-
First antineutrino energy spectrum from $^{235}$U fissions with the STEREO detector at ILL
Authors:
STEREO collaboration,
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
P. del Amo Sanchez,
I. El Atmani,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Licciardi,
M. Lindner,
T. Materna,
H. Pessard,
J. -S. Réal,
J. -S. Ricol,
C. Roca,
R. Rogly,
T. Salagnac,
V. Savu,
S. Schoppmann,
V. Sergeyeva,
T. Soldner
, et al. (2 additional authors not shown)
Abstract:
This article reports the measurement of the $^{235}$U-induced antineutrino spectrum shape by the STEREO experiment. 43'000 antineutrinos have been detected at about 10 m from the highly enriched core of the ILL reactor during 118 full days equivalent at nominal power. The measured inverse beta decay spectrum is unfolded to provide a pure $^{235}$U spectrum in antineutrino energy. A careful study o…
▽ More
This article reports the measurement of the $^{235}$U-induced antineutrino spectrum shape by the STEREO experiment. 43'000 antineutrinos have been detected at about 10 m from the highly enriched core of the ILL reactor during 118 full days equivalent at nominal power. The measured inverse beta decay spectrum is unfolded to provide a pure $^{235}$U spectrum in antineutrino energy. A careful study of the unfolding procedure, including a cross-validation by an independent framework, has shown that no major biases are introduced by the method. A significant local distortion is found with respect to predictions around $E_ν\simeq 5.3$ MeV. A gaussian fit of this local excess leads to an amplitude of $A = 12.1 \pm 3.4\%$ (3.5$σ$).
△ Less
Submitted 4 June, 2021; v1 submitted 5 October, 2020;
originally announced October 2020.
-
Accurate Measurement of the Electron Antineutrino Yield of U-235 Fissions from the STEREO Experiment with 119 Days of Reactor-On Data
Authors:
STEREO Collaboration,
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
P. del Amo Sanchez,
I. El Atmani,
J. Haser,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Licciardi,
M. Lindner,
T. Materna,
A. Minotti,
A. Onillon,
H. Pessard,
J. -S. Réal,
C. Roca,
R. Rogly,
T. Salagnac,
V. Savu,
S. Schoppmann
, et al. (4 additional authors not shown)
Abstract:
We report a measurement of the antineutrino rate from the fission of U-235 with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched U-235 fuel. We measure an IBD cross section per fission of $σ_f$ = (6.34 $\pm$ 0.06 [stat] $\pm$ 0.15 [sys] $\pm$ 0.15 [model…
▽ More
We report a measurement of the antineutrino rate from the fission of U-235 with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched U-235 fuel. We measure an IBD cross section per fission of $σ_f$ = (6.34 $\pm$ 0.06 [stat] $\pm$ 0.15 [sys] $\pm$ 0.15 [model]) $\times$ 10${}^{-43}$ cm${}^{2}$/fission and observe a rate deficit of (5.2 $\pm$ 0.8 [stat] $\pm$ 2.3 [sys] $\pm$ 2.3 [model])% compared to the model, consistent with the deficit of the world average. Testing U-235 as the sole source of the deficit, we find a tension between the results of lowly and highly enriched U-235 fuel of 2.1 standard deviations.
△ Less
Submitted 10 November, 2020; v1 submitted 8 April, 2020;
originally announced April 2020.
-
Improved Sterile Neutrino Constraints from the STEREO Experiment with 179 Days of Reactor-On Data
Authors:
STEREO Collaboration,
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
P. del Amo Sanchez,
I. El Atmani,
J. Haser,
F. Kandzia,
S. Kox,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Licciardi,
M. Lindner,
T. Materna,
A. Minotti,
H. Pessard,
J. -S. Réal,
C. Roca,
R. Rogly,
T. Salagnac,
V. Savu
, et al. (5 additional authors not shown)
Abstract:
The STEREO experiment is a very short baseline reactor antineutrino experiment. It is designed to test the hypothesis of light sterile neutrinos being the cause of a deficit of the observed antineutrino interaction rate at short baselines with respect to the predicted rate, known as the reactor antineutrino anomaly. The STEREO experiment measures the antineutrino energy spectrum in six identical d…
▽ More
The STEREO experiment is a very short baseline reactor antineutrino experiment. It is designed to test the hypothesis of light sterile neutrinos being the cause of a deficit of the observed antineutrino interaction rate at short baselines with respect to the predicted rate, known as the reactor antineutrino anomaly. The STEREO experiment measures the antineutrino energy spectrum in six identical detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this article, results from 179 days of reactor turned on and 235 days of reactor turned off are reported at a high degree of detail. The current results include improvements in the modelling of detector optical properties and the gamma-cascade after neutron captures by gadolinium, the treatment of backgrounds, and the statistical method of the oscillation analysis. Using a direct comparison between antineutrino spectra of all cells, largely independent of any flux prediction, we find the data compatible with the null oscillation hypothesis. The best-fit point of the reactor antineutrino anomaly is rejected at more than 99.9% C.L.
△ Less
Submitted 9 September, 2020; v1 submitted 13 December, 2019;
originally announced December 2019.
-
Electronics for the STEREO experiment
Authors:
V. Hélaine,
STEREO collaboration
Abstract:
The STEREO experiment, aiming to probe short baseline neutrino oscillations by precisely measuring reactor anti-neutrino spectrum, is currently under installation. It is located at short distance from the compact research reactor core of the Institut Laue-Langevin, Grenoble, France. Dedicated electronics, hosted in a single $μ$TCA crate, were designed for this experiment. In this article, the elec…
▽ More
The STEREO experiment, aiming to probe short baseline neutrino oscillations by precisely measuring reactor anti-neutrino spectrum, is currently under installation. It is located at short distance from the compact research reactor core of the Institut Laue-Langevin, Grenoble, France. Dedicated electronics, hosted in a single $μ$TCA crate, were designed for this experiment. In this article, the electronics requirements, architecture and the performances achieved are described. It is shown how intrinsic Pulse Shape Discrimination properties of the liquid scintillator are preserved and how custom adaptable logic is used to improve the muon veto efficiency.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.