Optical Hemodynamic Imaging of Jugular Venous Dynamics During Altered Central Venous Pressure
Authors:
Robert Amelard,
Andrew D Robertson,
Courtney A Patterson,
Hannah Heigold,
Essi Saarikoski,
Richard L Hughson
Abstract:
An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure. The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible…
▽ More
An optical imaging system is proposed for quantitatively assessing jugular venous response to altered central venous pressure. The proposed system assesses sub-surface optical absorption changes from jugular venous waveforms with a spatial calibration procedure to normalize incident tissue illumination. Widefield frames of the right lateral neck were captured and calibrated using a novel flexible surface calibration method. A hemodynamic optical model was derived to quantify jugular venous optical attenuation (JVA) signals, and generate a spatial jugular venous pulsatility map. JVA was assessed in three cardiovascular protocols that altered central venous pressure: acute central hypovolemia (lower body negative pressure), venous congestion (head-down tilt), and impaired cardiac filling (Valsalva maneuver). JVA waveforms exhibited biphasic wave properties consistent with jugular venous pulse dynamics when time-aligned with an electrocardiogram. JVA correlated strongly (median, interquartile range) with invasive central venous pressure during graded central hypovolemia (r=0.85, [0.72, 0.95]), graded venous congestion (r=0.94, [0.84, 0.99]), and impaired cardiac filling (r=0.94, [0.85, 0.99]). Reduced JVA during graded acute hypovolemia was strongly correlated with reductions in stroke volume (SV) (r=0.85, [0.76, 0.92]) from baseline (SV: 79$\pm$15 mL, JVA: 0.56$\pm$0.10 a.u.) to -40 mmHg suction (SV: 59$\pm$18 mL, JVA: 0.47$\pm$0.05 a.u.; p$<$0.01). The proposed non-contact optical imaging system demonstrated jugular venous dynamics consistent with invasive central venous monitoring during three protocols that altered central venous pressure. This system provides non-invasive monitoring of pressure-induced jugular venous dynamics in clinically relevant conditions where catheterization is traditionally required, enabling monitoring in non-surgical environments.
△ Less
Submitted 24 March, 2021; v1 submitted 22 July, 2020;
originally announced July 2020.