Improving image quality of sparse-view lung tumor CT images with U-Net
Authors:
Annika Ries,
Tina Dorosti,
Johannes Thalhammer,
Daniel Sasse,
Andreas Sauter,
Felix Meurer,
Ashley Benne,
Tobias Lasser,
Franz Pfeiffer,
Florian Schaff,
Daniela Pfeiffer
Abstract:
Background: We aimed at improving image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determining the best tradeoff between number of views, IQ, and diagnostic confidence.
Methods: CT images from 41 subjects aged 62.8 $\pm$ 10.6 years (mean $\pm$ standard deviation), 23 men, 34 with lung metastasis, 7 healthy, were retrospectively sel…
▽ More
Background: We aimed at improving image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determining the best tradeoff between number of views, IQ, and diagnostic confidence.
Methods: CT images from 41 subjects aged 62.8 $\pm$ 10.6 years (mean $\pm$ standard deviation), 23 men, 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used.
Results: The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images.
Conclusions: Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level.
△ Less
Submitted 14 February, 2024; v1 submitted 28 July, 2023;
originally announced July 2023.
-
Improving Automated Hemorrhage Detection in Sparse-view Computed Tomography via Deep Convolutional Neural Network based Artifact Reduction
Authors:
Johannes Thalhammer,
Manuel Schultheiss,
Tina Dorosti,
Tobias Lasser,
Franz Pfeiffer,
Daniela Pfeiffer,
Florian Schaff
Abstract:
Purpose: Sparse-view computed tomography (CT) is an effective way to reduce dose by lowering the total number of views acquired, albeit at the expense of image quality, which, in turn, can impact the ability to detect diseases. We explore deep learning-based artifact reduction in sparse-view cranial CT scans and its impact on automated hemorrhage detection. Methods: We trained a U-Net for artefact…
▽ More
Purpose: Sparse-view computed tomography (CT) is an effective way to reduce dose by lowering the total number of views acquired, albeit at the expense of image quality, which, in turn, can impact the ability to detect diseases. We explore deep learning-based artifact reduction in sparse-view cranial CT scans and its impact on automated hemorrhage detection. Methods: We trained a U-Net for artefact reduction on simulated sparse-view cranial CT scans from 3000 patients obtained from a public dataset and reconstructed with varying levels of sub-sampling. Additionally, we trained a convolutional neural network on fully sampled CT data from 17,545 patients for automated hemorrhage detection. We evaluated the classification performance using the area under the receiver operator characteristic curves (AUC-ROCs) with corresponding 95% confidence intervals (CIs) and the DeLong test, along with confusion matrices. The performance of the U-Net was compared to an analytical approach based on total variation (TV). Results: The U-Net performed superior compared to unprocessed and TV-processed images with respect to image quality and automated hemorrhage diagnosis. With U-Net post-processing, the number of views can be reduced from 4096 (AUC-ROC: 0.974; 95% CI: 0.972-0.976) views to 512 views (0.973; 0.971-0.975) with minimal decrease in hemorrhage detection (P<.001) and to 256 views (0.967; 0.964-0.969) with a slight performance decrease (P<.001). Conclusion: The results suggest that U-Net based artifact reduction substantially enhances automated hemorrhage detection in sparse-view cranial CTs. Our findings highlight that appropriate post-processing is crucial for optimal image quality and diagnostic accuracy while minimizing radiation dose.
△ Less
Submitted 24 July, 2023; v1 submitted 16 March, 2023;
originally announced March 2023.
-
Optimizing Convolutional Neural Networks for Chronic Obstructive Pulmonary Disease Detection in Clinical Computed Tomography Imaging
Authors:
Tina Dorosti,
Manuel Schultheiss,
Felix Hofmann,
Johannes Thalhammer,
Luisa Kirchner,
Theresa Urban,
Franz Pfeiffer,
Florian Schaff,
Tobias Lasser,
Daniela Pfeiffer
Abstract:
We aim to optimize the binary detection of Chronic Obstructive Pulmonary Disease (COPD) based on emphysema presence in the lung with convolutional neural networks (CNN) by exploring manually adjusted versus automated window-setting optimization (WSO) on computed tomography (CT) images. 7,194 CT images (3,597 with COPD; 3,597 healthy controls) from 78 subjects (43 with COPD; 35 healthy controls) we…
▽ More
We aim to optimize the binary detection of Chronic Obstructive Pulmonary Disease (COPD) based on emphysema presence in the lung with convolutional neural networks (CNN) by exploring manually adjusted versus automated window-setting optimization (WSO) on computed tomography (CT) images. 7,194 CT images (3,597 with COPD; 3,597 healthy controls) from 78 subjects (43 with COPD; 35 healthy controls) were selected retrospectively (10.2018-12.2019) and preprocessed. For each image, intensity values were manually clipped to the emphysema window setting and a baseline 'full-range' window setting. Class-balanced train, validation, and test sets contained 3,392, 1,114, and 2,688 images. The network backbone was optimized by comparing various CNN architectures. Furthermore, automated WSO was implemented by adding a customized layer to the model. The image-level area under the Receiver Operating Characteristics curve (AUC) [lower, upper limit 95% confidence] was utilized to compare model variations. Repeated inference (n=7) on the test set showed that the DenseNet was the most efficient backbone and achieved a mean AUC of 0.80 [0.76, 0.85] without WSO. Comparably, with input images manually adjusted to the emphysema window, the DenseNet model predicted COPD with a mean AUC of 0.86 [0.82, 0.89]. By adding a customized WSO layer to the DenseNet, an optimal window in the proximity of the emphysema window setting was learned automatically, and a mean AUC of 0.82 [0.78, 0.86] was achieved. Detection of COPD with DenseNet models was improved by WSO of CT data to the emphysema window setting range.
△ Less
Submitted 12 October, 2023; v1 submitted 13 March, 2023;
originally announced March 2023.
-
Full field X-ray Scatter Tomography
Authors:
Gary Ruben,
Isaac Pinar,
Jeremy M. C. Brown,
Florian Schaff,
James A. Pollock,
Kelly J. Crossley,
Anton Maksimenko,
Chris Hall,
Daniel Hausermann,
Kentaro Uesugi,
Marcus J. Kitchen
Abstract:
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat.…
▽ More
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.
△ Less
Submitted 10 March, 2022; v1 submitted 16 December, 2020;
originally announced December 2020.
-
Material decomposition from a single x-ray projection via single-grid phase contrast imaging
Authors:
Celebrity F. Groenendijk,
Florian Schaff,
Linda C. P. Croton,
Marcus J. Kitchen,
Kaye S. Morgan
Abstract:
This study describes a new approach for material decomposition in x-ray imaging, utilising phase contrast to both increase sensitivity to weakly-attenuating samples and to act as a complementary measurement to attenuation, therefore allowing two overlaid materials to be separated. The measurements are captured using the single-exposure, single-grid x-ray phase contrast imaging technique, with a no…
▽ More
This study describes a new approach for material decomposition in x-ray imaging, utilising phase contrast to both increase sensitivity to weakly-attenuating samples and to act as a complementary measurement to attenuation, therefore allowing two overlaid materials to be separated. The measurements are captured using the single-exposure, single-grid x-ray phase contrast imaging technique, with a novel correction that aims to remove propagation-based phase effects seen at sharp edges in the attenuation image. The use of a single-exposure technique means that images could be collected in a high-speed sequence. Results are shown for both a known two-material sample and for a biological specimen.
△ Less
Submitted 8 February, 2020;
originally announced February 2020.
-
Material Decomposition using Spectral Propagation-based Phase Contrast X-ray Imaging
Authors:
Florian Schaff,
Kaye S. Morgan,
James A. Pollock,
Linda C. P. Croton,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly atten…
▽ More
Material decomposition in X-ray imaging uses the energy-dependence of attenuation to virtually decompose an object into specific constituent materials. X-ray phase contrast imaging is a develo** technique that can enhance image contrast seen from weakly attenuating objects. In this paper, we combine spectral phase contrast imaging with material decomposition to both better visualise weakly attenuating features and separate them from overlying objects in radiography. We derive an algorithm that performs both tasks simultaneously and verify it against numerical simulations and experimental measurements of ideal two-component samples composed of pure aluminium and poly(methyl methacrylate). Additionally, we showcase first imaging results of a rabbit kitten's lung. The attenuation signal of a thorax, in particular, is dominated by the strongly attenuating bones of the ribcage, which combined with the weak soft tissue signal make it difficult to visualise the fine anatomical structures across the whole lung. In all cases, clean material decomposition was achieved, without residual phase contrast effects, from which we generate an un-obstructed image of the lung, free of bones. Spectral propagation-based phase contrast imaging has the potential to be a valuable tool, not only in future lung research, but also in other systems for which phase contrast imaging in combination with material decomposition proves to be advantageous.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.