-
Quantification of Collateral Supply with Local-AIF Dynamic Susceptibility Contrast MRI Predicts Infarct Growth
Authors:
Mira M. Liu,
Niloufar Saadat,
Steven P. Roth,
Marek A. Niekrasz,
Mihai Giurcanu,
Timothy J. Carroll,
Gregory A. Christoforidis
Abstract:
In ischemic stroke, leptomeningeal collaterals can provide compensatory blood flow to tissue at risk despite an occlusion, and impact treatment response and infarct growth. The purpose of this work is to test the hypothesis that local perfusion with an appropriate Local Arterial Input Function (AIF) is needed to quantify the degree of collateral blood supply in tissue distal to an occlusion. Seven…
▽ More
In ischemic stroke, leptomeningeal collaterals can provide compensatory blood flow to tissue at risk despite an occlusion, and impact treatment response and infarct growth. The purpose of this work is to test the hypothesis that local perfusion with an appropriate Local Arterial Input Function (AIF) is needed to quantify the degree of collateral blood supply in tissue distal to an occlusion. Seven experiments were conducted in a pre-clinical middle cerebral artery occlusion model. Magnetic resonance dynamic susceptibility contrast (DSC) was imaged and post-processed as cerebral blood flow maps with both a traditionally chosen single arterial input function (AIF) applied globally to the whole brain (i.e. "Global-AIF") and a novel automatic delay and dispersion corrected AIF (i.e. "Local AIF") that is sensitive to retrograde flow. Pial collateral recruitment was assessed from x-ray angiograms and infarct growth via serially acquired diffusion weighted MRI scans both blinded to DSC. The degree of collateralization at x-ray correlated strongly with quantitative perfusion determined using the Local AIF in the ischemic penumbra (R2=0.81) compared to a traditionally chosen Global-AIF (R2=0.05). Quantitative perfusion calculated using a Local-AIF was negatively correlated (less infarct progression as local perfusion increased) with infarct growth (R2 = 0.79) compared to Global-AIF (R2=0.02). Local DSC perfusion with a Local-AIF is more accurate for assessing tissue status and degree of leptomeningeal collateralization than traditionally chosen AIFs. These findings support use of a Local-AIF in determining quantitative tissue perfusion with collateral supply in occlusive disease.
△ Less
Submitted 6 June, 2024;
originally announced June 2024.
-
Quantitative perfusion and water transport time model from multi b-value diffusion magnetic resonance imaging validated against neutron capture microspheres
Authors:
M. Liu,
N. Saadat,
Y. Jeong,
S. Roth,
M. Niekrasz,
M. Giurcanu,
T. Carroll,
G. Christoforidis
Abstract:
Intravoxel Incoherent Motion (IVIM) is a non-contrast magnetic resonance imaging diffusion-based scan that uses a multitude of b-values to measure various speeds of molecular perfusion and diffusion, sidestep** inaccuracy of arterial input functions or bolus kinetics in quantitative imaging. We test a new method of IVIM quantification and compare our values to reference standard neutron capture…
▽ More
Intravoxel Incoherent Motion (IVIM) is a non-contrast magnetic resonance imaging diffusion-based scan that uses a multitude of b-values to measure various speeds of molecular perfusion and diffusion, sidestep** inaccuracy of arterial input functions or bolus kinetics in quantitative imaging. We test a new method of IVIM quantification and compare our values to reference standard neutron capture microspheres across normocapnia, CO2 induced hypercapnia, and middle cerebral artery occlusion in a controlled animal model. Perfusion quantification in ml/100g/min compared to microsphere perfusion uses the 3D gaussian probability distribution and defined water transport time as when 50% of the molecules remain in the tissue of interest. Perfusion, water transport time, and infarct volume was compared to reference standards. Simulations were studied to suppress non-specific cerebrospinal fluid (CSF). Linear regression analysis of quantitative perfusion returned correlation (slope = .55, intercept = 52.5, $R^2$= .64). Linear regression for water transport time asymmetry in infarcted tissue was excellent (slope = .59, intercept = .3, $R^2$ = .93). Strong linear agreement also was found for infarct volume (slope = 1.01, $R^2$= .79). Simulation of CSF suppression via inversion recovery returned blood signal reduced by 82% from combined T1 and T2 effects. Intra-physiologic state comparison of perfusion shows potential partial volume effects which require further study especially in disease states. The accuracy and sensitivity of IVIM provides evidence that observed signal changes reflect cytotoxic edema and tissue perfusion. Partial volume contamination of CSF may be better removed during post-processing rather than with inversion recovery to avoid artificial loss of blood signal.
△ Less
Submitted 4 April, 2023;
originally announced April 2023.
-
SAFETY: Secure gwAs in Federated Environment Through a hYbrid solution with Intel SGX and Homomorphic Encryption
Authors:
Md Nazmus Sadat,
Md Momin Al Aziz,
Noman Mohammed,
Feng Chen,
Shuang Wang,
Xiaoqian Jiang
Abstract:
Recent studies demonstrate that effective healthcare can benefit from using the human genomic information. For instance, analysis of tumor genomes has revealed 140 genes whose mutations contribute to cancer. As a result, many institutions are using statistical analysis of genomic data, which are mostly based on genome-wide association studies (GWAS). GWAS analyze genome sequence variations in orde…
▽ More
Recent studies demonstrate that effective healthcare can benefit from using the human genomic information. For instance, analysis of tumor genomes has revealed 140 genes whose mutations contribute to cancer. As a result, many institutions are using statistical analysis of genomic data, which are mostly based on genome-wide association studies (GWAS). GWAS analyze genome sequence variations in order to identify genetic risk factors for diseases. These studies often require pooling data from different sources together in order to unravel statistical patterns or relationships between genetic variants and diseases. In this case, the primary challenge is to fulfill one major objective: accessing multiple genomic data repositories for collaborative research in a privacy-preserving manner. Due to the sensitivity and privacy concerns regarding the genomic data, multi-jurisdictional laws and policies of cross-border genomic data sharing are enforced among different regions of the world. In this article, we present SAFETY, a hybrid framework, which can securely perform GWAS on federated genomic datasets using homomorphic encryption and recently introduced secure hardware component of Intel Software Guard Extensions (Intel SGX) to ensure high efficiency and privacy at the same time. Different experimental settings show the efficacy and applicability of such hybrid framework in secure conduction of GWAS. To the best of our knowledge, this hybrid use of homomorphic encryption along with Intel SGX is not proposed or experimented to this date. Our proposed framework, SAFETY is up to 4.82 times faster than the best existing secure computation technique.
△ Less
Submitted 7 March, 2017;
originally announced March 2017.