Abstract:
The Silicon photomultiplier-based Compton Telescope for Safety and Security (SCoTSS) has been developed incorporating end-user requirements into the design process. The end-user group includes those responsible for mobile survey in the event of a radiological or nuclear accident, those responsible for radiation survey support to security operations at major events and at Canadian borders, as well…
▽ More
The Silicon photomultiplier-based Compton Telescope for Safety and Security (SCoTSS) has been developed incorporating end-user requirements into the design process. The end-user group includes those responsible for mobile survey in the event of a radiological or nuclear accident, those responsible for radiation survey support to security operations at major events and at Canadian borders, as well as some of those responsible for Canadian defense applications. The SCoTSS development program has reached a technology readiness level of eight, and we are proceeding with field trials of the instrument in high-fidelity operational environments. Prospective end users have been involved in trial set up and execution, assuring applicability in their mission spaces. SCoTSS has been subject to trials involving hidden sources, heavily shielded sources, imager moving with respect to source, and complicated man-made surroundings. Our operators value high sensitivity for anomaly geolocation and map**. End users also require an instrument which is capable of direction reconstruction in motion, as well as rapid imaging of a field of view. We have developed a "time to image" measure which allows for quantitative comparison of imagers of fundamentally different technology, where one design may have an advantage in terms of energy resolution and compactness and another design may have an advantage in terms of efficiency and cost effectiveness. We present here the performance of the SCoTSS imager in rapid direction finding. As well, we compare the time to image quantity for the SCoTSS imager and the H3D Polaris-H Quad imager where the data were taken under equivalent conditions. This quantitative measure of imaging performance can allow operators to make an informed choice of the design that meets their needs taking into consideration also weight and size as well as budgetary constraints.
△ Less
Submitted 10 January, 2020;
originally announced January 2020.
-
Which is better, a SCoTSS gamma imager, or an ARDUO UAV-borne directional detector?
Authors:
Andrew McCann,
Laurel E. Sinclair,
Patrick R. B. Saull,
Christian Van Ouellet,
Richard Fortin,
Carolyn Chen,
Maurice J. Coyle,
Rodger Mantifel,
Audrey M. L. MacLeod,
Reid A. Van Brabant,
John Buckle,
Pierre-Luc Drouin,
Jens Hovgaard,
Bohdan Krupskyy,
Blake Beckman,
Blaine Fairbrother
Abstract:
The SiPM-based Compton Telescope for Safety and Security (SCoTSS) has been developed with inorganic crystalline scintillator material for gamma detection. The instrument is sensitive enough to be used in a mobile survey mode, accumulating energy deposited in any crystal second-by-second and tagging these spectra with GPS position. The SCoTSS imager of course has the additional advantage of being a…
▽ More
The SiPM-based Compton Telescope for Safety and Security (SCoTSS) has been developed with inorganic crystalline scintillator material for gamma detection. The instrument is sensitive enough to be used in a mobile survey mode, accumulating energy deposited in any crystal second-by-second and tagging these spectra with GPS position. The SCoTSS imager of course has the additional advantage of being able to produce an image of the radioactive objects in its field of view using events that satisfy a coincidence trigger between the scatter and absorber layers. The Advanced Radiation Detector for UAV Operations (ARDUO) on the other hand, is a non-imaging directional detector intended for use aboard a small unmanned aerial vehicle (UAV). The ARDUO detector features exactly the same volume of CsI(Tl) as is used in the absorber layer of a single SCoTSS module, giving it similar detection and alarming sensitivity, and map-making capability. However, in the ARDUO detector, the crystals are arranged closely together to optimize direction determination from self-shielding effects. Flown in a grid pattern with a UAV over an area of extended contamination, the ARDUO detector is also capable of making a map or image of that area. With its close-packed crystal arrangement, the ARDUO detector makes a poor Compton imager but does have some ability to produce a peripheral image in a fly-by. In this presentation we investigate the relative merits of Compton imaging versus mobile directional detection.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
Silicon photomultiplier-based Compton Telescope for Safety and Security (SCoTSS)
Authors:
Laurel E. Sinclair,
Patrick R. B. Saull,
David S. Hanna,
Henry C. J. Seywerd,
Audrey M. L. MacLeod,
Patrick J. Boyle
Abstract:
A Compton gamma imager has been developed for use in consequence management operations and in security investigations. The imager uses solid inorganic scintillator, known for robust performance in field survey conditions. The design was constrained in overall size by the requirement that it be person transportable and operable from a variety of platforms. In order to introduce minimal dead materia…
▽ More
A Compton gamma imager has been developed for use in consequence management operations and in security investigations. The imager uses solid inorganic scintillator, known for robust performance in field survey conditions. The design was constrained in overall size by the requirement that it be person transportable and operable from a variety of platforms. In order to introduce minimal dead material in the path of the incoming and scattered gamma rays, custom silicon photomultipliers (SiPMs), with a thin glass substrate, were used to collect the scintillation light from the scatter layers. To move them out of the path of the gamma rays, preamplification electronics for the silicon photomultipliers were located a distance from the imager. This imager, the Silicon photomultiplier Compton Telescope for Safety and Security (SCoTSS) is able to provide a one-degree image resolution in a plus-minus 45 degree field of view for a 10 mCi point source 40 m distant, within about one minute, for gamma-ray energies ranging from 344 keV to 1274 keV. Here, we present a comprehensive performance study of the SCoTSS imager.
△ Less
Submitted 8 January, 2016;
originally announced January 2016.
-
Development of a Compton imager based on bars of scintillator
Authors:
A. M. L. MacLeod,
P. J. Boyle,
D. S. Hanna,
P. R. B. Saull,
L. E. Sinclair,
H. C. J. Seywerd
Abstract:
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and absorber) employ bars of NaI(Tl) read out by photomultiplier tubes (PMTs) located at each end. The long-range imaging performance has been tested from 392 keV…
▽ More
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and absorber) employ bars of NaI(Tl) read out by photomultiplier tubes (PMTs) located at each end. The long-range imaging performance has been tested from 392 keV to 1274 keV. An angular resolution measure of 2.72 +/- 0.06 degrees and an efficiency of (1.79 +/- 0.04) x 10^(-3) at 662 keV is obtained. A Cs-137 (662 keV) source equivalent to a 10 mCi source 40 m away can be located in 60 seconds with an uncertainty of about a degree. No significant degradation in imaging performance is observed for source angles up to 40 degrees off axis.
△ Less
Submitted 16 June, 2015;
originally announced June 2015.
-
First demonstration of a Compton gamma imager based on silicon photomultipliers
Authors:
P. R. B. Saull,
L. E. Sinclair,
H. C. J. Seywerd,
D. S. Hanna,
P. J. Boyle,
A. M. L. MacLeod
Abstract:
We are develo** a rugged and person-transportable Compton gamma imager for use in security investigations of radioactive materials, and for radiological incident remediation. The imager is composed of layers of scintillator with light collection for the forward layers provided by silicon photomultipliers and for the rear layer by photomultiplier tubes. As a first step, we have developed a 1/5th-…
▽ More
We are develo** a rugged and person-transportable Compton gamma imager for use in security investigations of radioactive materials, and for radiological incident remediation. The imager is composed of layers of scintillator with light collection for the forward layers provided by silicon photomultipliers and for the rear layer by photomultiplier tubes. As a first step, we have developed a 1/5th-scale demonstration unit of the final imager. We present the imaging performance of this demonstration unit for Cs-137 at angles of up to 30 degrees off-axis. Results are also presented for Sn-113 and Na-22. This represents the first demonstration of the use of silicon photomultipliers as an embedded component for light collection in a Compton gamma imager.
△ Less
Submitted 3 July, 2012;
originally announced July 2012.
-
Aerial Measurement of Radioxenon Concentration off the West Coast of Vancouver Island following the Fukushima Reactor Accident
Authors:
L. E. Sinclair,
H. C. J. Seywerd,
R. Fortin,
J. M. Carson,
P. R. B. Saull,
M. J. Coyle,
R. A. Van Brabant,
J. L. Buckle,
S. M. Desjardins,
R. M. Hall
Abstract:
In response to the Fukushima nuclear reactor accident, on March 20th, 2011, Natural Resources Canada conducted aerial radiation surveys over water just off of the west coast of Vancouver Island. Dose-rate levels were found to be consistent with background radiation, however a clear signal due to Xe-133 was observed. Methods to extract Xe-133 count rates from the measured spectra, and to determine…
▽ More
In response to the Fukushima nuclear reactor accident, on March 20th, 2011, Natural Resources Canada conducted aerial radiation surveys over water just off of the west coast of Vancouver Island. Dose-rate levels were found to be consistent with background radiation, however a clear signal due to Xe-133 was observed. Methods to extract Xe-133 count rates from the measured spectra, and to determine the corresponding Xe-133 volumetric concentration, were developed. The measurements indicate that Xe-133 concentrations on average lie in the range of 30 to 70 Bq/m3.
△ Less
Submitted 20 June, 2011;
originally announced June 2011.
-
Simulations of a Scintillator Compton Gamma Imager for Safety and Security
Authors:
L. E. Sinclair,
D. S. Hanna,
A. M. L. MacLeod,
P. R. B. Saull
Abstract:
We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid scintillator for the active volumes of both the scatter and absorber detectors. Using the BEAMnrc/EGSnrc Monte Carlo simulation package, we have constructed mo…
▽ More
We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid scintillator for the active volumes of both the scatter and absorber detectors. Using the BEAMnrc/EGSnrc Monte Carlo simulation package, we have constructed models using four different materials for the scatter detector: LaBr_3, NaI, CaF_2 and PVT. We have compared the detector performances using angular resolution, efficiency, and image resolution. We find that while PVT provides worse performance than that of the detectors based entirely on inorganic scintillators, all of the materials investigated for the scatter detector have the potential to provide performance adequate for our purposes.
△ Less
Submitted 28 June, 2009; v1 submitted 24 September, 2008;
originally announced September 2008.
-
Prompt Photon Production and Observation of Deeply Virtual Compton Scattering
Authors:
P. R. B. Saull
Abstract:
Two recent results in ep physics using the ZEUS detector at HERA are discussed: a measurement of the prompt photon production cross section in photoproduction, and the first observation of Deeply Virtual Compton Scattering in DIS.
Two recent results in ep physics using the ZEUS detector at HERA are discussed: a measurement of the prompt photon production cross section in photoproduction, and the first observation of Deeply Virtual Compton Scattering in DIS.
△ Less
Submitted 27 March, 2000;
originally announced March 2000.