-
Spin-3/2 nuclear magnetic resonance: Exact solutions for aligned systems and implications for probing Fe-based superconductors
Authors:
Jaafar N. Ansari,
Karen L. Sauer
Abstract:
The nuclear magnetic resonance (NMR) spectrum of spin-3/2 nuclei in a static magnetic field aligned with one of the electric field gradient (EFG) principal axes is developed analytically, based on fictitious spin-1/2 formalism. Compact closed-form expressions for the eigenstates and transitions frequencies, as well as the expectation value of the magnetic moment after resonant excitation, are deri…
▽ More
The nuclear magnetic resonance (NMR) spectrum of spin-3/2 nuclei in a static magnetic field aligned with one of the electric field gradient (EFG) principal axes is developed analytically, based on fictitious spin-1/2 formalism. Compact closed-form expressions for the eigenstates and transitions frequencies, as well as the expectation value of the magnetic moment after resonant excitation, are derived. Emphasis is placed on defining and interpreting the associated Rabi frequencies, as a function of excitation direction and ellipticity. It is found transitions inherently fall into two subsets, depending on their sensitivity to excitation direction, with the Rabi frequency of one subset directly depending on the asymmetry of the EFG. A natural application is the study of Fe-based superconductors, whose antiferromagnetic ordering at low temperatures leads to a strong intrinsic magnetic field aligned with the EFG principal axes. Zero external-field NMR spectra, from powder samples of two such Fe-based superconductors, BaFe$_2$As$_2$ and CaFe$_2$As$_2$, are analyzed and exemplify the simplicity in extracting the internal magnetic field, the quadrupole coupling constant, and the EFG asymmetry parameter, which are important for studying magnetic ordering, structural properties, phase transitions, and NMR dynamics. Results compare favorably to conventional high-field NMR experiments done with the rotation of single crystals. Overall, the physical insights, afforded by the exact and concise expressions, will lead to ready interpretation of spin-3/2 spectra as well as precipitate new experimental directions.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Photon distillation schemes with reduced resource costs based on multiphoton Fourier interference
Authors:
F. H. B. Somhorst,
B. K. Sauër,
S. N. van den Hoven,
J. J. Renema
Abstract:
Improving the indistinguishability of single photons is a crucial prerequisite for achieving large-scale photonic quantum computation. Photon distillation uses quantum interference to enhance the quality of single photons, sacrificing multiple photons to generate one photon with enhanced indistinguishability. By studying multiphoton interference in Fourier matrices, we find photon distillation sch…
▽ More
Improving the indistinguishability of single photons is a crucial prerequisite for achieving large-scale photonic quantum computation. Photon distillation uses quantum interference to enhance the quality of single photons, sacrificing multiple photons to generate one photon with enhanced indistinguishability. By studying multiphoton interference in Fourier matrices, we find photon distillation schemes that require fewer photons to achieve the same improvement in indistinguishability, compared to the state of the art. These results may find application as a component in large-scale photonic quantum computers.
△ Less
Submitted 3 May, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
On the origin of the type-III radiation observed near the Sun
Authors:
Forrest Mozer,
Oleksiy Agapitos,
Stuart Bale,
Keith Goetz,
Vladimir Krasnoselskikh,
Marc Pulupa,
Konrad Sauer,
Andrii Voshchepinets
Abstract:
$\textit{AIMS.}$ (1) To use Parker Solar Probe (PSP) data to test the accepted theory that type-III radiation is produced by counter-streaming Langmuir waves that coalesce to produce the electromagnetic wave at twice the Langmuir frequency. (2) To use the new data obtained from the PSP to improve or modify the model of type-III wave generation.
$\textit{METHODS.}…
▽ More
$\textit{AIMS.}$ (1) To use Parker Solar Probe (PSP) data to test the accepted theory that type-III radiation is produced by counter-streaming Langmuir waves that coalesce to produce the electromagnetic wave at twice the Langmuir frequency. (2) To use the new data obtained from the PSP to improve or modify the model of type-III wave generation.
$\textit{METHODS.}$ To obtain new properties of the Langmuir wave and its harmonics, their phase velocities and density fluctuations were measured. If the harmonic wave was electromagnetic, as in the accepted theory, these quantities would not be measurable. However, in an electrostatic wave, they would be measurable by the PSP instruments.
$\textit{RESULTS.}$ The Langmuir wave and its harmonics at frequencies of $nω_p$, where $ω_p = 2π\times125$ kHz is the Langmuir frequency and $n \in \{ 2, 3, 4, 5, 6, 7\}$, were measured in an active type-III event. The lowest harmonics contained density fluctuations, so they were electrostatic waves and not type-III emissions. This result was bolstered by measuring their very slow phase velocities ($< 20,000$ km/sec) which are not those of a type-III wave. Thus, the harmonic waves were not a result of the three-wave interaction (as required by the accepted theory) but they were electrostatic antenna waves produced by radiation of the Langmuir wave. As at least the first harmonic wave evolved through density irregularities, its wave number decreased and it became the electromagnetic wave that was the type-III radiation. It is also found that there is no evidence for or against the conventional model for generation of the type-III emissions.
△ Less
Submitted 14 June, 2024; v1 submitted 9 March, 2024;
originally announced March 2024.
-
Large-scale, Multi-pass, Two-chamber RF Atomic Magnetometer
Authors:
D. J. Heilman,
K. L. Sauer,
D. W. Prescott,
C. Z. Motamedi,
N. Dural,
M. V. Romalis,
T. W. Kornack
Abstract:
We describe one of the largest radio-frequency RF atomic magnetometers presently operating. A total atomic volume of 128 $\mathrm{cm^3}$, with correspondingly large number of $^{87}$Rb atoms, can reduce atom noise. A total of 44 passes of the probe beam reduces photon-shot noise. The atomic vapor is divided between two chambers allowing for pum** of the cells individually; doing so with opposite…
▽ More
We describe one of the largest radio-frequency RF atomic magnetometers presently operating. A total atomic volume of 128 $\mathrm{cm^3}$, with correspondingly large number of $^{87}$Rb atoms, can reduce atom noise. A total of 44 passes of the probe beam reduces photon-shot noise. The atomic vapor is divided between two chambers allowing for pum** of the cells individually; doing so with opposite-helicity light enables use as an intrinsic gradiometer. In this configuration, common-mode noise sources including light-shift noise can be reduced. Magnetic tuning fields can also be applied to the chambers individually, allowing simultaneous measurement of two frequencies. An application of this is in the search for contraband materials using Nuclear Quadrupole Resonance (NQR), for which simultaneous measurement can significantly reduce search times. We demonstrate dual-frequency measurement on an effective range of 423-531 kHz, corresponding to the NQR frequencies of ammonium nitrate NH$_4$NO$_3$ at the lowest value and potassium chlorate KClO$_3$ at the highest. We explore fundamental, as well as instrumental, noise contributions to the sensitivity in this system.
△ Less
Submitted 15 December, 2023;
originally announced December 2023.
-
Design of Novel Loss Functions for Deep Learning in X-ray CT
Authors:
Obaidullah Rahman,
Ken D. Sauer,
Madhuri Nagare,
Charles A. Bouman,
Roman Melnyk,
Jie Tang,
Brian Nett
Abstract:
Deep learning (DL) shows promise of advantages over conventional signal processing techniques in a variety of imaging applications. The networks' being trained from examples of data rather than explicitly designed allows them to learn signal and noise characteristics to most effectively construct a map** from corrupted data to higher quality representations. In inverse problems, one has options…
▽ More
Deep learning (DL) shows promise of advantages over conventional signal processing techniques in a variety of imaging applications. The networks' being trained from examples of data rather than explicitly designed allows them to learn signal and noise characteristics to most effectively construct a map** from corrupted data to higher quality representations. In inverse problems, one has options of applying DL in the domain of the originally captured data, in the transformed domain of the desired final representation, or both.
X-ray computed tomography (CT), one of the most valuable tools in medical diagnostics, is already being improved by DL methods. Whether for removal of common quantum noise resulting from the Poisson-distributed photon counts, or for reduction of the ill effects of metal implants on image quality, researchers have begun employing DL widely in CT. The selection of training data is driven quite directly by the corruption on which the focus lies. However, the way in which differences between the target signal and measured data is penalized in training generally follows conventional, pointwise loss functions.
This work introduces a creative technique for favoring reconstruction characteristics that are not well described by norms such as mean-squared or mean-absolute error. Particularly in a field such as X-ray CT, where radiologists' subjective preferences in image characteristics are key to acceptance, it may be desirable to penalize differences in DL more creatively. This penalty may be applied in the data domain, here the CT sinogram, or in the reconstructed image. We design loss functions for both sha** and selectively preserving frequency content of the signal.
△ Less
Submitted 23 September, 2023;
originally announced September 2023.
-
Statistically Adaptive Filtering for Low Signal Correction in X-ray Computed Tomography
Authors:
Obaidullah Rahman,
Ken D. Sauer,
Charles A. Bouman,
Roman Melnyk,
Brian Nett
Abstract:
Low x-ray dose is desirable in x-ray computed tomographic (CT) imaging due to health concerns. But low dose comes with a cost of low signal artifacts such as streaks and low frequency bias in the reconstruction. As a result, low signal correction is needed to help reduce artifacts while retaining relevant anatomical structures.
Low signal can be encountered in cases where sufficient number of ph…
▽ More
Low x-ray dose is desirable in x-ray computed tomographic (CT) imaging due to health concerns. But low dose comes with a cost of low signal artifacts such as streaks and low frequency bias in the reconstruction. As a result, low signal correction is needed to help reduce artifacts while retaining relevant anatomical structures.
Low signal can be encountered in cases where sufficient number of photons do not reach the detector to have confidence in the recorded data. % NOTE: SNR is ratio of powers, not std. dev. X-ray photons, assumed to have Poisson distribution, have signal to noise ratio proportional to the dose, with poorer SNR in low signal areas. Electronic noise added by the data acquisition system further reduces the signal quality.
In this paper we will demonstrate a technique to combat low signal artifacts through adaptive filtration. It entails statistics-based filtering on the uncorrected data, correcting the lower signal areas more aggressively than the high signal ones. We look at local averages to decide how aggressive the filtering should be, and local standard deviation to decide how much detail preservation to apply. Implementation consists of a pre-correction step i.e. local linear minimum mean-squared error correction, followed by a variance stabilizing transform, and finally adaptive bilateral filtering. The coefficients of the bilateral filter are computed using local statistics. Results show that improvements were made in terms of low frequency bias, streaks, local average and standard deviation, modulation transfer function and noise power spectrum.
△ Less
Submitted 23 September, 2023;
originally announced September 2023.
-
MBIR Training for a 2.5D DL network in X-ray CT
Authors:
Obaidullah Rahman,
Madhuri Nagare,
Ken D. Sauer,
Charles A. Bouman,
Roman Melnyk,
Brian Nett,
Jie Tang
Abstract:
In computed tomographic imaging, model based iterative reconstruction methods have generally shown better image quality than the more traditional, faster filtered backprojection technique. The cost we have to pay is that MBIR is computationally expensive. In this work we train a 2.5D deep learning (DL) network to mimic MBIR quality image. The network is realized by a modified Unet, and trained usi…
▽ More
In computed tomographic imaging, model based iterative reconstruction methods have generally shown better image quality than the more traditional, faster filtered backprojection technique. The cost we have to pay is that MBIR is computationally expensive. In this work we train a 2.5D deep learning (DL) network to mimic MBIR quality image. The network is realized by a modified Unet, and trained using clinical FBP and MBIR image pairs. We achieve the quality of MBIR images faster and with a much smaller computation cost. Visually and in terms of noise power spectrum (NPS), DL-MBIR images have texture similar to that of MBIR, with reduced noise power. Image profile plots, NPS plots, standard deviation, etc. suggest that the DL-MBIR images result from a successful emulation of an MBIR operator.
△ Less
Submitted 23 September, 2023;
originally announced September 2023.
-
Direct Iterative Reconstruction of Multiple Basis Material Images in Photon-counting Spectral CT
Authors:
Obaidullah Rahman,
Ken Sauer,
Connor Evans,
Ryan Roeder
Abstract:
In this work, we perform direct material reconstruction from spectral CT data using a model based iterative reconstruction (MBIR) approach. Material concentrations are measured in volume fractions, whose total is constrained by a maximum of unity. A phantom containing a combination of 4 basis materials (water, iodine, gadolinium, calcium) was scanned using a photon-counting detector. Iodine and ga…
▽ More
In this work, we perform direct material reconstruction from spectral CT data using a model based iterative reconstruction (MBIR) approach. Material concentrations are measured in volume fractions, whose total is constrained by a maximum of unity. A phantom containing a combination of 4 basis materials (water, iodine, gadolinium, calcium) was scanned using a photon-counting detector. Iodine and gadolinium were chosen because of their common use as contrast agents in CT imaging. Scan data was binned into 5 energy (keV) levels. Each energy bin in a calibration scan was reconstructed, allowing the linear attenuation coefficient of each material for every energy to be estimated by a least-squares fit to ground truth in the image domain. The resulting $5\times 4$ matrix, for $5$ energies and $4$ materials, is incorporated into the forward model in direct reconstruction of the $4$ basis material images with spatial and/or inter-material regularization. In reconstruction from a subsequent low-concentration scan, volume fractions within regions of interest (ROIs) are found to be close to the ground truth. This work is meant to lay the foundation for further work with phantoms including spatially coincident mixtures of contrast materials and/or contrast agents in widely varying concentrations, molecular imaging from animal scans, and eventually clinical applications.
△ Less
Submitted 28 September, 2023; v1 submitted 23 September, 2023;
originally announced September 2023.
-
Magnetic Jones Vector Detection with RF Atomic Magnetometers
Authors:
Cicely Motamedi,
Karen Sauer
Abstract:
We show, theoretically and experimentally, how the absolute orientation and polarization state of radio-frequency (RF) magnetic fields in a transverse 2D plane can be uniquely determined using two optically pumped atomic magnetometers. In addition, the output signals from these quantum sensors can be readily expressed as a magnetic Jones vector. This composite device can complement electric field…
▽ More
We show, theoretically and experimentally, how the absolute orientation and polarization state of radio-frequency (RF) magnetic fields in a transverse 2D plane can be uniquely determined using two optically pumped atomic magnetometers. In addition, the output signals from these quantum sensors can be readily expressed as a magnetic Jones vector. This composite device can complement electric field detection in finding RF directions, or it can be used in applications where the electric field is negligible. The latter is found in a myriad of applications where the source can be modeled as radiating magnetic dipoles in the near-field limit. This new tool could be used to characterize a material's response to RF excitation or to distinguish signal from noise.
△ Less
Submitted 6 June, 2023; v1 submitted 30 March, 2023;
originally announced March 2023.
-
Density Enhancement Streams in The Solar Wind
Authors:
F. S. Mozer,
O. Agapitov,
S. D. Bale,
R. Livi,
O. Romeo,
K. Sauer,
I. Y. Vasko,
J. Verniero
Abstract:
This letter describes a new phenomenon on the Parker Solar Probe of recurring plasma density enhancements that have $Δ$n/n ~10% and that occur at a repetition rate of ~5 Hz. They were observed sporadically for about five hours between 14 and 15 solar radii on Parker Solar Probe orbit 12 and they were also seen in the same radial range on both the inbound and outbound orbits 11. Their apparently st…
▽ More
This letter describes a new phenomenon on the Parker Solar Probe of recurring plasma density enhancements that have $Δ$n/n ~10% and that occur at a repetition rate of ~5 Hz. They were observed sporadically for about five hours between 14 and 15 solar radii on Parker Solar Probe orbit 12 and they were also seen in the same radial range on both the inbound and outbound orbits 11. Their apparently steady-state existence suggests that their pressure gradient was balanced by the electric field. The EX electric field component produced from this requirement is in good agreement with that measured. This provides strong evidence for the measurement accuracy of the density fluctuations and the X- and Y-components of the electric field (the Z-component was not measured). The electrostatic density waves were accompanied by an electromagnetic low frequency wave which occurred with the electrostatic harmonics. The amplitudes of these electrostatic and electromagnetic waves at $\ge$ 1 Hz were greater than the amplitude of the Alfvenic turbulence in their vicinity so they can be important for the heating, scattering, and acceleration of the plasma. The existence of this pair of waves is consistent with the observed plasma distributions and is explained by a magneto-acoustic wave theory that produces a low frequency electromagnetic wave and electrostatic harmonics.
△ Less
Submitted 29 July, 2023; v1 submitted 17 February, 2023;
originally announced February 2023.
-
Three-axis torque investigation of interfacial exchange coupling in a NiFe/CoO bilayer micromagnetic disk
Authors:
M. G. Dunsmore,
J. A. Thibault,
K. R. Fast,
V. T. K. Sauer,
J. E. Losby,
Z. Diao,
M. Belov,
M. R. Freeman
Abstract:
Micrometer diameter bilayers of NiFe (permalloy, Py) and cobalt oxide (CoO) deposited on nanomechanical resonators were used to investigate exchange bias effects. The mechanical compliances of two resonator axes were enhanced by severing one torsion arm, resulting in a unique three-axis resonator that responds resonantly to torques generated by a three-axis RF field. Our technique permits simultan…
▽ More
Micrometer diameter bilayers of NiFe (permalloy, Py) and cobalt oxide (CoO) deposited on nanomechanical resonators were used to investigate exchange bias effects. The mechanical compliances of two resonator axes were enhanced by severing one torsion arm, resulting in a unique three-axis resonator that responds resonantly to torques generated by a three-axis RF field. Our technique permits simultaneous measurement of three orthogonal torque components. Measurements of the anisotropies associated with interfacial exchange coupling effects have been made. At cryogenic temperatures, observations of shifted linear hysteresis loops confirmed the presence of exchange bias from the Py/CoO interface. An in-plane rotating DC bias field was used to probe in-plane anisotropies through the out-of-plane torque. Training effects in the rotational hysteresis data were observed and showed that features due to interfacial coupling did not diminish irrespective of substantial training of the unidirectional anisotropy. The data from the rotational hysteresis loops were fit with parameters from a macrospin solution to the Landau-Lifshitz-Gilbert equation. Each parameter of the exchange bias model accounts for specific features of the rotational loop.
△ Less
Submitted 4 February, 2022;
originally announced February 2022.
-
Simultaneous three-axis torque measurements of micromagnetism
Authors:
K. R. Fast,
J. A. Thibault,
V. T. K. Sauer,
M. G. Dunsmore,
A. Kav,
J. E. Losby,
Z. Diao,
E. J. Luber,
M. Belov,
M. R. Freeman
Abstract:
Measurements of magnetic torque are most commonly preformed about a single axis or component of torque. Such measurements are very useful for hysteresis measurements of thin film structures in particular, where high shape anisotropy yields a near-proportionality of in-plane magnetic moment and the magnetic torque along the perpendicular in-plane axis. A technique to measure the full magnetic torqu…
▽ More
Measurements of magnetic torque are most commonly preformed about a single axis or component of torque. Such measurements are very useful for hysteresis measurements of thin film structures in particular, where high shape anisotropy yields a near-proportionality of in-plane magnetic moment and the magnetic torque along the perpendicular in-plane axis. A technique to measure the full magnetic torque vector (three orthogonal torque components) on micro- and nano-scale magnetic materials is introduced. The method is demonstrated using a modified, single-paddle silicon-on-insulator resonant torque sensor. The mechanical compliances to all three orthogonal torque components are maximized by clam** the sensor at a single point. Mechanically-resonant AC torques are driven by an RF field containing a frequency component for each fundamental torsional mode of the device, and the resulting displacements read out through optical position-sensitive detection. The measurements are compared with micromagnetic simulations of the mechanical torque to augment the interpretation of the signals. As an application example, simultaneous observations of hysteresis in the net magnetization along with the field-dependent in-plane anisotropy is highly beneficial for studies of exchange bias.
△ Less
Submitted 2 November, 2020;
originally announced November 2020.
-
Density Functional Theory based Electric Field Gradient Database
Authors:
Kamal Choudhary,
Jaafar N. Ansari,
Igor I. Mazin,
Karen L. Sauer
Abstract:
The deviation of the electron density around the nuclei from spherical symmetry determines the electric field gradient (EFG), which can be measured by various types of spectroscopy. Nuclear Quadrupole Resonance (NQR) is particularly sensitive to the EFG. The EFGs, and by implication NQR frequencies, vary dramatically across materials. Consequently, searching for NQR spectral lines in previously un…
▽ More
The deviation of the electron density around the nuclei from spherical symmetry determines the electric field gradient (EFG), which can be measured by various types of spectroscopy. Nuclear Quadrupole Resonance (NQR) is particularly sensitive to the EFG. The EFGs, and by implication NQR frequencies, vary dramatically across materials. Consequently, searching for NQR spectral lines in previously uninvestigated materials represents a major challenge. Calculated EFGs can significantly aid at the search inception. To facilitate this task, we have applied high-throughput density functional theory calculations to predict EFGs for 15187 materials in the JARVIS-DFT database. This database, which will include EFG as a standard entry, is continuously increasing. Given the large scope of the database, it is impractical to verify each calculation. However, we assess accuracy by singling out cases for which reliable experimental information is readily available and compare them to the calculations. We further present a statistical analysis of the results. The database and tools associated with our work are made publicly available by JARVIS-DFT ( https://www.ctcms.nist.gov/~knc6/JVASP.html ) and NIST-JARVIS API ( http://jarvis.nist.gov ).
△ Less
Submitted 19 May, 2020;
originally announced May 2020.
-
Two-axis cavity optomechanical torque characterization of magnetic microstructures
Authors:
Ghazal Hajisalem,
Joseph E. Losby,
Gustavo de Oliveira Luiz,
Vincent T. K. Sauer,
Paul E. Barclay,
Mark R. Freeman
Abstract:
Significant new functionality is reported for torsion mechanical tools aimed at full magnetic characterizations of both spin statics and dynamics in micro- and nanostructures. Specifically, two orthogonal torque directions are monitored and the results co-analyzed to separate magnetic moment and magnetic susceptibility contributions to torque, as is desired for characterization of anisotropic thre…
▽ More
Significant new functionality is reported for torsion mechanical tools aimed at full magnetic characterizations of both spin statics and dynamics in micro- and nanostructures. Specifically, two orthogonal torque directions are monitored and the results co-analyzed to separate magnetic moment and magnetic susceptibility contributions to torque, as is desired for characterization of anisotropic three-dimensional structures. The approach is demonstrated through application to shape and microstructural disorder-induced magnetic anisotropies in lithographically patterned permalloy, and will have utility for the determination of important magnetic thin-film and multilayer properties including interface anisotropy and exchange bias. The results reflect remarkable sensitivity of the out-of-plane magnetic torque to the nature of small edge domains perpendicular to the applied field direction, and also contain tantalizing indications of direct coupling to spin dynamics at the frequency of the mechanics.
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
2.5D Deep Learning for CT Image Reconstruction using a Multi-GPU implementation
Authors:
Amirkoushyar Ziabari,
Dong Hye Ye,
Somesh Srivastava,
Ken D. Sauer,
Jean-Baptiste Thibault,
Charles A. Bouman
Abstract:
While Model Based Iterative Reconstruction (MBIR) of CT scans has been shown to have better image quality than Filtered Back Projection (FBP), its use has been limited by its high computational cost. More recently, deep convolutional neural networks (CNN) have shown great promise in both denoising and reconstruction applications. In this research, we propose a fast reconstruction algorithm, which…
▽ More
While Model Based Iterative Reconstruction (MBIR) of CT scans has been shown to have better image quality than Filtered Back Projection (FBP), its use has been limited by its high computational cost. More recently, deep convolutional neural networks (CNN) have shown great promise in both denoising and reconstruction applications. In this research, we propose a fast reconstruction algorithm, which we call Deep Learning MBIR (DL-MBIR), for approximating MBIR using a deep residual neural network. The DL-MBIR method is trained to produce reconstructions that approximate true MBIR images using a 16 layer residual convolutional neural network implemented on multiple GPUs using Google Tensorflow. In addition, we propose 2D, 2.5D and 3D variations on the DL-MBIR method and show that the 2.5D method achieves similar quality to the fully 3D method, but with reduced computational cost.
△ Less
Submitted 20 December, 2018;
originally announced December 2018.
-
Model Based Iterative Reconstruction With Spatially Adaptive Sinogram Weights for Wide-Cone Cardiac CT
Authors:
Amirkoushyar Ziabari,
Dong Hye Ye,
Lin Fu,
Somesh Srivastava,
Ken D. Sauer,
Jean-Baptist Thibault,
Charles A. Bouman
Abstract:
With the recent introduction of CT scanners with large cone angles, wide coverage detectors now provide a desirable scanning platform for cardiac CT that allows whole heart imaging in a single rotation. On these scanners, while half-scan data is strictly sufficient to produce images with the best temporal resolution, acquiring a full 360 degree rotation worth of data is beneficial for wide-cone im…
▽ More
With the recent introduction of CT scanners with large cone angles, wide coverage detectors now provide a desirable scanning platform for cardiac CT that allows whole heart imaging in a single rotation. On these scanners, while half-scan data is strictly sufficient to produce images with the best temporal resolution, acquiring a full 360 degree rotation worth of data is beneficial for wide-cone image reconstruction at negligible additional radiation dose. Applying Model-Based Iterative Reconstruction (MBIR) algorithm to the heart has shown to yield significant enhancement in image quality for cardiac CT. But imaging the heart in large cone angle geometry leads to apparently conflicting data usage considerations. On the one hand, in addition to using the fastest available scanner rotation speed, a minimal complete data set of 180 degrees plus the fan angle is typically used to minimize both cardiac and respiratory motion. On the other hand, a full 360 degree acquisition helps better handle the challenges of missing frequencies and incomplete projections associated with wide-cone half-scan data acquisition. In this paper, we develop a Spatially Adaptive sinogram Weights MBIR algorithm (SAW-MBIR) that is designed to achieve the benefits of both half and full-scan reconstructions in order to maximize temporal resolution over the heart region while providing stable results over the whole volume covered with the wide-area detector. Spatially-adaptive sinogram weights applied to each projection measurement in SAW-MBIR are designed to selectively perform backprojection from the full and half-scan portion of the sinogram based on both projection angle and reconstructed voxel location. We demonstrate with experimental results of SAW-MBIR applied to whole-heart cardiac CT clinical data that overall temporal resolution matches half-scan while full volume image quality is on par with full-scan MBIR.
△ Less
Submitted 20 December, 2018;
originally announced December 2018.
-
Recent Advances in Mechanical Torque Studies of Small-scale Magnetism
Authors:
Joseph E. Losby,
Vincent T. K. Sauer,
Mark R. Freeman
Abstract:
There is a storied scientific history in the role of mechanical instruments for the measurement of fundamental physical interactions. Among these include the detection of magnetic torques via a displacement of a compliant mechanical sensor as a result of angular momentum transfer. Modern nanofabrication methods have enabled the coupling of mechanical structures to single, miniature magnetic specim…
▽ More
There is a storied scientific history in the role of mechanical instruments for the measurement of fundamental physical interactions. Among these include the detection of magnetic torques via a displacement of a compliant mechanical sensor as a result of angular momentum transfer. Modern nanofabrication methods have enabled the coupling of mechanical structures to single, miniature magnetic specimens. This has allowed for strikingly sensitive detection of magnetic hysteresis and other quasi-static effects, as well as spin resonances, in materials confined to nanoscale geometries. The extraordinary sensitivities achieved in mechanical transduction through recent breakthroughs in cavity optomechanics, where a high-finesse optical cavity is used for readout of motion, are now being harnessed for torque magnetometry. In this article, we review the recent progress in mechanical detection of magnetic torques, highlight current applications, and speculate on possible future developments in the technology and science. Guidelines for designing and implementing the measurements are also included.
△ Less
Submitted 16 June, 2018;
originally announced June 2018.
-
Improving mechanical sensor performance through larger dam**
Authors:
Swapan K. Roy,
Vincent T. K. Sauer,
Jocelyn N. Westwood-Bachman,
Anandram Venkatasubramanian,
Wayne K. Hiebert
Abstract:
Mechanical resonances are used in a wide variety of devices; from smart phone accelerometers to computer clocks and from wireless communication filters to atomic force microscope sensors. Frequency stability, a critical performance metric, is generally assumed to be tantamount to resonance quality factor (the inverse of the linewidth and of the dam**). Here we show that frequency stability of re…
▽ More
Mechanical resonances are used in a wide variety of devices; from smart phone accelerometers to computer clocks and from wireless communication filters to atomic force microscope sensors. Frequency stability, a critical performance metric, is generally assumed to be tantamount to resonance quality factor (the inverse of the linewidth and of the dam**). Here we show that frequency stability of resonant nanomechanical sensors can generally be made independent of quality factor. At high bandwidths, we show that quality factor reduction is completely mitigated by increases in signal to noise ratio. At low bandwidths, strikingly, increased dam** leads to better stability and sensor resolution, with improvement proportional to dam**. We confirm the findings by demonstrating temperature resolution of 50 μK at 200 Hz bandwidth. These results open the door for high performance ultrasensitive resonant sensors in gaseous or liquid environments, single cell nanocalorimetry, nanoscale gas chromatography, and atmospheric pressure nanoscale mass spectrometry.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.
-
A Gaussian Mixture MRF for Model-Based Iterative Reconstruction with Applications to Low-Dose X-ray CT
Authors:
Ruoqiao Zhang,
Dong Hye Ye,
Debashish Pal,
Jean-Baptiste Thibault,
Ken D. Sauer,
Charles A. Bouman
Abstract:
Markov random fields (MRFs) have been widely used as prior models in various inverse problems such as tomographic reconstruction. While MRFs provide a simple and often effective way to model the spatial dependencies in images, they suffer from the fact that parameter estimation is difficult. In practice, this means that MRFs typically have very simple structure that cannot completely capture the s…
▽ More
Markov random fields (MRFs) have been widely used as prior models in various inverse problems such as tomographic reconstruction. While MRFs provide a simple and often effective way to model the spatial dependencies in images, they suffer from the fact that parameter estimation is difficult. In practice, this means that MRFs typically have very simple structure that cannot completely capture the subtle characteristics of complex images.
In this paper, we present a novel Gaussian mixture Markov random field model (GM-MRF) that can be used as a very expressive prior model for inverse problems such as denoising and reconstruction. The GM-MRF forms a global image model by merging together individual Gaussian-mixture models (GMMs) for image patches. In addition, we present a novel analytical framework for computing MAP estimates using the GM-MRF prior model through the construction of surrogate functions that result in a sequence of quadratic optimizations. We also introduce a simple but effective method to adjust the GM-MRF so as to control the sharpness in low- and high-contrast regions of the reconstruction separately. We demonstrate the value of the model with experiments including image denoising and low-dose CT reconstruction.
△ Less
Submitted 13 June, 2016; v1 submitted 12 May, 2016;
originally announced May 2016.
-
In silico Modeling of Itk Activation Kinetics in Thymocytes Suggests Competing Positive and Negative IP4 Mediated Feedbacks Increase Robustness
Authors:
Sayak Mukherjee,
Stephanie Rigaud,
Sang-Cheol Seok,
Guo Fu,
Agnieszka Prochenka,
Michael Dworkin,
Nicholas R. J. Gascoigne,
Veronica J. Vieland,
Karsten Sauer,
Jayajit Das
Abstract:
The inositol-phosphate messenger inositol(1,3,4,5)tetrakisphosphate (IP4) is essential for thymocyte positive selection by regulating plasma-membrane association of the protein tyrosine kinase Itk downstream of the T cell receptor (TCR). IP4 can act as a soluble analog of the phosphoinositide 3-kinase (PI3K) membrane lipid product phosphatidylinositol(3,4,5)trisphosphate (PIP3). PIP3 recruits sign…
▽ More
The inositol-phosphate messenger inositol(1,3,4,5)tetrakisphosphate (IP4) is essential for thymocyte positive selection by regulating plasma-membrane association of the protein tyrosine kinase Itk downstream of the T cell receptor (TCR). IP4 can act as a soluble analog of the phosphoinositide 3-kinase (PI3K) membrane lipid product phosphatidylinositol(3,4,5)trisphosphate (PIP3). PIP3 recruits signaling proteins such as Itk to cellular membranes by binding to PH and other domains. In thymocytes, low-dose IP4 binding to the Itk PH domain surprisingly promoted and high-dose IP4 inhibited PIP3 binding of Itk PH domains. However, the mechanisms that underlie the regulation of membrane recruitment of Itk by IP4 and PIP3 remain unclear. The distinct Itk PH domain ability to oligomerize is consistent with a cooperative-allosteric mode of IP4 action. However, other possibilities cannot be ruled out due to difficulties in quantitatively measuring the interactions between Itk, IP4 and PIP3, and in generating non-oligomerizing Itk PH domain mutants. This has hindered a full mechanistic understanding of how IP4 controls Itk function. By combining experimentally measured kinetics of PLCγ1 phosphorylation by Itk with in silico modeling of multiple Itk signaling circuits and a maximum entropy (MaxEnt) based computational approach, we show that those in silico models which are most robust against variations of protein and lipid expression levels and kinetic rates at the single cell level share a cooperative-allosteric mode of Itk regulation by IP4 involving oligomeric Itk PH domains at the plasma membrane. This identifies MaxEnt as an excellent tool for quantifying robustness for complex TCR signaling circuits and provides testable predictions to further elucidate a controversial mechanism of PIP3 signaling.
△ Less
Submitted 26 July, 2013;
originally announced July 2013.
-
Parallel BioScape: A Stochastic and Parallel Language for Mobile and Spatial Interactions
Authors:
Adriana Compagnoni,
Mariangiola Dezani-Ciancaglini,
Paola Giannini,
Karin Sauer,
Vishakha Sharma,
Angelo Troina
Abstract:
BioScape is a concurrent language motivated by the biological landscapes found at the interface of biology and biomaterials. It has been motivated by the need to model antibacterial surfaces, biofilm formation, and the effect of DNAse in treating and preventing biofilm infections. As its predecessor, SPiM, BioScape has a sequential semantics based on Gillespie's algorithm, and its implementation d…
▽ More
BioScape is a concurrent language motivated by the biological landscapes found at the interface of biology and biomaterials. It has been motivated by the need to model antibacterial surfaces, biofilm formation, and the effect of DNAse in treating and preventing biofilm infections. As its predecessor, SPiM, BioScape has a sequential semantics based on Gillespie's algorithm, and its implementation does not scale beyond 1000 agents. However, in order to model larger and more realistic systems, a semantics that may take advantage of the new multi-core and GPU architectures is needed. This motivates the introduction of parallel semantics, which is the contribution of this paper: Parallel BioScape, an extension with fully parallel semantics.
△ Less
Submitted 17 November, 2012;
originally announced November 2012.
-
Spin Dam** in an RF Atomic Magnetometer
Authors:
Orang Alem,
Karen L. Sauer,
Mike V. Romalis
Abstract:
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin-dam**, with a characteristic spectral response corresponding…
▽ More
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin-dam**, with a characteristic spectral response corresponding to the type of noise; therefore magnetic, photon-shot, and spin-projection noise can be measured distinctly. While the suppression of resonant photon-shot noise implies the closed-loop production of polarization-squeezed light, the suppression of resonant spin-projection noise does not imply spin-squeezing, rather simply the broadening of the noise spectrum with Q. Furthermore, the application of spin-dam** during phase-sensitive detection suppresses both signal and noise in such a way as to increase the sensitivity bandwidth. We demonstrate a three-fold increase in the magnetometer's bandwidth while maintaining 0.3 fT/\surdHz sensitivity.
△ Less
Submitted 12 July, 2012;
originally announced July 2012.
-
Shape reconstruction in X-ray tomography from a small number of projections using deformable models
Authors:
A. Mohammad-Djafari,
Ken Sauer
Abstract:
X-ray tomographic image reconstruction consists of determining an object function from its projections. In many applications such as non-destructive testing, we look for a fault region (air) in a homogeneous, known background (metal). The image reconstruction problem then becomes the determination of the shape of the default region. Two approaches can be used: modeling the image as a binary Mark…
▽ More
X-ray tomographic image reconstruction consists of determining an object function from its projections. In many applications such as non-destructive testing, we look for a fault region (air) in a homogeneous, known background (metal). The image reconstruction problem then becomes the determination of the shape of the default region. Two approaches can be used: modeling the image as a binary Markov random field and estimating the pixels of the image, or modeling the shape of the fault and estimating it directly from the projections. In this work we model the fault shape by a deformable polygonal disc or a deformable polyhedral volume and propose a new method for directly estimating the coordinates of its vertices from a very limited number of its projections. The basic idea is not new, but in other competing methods, in general, the fault shape is modeled by a small number of parameters (polygonal shapes with very small number of vertices, snakes and deformable templates) and these parameters are estimated either by least squares or by maximum likelihood methods. We propose modeling the shape of the fault region by a polygon with a large number of vertices, allowing modeling of nearly any shape and estimation of its vertices' coordinates directly from the projections by defining the solution as the minimizer of an appropriate regularized criterion. This formulation can also be interpreted as a maximum a posteriori (MAP) estimate in a Bayesian estimation framework. To optimize this criterion we use either a simulated annealing or a special purpose deterministic algorithm based on iterated conditional modes (ICM). The simulated results are very encouraging, especially when the number and the angles of projections are very limited.
△ Less
Submitted 14 November, 2001;
originally announced November 2001.