-
Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources
Authors:
Habib Safigholi,
Marc J. P. Chamberland,
Randle E. P. Taylor,
Martin P. Martinov,
D. W. O. Rogers,
Rowan M. Thomson
Abstract:
PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2…
▽ More
PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary and Scatter Separated (PSS) dose tables, and mean photon energies esca** each source. The database also documents the source models which will be freely distributed with egs_brachy. ACQUISITION AND VALIDATION METHODS: Datasets are calculated after a recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air kerma per history is calculated in a 10x10x0.05 cm3 voxel located 100 cm from the source along the transverse axis and then corrected for the lateral and thickness dimensions of the scoring voxel to give the air kerma on the central axis at a point 100cm from the source's mid-point. Full-scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. For validation, data are compared to those from CLRP_TG43v1 and published data. DATA FORMAT AND ACCESS: Data are available at https://physics.carleton.ca/clrp/egs_brachy/seed_database_HDRv2 or http://doi.org/10.22215/clrp/tg43v2. POTENTIAL APPLICATIONS: The CLRP_TG43v2 database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more precise and in some cases more accurate Monte Carlo TG-43 dose calculation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy.
△ Less
Submitted 7 December, 2022;
originally announced December 2022.
-
Update of the CLRP eye plaque brachytherapy database for photon-emitting sources
Authors:
Habib Safigholi,
Zack Parsons,
Stephen G. Deering,
Rowan M. Thomson
Abstract:
Purpose: To update and extend the Carleton Laboratory for Radiotherapy Physics (CLRP) Eye Plaque (EP) dosimetry database for low-energy photon-emitting brachytherapy sources using egs_brachy, an open-source EGSnrc application. The previous database, CLRP_EPv1, contained datasets for the Collaborative Ocular Melanoma Study (COMS) plaques (2008). The new database, CLRP EPv2, consists of newly-calcul…
▽ More
Purpose: To update and extend the Carleton Laboratory for Radiotherapy Physics (CLRP) Eye Plaque (EP) dosimetry database for low-energy photon-emitting brachytherapy sources using egs_brachy, an open-source EGSnrc application. The previous database, CLRP_EPv1, contained datasets for the Collaborative Ocular Melanoma Study (COMS) plaques (2008). The new database, CLRP EPv2, consists of newly-calculated 3D dose distributions for 17 plaques [8 COMS, 5 Eckert & Ziegler BEBIG, and 4 other representative models] for Pd-103, I-125, and Cs-131 seeds.
Methods: Plaque models are developed with egs_brachy, based on published/manufacturer dimensions and material data. The BEBIG plaques are identical in dimensions to COMS plaques but differ in elemental composition and/or density. Eye plaques and seeds are simulated at the centre of full-scatter water phantoms, scoring in (0.05 cm)^3 voxels spanning the eye for scenarios: (i) HOMO: simulated TG43 conditions; (ii) HETERO: eye plaques and seeds fully modelled; (iii) HETsi (BEBIG only): one seed is active at a time with other seed geometries present but not emitting photons (inactive). For validation, doses are compared to those from CLRP_EPv1 and published data.
Data Format and Access: Data are available at https://physics.carleton.ca/ clrp/eye_plaque_v2, http://doi.org/10.22215/clrp/EPv2. The data consist of 3D dose distributions (text-based EGSnrc 3ddose file) and graphical presentations of the comparisons to previously published data.
Potential Applications: The CLRP EPv2 database provides accurate reference 3D dose distributions to advance ocular brachytherapy dose evaluations. The fully-benchmarked eye plaque models will be freely-distributed with egs brachy, supporting adoption of model-based dose evaluations as recommended by TG-129, TG-186, and TG-221.
△ Less
Submitted 5 February, 2021;
originally announced February 2021.
-
Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources
Authors:
Habib Safigholi,
Marc J. P. Chamberland,
Randle E. P. Taylor,
Christian H. Allen,
Martin P. Martinov,
D. W. O. Rogers,
Rowan M. Thomson
Abstract:
PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A…
▽ More
PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A comprehensive set of TG-43 parameters is calculated, including dose-rate constants, radial dose functions with functional fitting parameters, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary-Scatter separation dose tables (for some sources), and mean photon energies. The database also documents the source models which will become part of the egs_brachy distribution. METHODS: Datasets are calculated after a systematic recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Full scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. New statistical uncertainties of source volume corrections for phantom voxels which overlap with brachytherapy sources are implemented in egs_brachy, and all CLRPv2 data include these uncertainties. For validation, data are compared to CLRPv1 and other data in the literature. DATA ACCESS/FORMAT: Data are available at https://physics.carleton.ca/ clrp/egs_brachy/seed_database_v2. As well as being presented graphically in comparisons to previous calculations, data are available in Excel (.xlsx) spreadsheets for each source. APPLICATIONS: The database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more accurate TG-43 dose evaluation parameters, as well as fully-benchmarked source models distributed with egs_brachy.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.
-
Dermatologist Level Dermoscopy Skin Cancer Classification Using Different Deep Learning Convolutional Neural Networks Algorithms
Authors:
Amirreza Rezvantalab,
Habib Safigholi,
Somayeh Karimijeshni
Abstract:
In this paper, the effectiveness and capability of convolutional neural networks have been studied in the classification of 8 skin diseases. Different pre-trained state-of-the-art architectures (DenseNet 201, ResNet 152, Inception v3, InceptionResNet v2) were used and applied on 10135 dermoscopy skin images in total (HAM10000: 10015, PH2: 120). The utilized dataset includes 8 diagnostic categories…
▽ More
In this paper, the effectiveness and capability of convolutional neural networks have been studied in the classification of 8 skin diseases. Different pre-trained state-of-the-art architectures (DenseNet 201, ResNet 152, Inception v3, InceptionResNet v2) were used and applied on 10135 dermoscopy skin images in total (HAM10000: 10015, PH2: 120). The utilized dataset includes 8 diagnostic categories - melanoma, melanocytic nevi, basal cell carcinoma, benign keratosis, actinic keratosis and intraepithelial carcinoma, dermatofibroma, vascular lesions, and atypical nevi. The aim is to compare the ability of deep learning with the performance of highly trained dermatologists. Overall, the mean results show that all deep learning models outperformed dermatologists (at least 11%). The best ROC AUC values for melanoma and basal cell carcinoma are 94.40% (ResNet 152) and 99.30% (DenseNet 201) versus 82.26% and 88.82% of dermatologists, respectively. Also, DenseNet 201 had the highest macro and micro averaged AUC values for overall classification (98.16%, 98.79%, respectively).
△ Less
Submitted 21 October, 2018;
originally announced October 2018.