-
Measurement of the Parity-Odd Angular Distribution of Gamma Rays From Polarized Neutron Capture on $^{35}$Cl
Authors:
N. Fomin,
R. Alarcon,
L. Alonzi,
E. Askanazi,
S. Baeßler,
S. Balascuta,
L. Barrón-Palos,
A. Barzilov,
D. Blyth,
J. D. Bowman,
N. Birge,
J. R. Calarco,
T. E. Chupp,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
K. Craycraft,
D. Evans,
C. Fieseler,
E. Frlež,
J. Fry,
I. Garishvili,
M. T. W. Gericke,
R. C. Gillis,
K. B. Grammer
, et al. (39 additional authors not shown)
Abstract:
We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-n…
▽ More
We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-nucleon (NN) interaction which mixes opposite parity S and P-wave levels in the excited compound $^{36}$Cl nucleus formed upon slow neutron capture. If parity-violating (PV) and parity-conserving (PC) terms both exist, the measured differential cross section can be related to them via $\frac{dσ}{dΩ}\propto1+A_{γ, PV}\cosθ+A_{γ,PC}\sinθ$. The PV and PC asymmetries for energy-weighted gamma cascade angular distributions for polarized slow neutron capture on $^{35}$Cl averaged over the neutron energies from 2.27~meV to 9.53~meV were measured to be $A_{γ,PV}=(-23.9\pm0.7)\times 10^{-6}$ and $A_{γ,PC}=(0.1\pm0.7)\times 10^{-6}$. These results are consistent with previous experimental results. Systematic errors were quantified and shown to be small compared to the statistical error. These asymmetries in the angular distributions of the gamma rays emitted from the capture of polarized neutrons in $^{35}$Cl were used to verify the operation and data analysis procedures for the NPDGamma experiment which measured the parity-odd asymmetry in the angular distribution of gammas from polarized slow neutron capture on protons.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
Using Nab to determine correlations in unpolarized neutron decay
Authors:
L. J. Broussard,
S. Baeßler,
T. L. Bailey,
N. Birge,
J. D. Bowman,
C. B. Crawford,
C. Cude-Woods,
D. E. Fellers,
N. Fomin,
E. Frlež,
M. T. W. Gericke,
L. Hayen,
A. P. Jezghani,
H. Li,
N. Macsai,
M. F. Makela,
R. R. Mammei,
D. Mathews,
P. L. McGaughey,
P. E. Mueller,
D. Počanić,
C. A. Royse,
A. Salas-Bacci,
S. K. L. Sjue,
J. C. Ramsey
, et al. (6 additional authors not shown)
Abstract:
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and…
▽ More
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
The Nab Experiment: A Precision Measurement of Unpolarized Neutron Beta Decay
Authors:
J. Fry,
R. Alarcon,
S. Baessler,
S. Balascuta,
L. Barron-Palos,
T. Bailey,
K. Bass,
N. Birge,
A. Blose,
D. Borissenko,
J. D. Bowman,
L. J. Broussard,
A. T. Bryant,
J. Byrne,
J. R. Calarco,
J. Caylor,
K. Chang,
T. Chupp,
T. V. Cianciolo,
C. Crawford,
X. Ding,
M. Doyle,
W. Fan,
W. Farrar,
N. Fomin
, et al. (47 additional authors not shown)
Abstract:
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlati…
▽ More
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter $a$ with a precision of $δa / a = 10^{-3}$ and the Fierz interference term $b$ to $δb = 3\times10^{-3}$ in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio $λ$ with a precision of $δλ/ λ= 0.03\%$ that will allow an evaluation of $V_{ud}$ and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.
△ Less
Submitted 7 January, 2020; v1 submitted 25 November, 2018;
originally announced November 2018.
-
First Observation of $P$-odd $γ$ Asymmetry in Polarized Neutron Capture on Hydrogen
Authors:
D. Blyth,
J. Fry,
N. Fomin,
R. Alarcon,
L. Alonzi,
E. Askanazi,
S. Baeßler,
S. Balascuta,
L. Barrón-Palos,
A. Barzilov,
J. D. Bowman,
N. Birge,
J. R. Calarco,
T. E. Chupp,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
K. Craycraft,
D. Evans,
C. Fieseler,
E. Frlež,
I. Garishvili,
M. T. W. Gericke,
R. C. Gillis,
K. B. Grammer
, et al. (39 additional authors not shown)
Abstract:
We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominat…
▽ More
We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless EFT. We measured $A^{np}_γ= [-3.0 \pm 1.4 (stat) \pm 0.2 (sys)]\times 10^{-8}$, which implies a DDH weak $πNN$ coupling of $h_π^{1} = [2.6 \pm 1.2(stat) \pm 0.2(sys)] \times 10^{-7}$ and a pionless EFT constant of $C^{^{3}S_{1}\rightarrow ^{3}P_{1}}/C_{0}=[-7.4 \pm 3.5 (stat) \pm 0.5 (sys)] \times 10^{-11}$ MeV$^{-1}$. We describe the experiment, data analysis, systematic uncertainties, and the implications of the result.
△ Less
Submitted 14 December, 2018; v1 submitted 26 July, 2018;
originally announced July 2018.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Neutron Beta Decay Studies with Nab
Authors:
S. Baeßler,
R. Alarcon,
L. P. Alonzi,
S. Balascuta,
L. Barrón-Palos,
J. D. Bowman,
M. A. Bychkov,
J. Byrne,
J. R. Calarco,
T. Chupp,
T. V. Vianciolo,
C. Crawford,
E. Frlež,
M. T. Gericke,
F. Glück,
G. L. Greene,
R. K. Grzywacz,
V. Gudkov,
D. Harrison,
F. W. Hersman,
T. Ito,
M. Makela,
J. Martin,
P. L. McGaughey,
S. McGovern
, et al. (9 additional authors not shown)
Abstract:
Precision measurements in neutron beta decay serve to determine the coupling constants of beta decay and allow for several stringent tests of the standard model. This paper discusses the design and the expected performance of the Nab spectrometer.
Precision measurements in neutron beta decay serve to determine the coupling constants of beta decay and allow for several stringent tests of the standard model. This paper discusses the design and the expected performance of the Nab spectrometer.
△ Less
Submitted 20 September, 2012;
originally announced September 2012.