Neutron detectors for the ESS diffractometers
Authors:
I. Stefanescu,
M. Christensen,
J. Fenske,
R. Hall-Wilton,
P. F. Henry,
O. Kirstein,
M. Mueller,
G. Nowak,
D. Pooley,
D. Raspino,
N. Rhodes,
J. Saroun,
J. Schefer,
E. Schooneveld,
J. Sykora,
W. Schweika
Abstract:
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting r…
▽ More
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting rates, while the investigation of sub-millimeter protein crystals will only be possible with large-area detectors that can achieve a position resolution as low as 200 μm. This has motivated an extensive research and development campaign to advance the state-of-the-art detector and to find new technologies that can reach maturity by the time the ESS will operate at full potential. This paper presents the key detector requirements for three of the Time-of-Flight diffraction instrument concepts selected by the Scientific Advisory Committee to advance into the phase of preliminary engineering design. We discuss the available detector technologies suitable for this particular instrument class and their major challenges. The detector technologies selected by the instrument teams to collect the diffraction patterns are briefly discussed. Analytical calculations, Monte-Carlo simulations, and real experimental data are used to develop a generic method to esti- mate the event rate in the diffraction detectors. The proposed approach is based upon conservative assumptions that use information and input parameters that reflect our current level of knowledge and understanding of the ESS project. We apply this method to make predictions for the future diffraction instruments, and thus provide additional information that can help the instrument teams with the optimisation of the detector designs.
△ Less
Submitted 29 November, 2016; v1 submitted 8 July, 2016;
originally announced July 2016.
A comparison of Monte-Carlo simulations using RESTRAX and McSTAS with experiment on IN14
Authors:
A. R. Wildes,
J. Saroun,
E. Farhi,
I. Anderson,
P. Hoghoj,
A. Brochier
Abstract:
Monte-Carlo simulations of a focusing supermirror guide after the monochromator on the IN14 cold neutron three-axis spectrometer, I.L.L. were carried out using the instrument simulation programs RESTRAX and McSTAS. The simulations were compared to experiment to check their accuracy. Comparisons of the flux ratios over both a 100 mm2 and a 1600 mm2 area at the sample position compare well, and th…
▽ More
Monte-Carlo simulations of a focusing supermirror guide after the monochromator on the IN14 cold neutron three-axis spectrometer, I.L.L. were carried out using the instrument simulation programs RESTRAX and McSTAS. The simulations were compared to experiment to check their accuracy. Comparisons of the flux ratios over both a 100 mm2 and a 1600 mm2 area at the sample position compare well, and there is very close agreement between simulation and experiment for the energy spread of the incident beam.
△ Less
Submitted 1 September, 2000;
originally announced September 2000.