Joint multi-field T$_1$ quantification for fast field-cycling MRI
Authors:
Markus Bödenler,
Oliver Maier,
Rudolf Stollberger,
Lionel M. Broche,
P. James Ross,
Mary-Joan MacLeod,
Hermann Scharfetter
Abstract:
Purpose: Recent developments in hardware design enable the use of Fast Field-Cycling (FFC) techniques in MRI to exploit the different relaxation rates at very low field strength, achieving novel contrast. The method opens new avenues for in vivo characterisations of pathologies but at the expense of longer acquisition times. To mitigate this we propose a model-based reconstruction method that full…
▽ More
Purpose: Recent developments in hardware design enable the use of Fast Field-Cycling (FFC) techniques in MRI to exploit the different relaxation rates at very low field strength, achieving novel contrast. The method opens new avenues for in vivo characterisations of pathologies but at the expense of longer acquisition times. To mitigate this we propose a model-based reconstruction method that fully exploits the high information redundancy offered by FFC methods. Methods: The proposed model-based approach utilizes joint spatial information from all fields by means of a Frobenius - total generalized variation regularization. The algorithm was tested on brain stroke images, both simulated and acquired from FFC patients scans using an FFC spin echo sequences. The results are compared to three non-linear least squares fits with progressively increasing complexity. Results: The proposed method shows excellent abilities to remove noise while maintaining sharp image features with large signal-to-noise ratio gains at low-field images, clearly outperforming the reference approach. Especially patient data shows huge improvements in visual appearance over all fields. Conclusion: The proposed reconstruction technique largely improves FFC image quality, further pushing this new technology towards clinical standards.
△ Less
Submitted 18 May, 2021; v1 submitted 19 February, 2021;
originally announced February 2021.
-
R1 dispersion contrast at high field with fast field-cycling MRI
Authors:
Markus Bödenler,
Martina Basini,
Maria Francesca Casula,
Evrim Umut,
Christian Gösweiner,
Andreas Petrovic,
DanutaKruk,
Hermann Scharfetter
Abstract:
Contrast agents with a strong $R_1$ dispersion have been shown to be effective in generating target-specific contrast in MRI. The utilization of this $R_1$ field dependence requires the adaptation of a MRI scanner for fast field-cycling (FFC). Here, we present the first implementation and validation of FFC-MRI at a clinical field strength of 3 T. A field-cycling range of $\pm$100 mT around the nom…
▽ More
Contrast agents with a strong $R_1$ dispersion have been shown to be effective in generating target-specific contrast in MRI. The utilization of this $R_1$ field dependence requires the adaptation of a MRI scanner for fast field-cycling (FFC). Here, we present the first implementation and validation of FFC-MRI at a clinical field strength of 3 T. A field-cycling range of $\pm$100 mT around the nominal $B_0$ field was realized by inserting an additional insert coil into an otherwise conventional MRI system. System validation was successfully performed with selected iron oxide magnetic nanoparticles and comparison to FFC-NMR relaxometry measurements. Furthermore, we show proof-of-principle $R_1$ dispersion imaging and demonstrate the capability of generating R1 dispersion contrast at high field with suppressed background signal. With the presented ready-to-use hardware setup it is possible to investigate MRI contrast agents with a strong R1 dispersion at a field strength of 3 T.
△ Less
Submitted 18 October, 2018;
originally announced October 2018.
-
A cryostatic, fast scanning, wideband NQR spectrometer for the VHF range
Authors:
Hermann Scharfetter,
Markus Bödenler,
Dominik Narnhofer
Abstract:
In the search for a novel MRI contrast agent which relies on T1 shortening due to quadrupolar interaction between Bi nuclei and protons, a fast scanning wideband system for zero-field nuclear quadrupole resonance (NQR) spectroscopy is required. Established NQR probeheads with motor-driven tune-match stages are usually bulky and slow, which can be prohibitive if it comes to Bi compounds with low SN…
▽ More
In the search for a novel MRI contrast agent which relies on T1 shortening due to quadrupolar interaction between Bi nuclei and protons, a fast scanning wideband system for zero-field nuclear quadrupole resonance (NQR) spectroscopy is required. Established NQR probeheads with motor-driven tune-match stages are usually bulky and slow, which can be prohibitive if it comes to Bi compounds with low SNR (excessive averaging) and long quadrupolar T1 times. Moreover many experiments yield better results at low temperatures such as 77K (liquid nitrogen, LN) thus requiring easy to use cryo-probeheads. In this paper we present electronically tuned wideband probeheads for bands in the frequency range 20 - 120 MHz which can be immersed in LN and which enable very fast explorative scans over the whole range. To this end we apply an interleaved subspectrum sampling strategy (ISS) which relies on the electronic tuning capability. The superiority of the new concept is demonstrated with an experimental scan of triphenylbismuth from 24-116 MHz both at room temperature and in LN. Especially for the first transition which exhibits extremely long T1 times (64ms) and low signal the new approach allows an acceleration factor by more than 100 when compared to classical methods.
△ Less
Submitted 4 January, 2018;
originally announced January 2018.