-
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 25 June, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Spatial resolution improvements with finer-pitch GEMs
Authors:
K. J. Flöthner,
L. Scharenberg,
A. Brask,
F. Brunbauer,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
M. Van Stenis,
R. Veenhof
Abstract:
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In t…
▽ More
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 um improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Single channel PICOSEC Micromegas detector with improved time resolution
Authors:
A. Utrobicic,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (25 additional authors not shown)
Abstract:
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo…
▽ More
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Characterisation of resistive MPGDs with 2D readout
Authors:
L. Scharenberg,
F. Brunbauer,
H. Danielson,
Z. Fang,
K. J. Flöthner,
F. Garcia,
D. Janssens,
M. Lisowska,
J. Liu,
Y. Lyu,
B. Mehl,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
O. Pizzirusso,
L. Ropelewski,
J. Samarati,
M. Shao,
A. Teixeira,
M. Van Stenis,
R. Veenhof,
Z. Zhang,
Y. Zhou
Abstract:
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detecto…
▽ More
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Studying signals in particle detectors with resistive elements such as the 2D resistive strip bulk MicroMegas
Authors:
Djunes Janssens,
Florian Brunbauer,
Karl Jonathan Flöthner,
Marta Lisowska,
Hans Muller,
Eraldo Oliveri,
Giorgio Orlandini,
Werner Riegler,
Leszek Ropelewski,
Heinrich Schindler,
Lucian Scharenberg,
Antonija Utrobicic,
Rob Veenhof
Abstract:
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$Ω$/$\Box$ 2D resistive strip bulk MM to calculate the signal'…
▽ More
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$Ω$/$\Box$ 2D resistive strip bulk MM to calculate the signal's spreading over neighbouring channels using an 80 GeV/c muon track. For this geometry, the dynamic weighting potential was obtained numerically using a finite element solver by applying a junction condition and coordinate scaling technique to accurately represent the boundary conditions of a $10\times 10$ cm$^2$ active area. Using test beam measurements, the results of this model will be used to benchmark this microscopic modelling methodology for signal induction in resistive particle detectors.
△ Less
Submitted 4 April, 2023;
originally announced April 2023.
-
A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution
Authors:
Antonija Utrobicic,
Yannis Angelis,
Stephan Aune,
Jonathan Bortfeldt,
Florian Brunbauer,
Evridiki Chatzianagnostou,
Klaus Dehmelt,
Daniel Desforge,
George Fanourakis,
Karl Jonathan Floethner,
Michele Gallinaro,
Francisco Garcia,
Prakhar Garg,
Ioannis Giomataris,
Kondo Gnanvo,
Thomas Gustavsson,
Francisco Jose Iguaz,
Djunes Janssens,
Alexandra Kallitsopoulou,
Marinko Kovacic,
Philippe Legou,
Marta Lisowska,
Jianbei Liu,
Michael Lupberger,
Simona Malace
, et al. (20 additional authors not shown)
Abstract:
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics exp…
▽ More
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.
△ Less
Submitted 31 March, 2023;
originally announced April 2023.
-
Towards robust PICOSEC Micromegas precise timing detectors
Authors:
Marta Lisowska,
Yannis Angelis,
Stephan Aune,
Jonathan Bortfeldt,
Florian Brunbauer,
Evridiki Chatzianagnostou,
Klaus Dehmelt,
Daniel Desforge,
George Fanourakis,
Karl Jonathan Floethner,
Michele Gallinaro,
Francisco Garcia,
Prakhar Garg,
Ioannis Giomataris,
Kondo Gnanvo,
Thomas Gustavsson,
Francisco Jose Iguaz,
Djunes Janssens,
Alexandra Kallitsopoulou,
Marinko Kovacic,
Philippe Legou,
Jianbei Liu,
Michael Lupberger,
Simona Malace,
Ioannis Maniatis
, et al. (21 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detec…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects; i.e. integration of resistive MM and carbon-based photocathodes; while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below 20 ps for an individual pad obtained with the 10x10 cm^2 area resistive PICOSEC MM of 20 MOhm/sq showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below 35 ps; opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
The novel XYU-GEM to resolve ambiguities
Authors:
K. J. Flöthner,
F. Brunbauer,
S. Ferry,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
F. Sauli,
L. Scharenberg,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was pr…
▽ More
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was proposed as a three coordinate strip-readout which is combined with a triple GEM detector. The readout complements a common XY readout with an additional projection which is tilted by 45°. The overdetermination due to three projections can be used to resovle ambiguities. Following the detector design will be explained, first measurements discussed to understand the response of the detector and a way to change the charge sharing without changing the manufacturing parameters of the readout.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates
Authors:
L. Scharenberg,
J. Bortfeldt,
F. Brunbauer,
K. Desch,
K. Flöthner,
F. Garcia,
D. Janssens,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
D. Sorvisto,
M. van Stenis,
R. Veenhof
Abstract:
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the…
▽ More
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the detectors at high rates (up to the MHz regime) with electronics time resolutions of the order of 1 ns and the ability to handle different detector types and sizes, due to a larger dynamic range compared to the previous front-end electronics based on the APV25 ASIC. Having studied and improved the beam telescope's performance over the course of three test beam campaigns, the results are presented in this paper.
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Authors:
I. Manthos,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
A. Kallitsopoulou,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Maniatis,
H. Müller,
E. Oliveri,
T. Papaevangelou
, et al. (19 additional authors not shown)
Abstract:
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stoc…
▽ More
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stochastically the dynamics of the signal formation, new PICOSEC designs were developed that significantly improve the timing performance of the detector. PICOSEC prototypes with reduced drift gap size ($\sim$\SI{119}{\micro\metre}) achieved a resolution of 45\,ps in timing single photons in laser beam tests (in comparison to 76\,ps of the standard PICOSEC detector). Towards large area detectors, multi-pad PICOSEC prototypes with segmented anodes has been developed and studied. Extensive tests in particle beams revealed that the multi-pad PICOSEC technology provides also very precise timing, even when the induced signal is shared among several neighbouring pads. Furthermore, new signal processing algorithms have been developed, which can be applied during data acquisition and provide real time, precise timing.
△ Less
Submitted 22 November, 2022;
originally announced November 2022.
-
Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications
Authors:
D. Pfeiffer,
F. Brunbauer,
R. Hall-Wilton,
M. Lupberger,
M. Marko,
H. Muller,
E. Oksanen,
E. Oliveri,
L. Ropelewski,
A. Rusu,
J. Samarati,
L. Scharenberg,
M. van Stenis,
P. Thuiner,
R. Veenhof
Abstract:
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of…
▽ More
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of the NMX detector prototype consisting of a Triple-GEM detector with natural Gd converter and a low material budget readout. The detector was successfully tested at the neutron reactor of the Budapest Neutron Centre (BNC) and at the D16 instrument at the Institut Laue-Langevin (ILL) in Grenoble. The measurements with Cadmium and Gadolinium masks in Budapest demonstrate that the point spread function of the detector lacks long tails that could impede the measurement of diffraction spot intensities. On the D16 instrument at ILL, diffraction spots from Triose phosphate isomerase w/ 2-phosphoglycolate (PGA) inhibitor were measured both in the D16 Helium-3 detector and the Gd-GEM. The comparison between the two detectors show a similar point spread function in both detectors, and the expected efficiency ratio compared to the Helium-3 detector. Both measurements together thus give good indications that the Gd-GEM detector fits the requirements for the NMX instrument at ESS.
△ Less
Submitted 16 March, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.
-
An automated testing system for the RD51 VMM hybrid and yield measurement of the first production batches
Authors:
Finn Jaekel,
Klaus Desch,
Jochen Kaminski,
Michael Lupberger,
Lucian Scharenberg,
Patrick Schwaebig
Abstract:
We present the development of an automated testing system for the VMM hybrid of the RD51 collaboration. The VMM hybrid is a new front-end board for the RD51 common readout system, the Scalable Readout System, and will become the workhorse for the next decade to read out Micro-Pattern Gaseous Detectors. It uses the VMM chip developed for the ATLAS New Small Wheel to convert charge signals from dete…
▽ More
We present the development of an automated testing system for the VMM hybrid of the RD51 collaboration. The VMM hybrid is a new front-end board for the RD51 common readout system, the Scalable Readout System, and will become the workhorse for the next decade to read out Micro-Pattern Gaseous Detectors. It uses the VMM chip developed for the ATLAS New Small Wheel to convert charge signals from detectors to digital data. Our testing system automatically characterises the quality of the VMM chips on the hybrid after production during multiple tests. Results are evaluated to classify the chips and hybrids and uploaded to a database. We evaluated those results for the first two production batches to measure the production yield. The yield is better than the threshold below which chip testing on a wafer level offers financial benefits. Observations on prominent chip failures were propagated back to the hybrid production process to further increase the yield for future productions.
△ Less
Submitted 31 May, 2022;
originally announced June 2022.
-
Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
Authors:
K. Dehmelt,
M. Della Pietra,
H. Muller,
S. E. Tzamarias,
A. White,
S. White,
Z. Zhang,
M. Alviggi,
I. Angelis,
S. Aune,
J. Bortfeldt,
M. Bregant,
F. Brunbauer,
M. T. Camerlingo,
V. Canale,
V. D'Amico,
D. Desforge,
C. Di Donato,
R. Di Nardo,
G. Fanourakis,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo
, et al. (45 additional authors not shown)
Abstract:
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51…
▽ More
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.
△ Less
Submitted 19 March, 2022; v1 submitted 12 March, 2022;
originally announced March 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System
Authors:
D. Pfeiffer,
L. Scharenberg,
P. Schwäbig,
S. Alcock,
F. Brunbauer,
M. J. Christensen,
K. Desch,
K. Flöthner,
F. Garcia,
R. Hall-Wilton,
M. Hracek,
G. Iakovidis,
D. Janssens,
J. Kaminski,
M. Lupberger,
H. Muller,
E. Oliveri,
L. Ropelewski,
A. Rusu,
J. Samarati,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use…
▽ More
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.
△ Less
Submitted 2 February, 2022; v1 submitted 21 September, 2021;
originally announced September 2021.
-
Timing performance of a multi-pad PICOSEC-Micromegas detector prototype
Authors:
S. Aune,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (17 additional authors not shown)
Abstract:
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we…
▽ More
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.
△ Less
Submitted 28 January, 2021; v1 submitted 1 December, 2020;
originally announced December 2020.
-
Optical Readout Studies of the Thick-COBRA Gaseous Detector
Authors:
F. Garcia,
F. M. Brunbauer,
M. Lisowska,
H. Müller,
E. Oliveri,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
F. Sauli,
L. Scharenberg,
A. L. M. Silva,
M. van Stenis,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The…
▽ More
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The preservation of spatial information from the initial ionizations was demonstrated by analyzing the light emission from 5.9keV X-rays of an 55Fe source. The observed non-uniformity of the scintillation light from the holes supports the claim of a space localization accuracy better than the pitch of the holes. The acquired images were used to identify weak points and sources of instabilities in view of the development of new optimized structures.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Performance of a GridPix TPC readout based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
M. Gruber,
F. Hartjes,
J. Kaminski,
N. van der Kolk,
P. M. Kluit,
G. Raven,
L. Scharenberg,
T. Schiffer,
S. Schmidt,
J. Timmermans
Abstract:
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the reado…
▽ More
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the readout plane is dominated by diffusion. Systematic uncertainties are limited to below 10 $μ$m. The GridPix can detect single ionization electrons with high efficiency, which allows for energy loss measurements and particle identification. From a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m. Using the same type of chips, a Quad module was developed that can be tiled to cover a TPC readout plane at the ILC. Simulation studies show that a pixel readout can improve the momentum resolution of a TPC at the ILC by about 20%.
△ Less
Submitted 5 February, 2019;
originally announced February 2019.
-
Modeling the Timing Characteristics of the PICOSEC Micromegas Detector
Authors:
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T . Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (16 additional authors not shown)
Abstract:
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations ba…
▽ More
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations based on GARFIELD++ reproduce the experimental PICOSEC timing characteristics. This agreement is exploited to identify the microscopic physical variables, which determine the observed timing properties. In these studies, several counter-intuitive observations are made for the behavior of such microscopic variables. In order to gain insight on the main physical mechanisms causing the observed behavior, a phenomenological model is constructed and presented. The model is based on a simple mechanism of "time-gain per interaction" and it employs a statistical description of the avalanche evolution. It describes quantitatively the dynamical and statistical properties of the microscopic quantities, which determine the PICOSEC timing characteristics, in excellent agreement with the simulations. In parallel, it offers phenomenological explanations for the behavior of these microscopic variables. The formulae expressing this model can be used as a tool for fast and reliable predictions, provided that the input parameter values (e.g. drift velocities) are known for the considered operating conditions.
△ Less
Submitted 2 December, 2020; v1 submitted 30 January, 2019;
originally announced January 2019.