-
Performance of the polarization leakage correction in the PILOT data
Authors:
J-Ph. Bernard,
A. Bernard,
H. Roussel,
I. Choubani,
D. Alina,
J. Aumont,
A. Hughes,
I. Ristorcelli,
S. Stever,
T. Matsumura S. Sugiyama,
K. Komatsu,
G. de Gasperis,
K. Ferriere,
V. Guillet,
N. Ysard,
P. Ade,
P. de Bernardis,
N. Bray,
B. Crane,
J. P. Dubois,
M. Griffin,
P. Hargrave,
Y. Longval,
S. Louvel,
B. Maffei
, et al. (11 additional authors not shown)
Abstract:
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment that aims to measure the polarized emission of thermal dust at a wavelength of 240 um (1.2 THz). The PILOT experiment flew from Timmins, Ontario, Canada in 2015 and 2019 and from Alice Springs, Australia in April 2017. The in-flight performance of the instrument during…
▽ More
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment that aims to measure the polarized emission of thermal dust at a wavelength of 240 um (1.2 THz). The PILOT experiment flew from Timmins, Ontario, Canada in 2015 and 2019 and from Alice Springs, Australia in April 2017. The in-flight performance of the instrument during the second flight was described in Mangilli et al. 2019. In this paper, we present data processing steps that were not presented in Mangilli et al. 2019 and that we have recently implemented to correct for several remaining instrumental effects. The additional data processing concerns corrections related to detector cross-talk and readout circuit memory effects, and leakage from total intensity to polarization. We illustrate the above effects and the performance of our corrections using data obtained during the third flight of PILOT, but the methods used to assess the impact of these effects on the final science-ready data, and our strategies for correcting them will be applied to all PILOT data. We show that the above corrections, and in particular that for the intensity to polarization leakage, which is most critical for accurate polarization measurements with PILOT, are accurate to better than 0.4 % as measured on Jupiter during flight#3.
△ Less
Submitted 7 May, 2022;
originally announced May 2022.
-
BISOU: a balloon project to measure the CMB spectral distortions
Authors:
B. Maffei,
M. H. Abitbol,
N. Aghanim,
J. Aumont,
E. Battistelli,
J. Chluba,
X. Coulon,
P. De Bernardis,
M. Douspis,
J. Grain,
S. Gervasoni,
J. C. Hill,
A. Kogut,
S. Masi,
T. Matsumura,
C. O Sullivan,
L. Pagano,
G. Pisano,
M. Remazeilles,
A. Ritacco,
A. Rotti,
V. Sauvage,
G. Savini,
S. L. Stever,
A. Tartari
, et al. (2 additional authors not shown)
Abstract:
The BISOU (Balloon Interferometer for Spectral Observations of the Universe) project aims to study the viability and prospects of a balloon-borne spectrometer, pathfinder of a future space mission dedicated to the measurements of the CMB spectral distortions. We present here a preliminary concept based on previous space mission proposals, together with some sensitivity calculation results for the…
▽ More
The BISOU (Balloon Interferometer for Spectral Observations of the Universe) project aims to study the viability and prospects of a balloon-borne spectrometer, pathfinder of a future space mission dedicated to the measurements of the CMB spectral distortions. We present here a preliminary concept based on previous space mission proposals, together with some sensitivity calculation results for the observation goals, showing that a 5-sigma measurement of the y-distortions is achievable.
△ Less
Submitted 30 October, 2021;
originally announced November 2021.
-
Benefits of bolometer Joule step** and Joule pulsing
Authors:
Samantha Lynn Stever,
François Couchot,
Valentin Sauvage,
Noël Coron
Abstract:
We introduce the `Joule step**' technique, whereupon a constantly-biased bolometer has its bias voltage modified by a small additional step. We demonstrate this technique using a composite NTD semiconductor bolometer and a pulsing device which sends an extra step in voltage. We demonstrate the results of the technique over a range of bias voltages at 100, 200, and 300 mK. We find that Joule step…
▽ More
We introduce the `Joule step**' technique, whereupon a constantly-biased bolometer has its bias voltage modified by a small additional step. We demonstrate this technique using a composite NTD semiconductor bolometer and a pulsing device which sends an extra step in voltage. We demonstrate the results of the technique over a range of bias voltages at 100, 200, and 300 mK. We find that Joule step** allows us to directly measure long thermal tails with low amplitudes in the bolometer response, and could be a useful tool for quickly and easily understanding response functions of bolometric detectors. We also show that the derivative of the Joule step is equivalent to the bolometer response to a $δ$-pulse (or Joule pulse), which allows for greater understanding of fast transient behaviour.
△ Less
Submitted 8 December, 2019;
originally announced December 2019.