-
Three-axis torque investigation of interfacial exchange coupling in a NiFe/CoO bilayer micromagnetic disk
Authors:
M. G. Dunsmore,
J. A. Thibault,
K. R. Fast,
V. T. K. Sauer,
J. E. Losby,
Z. Diao,
M. Belov,
M. R. Freeman
Abstract:
Micrometer diameter bilayers of NiFe (permalloy, Py) and cobalt oxide (CoO) deposited on nanomechanical resonators were used to investigate exchange bias effects. The mechanical compliances of two resonator axes were enhanced by severing one torsion arm, resulting in a unique three-axis resonator that responds resonantly to torques generated by a three-axis RF field. Our technique permits simultan…
▽ More
Micrometer diameter bilayers of NiFe (permalloy, Py) and cobalt oxide (CoO) deposited on nanomechanical resonators were used to investigate exchange bias effects. The mechanical compliances of two resonator axes were enhanced by severing one torsion arm, resulting in a unique three-axis resonator that responds resonantly to torques generated by a three-axis RF field. Our technique permits simultaneous measurement of three orthogonal torque components. Measurements of the anisotropies associated with interfacial exchange coupling effects have been made. At cryogenic temperatures, observations of shifted linear hysteresis loops confirmed the presence of exchange bias from the Py/CoO interface. An in-plane rotating DC bias field was used to probe in-plane anisotropies through the out-of-plane torque. Training effects in the rotational hysteresis data were observed and showed that features due to interfacial coupling did not diminish irrespective of substantial training of the unidirectional anisotropy. The data from the rotational hysteresis loops were fit with parameters from a macrospin solution to the Landau-Lifshitz-Gilbert equation. Each parameter of the exchange bias model accounts for specific features of the rotational loop.
△ Less
Submitted 4 February, 2022;
originally announced February 2022.
-
Simultaneous three-axis torque measurements of micromagnetism
Authors:
K. R. Fast,
J. A. Thibault,
V. T. K. Sauer,
M. G. Dunsmore,
A. Kav,
J. E. Losby,
Z. Diao,
E. J. Luber,
M. Belov,
M. R. Freeman
Abstract:
Measurements of magnetic torque are most commonly preformed about a single axis or component of torque. Such measurements are very useful for hysteresis measurements of thin film structures in particular, where high shape anisotropy yields a near-proportionality of in-plane magnetic moment and the magnetic torque along the perpendicular in-plane axis. A technique to measure the full magnetic torqu…
▽ More
Measurements of magnetic torque are most commonly preformed about a single axis or component of torque. Such measurements are very useful for hysteresis measurements of thin film structures in particular, where high shape anisotropy yields a near-proportionality of in-plane magnetic moment and the magnetic torque along the perpendicular in-plane axis. A technique to measure the full magnetic torque vector (three orthogonal torque components) on micro- and nano-scale magnetic materials is introduced. The method is demonstrated using a modified, single-paddle silicon-on-insulator resonant torque sensor. The mechanical compliances to all three orthogonal torque components are maximized by clam** the sensor at a single point. Mechanically-resonant AC torques are driven by an RF field containing a frequency component for each fundamental torsional mode of the device, and the resulting displacements read out through optical position-sensitive detection. The measurements are compared with micromagnetic simulations of the mechanical torque to augment the interpretation of the signals. As an application example, simultaneous observations of hysteresis in the net magnetization along with the field-dependent in-plane anisotropy is highly beneficial for studies of exchange bias.
△ Less
Submitted 2 November, 2020;
originally announced November 2020.
-
Two-axis cavity optomechanical torque characterization of magnetic microstructures
Authors:
Ghazal Hajisalem,
Joseph E. Losby,
Gustavo de Oliveira Luiz,
Vincent T. K. Sauer,
Paul E. Barclay,
Mark R. Freeman
Abstract:
Significant new functionality is reported for torsion mechanical tools aimed at full magnetic characterizations of both spin statics and dynamics in micro- and nanostructures. Specifically, two orthogonal torque directions are monitored and the results co-analyzed to separate magnetic moment and magnetic susceptibility contributions to torque, as is desired for characterization of anisotropic thre…
▽ More
Significant new functionality is reported for torsion mechanical tools aimed at full magnetic characterizations of both spin statics and dynamics in micro- and nanostructures. Specifically, two orthogonal torque directions are monitored and the results co-analyzed to separate magnetic moment and magnetic susceptibility contributions to torque, as is desired for characterization of anisotropic three-dimensional structures. The approach is demonstrated through application to shape and microstructural disorder-induced magnetic anisotropies in lithographically patterned permalloy, and will have utility for the determination of important magnetic thin-film and multilayer properties including interface anisotropy and exchange bias. The results reflect remarkable sensitivity of the out-of-plane magnetic torque to the nature of small edge domains perpendicular to the applied field direction, and also contain tantalizing indications of direct coupling to spin dynamics at the frequency of the mechanics.
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
Recent Advances in Mechanical Torque Studies of Small-scale Magnetism
Authors:
Joseph E. Losby,
Vincent T. K. Sauer,
Mark R. Freeman
Abstract:
There is a storied scientific history in the role of mechanical instruments for the measurement of fundamental physical interactions. Among these include the detection of magnetic torques via a displacement of a compliant mechanical sensor as a result of angular momentum transfer. Modern nanofabrication methods have enabled the coupling of mechanical structures to single, miniature magnetic specim…
▽ More
There is a storied scientific history in the role of mechanical instruments for the measurement of fundamental physical interactions. Among these include the detection of magnetic torques via a displacement of a compliant mechanical sensor as a result of angular momentum transfer. Modern nanofabrication methods have enabled the coupling of mechanical structures to single, miniature magnetic specimens. This has allowed for strikingly sensitive detection of magnetic hysteresis and other quasi-static effects, as well as spin resonances, in materials confined to nanoscale geometries. The extraordinary sensitivities achieved in mechanical transduction through recent breakthroughs in cavity optomechanics, where a high-finesse optical cavity is used for readout of motion, are now being harnessed for torque magnetometry. In this article, we review the recent progress in mechanical detection of magnetic torques, highlight current applications, and speculate on possible future developments in the technology and science. Guidelines for designing and implementing the measurements are also included.
△ Less
Submitted 16 June, 2018;
originally announced June 2018.
-
Improving mechanical sensor performance through larger dam**
Authors:
Swapan K. Roy,
Vincent T. K. Sauer,
Jocelyn N. Westwood-Bachman,
Anandram Venkatasubramanian,
Wayne K. Hiebert
Abstract:
Mechanical resonances are used in a wide variety of devices; from smart phone accelerometers to computer clocks and from wireless communication filters to atomic force microscope sensors. Frequency stability, a critical performance metric, is generally assumed to be tantamount to resonance quality factor (the inverse of the linewidth and of the dam**). Here we show that frequency stability of re…
▽ More
Mechanical resonances are used in a wide variety of devices; from smart phone accelerometers to computer clocks and from wireless communication filters to atomic force microscope sensors. Frequency stability, a critical performance metric, is generally assumed to be tantamount to resonance quality factor (the inverse of the linewidth and of the dam**). Here we show that frequency stability of resonant nanomechanical sensors can generally be made independent of quality factor. At high bandwidths, we show that quality factor reduction is completely mitigated by increases in signal to noise ratio. At low bandwidths, strikingly, increased dam** leads to better stability and sensor resolution, with improvement proportional to dam**. We confirm the findings by demonstrating temperature resolution of 50 μK at 200 Hz bandwidth. These results open the door for high performance ultrasensitive resonant sensors in gaseous or liquid environments, single cell nanocalorimetry, nanoscale gas chromatography, and atmospheric pressure nanoscale mass spectrometry.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.