-
A compact single-shot soft X-ray photon spectrometer for free electron laser diagnostics
Authors:
Kirk A. Larsen,
Kurtis Borne,
Razib Obaid,
Andrei Kamalov,
Yusong Liu,
Xinxin Cheng,
Justin James,
Taran Driver,
Kenan Li,
Yanwei Liu,
Anne Sakdinawat,
Christian David,
Thomas J. A. Wolf,
James Cryan,
Peter Walter,
Ming-Fu Lin
Abstract:
The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce…
▽ More
The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce-YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in an energy range which covers absorption edges associated with several atomic constituents carbon, nitrogen, oxygen, and neon. The spectrometer's performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with subelectronvolt energy resolution.
△ Less
Submitted 9 May, 2023;
originally announced May 2023.
-
XCC: An X-ray FEL-based $γγ$ Collider Higgs Factory
Authors:
Tim Barklow,
Su Dong,
Claudio Emma,
Joseph Duris,
Zhirong Huang,
Adham Naji,
Emilio Nanni,
James Rosenzweig,
Anne Sakdinawat,
Sami Tantawi,
Glen White
Abstract:
This report describes the design of a $γγ$ Higgs factory in which 62.8 GeV electron beams collide with 1 keV X-ray free electron laser (XFEL) beams to produce colliding beams of 62.5 GeV photons. The Higgs boson production rate is 34,000 Higgs bosons per $10^7$ second year, roughly the same as the ILC Higgs rate. The electron accelerator is based on cold copper distributed coupling (C$^3$) acceler…
▽ More
This report describes the design of a $γγ$ Higgs factory in which 62.8 GeV electron beams collide with 1 keV X-ray free electron laser (XFEL) beams to produce colliding beams of 62.5 GeV photons. The Higgs boson production rate is 34,000 Higgs bosons per $10^7$ second year, roughly the same as the ILC Higgs rate. The electron accelerator is based on cold copper distributed coupling (C$^3$) accelerator technology. The 0.7 J pulse energy of the XFEL represents a 300-fold increase over the pulse energy of current soft x-ray FEL's. Design challenges are discussed, along with the R\&D to address them, including demonstrators.
△ Less
Submitted 11 May, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Balanced Detection in Femtosecond X-ray Absorption Spectroscopy to Reach the Ultimate Sensitivity Limit
Authors:
W. F. Schlotter,
M. Beye,
S. Zohar,
G. Coslovich,
G. L. Dakovski,
M. -F. Lin,
Y. Liu,
A. Reid,
S. Stubbs,
P. Walter,
K. Nakahara,
P. Hart,
P. S. Miedema,
L. LeGuyader,
K. Hofhuis,
Phu Tran Phong Le,
Johan E. ten Elshof,
H. Hilgenkamp,
G. Koster,
X. H. Verbeek,
S. Smit,
M. S. Golden,
H. A. Durr,
A. Sakdinawat
Abstract:
X-ray absorption spectroscopy (XAS) is a powerful and well established technique with sensitivity to elemental and chemical composition. Despite these advantages, its implementation has not kept pace with the development of ultrafast pulsed x-ray sources where XAS can capture femtosecond chemical processes. X-ray Free Electron Lasers (XFELs) deliver femtosecond, narrow bandwidth (…
▽ More
X-ray absorption spectroscopy (XAS) is a powerful and well established technique with sensitivity to elemental and chemical composition. Despite these advantages, its implementation has not kept pace with the development of ultrafast pulsed x-ray sources where XAS can capture femtosecond chemical processes. X-ray Free Electron Lasers (XFELs) deliver femtosecond, narrow bandwidth ($\frac{ΔE}{E} < 0.5\%$) pulses containing $\sim 10^{10}$ photons. However, the energy contained in each pulse fluctuates thus complicating pulse by pulse efforts to quantify the number of photons. Improvements in counting the photons in each pulse have defined the state of the art for XAS sensitivity. Here we demonstrate a final step in these improvements through a balanced detection method that approaches the photon counting shot noise limit. In doing so, we obtain high quality absorption spectra from the insulator-metal transition in VO$_2$ and unlock a method to explore dilute systems, subtle processes and nonlinear phenomena with ultrafast x-rays. The method is especially beneficial for x-ray light sources where integration and averaging are not viable options to improve sensitivity.
△ Less
Submitted 24 June, 2020;
originally announced June 2020.
-
Sha** Coherent X-rays with Binary Optics
Authors:
Stefano Marchesini,
Anne Sakdinawat
Abstract:
Diffractive lenses fabricated by lithographic methods are one of the most popular image forming optics in the x-ray regime. Most commonly, binary diffractive optics, such as Fresnel zone plates are used due to their ability to focus at high resolution and to manipulate the x-ray wavefront. We report here a binary zone plate design strategy to form arbitrary illuminations for coherent multiplexing,…
▽ More
Diffractive lenses fabricated by lithographic methods are one of the most popular image forming optics in the x-ray regime. Most commonly, binary diffractive optics, such as Fresnel zone plates are used due to their ability to focus at high resolution and to manipulate the x-ray wavefront. We report here a binary zone plate design strategy to form arbitrary illuminations for coherent multiplexing, structured illumination, and wavefront sha** experiments. Given a desired illumination, we adjust the duty cycle, harmonic order, and zone placement to vary both the amplitude and phase of the wavefront at the lens. This enables the binary lithographic pattern to generate arbitrary structured illumination optimized for a variety of applications such as holography, interferometry, ptychography, imaging, and others.
△ Less
Submitted 25 December, 2018;
originally announced December 2018.
-
Experimental 3D Coherent Diffractive Imaging from photon-sparse random projections
Authors:
K. Giewekemeyer,
A. Aquila,
N. D. Loh,
Y. Chushkin,
K. S. Shanks,
J. Weiss,
M. W. Tate,
H. T. Philipp,
S. Stern,
P. Vagovic,
M. Mehrjoo,
C. Teo,
M. Barthelmess,
F. Zontone,
C. Chang,
R. C. Tiberio,
A. Sakdinawat,
G. J. Williams,
S. M. Gruner,
A. P. Mancuso
Abstract:
The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules. Extremely-bright, ultrashort-pulse X-ray sources---X-ray Free Electron Lasers (XFELs)---provide X-rays that can be used to probe ensembles of nearly identical nano-scale…
▽ More
The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules. Extremely-bright, ultrashort-pulse X-ray sources---X-ray Free Electron Lasers (XFELs)---provide X-rays that can be used to probe ensembles of nearly identical nano-scale particles. When combined with coherent diffractive imaging, these objects can be imaged; however, as the resolution of the images approaches the atomic scale, the measured data are increasingly difficult to obtain and, during an X-ray pulse, the number of photons incident on the two-dimensional detector is much smaller than the number of pixels. This latter concern, the signal "sparsity," materially impedes the application of the method. We demonstrate an experimental analog using a synchrotron X-ray source that yields signal levels comparable to those expected from single biomolecules illuminated by focused XFEL pulses. The analog experiment provides an invaluable cross-check on the fidelity of the reconstructed data that is not available during XFEL experiments. We establish---using this experimental data---that a sparsity of order $1.3\times10^{-3}$ photons per pixel per frame can be overcome, lending vital insight to the solution of the atomic-resolution XFEL single particle imaging problem by experimentally demonstrating 3D coherent diffractive imaging from photon-sparse random projections.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
Characterization of Spatial Coherence of Synchrotron Radiation with Non-Redundant Arrays of Apertures
Authors:
P. Skopintsev,
A. Singer,
J. Bach,
L. Muller,
B. Beyersdorf,
S. Schleitzer,
O. Gorobtsov,
A. Shabalin,
R. Kurta,
D. Dzhigaev,
O. M. Yefanov,
L. Glaser,
A. Sakdinawat,
Y. Liu,
G. Grubel,
R. Fromter,
H. P. Oepen,
J. Viefhaus,
I. A. Vartanyants
Abstract:
We present a method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern. The technique is based on scattering from non-redundant arrays (NRA) of slits and records the degree of spatial coherence at several relative separations from one to 15 microns, simultaneously. Using NRAs we measured the transverse coherence of the X-ray beam at the XUV X-ray beamli…
▽ More
We present a method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern. The technique is based on scattering from non-redundant arrays (NRA) of slits and records the degree of spatial coherence at several relative separations from one to 15 microns, simultaneously. Using NRAs we measured the transverse coherence of the X-ray beam at the XUV X-ray beamline P04 of the PETRA III synchrotron storage ring as a function of different beam parameters. To verify the results obtained with the NRAs additional Young's double pinhole experiments were conducted and show good agreement.
△ Less
Submitted 25 February, 2014;
originally announced February 2014.
-
Spatial and temporal coherence properties of single free-electron laser pulses
Authors:
A. Singer,
F. Sorgenfrei,
A. P. Mancuso,
N. Gerasimova,
O. M. Yefanov,
J. Gulden,
T. Gorniak,
T. Senkbeil,
A. Sakdinawat,
Y. Liu,
D. Attwood,
S. Dziarzhytski,
D. D. Mai,
R. Treusch,
E. Weckert,
T. Salditt,
A. Rosenhahn,
W. Wurth,
I. A. Vartanyants
Abstract:
The experimental characterization of the spatial and temporal coherence properties of the free-electron laser in Hamburg (FLASH) at a wavelength of 8.0 nm is presented. Double pinhole diffraction patterns of single femtosecond pulses focused to a size of about 10 microns by 10 microns were measured. A transverse coherence length of 6.2 microns in the horizontal and 8.7 microns in the vertical dire…
▽ More
The experimental characterization of the spatial and temporal coherence properties of the free-electron laser in Hamburg (FLASH) at a wavelength of 8.0 nm is presented. Double pinhole diffraction patterns of single femtosecond pulses focused to a size of about 10 microns by 10 microns were measured. A transverse coherence length of 6.2 microns in the horizontal and 8.7 microns in the vertical direction was determined from the most coherent pulses. Using a split and delay unit the coherence time of the pulses produced in the same operation conditions of FLASH was measured to be 1.75 fs. From our experiment we estimated the degeneracy parameter of the FLASH beam to be on the order of $10^{10}$ to $10^{11}$, which exceeds the values of this parameter at any other source in the same energy range by many orders of magnitude.
△ Less
Submitted 5 June, 2012;
originally announced June 2012.
-
Coherence Properties of Individual Femtosecond Pulses of an X-ray Free-Electron Laser
Authors:
I. A. Vartanyants,
A. Singer,
A. P. Mancuso,
O. Yefanov,
A. Sakdinawat,
Y. Liu,
E. Bang,
G. J. Williams,
G. Cadenazzi,
B. Abbey,
H. Sinn,
D. Attwood,
K. A. Nugent,
E. Weckert,
T. Wang,
D. Zhu,
B. Wu,
C. Graves,
A. Scherz,
J. J. Turner,
W. F. Schlotter,
M. Messerschmidt,
J. Luning,
Y. Acremann,
P. Heimann
, et al. (11 additional authors not shown)
Abstract:
Measurements of the spatial and temporal coherence of single, femtosecond x-ray pulses generated by the first hard x-ray free-electron laser (FEL), the Linac Coherent Light Source (LCLS), are presented. Single shot measurements were performed at 780 eV x-ray photon energy using apertures containing double pinholes in "diffract and destroy" mode. We determined a coherence length of 17 micrometers i…
▽ More
Measurements of the spatial and temporal coherence of single, femtosecond x-ray pulses generated by the first hard x-ray free-electron laser (FEL), the Linac Coherent Light Source (LCLS), are presented. Single shot measurements were performed at 780 eV x-ray photon energy using apertures containing double pinholes in "diffract and destroy" mode. We determined a coherence length of 17 micrometers in the vertical direction, which is approximately the size of the focused LCLS beam in the same direction. The analysis of the diffraction patterns produced by the pinholes with the largest separation yields an estimate of the temporal coherence time of 0.6 fs. We find that the total degree of transverse coherence is 56% and that the x-ray pulses are adequately described by two transverse coherent modes in each direction. This leads us to the conclusion that 78% of the total power is contained in the dominant mode.
△ Less
Submitted 19 May, 2011;
originally announced May 2011.
-
Ultrafast, ultrabright, X-ray holography using a uniformly-redundant array
Authors:
S. Marchesini,
S. Boutet,
A. E. Sakdinawat,
M. J. Bogan,
S. Bajt,
A. Barty,
H. N. Chapman,
M. Frank,
S. P. Hau-Riege,
A. Szoke,
C. Cui,
M. R. Howells,
D. A. Shapiro,
J. C. H. Spence,
J. W. Shaevitz,
J. Y. Lee,
J. Hajdu,
M. M. Seibert
Abstract:
Advances in the development of free-electron lasers offer the realistic prospect of high-resolution imaging to study the nanoworld on the time-scale of atomic motions. We identify X-ray Fourier Transform holography, (FTH) as a promising but, so far, inefficient scheme to do this. We show that a uniformly redundant array (URA) placed next to the sample, multiplies the efficiency of X-ray FTH by m…
▽ More
Advances in the development of free-electron lasers offer the realistic prospect of high-resolution imaging to study the nanoworld on the time-scale of atomic motions. We identify X-ray Fourier Transform holography, (FTH) as a promising but, so far, inefficient scheme to do this. We show that a uniformly redundant array (URA) placed next to the sample, multiplies the efficiency of X-ray FTH by more than one thousand (approaching that of a perfect lens) and provides holographic images with both amplitude- and phase-contrast information. The experiments reported here demonstrate this concept by imaging a nano-fabricated object at a synchrotron source, and a bacterial cell at a soft X-ray free-electron-laser, where illumination by a single 15 fs pulse was successfully used in producing the holographic image. We expect with upcoming hard X-ray lasers to achieve considerably higher spatial resolution and to obtain ultrafast movies of excited states of matter.
△ Less
Submitted 8 February, 2008; v1 submitted 31 January, 2008;
originally announced January 2008.