Reduced-Order Model of Power Converters to Optimize Power Hardware-In-the-Loop Technology in Dc-Distributed Systems
Authors:
Marina Sanz,
Daniel Santamargarita,
Francisco Huerta,
Diego Ochoa,
Antonio Lazaro,
Andres Barrado
Abstract:
The Power Hardware-In-the-Loop (PHIL) technology provides a powerful tool for testing scenarios where there is a high-power interchange, in which the performance of field tests can be very complex or expensive. When performing PHIL simulations of systems with a high number of components, such as DC-distributed systems on a ship or aircraft, the use of switched or average models of the converters c…
▽ More
The Power Hardware-In-the-Loop (PHIL) technology provides a powerful tool for testing scenarios where there is a high-power interchange, in which the performance of field tests can be very complex or expensive. When performing PHIL simulations of systems with a high number of components, such as DC-distributed systems on a ship or aircraft, the use of switched or average models of the converters can require the use of expensive commercial real-time digital simulators (RTDS) reducing the advantages of these technology. This paper is focused on the proposal of a reduced order model of converters to be able to perform PHIL analysis of Dc-distributed systems using low resources of the required real-time digital simulator. The paper validates that the proposed reduced-order model is able to determine the stability on the Dc-distributed system in comparison with more complex converter models. Moreover, a comparison between both models regarding the required resources in the implementation in a commercial RTDS platform is performed to validate the benefits of the proposed model in performing PHIL analysis of large power distribution systems.
△ Less
Submitted 31 January, 2024;
originally announced January 2024.
Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters
Authors:
Daniel Santamargarita,
Francisco Huerta,
Marina Sanz,
Antonio Lazaro,
Salvatore DArco,
Santiago Sanchez,
Elisabetta Tedeschi,
Javier Roldan
Abstract:
In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the systems presented above, the need to use more and more switched power converters has arisen. The main problem of the connection of multiple controlled switched…
▽ More
In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the systems presented above, the need to use more and more switched power converters has arisen. The main problem of the connection of multiple controlled switched converters acting as source and load is the degradation of stability that occurs on the DC distribution bus due to the converter interactions. To study the stability in the distribution bus there are some wellestablished criteria. These criteria require knowledge of the input impedance of the converters that act as load and the output impedance of the equipment that acts as source. In order to reduce the complexity of obtaining the input impedance a model based on a controlled converter acting as a constant power load (CPL) is commonly used. This article studies the accuracy of this model for a commonly used topology in distribution systems nowadays, Two Level Voltage Source Converter (2L-VSC), studying different scenarios that make the model become inaccurate.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.