-
Three-dimensional radiation dosimetry based on optically-stimulated luminescence
Authors:
Michal Sadel,
Ellen Marie Høye,
Peter Skyt,
Ludvig Paul Muren,
Jørgen Breede Baltzer Petersenand,
Peter Balling
Abstract:
A new approach to three-dimensional (3D) dosimetry based on optically-stimulated luminescence (OSL) is presented. By embedding OSL-active particles into a transparent silicone matrix (PDMS), the well-established dosimetric properties of an OSL material are exploited in a 3D-OSL dosimeter. By investigating prototype dosimeters in standard cuvettes in combination with small test samples for OSL read…
▽ More
A new approach to three-dimensional (3D) dosimetry based on optically-stimulated luminescence (OSL) is presented. By embedding OSL-active particles into a transparent silicone matrix (PDMS), the well-established dosimetric properties of an OSL material are exploited in a 3D-OSL dosimeter. By investigating prototype dosimeters in standard cuvettes in combination with small test samples for OSL readers, it is shown that a sufficient transparency of the 3D-OSL material can be combined with an OSL response giving an estimated >10.000 detected photons in 1 second per 1mm3 voxel of the dosimeter at a dose of 1 Gy. The dose distribution in the 3D-OSL dosimeters can be directly read out optically without the need for subsequent reconstruction by computational inversion algorithms. The dosimeters carry the advantages known from personal-dosimetry use of OSL: the dose distribution following irradiation can be stored with minimal fading for extended periods of time, and dosimeters are reusable as they can be reset, e.g. by an intense (bleaching) light field.
△ Less
Submitted 19 January, 2017;
originally announced January 2017.
-
Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose
Authors:
P. Bilski,
M. Sadel,
J. Swakon,
A. Weber
Abstract:
The high-temperature ratio (HTR) is a parameter quantifying changes of the shape of the high-temperature part of the LiF:Mg,Ti glow-curve after exposure to densely ionizing radiation. It was introduced in order to estimate the effective LET of an unknown radiation field and to correct the decreased relative TL efficiency for high Linear Energy Transfer (LET) radiation. In the present work the depe…
▽ More
The high-temperature ratio (HTR) is a parameter quantifying changes of the shape of the high-temperature part of the LiF:Mg,Ti glow-curve after exposure to densely ionizing radiation. It was introduced in order to estimate the effective LET of an unknown radiation field and to correct the decreased relative TL efficiency for high Linear Energy Transfer (LET) radiation. In the present work the dependence of HTR on proton energy (14.5 to 58 MeV) and dose (0.5 to 30 Gy) was investigated. All measured HTR values were at the level of 1.2 or higher, therefore significantly different from the respective value for gamma rays (HTR is equal to 1), but HTR was found to be insensitive to changes of proton energy above 20 MeV. As a result the relationship between HTR and relative TL efficiency is not unequivocal. The HTR was found to be dependent on absorbed dose even for the lowest studied doses.
△ Less
Submitted 27 February, 2014;
originally announced February 2014.
-
Properties of lithium aluminate for application as OSL dosimeter
Authors:
A. Twardak,
P. Bilski,
B. Marczewska,
J. I. Lee,
J. L. Kim,
W. Gieszczyk,
A. Piaskowska,
M. Sadel,
D. Wróbel
Abstract:
Several samples of lithium aluminate (LiAlO2) were prepared in an attempt to achieve material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. Both undoped and carbon or copper doped lithium aluminate samples were investigated. The results of preliminary study of theirs reproducibility, sensitivity, dose response characteristic and fading are presented. Applications i…
▽ More
Several samples of lithium aluminate (LiAlO2) were prepared in an attempt to achieve material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. Both undoped and carbon or copper doped lithium aluminate samples were investigated. The results of preliminary study of theirs reproducibility, sensitivity, dose response characteristic and fading are presented. Applications in mixed field (beta, alpha, neutrons) dosimetry are discussed.
△ Less
Submitted 25 February, 2014;
originally announced February 2014.