-
Identification of particles with Lorentz factor up to $10^{4}$ with Transition Radiation Detectors based on micro-strip silicon detectors
Authors:
J. Alozy,
N. Belyaev,
M. Campbell,
M. Cherry,
F. Dachs,
S. Doronin,
K. Filippov,
P. Fusco,
F. Gargano,
E. Heijne,
S. Konovalov,
D. Krasnopevtsev,
X. Llopart,
F. Loparco,
V. Mascagna,
M. N. Mazziotta,
H. Pernegger,
D. Ponomarenko,
M. Prest,
D. Pyatiizbyantseva,
R. Radomskii,
C. Rembser,
A. Romaniouk,
A. A. Savchenko,
D. Schaefer
, et al. (17 additional authors not shown)
Abstract:
This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to the radiating particles. A detector setup has been built and tested with particles in a wide range of Lorentz factors (from about $10^3$ to about…
▽ More
This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to the radiating particles. A detector setup has been built and tested with particles in a wide range of Lorentz factors (from about $10^3$ to about $4 \times 10^4$ crossing different types of radiators. The measured double-differential (in energy and angle) spectra of the TR photons are in a reasonably good agreement with TR simulation predictions.
△ Less
Submitted 22 February, 2019; v1 submitted 31 January, 2019;
originally announced January 2019.
-
Geant4 simulations of the lead fluoride calorimeter
Authors:
A. A. Savchenko,
A. A. Tishchenko,
S. B. Dabagov,
A. Anastasi,
G. Venanzoni,
M. N. Strikhanov
Abstract:
In this paper we simulate the emission by charged particles in complex structures with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module (24 are expected in the experi…
▽ More
In this paper we simulate the emission by charged particles in complex structures with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module (24 are expected in the experiment) consists of a Delrin front panel for installation of the laser calibration system, 54 PbF2 Cherenkov crystals wrapped by the black Millipore paper, and silicon photo-multiplier sensors. We report here on a simulation of radiation from positrons passing through the calorimeter system. We carry out the simulation using Geant4 toolkit, which provides a complete set of tools for all areas of detector simulation: geometry, tracking, detector response, run, event and track management, and visualization. We consider Cherenkov photons expansion when a positron moves down through the calorimeter at the arbitrary angle of incidence. Both spectral and angular distributions of Cherenkov optical photons in different parts of the calorimeter system have been evaluated as well as the transition radiation and pre-shower distributions from the panel and from the Al vacuum chamber of the storage ring. (The paper is in progress).
△ Less
Submitted 10 December, 2016; v1 submitted 30 November, 2016;
originally announced November 2016.
-
The transverse momentum dependence of charged kaon Bose-Einstein correlations in the SELEX experiment
Authors:
SELEX Collaboration,
G. A. Nigmatkulov,
A. K. Ponosov,
U. Akgun,
G. Alkhazov,
J. Amaro-Reyes,
A. Asratyan,
A. G. Atamantchouk,
A. S. Ayan,
M. Y. Balatz,
A. Blanco-Covarrubias,
N. F. Bondar,
P. S. Cooper,
L. J. Dauwe,
G. V. Davidenko,
U. Dersch,
A. G. Dolgolenko,
G. B. Dzyubenko,
R. Edelstein,
L. Emediato,
A. M. F. Endler,
J. Engelfried,
I. Eschrich,
C. O. Escobar,
N. Estrada
, et al. (79 additional authors not shown)
Abstract:
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlatio…
▽ More
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlation strength, $λ$, are extracted. The analysis shows a decrease of the source radii with increasing kaon transverse pair momentum for all beam types.
△ Less
Submitted 14 November, 2015; v1 submitted 18 January, 2015;
originally announced January 2015.