-
Non-destructive inelastic recoil spectroscopy of a single molecular ion: a versatile tool toward precision action spectroscopy
Authors:
Aaron Calvin,
Scott Eierman,
Zeyun Peng,
Merrell Brzeczek,
Samuel Kresch,
Elijah Lane,
Lincoln Satterthwaite,
David Patterson
Abstract:
We demonstrate a novel single molecule technique that is compatible with high precision measurements and obtain the spectrum of two molecular ion species. While the current result yields modest spectral resolution due to a broad light source, we expect the method to ultimately provide resolution comparable to quantum logic methods with significantly less stringent requirements. Adaptations of this…
▽ More
We demonstrate a novel single molecule technique that is compatible with high precision measurements and obtain the spectrum of two molecular ion species. While the current result yields modest spectral resolution due to a broad light source, we expect the method to ultimately provide resolution comparable to quantum logic methods with significantly less stringent requirements. Adaptations of this technique will prove useful in a wide range of precision spectroscopy arenas including the search for parity violating effects in chiral molecules.
△ Less
Submitted 22 July, 2023;
originally announced July 2023.
-
High Sensitivity Microwave Spectroscopy in a Cryogenic Buffer Gas Cell
Authors:
Jessica P. Porterfield,
Lincoln Satterthwaite,
Sandra Eibenberger,
David Patterson,
Michael C. McCarthy
Abstract:
We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected using chirped pulse microwave spectroscopy. Here we demonstrate three significant improvements to the apparatus relative to an earlier version: (1) extension of its…
▽ More
We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected using chirped pulse microwave spectroscopy. Here we demonstrate three significant improvements to the apparatus relative to an earlier version: (1) extension of its operating range by more than a factor of two, from 12-18 GHz to 12-26 GHz, which allows a much wider range of species to be characterized; (2) improved detection sensitivity owing to use of cryogenically-cooled low-noise amplifiers and protection switches, and (3) a versatile method of sample input that enables analysis of solids, liquids, gases, and solutions, without the need for chemical separation (as demonstrated with a 12-16 GHz spectrum of lemon oil). This instrument can record broadband microwave spectra at comparable sensitivity to high Q cavity spectrometers which use pulsed supersonic jets, but up to 3000 times faster with a modest increase in sample consumption rate.
△ Less
Submitted 15 February, 2019;
originally announced February 2019.
-
Automated, context-free assignment of asymmetric rotor microwave spectra
Authors:
Lia Yeh,
Lincoln Satterthwaite,
David Patterson
Abstract:
We present a new algorithm, Robust Automated Assignment of Rigid Rotors (RAARR), for assigning rotational spectra of asymmetric tops. The RAARR algorithm can automatically assign experimental spectra under a broad range of conditions, including spectra comprised of multiple mixture components, in about 100 seconds or less. The RAARR algorithm exploits constraints placed by the conservation of ener…
▽ More
We present a new algorithm, Robust Automated Assignment of Rigid Rotors (RAARR), for assigning rotational spectra of asymmetric tops. The RAARR algorithm can automatically assign experimental spectra under a broad range of conditions, including spectra comprised of multiple mixture components, in about 100 seconds or less. The RAARR algorithm exploits constraints placed by the conservation of energy to find sets of connected lines in an unassigned spectrum. The highly constrained structure of these sets eliminates all but a handful of plausible assignments for a given set, greatly reducing the number of potential assignments that must be evaluated. We successfully apply our algorithm to automatically assign 15 experimental spectra, including 5 previously unassigned species, without prior estimation of molecular rotational constants. In 9 of the 15 cases, the RAARR algorithm successfully assigns two or more mixture components.
△ Less
Submitted 16 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.