-
Transmission ERDA of ubiquitous deuterium in H-containing materials
Authors:
Hiroshi Kudo,
Hiroshi Naramoto,
Masao Sataka,
Satoshi Ishii,
Kimikazu Sasa,
Shigeo Tomita
Abstract:
Transmission-type elastic recoil detection analysis (T-ERDA) using 8.02 MeV He has been successfully applied to determine the concentration of ubiquitous deuterium in mylar and PPS films, both containing hydrogen as a component. The determined D/H ratios of $(1.60\pm 0.08) \times 10^{-4}$ and $(1.23\pm 0.08) \times 10^{-4}$ for mylar and PPS, respectively, are only slightly deviated from the Stand…
▽ More
Transmission-type elastic recoil detection analysis (T-ERDA) using 8.02 MeV He has been successfully applied to determine the concentration of ubiquitous deuterium in mylar and PPS films, both containing hydrogen as a component. The determined D/H ratios of $(1.60\pm 0.08) \times 10^{-4}$ and $(1.23\pm 0.08) \times 10^{-4}$ for mylar and PPS, respectively, are only slightly deviated from the Standard Mean Ocean Water value of $1.55\cdots \times 10^{-4}$. These results indicate potential sensitivity of T-ERDA for analysis of the variation of ubiquitous deuterium in hydrogen-containing materials. Such deuterium analysis might be useful for unique characterization of not only natural, but also synthesized hydrogen-containing materials.
△ Less
Submitted 4 October, 2023; v1 submitted 3 April, 2023;
originally announced April 2023.
-
Determination of hydrogen concentration in solids by transmission ERDA under nuclear-elastically enhanced recoiling of H by 8 and 9 MeV He
Authors:
Hiroshi Kudo,
Masanori Kurosawa,
Hiroshi Naramoto,
Masao Sataka,
Satoshi Ishii,
Kimikazu Sasa,
Shigeo Tomita
Abstract:
Hydrogen concentrations in thin self-supporting samples of polyphenylene sulfide and muscovite have been determined by nuclear-elastic recoil detection analysis of transmission layout. The analysis procedure is based only on the database of stop** power and recoil cross section for material analysis, without using any reference sample of known H content. For the polyphenylene sulfide sample, the…
▽ More
Hydrogen concentrations in thin self-supporting samples of polyphenylene sulfide and muscovite have been determined by nuclear-elastic recoil detection analysis of transmission layout. The analysis procedure is based only on the database of stop** power and recoil cross section for material analysis, without using any reference sample of known H content. For the polyphenylene sulfide sample, the determined value of $(2.87\pm 0.26)\times 10^{22}\,{\rm H}/$cm$^{3}$ is in good agreement with the calculated value of $3.01 \times 10^{22}\,{\rm H}/$cm$^{3}$. For the muscovite sample, the H concentration originating each from bound water and absorbed water is uniform over the entire thickness of the sample. The determined concentration $(9.43 \pm 0.75) \times 10^{21}$ H$/$cm$^{3}$ of the muscovite agrees excellently with the value of $9.36 \times 10^{21}$ H$/$cm$^{3}$ obtained from other quantitative analyses typically applied for minerals. The present results demonstrate the capability of accurate determination of H contents in materials and minerals by transmission ERDA.
△ Less
Submitted 24 August, 2022; v1 submitted 6 June, 2022;
originally announced June 2022.
-
Depth resolution of transmission ERDA for H in Al under nuclear-elastically enhanced recoiling of H by 8 MeV He
Authors:
H. Kudo,
H. Naramoto,
M. Sataka,
S. Ishii,
K. Sasa S. Tomita
Abstract:
This manuscript describes our experimental work being carried out to develop the previously published T-ERDA technique to measure H distribution in solids [Yamazaki et al., AIP Adv. 9 (2019) 105111]. From the experiments for the samples with H markers, we have identified the factors that degrade the depth resolution for analysis of H distribution, depending on the acceptance conditions of the dete…
▽ More
This manuscript describes our experimental work being carried out to develop the previously published T-ERDA technique to measure H distribution in solids [Yamazaki et al., AIP Adv. 9 (2019) 105111]. From the experiments for the samples with H markers, we have identified the factors that degrade the depth resolution for analysis of H distribution, depending on the acceptance conditions of the detector.
△ Less
Submitted 24 March, 2021;
originally announced March 2021.