-
Strong Charge-Photon Coupling in Planar Germanium Enabled by Granular Aluminium Superinductors
Authors:
Marián Janík,
Kevin Roux,
Carla Borja Espinosa,
Oliver Sagi,
Abdulhamid Baghdadi,
Thomas Adletzberger,
Stefano Calcaterra,
Marc Botifoll,
Alba Garzón Manjón,
Jordi Arbiol,
Daniel Chrastina,
Giovanni Isella,
Ioan M. Pop,
Georgios Katsaros
Abstract:
High kinetic inductance superconductors are gaining increasing interest for the realisation of qubits, amplifiers and detectors. Moreover, thanks to their high impedance, quantum buses made of such materials enable large zero-point fluctuations of the voltage, boosting the coupling rates to spin and charge qubits. However, fully exploiting the potential of disordered or granular superconductors is…
▽ More
High kinetic inductance superconductors are gaining increasing interest for the realisation of qubits, amplifiers and detectors. Moreover, thanks to their high impedance, quantum buses made of such materials enable large zero-point fluctuations of the voltage, boosting the coupling rates to spin and charge qubits. However, fully exploiting the potential of disordered or granular superconductors is challenging, as their inductance and, therefore, impedance at high values are difficult to control. Here we have integrated a granular aluminium resonator, having a characteristic impedance exceeding the resistance quantum, with a germanium double quantum dot and demonstrate strong charge-photon coupling with a rate of $g_\text{c}/2π= (566 \pm 2)$ MHz. This was achieved due to the realisation of a wireless ohmmeter, which allows \emph{in situ} measurements during film deposition and, therefore, control of the kinetic inductance of granular aluminium films. Reproducible fabrication of circuits with impedances (inductances) exceeding 13 k$Ω$ (1 nH per square) is now possible. This broadly applicable method opens the path for novel qubits and high-fidelity, long-distance two-qubit gates.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
A gate tunable transmon qubit in planar Ge
Authors:
Oliver Sagi,
Alessandro Crippa,
Marco Valentini,
Marian Janik,
Levon Baghumyan,
Giorgio Fabris,
Lucky Kapoor,
Farid Hassani,
Johannes Fink,
Stefano Calcaterra,
Daniel Chrastina,
Giovanni Isella,
Georgios Katsaros
Abstract:
Gate-tunable transmons (gatemons) employing semiconductor Josephson junctions have recently emerged as building blocks for hybrid quantum circuits. In this study, we present a gatemon fabricated in planar Germanium. We induce superconductivity in a two-dimensional hole gas by evaporating aluminum atop a thin spacer, which separates the superconductor from the Ge quantum well. The Josephson junctio…
▽ More
Gate-tunable transmons (gatemons) employing semiconductor Josephson junctions have recently emerged as building blocks for hybrid quantum circuits. In this study, we present a gatemon fabricated in planar Germanium. We induce superconductivity in a two-dimensional hole gas by evaporating aluminum atop a thin spacer, which separates the superconductor from the Ge quantum well. The Josephson junction is then integrated into an Xmon circuit and capacitively coupled to a transmission line resonator. We showcase the qubit tunability in a broad frequency range with resonator and two-tone spectroscopy. Time-domain characterizations reveal energy relaxation and coherence times up to 75 ns. Our results, combined with the recent advances in the spin qubit field, pave the way towards novel hybrid and protected qubits in a group IV, CMOS-compatible material.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Parity-conserving Cooper-pair transport and ideal superconducting diode in planar Germanium
Authors:
Marco Valentini,
Oliver Sagi,
Levon Baghumyan,
Thijs de Gijsel,
Jason Jung,
Stefano Calcaterra,
Andrea Ballabio,
Juan Aguilera Servin,
Kushagra Aggarwal,
Marian Janik,
Thomas Adletzberger,
Rubén Seoane Souto,
Martin Leijnse,
Jeroen Danon,
Constantin Schrade,
Erik Bakkers,
Daniel Chrastina,
Giovanni Isella,
Georgios Katsaros
Abstract:
Superconductor/semiconductor hybrid devices have attracted increasing interest in the past years. Superconducting electronics aims to complement semiconductor technology, while hybrid architectures are at the forefront of new ideas such as topological superconductivity and protected qubits. In this work, we engineer the induced superconductivity in two-dimensional germanium hole gas by varying the…
▽ More
Superconductor/semiconductor hybrid devices have attracted increasing interest in the past years. Superconducting electronics aims to complement semiconductor technology, while hybrid architectures are at the forefront of new ideas such as topological superconductivity and protected qubits. In this work, we engineer the induced superconductivity in two-dimensional germanium hole gas by varying the distance between the quantum well and the aluminum. We demonstrate a hard superconducting gap and realize an electrically and flux tunable superconducting diode using a superconducting quantum interference device (SQUID). This allows to tune the current phase relation (CPR), to a regime where single Cooper pair tunneling is suppressed, creating a $\sin \left( 2 \varphi \right)$ CPR. Shapiro experiments complement this interpretation and the microwave drive allows to create a diode with 100% efficiency. The reported results open up the path towards integration of spin qubit devices, microwave resonators and (protected) superconducting qubits on a silicon technology compatible platform.
△ Less
Submitted 16 November, 2023; v1 submitted 12 June, 2023;
originally announced June 2023.
-
Polarised superlocalization in magnetic nanoparticle hyperthermia
Authors:
Zs. Iszaly,
I. Gresits,
I. G. Marian,
Gy. Thuroczy,
O. Sagi,
B. G. Markus,
F. Simon,
I. Nandori
Abstract:
Magnetic hyperthermia is an adjuvant therapy for cancer where injected magnetic nanoparticles are used to transfer energy from the time-dependent applied magnetic field into the surrounding medium. Its main importance is to be able to increase the temperature of the human body locally. This localization can be further increased by using a combination of static and alternating external magnetic fie…
▽ More
Magnetic hyperthermia is an adjuvant therapy for cancer where injected magnetic nanoparticles are used to transfer energy from the time-dependent applied magnetic field into the surrounding medium. Its main importance is to be able to increase the temperature of the human body locally. This localization can be further increased by using a combination of static and alternating external magnetic fields. For example, if the static field is inhomogeneous and the alternating field is oscillating then the energy transfer and consequently, the heat generation is non-vanishing only where the gradient field is zero which results in superlocalization. Our goal here is to study theoretically and experimentally whether the perpendicular or parallel combination of static and oscillating fields produce a better superlocalization. A considerable polarisation effect in superlocalization for small frequencies and large field strengths which are of great importance in practice is found.
△ Less
Submitted 23 February, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
A singlet triplet hole spin qubit in planar Ge
Authors:
Daniel Jirovec,
Andrea Hofmann,
Andrea Ballabio,
Philipp M. Mutter,
Giulio Tavani,
Marc Botifoll,
Alessandro Crippa,
Josip Kukucka,
Oliver Sagi,
Frederico Martins,
Jaime Saez-Mollejo,
Ivan Prieto,
Maksim Borovkov,
Jordi Arbiol,
Daniel Chrastina,
Giovanni Isella,
Georgios Katsaros
Abstract:
Spin qubits are considered to be among the most promising candidates for building a quantum processor. GroupIV hole spin qubits have moved into the focus of interest due to the ease of operation and compatibility with Si technology. In addition, Ge offers the option for monolithic superconductor-semiconductor integration. Here we demonstrate a hole spin qubit operating at fields below 10 mT, the c…
▽ More
Spin qubits are considered to be among the most promising candidates for building a quantum processor. GroupIV hole spin qubits have moved into the focus of interest due to the ease of operation and compatibility with Si technology. In addition, Ge offers the option for monolithic superconductor-semiconductor integration. Here we demonstrate a hole spin qubit operating at fields below 10 mT, the critical field of Al, by exploiting the large out-of-plane hole g-factors in planar Ge and by encoding the qubit into the singlet-triplet states of a double quantum dot. We observe electrically controlled g-factor-difference-driven and exchange-driven rotations with tunable frequencies exceeding 100 MHz and dephasing times of 1 $μ$s which we extend beyond 150 $μ$s with echo techniques. These results demonstrate that Ge hole singlet-triplet qubits are competing with state-of-the art GaAs and Si singlet-triplet qubits. In addition, their rotation frequencies and coherence are on par with Ge single spin qubits, but they can be operated at much lower fields underlining their potential for on chip integration with superconducting technologies.
△ Less
Submitted 7 April, 2021; v1 submitted 27 November, 2020;
originally announced November 2020.
-
Tuning Conductivity and Spin Dynamics in Few-Layer Graphene via In Situ Potassium Exposure
Authors:
B. G. Márkus,
O. Sági,
S. Kollarics,
K. F. Edelthalhammer,
A. Hirsch,
F. Hauke,
P. Szirmai,
B. Náfrádi,
L. Forró,
F. Simon
Abstract:
Chemical modification, such as intercalation or do** of novel materials is of great importance for exploratory material science and applications in various fields of physics and chemistry. In the present work, we report the systematic intercalation of chemically exfoliated few-layer graphene with potassium while monitoring the sample resistance using microwave conductivity. We find that the cond…
▽ More
Chemical modification, such as intercalation or do** of novel materials is of great importance for exploratory material science and applications in various fields of physics and chemistry. In the present work, we report the systematic intercalation of chemically exfoliated few-layer graphene with potassium while monitoring the sample resistance using microwave conductivity. We find that the conductivity of the samples increases by about an order of magnitude upon potassium exposure. The increased of number of charge carriers deduced from the ESR intensity also reflects this increment. The doped phases exhibit two asymmetric Dysonian lines in ESR, a usual sign of the presence of mobile charge carriers. The width of the broader component increases with the do** steps, however, the narrow components seem to have a constant line width.
△ Less
Submitted 14 July, 2020;
originally announced July 2020.
-
Non-exponential magnetic relaxation in magnetic nanoparticles for hyperthermia
Authors:
I. Gresits,
Gy. Thuroczy,
O. Sagi,
S. Kollarics,
G. Csosz,
B. G. Markus,
N. M. Nemes,
M. Garcia Hernandez,
F. Simon
Abstract:
Magnetic nanoparticle based hyperthermia emerged as a potential tool for treating malignant tumours. The efficiency of the method relies on the knowledge of magnetic properties of the samples; in particular, knowledge of the frequency dependent complex magnetic susceptibility is vital to optimize the irradiation conditions and to provide feedback for material science developments. We study the fre…
▽ More
Magnetic nanoparticle based hyperthermia emerged as a potential tool for treating malignant tumours. The efficiency of the method relies on the knowledge of magnetic properties of the samples; in particular, knowledge of the frequency dependent complex magnetic susceptibility is vital to optimize the irradiation conditions and to provide feedback for material science developments. We study the frequency-dependent magnetic susceptibility of an aqueous ferrite suspension for the first time using non-resonant and resonant radiofrequency reflectometry. We identify the optimal measurement conditions using a standard solenoid coil, which is capable of providing the complex magnetic susceptibility up to 150 MHz. The result matches those obtained from a radiofrequency resonator for a few discrete frequencies. The agreement between the two different methods validates our approach. Surprisingly, the dynamic magnetic susceptibility cannot be explained by an exponential magnetic relaxation behavior even when we consider a particle size-dependent distribution of the relaxation parameter.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Ultrafast sensing of photoconductivity decay using microwave resonators
Authors:
B. Gyüre-Garami,
B. Blum,
O. Sági,
A. Bojtor,
S. Kollarics,
G. Csősz,
B. G. Márkus,
J. Volk,
F. Simon
Abstract:
Microwave reflectance probed photoconductivity (or $μ$-PCD) measurement represents a contactless and non-invasive method to characterize impurity content in semiconductors. Major drawbacks of the method include a difficult separation of reflectance due to dielectric and conduction effects and that the $μ$-PCD signal is prohibitively weak for highly conducting samples. Both of these limitations cou…
▽ More
Microwave reflectance probed photoconductivity (or $μ$-PCD) measurement represents a contactless and non-invasive method to characterize impurity content in semiconductors. Major drawbacks of the method include a difficult separation of reflectance due to dielectric and conduction effects and that the $μ$-PCD signal is prohibitively weak for highly conducting samples. Both of these limitations could be tackled with the use of microwave resonators due to the well-known sensitivity of resonator parameters to minute changes in the material properties combined with a null measurement. A general misconception is that time resolution of resonator measurements is limited beyond their bandwidth by the readout electronics response time. While it is true for conventional resonator measurements, such as those employing a frequency sweep, we present a time-resolved resonator parameter readout method which overcomes these limitations and allows measurement of complex material parameters and to enhance $μ$-PCD signals with the ultimate time resolution limit being the resonator time constant. This is achieved by detecting the transient response of microwave resonators on the timescale of a few 100 ns \emph{during} the $μ$-PCD decay signal. The method employs a high-stability oscillator working with a fixed frequency which results in a stable and highly accurate measurement.
△ Less
Submitted 4 December, 2019; v1 submitted 30 September, 2019;
originally announced September 2019.
-
A highly accurate determination of absorbed power during nanomagnetic hyperthermia
Authors:
I. Gresits,
Gy. Thuróczy,
O. Sági,
I. Homolya,
G. Bagaméry,
D. Gajári,
M. Babos,
P. Major,
B. G. Márkus,
F. Simon
Abstract:
Absorbed power of nanoparticles during magnetic hyperthermia can be well determined from changes in the quality factor ($Q$ factor) of a resonator, in which the radiofrequency (RF) absorbent is placed. We present an order of magnitude improvement in the $Q$ factor measurement accuracy over conventional methods by studying the switch-on and off transient signals of the resonators. A nuclear magneti…
▽ More
Absorbed power of nanoparticles during magnetic hyperthermia can be well determined from changes in the quality factor ($Q$ factor) of a resonator, in which the radiofrequency (RF) absorbent is placed. We present an order of magnitude improvement in the $Q$ factor measurement accuracy over conventional methods by studying the switch-on and off transient signals of the resonators. A nuclear magnetic resonance (NMR) console is ideally suited to acquire the transient signals and it also allows to employ the so-called pulse phase-cycling to remove transient artifacts. The improved determination of the absorbed power is demonstrated on various resonators in the 1-30 MHz range including standard solenoids and also a birdcage resonator. This leads to the possibility to detect minute amounts of ferrite nanoparticles which are embedded in the body and also the amount of the absorbed power. We demonstrate this capability on a phantom study, where the exact location of an embedded ferrite is clearly detected.
△ Less
Submitted 4 April, 2019;
originally announced April 2019.
-
Electronic properties of air-sensitive nanomaterials probed with microwave impedance measurements
Authors:
B. G. Márkus,
G. Csősz,
O. Sági,
B. Gyüre-Garami,
V. Lloret,
S. Wild,
G. Abellán,
N. M. Nemes,
G. Klupp,
K. Kamarás,
A. Hirsch,
F. Hauke,
F. Simon
Abstract:
Characterization of electronic properties of novel materials is of great importance for exploratory materials development and also for the discovery of new correlated phases. As several novel compounds are available in powder form only, contactless methods, which also work on air sensitive samples, are higly desired. We present that the microwave cavity perturbation technique is a versatile tool t…
▽ More
Characterization of electronic properties of novel materials is of great importance for exploratory materials development and also for the discovery of new correlated phases. As several novel compounds are available in powder form only, contactless methods, which also work on air sensitive samples, are higly desired. We present that the microwave cavity perturbation technique is a versatile tool to study conductivity in such systems. The examples include studies on semiconducting-metallic crossover in carbon nanotubes upon alkali do**, study of vortex motion in the K$_3$C$_{60}$ superconductor, and the characterization of various alkali atom doped phases of black phosphorus.
△ Less
Submitted 21 August, 2018; v1 submitted 11 June, 2018;
originally announced June 2018.
-
Heating causes non-linear microwave absorption anomaly in single wall carbon nanotubes
Authors:
B. G. Márkus,
B. Gyüre-Garami,
O. Sági,
G. Csősz,
F. Márkus,
F. Simon
Abstract:
Microwave impedance measurements indicate a non-linear absorption anomaly in single wall carbon nanotubes at low temperatures (below $20$ K). We investigate the nature of the anomaly using a time resolved microwave impedance measurement technique. It proves that the anomaly has an extremely slow, a few hundred second long dynamics. This strongly suggests that the anomaly is not caused by an intrin…
▽ More
Microwave impedance measurements indicate a non-linear absorption anomaly in single wall carbon nanotubes at low temperatures (below $20$ K). We investigate the nature of the anomaly using a time resolved microwave impedance measurement technique. It proves that the anomaly has an extremely slow, a few hundred second long dynamics. This strongly suggests that the anomaly is not caused by an intrinsic electronic effect and that it is rather due to a slow heat exchange between the sample and the environment.
△ Less
Submitted 26 June, 2018; v1 submitted 11 June, 2018;
originally announced June 2018.
-
A highly accurate measurement of resonator $Q$-factor and resonance frequency
Authors:
B. Gyüre-Garami,
O. Sági,
B. G. Márkus,
F. Simon
Abstract:
The microwave cavity perturbation method is often used to determine material parameters (electric permittivity and magnetic permeability) at high frequencies and it relies on measurement of the resonator parameters. We present a method to determine the $Q$-factor and resonance frequency of microwave resonators which is conceptually simple but provides a sensitivity for these parameters which overc…
▽ More
The microwave cavity perturbation method is often used to determine material parameters (electric permittivity and magnetic permeability) at high frequencies and it relies on measurement of the resonator parameters. We present a method to determine the $Q$-factor and resonance frequency of microwave resonators which is conceptually simple but provides a sensitivity for these parameters which overcomes those of existing methods by an order of magnitude. The microwave resonator is placed in a feedback resonator setup, where the output of an amplifier is connected to its own input with the resonator as a band pass filter. After reaching steady-state oscillation, the feedback circuit is disrupted by a fast microwave switch and the transient signal, which emanates from the resonator, is detected using down-conversion. The Fourier transform of the resulting time-dependent signal yields directly the resonance profile of the resonator. Albeit the method is highly accurate, this comes with a conceptual simplicity, ease of implementation and lower circuit cost. We compare existing methods for this type of measurement to explain the sensitivity of the present technique and we also make a prediction for the ultimate sensitivity for the resonator $Q$ and $f_0$ determination.
△ Less
Submitted 1 August, 2018; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Non-calorimetric determination of absorbed power during magnetic nanoparticle based hyperthermia
Authors:
I. Gresits,
Gy. Thuróczy,
O. Sági,
B. Gyüre-Garami,
B. G. Márkus,
F. Simon
Abstract:
Nanomagnetic hyperthermia (NMH) is intensively studied with the prospect of cancer therapy. A major challenge is to determine the dissipated power during in vivo conditions and conventional methods are either invasive or inaccurate. We present a non-calorimetric method which yields the heat absorbed during hyperthermia: it is based on accurately measuring the quality factor change of a resonant ra…
▽ More
Nanomagnetic hyperthermia (NMH) is intensively studied with the prospect of cancer therapy. A major challenge is to determine the dissipated power during in vivo conditions and conventional methods are either invasive or inaccurate. We present a non-calorimetric method which yields the heat absorbed during hyperthermia: it is based on accurately measuring the quality factor change of a resonant radio frequency circuit which is employed for the irradiation. The approach provides the absorbed power in real-time, without the need to monitor the sample temperature as a function of time. As such, it is free from the problems caused by the non-adiabatic heating conditions of the usual calorimetry. We validate the method by comparing the dissipated power with a conventional calorimetric measurement. We present the validation for two types of resonators with very different filling factors: a solenoid and a so-called birdcage coil. The latter is a volume coil, which is generally used in magnetic resonance imaging (MRI) under in vivo condition. The presented method therefore allows to effectively combine MRI and thermotherapy and is thus readily adaptable to existing imaging hardware.
△ Less
Submitted 25 July, 2018; v1 submitted 24 March, 2018;
originally announced March 2018.