-
Polarisation of radio-frequency magnetic fields in magnetic induction measurements with an atomic magnetometer
Authors:
L. M. Rushton,
L. M. Ellis,
J. D. Zipfel,
P. Bevington,
W. Chalupczak
Abstract:
We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarisation of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields created by more than one source. The discussion, illustrated by theoretical and experimental studies, is done in the context of the signals produced by electri…
▽ More
We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarisation of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields created by more than one source. The discussion, illustrated by theoretical and experimental studies, is done in the context of the signals produced by electrically conductive and magnetically permeable plates in magnetic induction tomography measurements. We show that different components of the secondary magnetic fields create the object response depending on the properties of the material, with the polarisation of the rf field varying across the object's surface. We argue that the ability of the sensor to simultaneously detect different field components enables the optimisation of measurement strategies for different object compositions.
△ Less
Submitted 5 January, 2024;
originally announced January 2024.
-
Spin noise spectroscopy of an alignment-based atomic magnetometer
Authors:
Marcin Kozbial,
Lucy Elson,
Lucas M. Rushton,
Ali Akbar,
Adil Meraki,
Kasper Jensen,
Jan Kolodynski
Abstract:
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pum** with circular or linear polarized light, r…
▽ More
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pum** with circular or linear polarized light, respectively. Characterisation of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pum**-probing beam. By varying the strength of the noise applied as well as the linear-polarisation angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding line-widths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks.
△ Less
Submitted 9 December, 2023;
originally announced December 2023.
-
Alignment-based optically pumped magnetometer using a buffer gas cell
Authors:
L. M. Rushton,
L. Elson,
A. Meraki,
K. Jensen
Abstract:
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells to extend the spin relaxation lifetimes of the alkali vapour. The drawback of these cells is that they are hand-blown and are therefore time-intensive, and some…
▽ More
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells to extend the spin relaxation lifetimes of the alkali vapour. The drawback of these cells is that they are hand-blown and are therefore time-intensive, and somewhat unreliable, to produce. Buffer gas cells, on the other hand, can be manufactured on a mass scale using microfabrication techniques. We present the first demonstration of an alignment-based magnetometer using a buffer gas vapour cell containing caesium (Cs) alkali vapour and nitrogen (N2) buffer gas. The OPM is operated at 55 degrees C and we achieve a 325 fT/sqrt(Hz) sensitivity to 10 kHz oscillating magnetic fields with an 800 Hz bandwidth. The alignment-based magnetometer uses a single laser beam for optical pum** and probing and could potentially allow for more rapid commercialisation of radio-frequency OPMs, due to the robustness of the one-beam geometry and the potential for mass-scale microfabrication of buffer gas cells.
△ Less
Submitted 18 January, 2023;
originally announced January 2023.
-
Detection and characterisation of conductive objects using electromagnetic induction and a fluxgate magnetometer
Authors:
Lucy Elson,
Adil Meraki,
Lucas M. Rushton,
Tadas Pyragius,
Kasper Jensen
Abstract:
Eddy currents induced in electrically conductive objects can be used to locate metallic objects as well as to assess the properties of materials non-destructively without physical contact. This technique is useful for material identification, such as measuring conductivity and for discriminating whether a sample is magnetic or non-magnetic. In this study, we carried out experiments and numerical s…
▽ More
Eddy currents induced in electrically conductive objects can be used to locate metallic objects as well as to assess the properties of materials non-destructively without physical contact. This technique is useful for material identification, such as measuring conductivity and for discriminating whether a sample is magnetic or non-magnetic. In this study, we carried out experiments and numerical simulations for the evaluation of conductive objects. We investigated the frequency dependence of the secondary magnetic field generated by induced eddy currents when a conductive object is placed in a primary oscillating magnetic field. According to the electromagnetic theory, conductive objects have different responses at different frequencies. Using a table-top setup consisting of a fluxgate magnetometer and a primary coil generating a magnetic field with frequency up to 1 kHz, we are able to detect aluminium and steel cylinders using the principle of electromagnetic induction. The experimental results are compared with numerical simulations and we find overall a good agreement. This technique enables identification and characterisation of objects using their electrical conductivity and magnetic permeability.
△ Less
Submitted 24 June, 2022;
originally announced June 2022.
-
Unshielded portable optically pumped magnetometer for the remote detection of conductive objects using eddy current measurements
Authors:
L. M. Rushton,
T. Pyragius,
A. Meraki,
L. Elson,
K. Jensen
Abstract:
Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be measured with a magnetometer. We have developed a portable radio-frequency optically pumped magnetometer (RF OPM) working in unshielded conditions with sub-pT/sqr…
▽ More
Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be measured with a magnetometer. We have developed a portable radio-frequency optically pumped magnetometer (RF OPM) working in unshielded conditions with sub-pT/sqrt(Hz) magnetic field sensitivity when used for the detection of small oscillating magnetic fields, setting a new benchmark for the sensitivity of a portable RF OPM in unshielded conditions. Using this OPM, we have detected the induced magnetic field from aluminium disks with diameters as small as 1.5 cm and with the disks being ~25 cm from both the excitation coil and the magnetometer. When used for eddy current detection, our magnetometer achieves a sensitivity of a 2-6 pT/sqrt(Hz). We have also detected a moving aluminium disk using our RF OPM and analysed the magnetometer signals which depend on the position of the disk, illustrating the potential of high sensitivity RF OPMs for remote sensing applications.
△ Less
Submitted 1 December, 2022; v1 submitted 9 June, 2022;
originally announced June 2022.