (FFC). Here, we present the first implementation and validation of FFC-MRI at a clinical field strength of 3 T. A field-cycling range of $\pm$100 mT around the nom… ▽ More

    Submitted 18 October, 2018; originally announced October 2018.

  3. arXiv:1801.01299  [pdf

    physics.med-ph physics.ins-det

    A cryostatic, fast scanning, wideband NQR spectrometer for the VHF range

    Authors: Hermann Scharfetter, Markus Bödenler, Dominik Narnhofer

    Abstract: In the search for a novel MRI contrast agent which relies on T1 shortening due to quadrupolar interaction between Bi nuclei and protons, a fast scanning wideband system for zero-field nuclear quadrupole resonance (NQR) spectroscopy is required. Established NQR probeheads with motor-driven tune-match stages are usually bulky and slow, which can be prohibitive if it comes to Bi compounds with low SN… ▽ More

    Submitted 4 January, 2018; originally announced January 2018.

    Comments: 22 pages, 7figures, 2 tables

    Journal ref: J. Magn. Reson. 286 (2018) 148-157