-
Using random coherent states to mimic quantum illumination
Authors:
Thomas Brougham,
Nigam Samantaray,
John Jeffers
Abstract:
Quantum illumination uses quantum correlations to enhance the detection of an object in the presence of background noise. This advantage has been shown to exist even if one uses non-optimal direct measurements on the two correlated modes. Here we present a protocol that mimics the behaviour of quantum illumination, but does not use correlated or entangled modes. Instead, the protocol uses coherent…
▽ More
Quantum illumination uses quantum correlations to enhance the detection of an object in the presence of background noise. This advantage has been shown to exist even if one uses non-optimal direct measurements on the two correlated modes. Here we present a protocol that mimics the behaviour of quantum illumination, but does not use correlated or entangled modes. Instead, the protocol uses coherent (or phase-randomized coherent) pulses with randomly chosen intensities. The intensities are drawn from a distribution such that the average state looks thermal. Under appropriate conditions, the mimic protocol can perform similarly to quantum illumination schemes that use direct measurements. This holds even for a reflectance as low as $10^{-7}$. We also present an analytic condition which allows one to determine the sets of parameters in which each protocol works best.
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
Quantum illumination with multiplexed photodetection
Authors:
Hao Yang,
Nigam Samantaray,
John Jeffers
Abstract:
The advantages of using quantum states of light for object detection are often highlighted in schemes that use simultaneous and optimal measurements. Here, we describe a theoretical but experimentally realizable quantum illumination scheme based on non-simultaneous and non-optimal measurements which can maintain this advantage. In particular, we examine the multi-click heralded two mode squeezed v…
▽ More
The advantages of using quantum states of light for object detection are often highlighted in schemes that use simultaneous and optimal measurements. Here, we describe a theoretical but experimentally realizable quantum illumination scheme based on non-simultaneous and non-optimal measurements which can maintain this advantage. In particular, we examine the multi-click heralded two mode squeezed vacuum state as a probe signal in a quantum illumination process. The increase in conditioned signal intensity associated with multi-click heralding is greater than that from a single detector-heralded signal. Our results show, for lossy external conditions, the presence of the target object can be revealed earlier using multi-click measurements. We demonstrate this through sequential shot measurements based on Monte-Carlo simulation.
△ Less
Submitted 22 September, 2022;
originally announced September 2022.
-
Un-symmetric photon subtraction: a method for generating high photon number states and their relevance to loss estimation at ultimate quantum limit
Authors:
N. Samantaray,
J. C. F. Matthews,
J. G. Rarity
Abstract:
We have studied theoretical un-symmetric multi-photon subtracted twin beam state and demonstrated a method for generating states that resembles to high photon number states with the increase in the number of subtracted photons through Wigner distribution function, which can be reconstructed experimentally by Homodyne measurement. A crucial point is high non-classicality is obtained by photon subtr…
▽ More
We have studied theoretical un-symmetric multi-photon subtracted twin beam state and demonstrated a method for generating states that resembles to high photon number states with the increase in the number of subtracted photons through Wigner distribution function, which can be reconstructed experimentally by Homodyne measurement. A crucial point is high non-classicality is obtained by photon subtraction when mean photons per mode of twin beam state is low. We have calculated photon statistics from the phase space distribution function and found sub-poissonian behaviour in the same low mean photons regime. Furthermore, we have tested the usefulness of such states for realistic absorption measurement including detection losses by computing quantum Fisher-Information from measured Wigner function after interaction the sample. We have compared the performance of these states with respect to coherent and demonstrated how the quantum advantage is related to non-classical enhancement. We presented results up to three photon subtraction which show remarkable quantum advantage over both initial thermal and coherent state reaching the ultimate quantum limit in the loss estimation.
△ Less
Submitted 3 October, 2021;
originally announced October 2021.
-
Poissonian twin beam states and the effect of symmetrical photon subtraction in loss estimations
Authors:
N. Samantaray,
J. C. F. Matthews,
J. G. Rarity
Abstract:
We have devised an experimentally realizable model generating twin beam states whose individual beam photon statistics are varied from thermal to Poissonian kee** the non-classical mode correlation intact. We have studied the usefulness of these states for loss measurement by considering three different estimators, comparing with the correlated thermal twin beam states generated from spontaneous…
▽ More
We have devised an experimentally realizable model generating twin beam states whose individual beam photon statistics are varied from thermal to Poissonian kee** the non-classical mode correlation intact. We have studied the usefulness of these states for loss measurement by considering three different estimators, comparing with the correlated thermal twin beam states generated from spontaneous parametric down conversion or four-wave mixing. We then incorporated the photon subtraction operation into the model and demonstrate their advantage in loss estimations with respect to un-subtracted states at both fixed squeezing and per photon exposure of the absorbing sample. For instance, at fixed squeezing, for two photon subtraction, up to three times advantage is found. In the latter case, albeit the advantage due to photon subtraction mostly subsides in standard regime, an unexpected result is that in some operating regimes the photon subtraction scheme can also give up to 20% advantage over the correlated Poisson beam result. We have also made a comparative study of these estimators for finding the best measurement for loss estimations. We present results for all the values of the model parameters changing the statistics of twin beam states from thermal to Poissonian.
△ Less
Submitted 24 September, 2020;
originally announced September 2020.
-
A practical model of twin-beam experiments for sub-shot-noise absorption measurements
Authors:
Jason D. Mueller,
Nigam Samantaray,
Jonathan C. F. Matthews
Abstract:
Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the twin-beam intensity correlations, which is quantified by the noise reduction factor. We derive an analytical model of twin-beam experiments, incorporating experimenta…
▽ More
Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the twin-beam intensity correlations, which is quantified by the noise reduction factor. We derive an analytical model of twin-beam experiments, incorporating experimental parameters such as the relative detection efficiency of the beams, uncorrelated optical noise, and uncorrelated detector noise. We show that for twin beams without excessive noise, measured correlations can be improved by increasing the detection efficiency of each beam, notwithstanding this may unbalance detection efficiency. However, for beams with excess intensity or other experimental noise, one should balance detection efficiency, even at the cost of reducing detection efficiency -- we specifically define these noise conditions and verify our results with statistical simulation. This has application in design and optimization of absorption spectroscopy and imaging experiments.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
Improving resolution-sensitivity trade off in sub-shot noise imaging
Authors:
I. Ruo Berchera,
A. Meda,
E. Losero,
A. Avella,
N. Samantaray,
M. Genovese
Abstract:
One of the challenges of quantum technologies is realising the quantum advantage, predicted for ideal systems, in real applications, which have to cope with decoherence and inefficiencies. In quantum metrology, sub-shot-noise imaging (SSNI) and sensing methods can provide genuine quantum enhancement in realistic situations. However, wide field SSNI schemes realized so far suffer a trade-off betwee…
▽ More
One of the challenges of quantum technologies is realising the quantum advantage, predicted for ideal systems, in real applications, which have to cope with decoherence and inefficiencies. In quantum metrology, sub-shot-noise imaging (SSNI) and sensing methods can provide genuine quantum enhancement in realistic situations. However, wide field SSNI schemes realized so far suffer a trade-off between the resolution and the sensitivity gain over classical counterpart: small pixels or integrating area, are necessary to achieve high imaging resolution, but larger pixels allow a better detection efficiency of quantum correlations, which means a larger quantum advantage. Here we show how the SSNI protocol can be optimized to significantly improve the resolution without giving up the quantum advantage in the sensitivity. We show a linear resolution improvement (up to a factor 3) with respect to the simple protocol used in previous demonstrations.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Single phase and correlated phase estimation with multi-photon annihilated squeezed vacuum states: An energy balancing scenario
Authors:
Nigam Samantaray,
Ivano Ruo Berchera,
Ivo. P. Degiovanni
Abstract:
In the last years, several works have demonstrated the advantage of photon subtracted Gaussian states for various quantum optics and information protocols. In most of these works, it was not clearly investigated the relation between the advantages and the usual increasing energy of the quantum state related to photon subtraction. In this paper, we study the performance of an interferometer injecte…
▽ More
In the last years, several works have demonstrated the advantage of photon subtracted Gaussian states for various quantum optics and information protocols. In most of these works, it was not clearly investigated the relation between the advantages and the usual increasing energy of the quantum state related to photon subtraction. In this paper, we study the performance of an interferometer injected with multi photon annihilated squeezed vacuum states mixed with coherent states for both single and correlated phase estimation. For single phase estimation, albeit the use of multi-photon annihilated squeezed vacuum states at low mean photons per mode provide advantage compared to classical strategy, when the total input energies is held fixed, the advantage due to photon subtraction is completely lost. However, for the correlated case in analogous scenario, some advantage appears to come from both the energy rise and improvement in photon statistics. In particular quantum enhanced sensitivity with photon subtracted states appears more robust to losses, showing an advantage of about 30% with respect to squeezed vacuum state in case of realistic value of the detection efficiency.
△ Less
Submitted 1 March, 2021; v1 submitted 27 September, 2018;
originally announced September 2018.
-
Photon number correlation for quantum enhanced imaging and sensing
Authors:
Alice Meda,
Elena Losero,
Nigam Samantaray,
Fabio Scafirimuto,
Siva Pradyumna,
Alessio Avella,
Ivano Ruo-Berchera,
Marco Genovese
Abstract:
In this review we present the potentialities and the achievements of the use of non-classical photon number correlations in twin beams (TWB) states for many applications, ranging from imaging to metrology. Photon number correlations in the quantum regime are easy to be produced and are rather robust against unavoidable experimental losses, and noise in some cases, if compared to the entanglement,…
▽ More
In this review we present the potentialities and the achievements of the use of non-classical photon number correlations in twin beams (TWB) states for many applications, ranging from imaging to metrology. Photon number correlations in the quantum regime are easy to be produced and are rather robust against unavoidable experimental losses, and noise in some cases, if compared to the entanglement, where loosing one photon can completely compromise the state and its exploitable advantage. Here, we will focus on quantum enhanced protocols in which only phase-insensitive intensity measurements (photon number counting) are performed, which allow probing transmission/absorption properties of a system, leading for example to innovative target detection schemes in a strong background. In this framework, one of the advantages is that the sources experimentally available emit a wide number of pairwise correlated modes, which can be intercepted and exploited separately, for example by many pixels of a camera, providing a parallelism, essential in several applications, like wide field sub-shot-noise imaging and quantum enhanced ghost imaging. Finally, non-classical correlation enables new possibilities in quantum radiometry, e.g. the possibility of absolute calibration of a spatial resolving detector from the on-off- single photon regime to the linear regime, in the same setup.
△ Less
Submitted 18 April, 2017; v1 submitted 23 December, 2016;
originally announced December 2016.
-
Realisation of the first sub shot noise wide field microscope
Authors:
Nigam Samantaray,
Ivano Ruo-Berchera,
Alice Meda,
Marco Genovese
Abstract:
In the last years several proof of principle experiments have demonstrated the advantages of quantum technologies respect to classical schemes. The present challenge is to overpass the limits of proof of principle demonstrations to approach real applications. This letter presents such an achievement in the field of quantum enhanced imaging. In particular, we describe the realization of a sub-shot…
▽ More
In the last years several proof of principle experiments have demonstrated the advantages of quantum technologies respect to classical schemes. The present challenge is to overpass the limits of proof of principle demonstrations to approach real applications. This letter presents such an achievement in the field of quantum enhanced imaging. In particular, we describe the realization of a sub-shot noise wide field microscope based on spatially multi-mode non-classical photon number correlations in twin beams. The microscope produces real time images of 8000 pixels at full resolution, for (500micrometers)2 field-of-view, with noise reduced to the 80% of the shot noise level (for each pixel), suitable for absorption imaging of complex structures. By fast post-elaboration, specifically applying a quantum enhanced median filter, the noise can be further reduced (less than 30% of the shot noise level) by setting a trade-off with the resolution, demonstrating the best sensitivity per incident photon ever achieved in absorption microscopy.
△ Less
Submitted 19 December, 2016;
originally announced December 2016.
-
Realization of a twin beam source based on four-wave mixing in Cesium
Authors:
G. Adenier,
D. Calonico,
S. Micalizio,
N. Samantaray,
I. P. Degiovanni,
I. Ruo Berchera
Abstract:
Four-wave mixing (4WM) is a known source of intense non-classical twin beams. It can be generated when an intense laser beam (the pump) and a weak laser beam (the seed) overlap in a $χ^{(3)}$ medium (here cesium vapor), with frequencies close to resonance with atomic transitions. The twin beams generated by 4WM have frequencies naturally close to atomic transitions, and can be intense (gain…
▽ More
Four-wave mixing (4WM) is a known source of intense non-classical twin beams. It can be generated when an intense laser beam (the pump) and a weak laser beam (the seed) overlap in a $χ^{(3)}$ medium (here cesium vapor), with frequencies close to resonance with atomic transitions. The twin beams generated by 4WM have frequencies naturally close to atomic transitions, and can be intense (gain $\gg 1$) even in the CW pump regime, which is not the case for PDC $χ^{(2)}$ phenomenon in non-linear crystals. So, 4WM is well suited for atom-light interaction and atom-based quantum protocols. Here we present the first realization of a source of 4-wave mixing exploiting $D_2$ line of Cesium atoms.
△ Less
Submitted 6 April, 2016;
originally announced April 2016.
-
Two-mode squeezed vacuum and squeezed light in correlated interferometry
Authors:
I. Ruo Berchera,
I. P. Degiovanni,
S. Olivares,
N. Samantaray,
P. Traina,
M. Genovese
Abstract:
We study in detail a system of two interferometers aimed to the detection of extremely faint phase-fluctuations. This system can represent a breakthrough for detecting a faint correlated signal that would remain otherwise undetectable even using the most sensitive individual interferometric devices, that are limited by the shot noise. If the two interferometers experience identical phase-fluctuati…
▽ More
We study in detail a system of two interferometers aimed to the detection of extremely faint phase-fluctuations. This system can represent a breakthrough for detecting a faint correlated signal that would remain otherwise undetectable even using the most sensitive individual interferometric devices, that are limited by the shot noise. If the two interferometers experience identical phase-fluctuations, like the ones introduced by the so called "holographic noise", this signal should emerge if their output signals are correlated, while the fluctuations due to shot noise and other independent contributions will vanish. We show how the injecting quantum light in the free ports of the interferometers can reduce the photon noise of the system beyond the shot-noise, enhancing the resolution in the phase-correlation estimation. We analyze both the use of two-mode squeezed vacuum or twin-beam state (TWB) and of two independent squeezing states. Our results basically confirms the benefit of using squeezed beams together with strong coherent beams in interferometry, even in this correlated case. However, mainly we concentrate on the possible use of TWB, discovering interesting and probably unexplored areas of application of bipartite entanglement and in particular the possibility of reaching in principle surprising uncertainty reduction.
△ Less
Submitted 29 January, 2015;
originally announced January 2015.