-
Demonstrating a long-coherence dual-rail erasure qubit using tunable transmons
Authors:
Harry Levine,
Arbel Haim,
Jimmy S. C. Hung,
Nasser Alidoust,
Mahmoud Kalaee,
Laura DeLorenzo,
E. Alex Wollack,
Patricio Arrangoiz-Arriola,
Amirhossein Khalajhedayati,
Rohan Sanil,
Hesam Moradinejad,
Yotam Vaknin,
Aleksander Kubica,
David Hover,
Shahriar Aghaeimeibodi,
Joshua Ari Alcid,
Christopher Baek,
James Barnett,
Kaustubh Bawdekar,
Przemyslaw Bienias,
Hugh Carson,
Cliff Chen,
Li Chen,
Harut Chinkezian,
Eric M. Chisholm
, et al. (88 additional authors not shown)
Abstract:
Quantum error correction with erasure qubits promises significant advantages over standard error correction due to favorable thresholds for erasure errors. To realize this advantage in practice requires a qubit for which nearly all errors are such erasure errors, and the ability to check for erasure errors without dephasing the qubit. We demonstrate that a "dual-rail qubit" consisting of a pair of…
▽ More
Quantum error correction with erasure qubits promises significant advantages over standard error correction due to favorable thresholds for erasure errors. To realize this advantage in practice requires a qubit for which nearly all errors are such erasure errors, and the ability to check for erasure errors without dephasing the qubit. We demonstrate that a "dual-rail qubit" consisting of a pair of resonantly coupled transmons can form a highly coherent erasure qubit, where transmon $T_1$ errors are converted into erasure errors and residual dephasing is strongly suppressed, leading to millisecond-scale coherence within the qubit subspace. We show that single-qubit gates are limited primarily by erasure errors, with erasure probability $p_\text{erasure} = 2.19(2)\times 10^{-3}$ per gate while the residual errors are $\sim 40$ times lower. We further demonstrate mid-circuit detection of erasure errors while introducing $< 0.1\%$ dephasing error per check. Finally, we show that the suppression of transmon noise allows this dual-rail qubit to preserve high coherence over a broad tunable operating range, offering an improved capacity to avoid frequency collisions. This work establishes transmon-based dual-rail qubits as an attractive building block for hardware-efficient quantum error correction.
△ Less
Submitted 20 March, 2024; v1 submitted 17 July, 2023;
originally announced July 2023.
-
In-flight gain monitoring of SPIDER's transition-edge sensor arrays
Authors:
J. P. Filippini,
A. E. Gambrel,
A. S. Rahlin,
E. Y. Young,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
A. A. Fraisse,
K. Freese,
M. Galloway,
N. N. Gandilo,
K. Ganga,
R. Gualtieri
, et al. (45 additional authors not shown)
Abstract:
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical respons…
▽ More
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES's small-signal power response from its electrical response that is exact in the limit of strong electrothermal feedback. We discuss the application and validation of this method using flight data from SPIDER, a balloon-borne telescope that observes the polarization of the cosmic microwave background with more than 2000 TESs. This method may prove useful for future balloon- and space-based instruments, where observing time and ground control bandwidth are limited.
△ Less
Submitted 16 June, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
A Simulation-Based Method for Correcting Mode Coupling in CMB Angular Power Spectra
Authors:
J. S. -Y. Leung,
J. Hartley,
J. M. Nagy,
C. B. Netterfield,
J. A. Shariff,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (45 additional authors not shown)
Abstract:
Modern CMB analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-…
▽ More
Modern CMB analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-$C_\ell$ based, MASTER-style analyses, the net effect of the time-domain filtering is commonly approximated by a multiplicative transfer function, $F_{\ell}$, that can fail to capture mode mixing and is dependent on the spectrum of the signal. To address these shortcomings, we have developed a simulation-based spectral correction approach that constructs a two-dimensional transfer matrix, $J_{\ell\ell'}$, which contains information about mode mixing in addition to mode attenuation. We demonstrate the application of this approach on data from the first flight of the SPIDER balloon-borne CMB experiment.
△ Less
Submitted 21 April, 2022; v1 submitted 1 November, 2021;
originally announced November 2021.
-
Impedance-matched differential superconducting nanowire detectors
Authors:
Marco Colangelo,
Boris Korzh,
Jason P. Allmaras,
Andrew D. Beyer,
Andrew S. Mueller,
Ryan M. Briggs,
Bruce Bumble,
Marcus Runyan,
Martin J. Stevens,
Adam N. McCaughan,
Di Zhu,
Stephen Smith,
Wolfgang Becker,
Lautaro Narváez,
Joshua C. Bienfang,
Simone Frasca,
Angel E. Velasco,
Cristián H. Peña,
Edward E. Ramirez,
Alexander B. Walter,
Ekkehart Schmidt,
Emma E. Wollman,
Maria Spiropulu,
Richard Mirin,
Sae Woo Nam
, et al. (2 additional authors not shown)
Abstract:
Superconducting nanowire single-photon detectors (SNSPDs) are the highest performing photon-counting technology in the near-infrared (NIR). Due to delay-line effects, large area SNSPDs typically trade-off timing resolution and detection efficiency. Here, we introduce a detector design based on transmission line engineering and differential readout for device-level signal conditioning, enabling a h…
▽ More
Superconducting nanowire single-photon detectors (SNSPDs) are the highest performing photon-counting technology in the near-infrared (NIR). Due to delay-line effects, large area SNSPDs typically trade-off timing resolution and detection efficiency. Here, we introduce a detector design based on transmission line engineering and differential readout for device-level signal conditioning, enabling a high system detection efficiency and a low detector jitter, simultaneously. To make our differential detectors compatible with single-ended time taggers, we also engineer analog differential-to-single-ended readout electronics, with minimal impact on the system timing resolution. Our niobium nitride differential SNSPDs achieve $47.3\,\% \pm 2.4\,\%$ system detection efficiency and sub-$10\,\mathrm{ps}$ system jitter at $775\,\mathrm{nm}$, while at $1550\,\mathrm{nm}$ they achieve $71.1\,\% \pm 3.7\,\%$ system detection efficiency and $13.1\,\mathrm{ps} \pm 0.4\,\mathrm{ps}$ system jitter. These detectors also achieve sub-100 ps timing response at one one-hundredth maximum level, $30.7\,\mathrm{ps} \pm 0.4\,\mathrm{ps}$ at $775\,\mathrm{nm}$ and $47.6\,\mathrm{ps} \pm 0.4\,\mathrm{ps}$ at $1550\,\mathrm{nm}$, enabling time-correlated single-photon counting with high dynamic range response functions. Furthermore, thanks to the differential impedance-matched design, our detectors exhibit delay-line imaging capabilities and photon-number resolution. The properties and high-performance metrics achieved by our system make it a versatile photon-detection solution for many scientific applications.
△ Less
Submitted 17 August, 2021;
originally announced August 2021.
-
A Constraint on Primordial $B$-Modes from the First Flight of the SPIDER Balloon-Borne Telescope
Authors:
SPIDER Collaboration,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
R. Gualtieri,
J. E. Gudmundsson
, et al. (46 additional authors not shown)
Abstract:
We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, an experiment designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. Results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency test…
▽ More
We present the first linear polarization measurements from the 2015 long-duration balloon flight of SPIDER, an experiment designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. Results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency tests on these data. While the polarized CMB anisotropy from primordial density perturbations is the dominant signal in this region of sky, Galactic dust emission is also detected with high significance; Galactic synchrotron emission is found to be negligible in the SPIDER bands. We employ two independent foreground-removal techniques in order to explore the sensitivity of the cosmological result to the assumptions made by each. The primary method uses a dust template derived from Planck data to subtract the Galactic dust signal. A second approach, employing a joint analysis of SPIDER and Planck data in the harmonic domain, assumes a modified-blackbody model for the spectral energy distribution of the dust with no constraint on its spatial morphology. Using a likelihood that jointly samples the template amplitude and $r$ parameter space, we derive 95% upper limits on the primordial tensor-to-scalar ratio from Feldman-Cousins and Bayesian constructions, finding $r<0.11$ and $r<0.19$, respectively. Roughly half the uncertainty in $r$ derives from noise associated with the template subtraction. New data at 280 GHz from SPIDER's second flight will complement the Planck polarization maps, providing powerful measurements of the polarized Galactic dust emission.
△ Less
Submitted 24 March, 2021;
originally announced March 2021.
-
Design and pre-flight performance of SPIDER 280 GHz receivers
Authors:
E. C. Shaw,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. Austermann,
J. Beall,
D. T. Becker,
S. J. Benton,
A. S. Bergman,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S. Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway
, et al. (57 additional authors not shown)
Abstract:
In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for th…
▽ More
In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.
△ Less
Submitted 22 December, 2020;
originally announced December 2020.
-
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Authors:
B. Osherson,
J. P. Filippini,
J. Fu,
R. V. Gramillano,
R. Gualtieri,
E. C. Shaw,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
J. E. Gudmundsson,
M. Halpern,
J. Hartley,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (23 additional authors not shown)
Abstract:
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers…
▽ More
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
SPIDER: CMB polarimetry from the edge of space
Authors:
R. Gualtieri,
J. P. Filippini,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Doré,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
R. V. Gramillano,
J. E. Gudmundsson
, et al. (39 additional authors not shown)
Abstract:
SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. SPIDER targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on map** a large sky area with high fidelity at multiple frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015 deployed a total…
▽ More
SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. SPIDER targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on map** a large sky area with high fidelity at multiple frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled Transition Edge Sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the SPIDER instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. SPIDER's second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
A New Limit on CMB Circular Polarization from SPIDER
Authors:
J. M. Nagy,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
A. S. Bergman,
R. Bihary,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel,
N. N. Gandilo,
K. Ganga,
J. E. Gudmundsson,
M. Halpern
, et al. (36 additional authors not shown)
Abstract:
We present a new upper limit on CMB circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the non-zero circular-to-linear polariz…
▽ More
We present a new upper limit on CMB circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the non-zero circular-to-linear polarization coupling of the HWP polarization modulators, data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes $V$ at 95 and 150 GHz from $33<\ell<307$. No other limits exist over this full range of angular scales, and SPIDER improves upon the previous limit by several orders of magnitude, providing 95% C.L. constraints on $\ell (\ell+1)C_{\ell}^{VV}/(2π)$ ranging from 141 $μK ^2$ to 255 $μK ^2$ at 150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments become increasingly sensitive, the techniques described in this paper can be applied to obtain even stronger constraints on circular polarization.
△ Less
Submitted 11 August, 2017; v1 submitted 1 April, 2017;
originally announced April 2017.
-
A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument
Authors:
Sean Bryan,
Peter Ade,
Mandana Amiri,
Steven Benton,
Richard Bihary,
James Bock,
J. Richard Bond,
H. Cynthia Chiang,
Carlo Contaldi,
Brendan Crill,
Olivier Dore,
Benjamin Elder,
Jeffrey Filippini,
Aurelien Fraisse,
Anne Gambrel,
Natalie Gandilo,
Jon Gudmundsson,
Matthew Hasselfield,
Mark Halpern,
Gene Hilton,
Warren Holmes,
Viktor Hristov,
Kent Irwin,
William Jones,
Zigmund Kermish
, et al. (25 additional authors not shown)
Abstract:
We describe the cryogenic half-wave plate rotation mechanisms built for and used in Spider, a polarization-sensitive balloon-borne telescope array that observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a stratospheric balloon flight from Antarctica in January 2015. The mechanisms operate at liquid helium temperature in flight. A three-point contact design keeps the mechanical b…
▽ More
We describe the cryogenic half-wave plate rotation mechanisms built for and used in Spider, a polarization-sensitive balloon-borne telescope array that observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a stratospheric balloon flight from Antarctica in January 2015. The mechanisms operate at liquid helium temperature in flight. A three-point contact design keeps the mechanical bearings relatively small but allows for a large (305 mm) diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows for precise positioning and prevents undesired rotation when the motors are depowered. A custom-built optical encoder system monitors the bearing angle to an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider during its successful 16 day flight.
△ Less
Submitted 8 January, 2016; v1 submitted 6 October, 2015;
originally announced October 2015.
-
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
J. P. Filippini,
A. A. Fraisse,
A. Gambrel,
N. N. Gandilo,
M. Hasselfield,
M. Halpern,
G. C. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin,
W. C. Jones,
Z. Kermish,
C. J. MacTavish,
P. V. Mason
, et al. (18 additional authors not shown)
Abstract:
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he…
▽ More
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
△ Less
Submitted 11 September, 2015; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Authors:
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
D. Barkats,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
I. Buder,
E. Bullock,
G. Chattopadhyay,
G. Davis,
P. K. Day,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
S. R. Hildebrandt,
G. C. Hilton,
V. Hristov,
H. Hui
, et al. (42 additional authors not shown)
Abstract:
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays…
▽ More
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at 95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ~0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the SPIDER instrument, and development of this technology is ongoing.
△ Less
Submitted 2 February, 2015;
originally announced February 2015.
-
Pre-flight integration and characterization of the SPIDER balloon-borne telescope
Authors:
A. S. Rahlin,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. F. Hasselfield,
G. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (23 additional authors not shown)
Abstract:
We present the results of integration and characterization of the SPIDER instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne polarimeter designed to probe the primordial gravitational wave signal in the degree-scale $B$-mode polarization of the cosmic microwave background. With six independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz frequency bands, SP…
▽ More
We present the results of integration and characterization of the SPIDER instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne polarimeter designed to probe the primordial gravitational wave signal in the degree-scale $B$-mode polarization of the cosmic microwave background. With six independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz frequency bands, SPIDER will map 7.5% of the sky with a depth of 11 to 14 $μ$K$\cdot$arcmin at each frequency, which is a factor of $\sim$5 improvement over Planck. We discuss the integration of the pointing, cryogenic, electronics, and power sub-systems, as well as pre-flight characterization of the detectors and optical systems. SPIDER is well prepared for a December 2014 flight from Antarctica, and is expected to be limited by astrophysical foreground emission, and not instrumental sensitivity, over the survey region.
△ Less
Submitted 9 July, 2014;
originally announced July 2014.
-
Attitude determination for balloon-borne experiments
Authors:
N. N. Gandilo,
P. A. R. Ade,
M. Amiri,
F. E. Angile,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
M. J. Devlin,
B. Dober,
O. P. Dore,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
Y. Fukui,
N. Galitzki,
A. E. Gambrel,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield
, et al. (42 additional authors not shown)
Abstract:
An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitu…
▽ More
An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol flights from McMurdo Station, Antarctica, the system demonstrated an accuracy of <5' rms in-flight, and <5" rms post-flight.
△ Less
Submitted 15 July, 2014; v1 submitted 7 July, 2014;
originally announced July 2014.
-
BLASTbus electronics: general-purpose readout and control for balloon-borne experiments
Authors:
S. J. Benton,
P. A. Ade,
M. Amiri,
F. E. Angilè,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
M. J. Devlin,
B. Dober,
O. P. Doré,
C. D. Dowell,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
Y. Fukui,
N. Galitzki,
A. E. Gambrel,
N. N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Halpern
, et al. (44 additional authors not shown)
Abstract:
We present the second generation BLASTbus electronics. The primary purposes of this system are detector readout, attitude control, and cryogenic housekee**, for balloon-borne telescopes. Readout of neutron transmutation doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition of hundreds of analog signals. Controlling a telescope's attitude requires the capability to inter…
▽ More
We present the second generation BLASTbus electronics. The primary purposes of this system are detector readout, attitude control, and cryogenic housekee**, for balloon-borne telescopes. Readout of neutron transmutation doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition of hundreds of analog signals. Controlling a telescope's attitude requires the capability to interface to a wide variety of sensors and motors, and to use them together in a fast, closed loop. To achieve these different goals, the BLASTbus system employs a flexible motherboard-daughterboard architecture. The programmable motherboard features a digital signal processor (DSP) and field-programmable gate array (FPGA), as well as slots for three daughterboards. The daughterboards provide the interface to the outside world, with versions for analog to digital conversion, and optoisolated digital input/output. With the versatility afforded by this design, the BLASTbus also finds uses in cryogenic, thermometry, and power systems. For accurate timing control to tie everything together, the system operates in a fully synchronous manner. BLASTbus electronics have been successfully deployed to the South Pole, and flown on stratospheric balloons.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Authors:
J. D. Soler,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
C. Chiang,
C. C. Contaldi,
B. P. Crill,
O. P. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (22 additional authors not shown)
Abstract:
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in…
▽ More
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Pointing control for the SPIDER balloon-borne telescope
Authors:
Jamil A. Shariff,
Peter A. R. Ade,
Mandana Amiri,
Steven J. Benton,
Jamie J. Bock,
J. Richard Bond,
Sean A. Bryan,
H. Cynthia Chiang,
Carlo R. Contaldi,
Brendan P. Crill,
Olivier P. Doré,
Marzieh Farhang,
Jeffrey P. Filippini,
Laura M. Fissel,
Aurelien A. Fraisse,
Anne E. Gambrel,
Natalie N. Gandilo,
Sunil R. Golwala,
Jon E. Gudmundsson,
Mark Halpern,
Matthew Hasselfield,
Gene C. Hilton,
Warren A. Holmes,
Viktor V. Hristov,
Kent D. Irwin
, et al. (23 additional authors not shown)
Abstract:
We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI…
▽ More
We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Antenna-coupled TES bolometers for the Keck Array, Spider, and Polar-1
Authors:
R. O'Brient,
P. A. R. Ade,
Z. Ahmed,
R. W. Aikin,
M. Amiri,
S. Benton,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Davis,
P. Day,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
J. Grayson,
M. Halpern,
M. Hasselfield,
G. Hilton,
V. V. Hristov,
H. Hui,
K. Irwin
, et al. (28 additional authors not shown)
Abstract:
Between the BICEP2 and Keck Array experiments, we have deployed over 1500 dual polarized antenna coupled bolometers to map the Cosmic Microwave Background's polarization. We have been able to rapidly deploy these detectors because they are completely planar with an integrated phased-array antenna. Through our experience in these experiments, we have learned of several challenges with this technolo…
▽ More
Between the BICEP2 and Keck Array experiments, we have deployed over 1500 dual polarized antenna coupled bolometers to map the Cosmic Microwave Background's polarization. We have been able to rapidly deploy these detectors because they are completely planar with an integrated phased-array antenna. Through our experience in these experiments, we have learned of several challenges with this technology- specifically the beam synthesis in the antenna- and in this paper we report on how we have modified our designs to mitigate these challenges. In particular, we discus differential steering errors between the polarization pairs' beam centroids due to microstrip cross talk and gradients of penetration depth in the niobium thin films of our millimeter wave circuits. We also discuss how we have suppressed side lobe response with a Gaussian taper of our antenna illumination pattern. These improvements will be used in Spider, Polar-1, and this season's retrofit of Keck Array.
△ Less
Submitted 6 August, 2012;
originally announced August 2012.
-
Optimization and sensitivity of the Keck Array
Authors:
S. Kernasovskiy,
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
S. Benton,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Davis,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. Hiltion,
V. V. Hristov,
K. Irwin,
J. M. Kovac,
C. L. Kuo,
E. Leitch,
M. Lueker
, et al. (19 additional authors not shown)
Abstract:
The Keck Array (SPUD) began observing the cosmic microwave background's polarization in the winter of 2011 at the South Pole. The Keck Array follows the success of the predecessor experiments Bicep and Bicep2, using five on-axis refracting telescopes. These have a combined imaging array of 2500 antenna-coupled TES bolometers read with a SQUID-based time domain multiplexing system. We will discuss…
▽ More
The Keck Array (SPUD) began observing the cosmic microwave background's polarization in the winter of 2011 at the South Pole. The Keck Array follows the success of the predecessor experiments Bicep and Bicep2, using five on-axis refracting telescopes. These have a combined imaging array of 2500 antenna-coupled TES bolometers read with a SQUID-based time domain multiplexing system. We will discuss the detector noise and the optimization of the readout. The achieved sensitivity of the Keck Array is 11.5 μK_(CMB)*sqrt{s} in the 2012 configuration.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
Optical Characterization of the Keck Array Polarimeter at the South Pole
Authors:
A. G. Vieregg,
P. A. R. Ade,
R. Aikin,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
K. J. Bradford,
J. A. Brevik,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. S. Gordon,
M. Halpern,
G. Hilton,
V. V. Hristov,
K. Irwin,
S. Kernasovskiy,
J. M. Kovac,
C. L. Kuo,
E. Leitch,
M. Lueker,
T. Montroy,
C. B. Netterfield
, et al. (15 additional authors not shown)
Abstract:
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full f…
▽ More
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full five-receiver array. All five receivers are currently observing at 150 GHz. The Keck Array employs the field-proven BICEP/BICEP2 strategy of using small, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. We describe our efforts to characterize the main beam shape and beam shape mismatch between co-located orthogonally-polarized detector pairs, and discuss the implications of measured differential beam parameters on temperature to polarization leakage in CMB analysis.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
BICEP2 and Keck Array operational overview and status of observations
Authors:
R. W. Ogburn IV,
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
S. J. Benton,
C. A. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
E. Bullock,
B. Burger,
G. Davis,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. Fliescher,
S. R. Golwala,
M. Gordon,
M. Halpern,
M. Hasselfield,
G. Hilton,
V. V. Hristov,
H. Hui,
K. Irwin,
J. P. Kaufman
, et al. (28 additional authors not shown)
Abstract:
The BICEP2 and Keck Array experiments are designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 2-4 degrees (l=50-100). This is the region in which the B-mode signal, a signature prediction of cosmic inflation, is expected to peak. BICEP2 was deployed to the South Pole at the end of 2009 and is in the middle of its third year of observing with 500 polar…
▽ More
The BICEP2 and Keck Array experiments are designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 2-4 degrees (l=50-100). This is the region in which the B-mode signal, a signature prediction of cosmic inflation, is expected to peak. BICEP2 was deployed to the South Pole at the end of 2009 and is in the middle of its third year of observing with 500 polarization-sensitive detectors at 150 GHz. The Keck Array was deployed to the South Pole at the end of 2010, initially with three receivers--each similar to BICEP2. An additional two receivers have been added during the 2011-12 summer. We give an overview of the two experiments, report on substantial gains in the sensitivity of the two experiments after post-deployment optimization, and show preliminary maps of CMB polarization from BICEP2.
△ Less
Submitted 2 August, 2012;
originally announced August 2012.
-
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Authors:
A. A. Fraisse,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. Bryan,
B. Burger,
H. C. Chiang,
C. N. Clark,
C. R. Contaldi,
B. P. Crill,
G. Davis,
O. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (21 additional authors not shown)
Abstract:
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrum…
▽ More
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrument is significantly below the amplitude of an interesting cosmological signal with r=0.03. We present a scanning strategy that enables us to minimize uncertainty in the reconstruction of the Stokes parameters used to characterize the CMB, while accessing a relatively wide range of angular scales. Evaluating the amplitude of the polarized Galactic emission in the SPIDER field, we conclude that the polarized emission from interstellar dust is as bright or brighter than the cosmological signal at all SPIDER frequencies (90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the "Southern Hole." We show that two ~20-day flights of the SPIDER instrument can constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when foreground contamination is taken into account. In the absence of foregrounds, the same limit can be reached after one 20-day flight.
△ Less
Submitted 2 May, 2013; v1 submitted 15 June, 2011;
originally announced June 2011.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Design and performance of the Spider instrument
Authors:
M. C. Runyan,
P. A. R. Ade,
M. Amiri,
S. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Dore,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. Fissel,
N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
M. Halpern,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (18 additional authors not shown)
Abstract:
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architectu…
▽ More
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architecture, and magnetic shielding of the TES sensors and SQUID multiplexer. We also describe the optical, noise, and magnetic shielding performance of the 145 GHz prototype instrument insert.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Authors:
J. P. Filippini,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
B. Burger,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
M. Farhang,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (19 additional authors not shown)
Abstract:
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 28…
▽ More
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope modulates the polarization of incoming light to control systematics. Spider's first flight will be a 20-30-day Antarctic balloon campaign in December 2011. This flight will map \sim8% of the sky to achieve unprecedented sensitivity to the polarization signature of the gravitational wave background predicted by inflationary cosmology. The Spider mission will also serve as a proving ground for these detector technologies in preparation for a future satellite mission.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
The Keck Array: a pulse tube cooled CMB polarimeter
Authors:
C. D. Sheehy,
P. A. R. Ade,
R. W. Aikin,
M. Amiri,
S. Benton,
C. Bischoff,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
C. D. Dowell,
L. Duband,
J. P. Filippini,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. Hilton,
V. V. Hristov,
K. Irwin,
J. P. Kaufman,
B. G. Keating,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
E. M. Leitch
, et al. (19 additional authors not shown)
Abstract:
The Keck Array is a cosmic microwave background (CMB) polarimeter that will begin observing from the South Pole in late 2010. The initial deployment will consist of three telescopes similar to BICEP2 housed in ultra-compact, pulse tube cooled cryostats. Two more receivers will be added the following year. In these proceedings we report on the design and performance of the Keck cryostat. We also re…
▽ More
The Keck Array is a cosmic microwave background (CMB) polarimeter that will begin observing from the South Pole in late 2010. The initial deployment will consist of three telescopes similar to BICEP2 housed in ultra-compact, pulse tube cooled cryostats. Two more receivers will be added the following year. In these proceedings we report on the design and performance of the Keck cryostat. We also report some initial results on the performance of antenna-coupled TES detectors operating in the presence of a pulse tube. We find that the performance of the detectors is not seriously impacted by the replacement of BICEP2's liquid helium cryostat with a pulse tube cooled cryostat.
△ Less
Submitted 28 April, 2011;
originally announced April 2011.
-
Spider Optimization II: Optical, Magnetic and Foreground Effects
Authors:
D. T. O'Dea,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. Bryan,
B. Burger,
H. C. Chiang,
C. N. Clark,
C. R. Contaldi,
B. P. Crill,
G. Davis,
O. Dore,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Hasselfield,
G. Hilton,
W. Holmes
, et al. (21 additional authors not shown)
Abstract:
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental s…
▽ More
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental systematic errors must be controlled with unprecedented accuracy. Here, we build on previous work to use simulations of Spider observations to examine the impact of several systematic effects that have been characterized through testing and modeling of various instrument components. In particular, we investigate the impact of the non-ideal spectral response of the half-wave plates, coupling between focal plane components and the Earth's magnetic field, and beam mismatches and asymmetries. We also present a model of diffuse polarized foreground emission based on a three-dimensional model of the Galactic magnetic field and dust, and study the interaction of this foreground emission with our observation strategy and instrumental effects. We find that the expected level of foreground and systematic contamination is sufficiently low for Spider to achieve its science goals.
△ Less
Submitted 2 February, 2011;
originally announced February 2011.
-
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Authors:
A. Orlando,
R. W Aikin,
M. Amiri,
J. J. Bock,
J. A. Bonetti,
J. A. Brevik,
B. Burger,
G. Chattopadthyay,
P. K. Day,
J. P. Filippini,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
K. D. Irwin,
M. Kenyon,
J. M. Kovac,
C. L. Kuo,
A. E. Lange,
H. G. LeDuc,
N. Llombart,
H. T. Nguyen,
R. W. Ogburn,
C. D. Reintsema,
M. C. Runyan
, et al. (6 additional authors not shown)
Abstract:
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled t…
▽ More
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters targeting the B-mode polarization induced by primordial gravitational waves from inflation. They will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220 GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays are assembled together to make a focal plane, for a total of 256 dual-polarization elements (512 TES sensors). The detector arrays are integrated with a time-domain SQUID multiplexer developed at NIST and read out using the multi-channels electronics (MCE) developed at the University of British Columbia. Following our progress in improving detector parameters uniformity across the arrays and fabrication yield, our main effort has focused on improving detector arrays optical and noise performances, in order to produce science grade focal planes achieving target sensitivities. We report on changes in detector design implemented to optimize such performances and following focal plane arrays characterization. BICEP2 has deployed a first 150 GHz science grade focal plane to the South Pole in December 2009.
△ Less
Submitted 19 September, 2010;
originally announced September 2010.
-
Modeling and characterization of the SPIDER half-wave plate
Authors:
Sean A. Bryan,
Peter A. R. Ade,
Mandana Amiri,
Steve Benton,
Richard Bihary,
James J. Bock,
J. Richard Bond,
Joseph A. Bonetti,
H. Cynthia Chiang,
Carlo R. Contaldi,
Brendan P. Crill,
Daniel O'Dea,
Olivier Dore,
Marzieh Farhang,
Jeffrey P. Filippini,
Laura Fissel,
Natalie Gandilo,
Sunil Golwala,
Jon E. Gudmundsson,
Matthew Hasselfield,
Mark Halpern,
Kyle R. Helson,
Gene Hilton,
Warren Holmes,
Viktor V. Hristov
, et al. (20 additional authors not shown)
Abstract:
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave t…
▽ More
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave transmission spectra of the sapphire at room and cryogenic temperatures. The spectra are consistent with our physical optics model, and the data gives excellent measurements of the indices of A-cut sapphire. We have also taken preliminary spectra of the integrated HWP, optical system, and detectors in the prototype Spider receiver. We calculate the variation in response of the HWP between observing the CMB and foreground spectra, and estimate that it should not limit the Spider constraints on inflation.
△ Less
Submitted 19 June, 2010;
originally announced June 2010.
-
SPIDER: A Balloon-borne Large-scale CMB Polarimeter
Authors:
B. P. Crill,
P. A. R. Ade,
E. S. Battistelli,
S. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. Brevik,
S. Bryan,
C. R. Contaldi,
O. Dore,
M. Farhang,
L. Fissel,
S. R. Golwala,
M. Halpern,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. Irwin,
W. C. Jones,
C. L. Kuo,
A. E. Lange,
C. Lawrie,
C. J. MacTavish,
T. G. Martin
, et al. (12 additional authors not shown)
Abstract:
Spider is a balloon-borne experiment that will measure the polarization of the Cosmic Microwave Background over a large fraction of a sky at 1 degree resolution. Six monochromatic refracting millimeter-wave telescopes with large arrays of antenna-coupled transition-edge superconducting bolometers will provide system sensitivities of 4.2 and 3.1 micro K_cmb rt s at 100 and 150 GHz, respectively.…
▽ More
Spider is a balloon-borne experiment that will measure the polarization of the Cosmic Microwave Background over a large fraction of a sky at 1 degree resolution. Six monochromatic refracting millimeter-wave telescopes with large arrays of antenna-coupled transition-edge superconducting bolometers will provide system sensitivities of 4.2 and 3.1 micro K_cmb rt s at 100 and 150 GHz, respectively. A rotating half-wave plate will modulate the polarization sensitivity of each telescope, controlling systematics. Bolometer arrays operating at 225 GHz and 275 GHz will allow removal of polarized galactic foregrounds. In a 2-6 day first flight from Alice Springs, Australia in 2010, Spider will map 50% of the sky to a depth necessary to improve our knowledge of the reionization optical depth by a large factor.
△ Less
Submitted 9 July, 2008;
originally announced July 2008.
-
Thermal Conductivity of Thermally-Isolating Polymeric and Composite Structural Support Materials Between 0.3 and 4 K
Authors:
M. C. Runyan,
W. C. Jones
Abstract:
We present measurements of the low-temperature thermal conductivity of a number of polymeric and composite materials from 0.3 to 4 K. The materials measured are Vespel SP-1, Vespel SP-22, unfilled PEEK, 30% carbon fiber-filled PEEK, 30% glass-filled PEEK, carbon fiber Graphlite composite rod, Torlon 4301, G-10/FR-4 fiberglass, pultruded fiberglass composite, Macor ceramic, and graphite rod. Thes…
▽ More
We present measurements of the low-temperature thermal conductivity of a number of polymeric and composite materials from 0.3 to 4 K. The materials measured are Vespel SP-1, Vespel SP-22, unfilled PEEK, 30% carbon fiber-filled PEEK, 30% glass-filled PEEK, carbon fiber Graphlite composite rod, Torlon 4301, G-10/FR-4 fiberglass, pultruded fiberglass composite, Macor ceramic, and graphite rod. These materials have moderate to high elastic moduli making them useful for thermally-isolating structural supports.
△ Less
Submitted 11 June, 2008;
originally announced June 2008.
-
High resolution CMB power spectrum from the complete ACBAR data set
Authors:
C. L. Reichardt,
P. A. R. Ade,
J. J. Bock,
J. R. Bond,
J. A. Brevik,
C. R. Contaldi,
M. D. Daub,
J. T. Dempsey,
J. H. Goldstein,
W. L. Holzapfel,
C. L. Kuo,
A. E. Lange,
M. Lueker,
M. Newcomb,
J. B. Peterson,
J. Ruhl,
M. C. Runyan,
Z. Staniszewski
Abstract:
In this paper, we present results from the complete set of cosmic microwave background (CMB) radiation temperature anisotropy observations made with the Arcminute Cosmology Bolometer Array Receiver (ACBAR) operating at 150 GHz. We include new data from the final 2005 observing season, expanding the number of detector-hours by 210% and the sky coverage by 490% over that used for the previous ACBA…
▽ More
In this paper, we present results from the complete set of cosmic microwave background (CMB) radiation temperature anisotropy observations made with the Arcminute Cosmology Bolometer Array Receiver (ACBAR) operating at 150 GHz. We include new data from the final 2005 observing season, expanding the number of detector-hours by 210% and the sky coverage by 490% over that used for the previous ACBAR release. As a result, the band-power uncertainties have been reduced by more than a factor of two on angular scales encompassing the third to fifth acoustic peaks as well as the dam** tail of the CMB power spectrum. The calibration uncertainty has been reduced from 6% to 2.1% in temperature through a direct comparison of the CMB anisotropy measured by ACBAR with that of the dipole-calibrated WMAP5 experiment. The measured power spectrum is consistent with a spatially flat, LambdaCDM cosmological model. We include the effects of weak lensing in the power spectrum model computations and find that this significantly improves the fits of the models to the combined ACBAR+WMAP5 power spectrum. The preferred strength of the lensing is consistent with theoretical expectations. On fine angular scales, there is weak evidence (1.1 sigma) for excess power above the level expected from primary anisotropies. We expect any excess power to be dominated by the combination of emission from dusty protogalaxies and the Sunyaev-Zel'dovich effect (SZE). However, the excess observed by ACBAR is significantly smaller than the excess power at ell > 2000 reported by the CBI experiment operating at 30 GHz. Therefore, while it is unlikely that the CBI excess has a primordial origin; the combined ACBAR and CBI results are consistent with the source of the CBI excess being either the SZE or radio source contamination.
△ Less
Submitted 6 November, 2008; v1 submitted 9 January, 2008;
originally announced January 2008.
-
Improved Measurements of the CMB Power Spectrum with ACBAR
Authors:
C. L. Kuo,
P. A. R. Ade,
J. J. Bock,
J. R. Bond,
C. R. Contaldi,
M. D. Daub,
J. H. Goldstein,
W. L. Holzapfel,
A. E. Lange,
M. Lueker,
M. Newcomb,
J. B. Peterson,
C. Reichardt,
J. Ruhl,
M. C. Runyan,
Z. Staniszweski
Abstract:
We report improved measurements of temperature anisotropies in the cosmic microwave background (CMB) radiation made with the Arcminute Cosmology Bolometer Array Receiver (ACBAR). In this paper, we use a new analysis technique and include 30% more data from the 2001 and 2002 observing seasons than the first release to derive a new set of band-power measurements with significantly smaller uncertai…
▽ More
We report improved measurements of temperature anisotropies in the cosmic microwave background (CMB) radiation made with the Arcminute Cosmology Bolometer Array Receiver (ACBAR). In this paper, we use a new analysis technique and include 30% more data from the 2001 and 2002 observing seasons than the first release to derive a new set of band-power measurements with significantly smaller uncertainties. The planet-based calibration used previously has been replaced by comparing the flux of RCW38 as measured by ACBAR and BOOMERANG to transfer the WMAP-based BOOMERANG calibration to ACBAR. The resulting power spectrum is consistent with the theoretical predictions for a spatially flat, dark energy dominated LCDM cosmology including the effects of gravitational lensing. Despite the exponential dam** on small angular scales, the primary CMB fluctuations are detected with a signal-to-noise ratio of greater than 4 up to multipoles of l=2000. This increase in the precision of the fine-scale CMB power spectrum leads to only a modest decrease in the uncertainties on the parameters of the standard cosmological model. At high angular resolution, secondary anisotropies are predicted to be a significant contribution to the measured anisotropy. A joint analysis of the ACBAR results at 150 GHz and the CBI results at 30 GHz in the multipole range 2000 < l < 3000 shows that the power, reported by CBI in excess of the predicted primary anisotropy, has a frequency spectrum consistent with the thermal Sunyaev-Zel'dovich effect and inconsistent with primary CMB. The results reported here are derived from a subset of the total ACBAR data set; the final ACBAR power spectrum at 150 GHz will include 3.7 times more effective integration time and 6.5 times more sky coverage than is used here.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
Observations of High-Redshift X-Ray Selected Clusters with the Sunyaev-Zel'dovich Array
Authors:
Stephen Muchovej,
John E. Carlstrom,
John Cartwright,
Christopher Greer,
David Hawkins,
Ryan Hennessy,
Marshall Joy,
James W. Lamb,
Erik M. Leitch,
Michael Loh,
Amber D. Miller,
Tony Mroczkowski,
Clem Pryke,
Ben Reddall,
Marcus Runyan,
Matthew Sharp,
David Wood
Abstract:
We report measurements of the Sunyaev-Zel'dovich (SZ) effect in three high-redshift (0.89 < z < 1.03), X-ray selected galaxy clusters. The observations were obtained at 30 GHz during the commissioning period of a new, eight-element interferometer -- the Sunyaev-Zel'dovich Array (SZA) -- built for dedicated SZ effect observations. The SZA observations are sensitive to angular scales larger than t…
▽ More
We report measurements of the Sunyaev-Zel'dovich (SZ) effect in three high-redshift (0.89 < z < 1.03), X-ray selected galaxy clusters. The observations were obtained at 30 GHz during the commissioning period of a new, eight-element interferometer -- the Sunyaev-Zel'dovich Array (SZA) -- built for dedicated SZ effect observations. The SZA observations are sensitive to angular scales larger than those subtended by the virial radii of the clusters. Assuming isothermality and hydrostatic equilibrium for the intracluster medium, and gas-mass fractions consistent with those for clusters at moderate redshift, we calculate electron temperatures, gas masses, and total cluster masses from the SZ data. The SZ-derived masses, integrated approximately to the virial radii, are 1.9 ^{+0.5}_{-0.4}x10^{14} solar masses for CLl1415.1+3612, 3.4^{+0.6}_{-0.5}x10^{14} solar masses for CL1429.0+4241, and 7.2^{+1.3}_{-0.9}x10^{14} solar masses for CL1226.9+3332. The SZ-derived quantities are in good agreement with the cluster properties derived from X-ray measurements.
△ Less
Submitted 4 October, 2006;
originally announced October 2006.
-
The South Pole Telescope
Authors:
SPT Collaboration,
J. E. Ruhl,
P. A. R. Ade,
J. E. Carlstrom,
H. M. Cho,
T. Crawford,
M. Dobbs,
C. H. Greer,
N. W. Halverson,
W. L. Holzapfel,
T. M. Lantin,
A. T. Lee,
J. Leong,
E. M. Leitch,
W. Lu,
M. Lueker,
J. Mehl,
S. S. Meyer,
J. J. Mohr,
S. Padin,
T. Plagge,
C. Pryke,
D. Schwan,
M. K. Sharp,
M. C. Runyan
, et al. (3 additional authors not shown)
Abstract:
A new 10 meter diameter telescope is being constructed for deployment at the NSF South Pole research station. The telescope is designed for conducting large-area millimeter and sub-millimeter wave surveys of faint, low contrast emission, as required to map primary and secondary anisotropies in the cosmic microwave background. To achieve the required sensitivity and resolution, the telescope desi…
▽ More
A new 10 meter diameter telescope is being constructed for deployment at the NSF South Pole research station. The telescope is designed for conducting large-area millimeter and sub-millimeter wave surveys of faint, low contrast emission, as required to map primary and secondary anisotropies in the cosmic microwave background. To achieve the required sensitivity and resolution, the telescope design employs an off-axis primary with a 10m diameter clear aperture. The full aperture and the associated optics will have a combined surface accuracy of better than 20 microns rms to allow precision operation in the submillimeter atmospheric windows. The telescope will be surrounded with a large reflecting ground screen to reduce sensitivity to thermal emission from the ground and local interference. The optics of the telescope will support a square degree field of view at 2mm wavelength and will feed a new 1000-element micro-lithographed planar bolometric array with superconducting transition-edge sensors and frequency-multiplexed readouts. The first key project will be to conduct a survey over approximately 4000 degrees for galaxy clusters using the Sunyaev-Zel'dovich Effect. This survey should find many thousands of clusters with a mass selection criteria that is remarkably uniform with redshift. Armed with redshifts obtained from optical and infrared follow-up observations, it is expected that the survey will enable significant constraints to be placed on the equation of state of the dark energy.
△ Less
Submitted 4 November, 2004;
originally announced November 2004.
-
Sunyaev-Zeldovich Observations of Massive Clusters of Galaxies
Authors:
P. Gomez,
A. K. Romer,
J. B. Peterson,
W. Chase,
M. Runyan,
W. Holzapfel,
C. L. Kuo,
M. Newcomb,
J. Ruhl,
J. Goldstein,
A. Lange,
.
Abstract:
We present detections of the Sunyaev-Zeldovich Effect (SZE) at 150GHz and 275GHz for the X-ray luminous z=0.299 cluster 1E0657-67. These observations were obtained as part of an X-ray, weak lensing, and SZE survey of nearby X-ray bright clusters. The SZE maps were made with the ACBAR (150, 210, 275 GHz) bolometer array installed at the Viper telescope located at the South Pole. We also present p…
▽ More
We present detections of the Sunyaev-Zeldovich Effect (SZE) at 150GHz and 275GHz for the X-ray luminous z=0.299 cluster 1E0657-67. These observations were obtained as part of an X-ray, weak lensing, and SZE survey of nearby X-ray bright clusters. The SZE maps were made with the ACBAR (150, 210, 275 GHz) bolometer array installed at the Viper telescope located at the South Pole. We also present preliminary results from a blind SZE cluster survey.
△ Less
Submitted 11 November, 2003;
originally announced November 2003.
-
Imaging the Sunyaev Zel'dovich Effect using ACBAR on Viper
Authors:
A. K. Romer,
P. L. Gomez,
C. M. Cantalupo,
M. D. Daub,
J. H. Goldstein,
W. L. Holzapfel,
C. L. Kuo,
A. E. Lange,
M. Lueker,
M. Newcomb,
J. B. Peterson,
J. E. Ruhl,
M. C. Runyan,
E. Torbet,
C. Reichardt,
.
Abstract:
During 2001 and 2002, observations of several X-ray bright clusters of galaxies were conducted using the ACBAR Bolometer Array on the South Pole Viper telescope. A multi-frequency analysis of these clusters is currently underway. This multi-frequency analysis includes 150, 220 and 275 GHz data from ACBAR, X-ray imaging and spectroscopy from Chandra and XMM-Newton, and weak lensing data from the…
▽ More
During 2001 and 2002, observations of several X-ray bright clusters of galaxies were conducted using the ACBAR Bolometer Array on the South Pole Viper telescope. A multi-frequency analysis of these clusters is currently underway. This multi-frequency analysis includes 150, 220 and 275 GHz data from ACBAR, X-ray imaging and spectroscopy from Chandra and XMM-Newton, and weak lensing data from the CTIO 4m Blanco telescope. We describe here how ACBAR can be used to create fully sampled cluster images and present such images for four of the clusters in our sample; Abell 3266, Abell 3827, Abell S1063 and 1E0657-56. In these images, the Sunyaev-Zel'dovich Effect is clearly detected.
△ Less
Submitted 11 November, 2003;
originally announced November 2003.
-
First Results from the Arcminute Cosmology Bolometer Array Receiver
Authors:
M. C. Runyan,
P. A. R. Ade,
J. J. Bock,
J. R. Bond,
C. Cantalupo,
C. R. Contaldi,
M. D. Daub,
J. H. Goldstein,
P. L. Gomez,
W. L. Holzapfel,
C. L. Kuo,
A. E. Lange,
M. Lueker,
M. Newcomb,
J. B. Peterson,
D. Pogosyan,
A. K. Romer,
J. Ruhl,
E. Torbet,
D. Woolsey
Abstract:
We review the first science results from the Arcminute Cosmology Bolometer Array Receiver (ACBAR); a multifrequency millimeter-wave receiver optimized for observations of the Cosmic Microwave Background (CMB) and the Sunyaev-Zel'dovich (SZ) effect in clusters of galaxies. ACBAR was installed on the 2 m Viper telescope at the South Pole in January 2001 and the results presented here incorporate d…
▽ More
We review the first science results from the Arcminute Cosmology Bolometer Array Receiver (ACBAR); a multifrequency millimeter-wave receiver optimized for observations of the Cosmic Microwave Background (CMB) and the Sunyaev-Zel'dovich (SZ) effect in clusters of galaxies. ACBAR was installed on the 2 m Viper telescope at the South Pole in January 2001 and the results presented here incorporate data through July 2002. We present the power spectrum of the CMB at 150 GHz over the range \ell = 150 - 3000 measured by ACBAR as well as estimates for the values of the cosmological parameters within the context of Lambda-CDM models. We find that the inclusion of Omega_Lambda greatly improves the fit to the power spectrum. We also observe a slight excess of small-scale anisotropy at 150 GHz; if interpreted as power from the SZ effect of unresolved clusters, the measured signal is consistent with CBI and BIMA within the context of the SZ power spectrum models tested.
△ Less
Submitted 28 May, 2003;
originally announced May 2003.
-
ACBAR: The Arcminute Cosmology Bolometer Array Receiver
Authors:
M. C. Runyan,
P. A. R. Ade,
R. S. Bhatia,
J. J. Bock,
M. D. Daub,
J. H. Goldstein,
C. V. Haynes,
W. L. Holzapfel,
C. L. Kuo,
A. E. Lange,
J. Leong,
M. Lueker,
M. Newcomb,
J. B. Peterson,
J. Ruhl,
G. Sirbi,
E. Torbet,
C. Tucker,
A. D. Turner,
D. Woolsey
Abstract:
We describe the Arcminute Cosmology Bolometer Array Receiver (ACBAR); a multifrequency millimeter-wave receiver designed for observations of the Cosmic Microwave Background (CMB) and the Sunyaev-Zel'dovich effect in clusters of galaxies. The ACBAR focal plane consists of a 16-pixel, background-limited, 240 mK bolometer array that can be configured to observe simultaneously at 150, 220, 280, and…
▽ More
We describe the Arcminute Cosmology Bolometer Array Receiver (ACBAR); a multifrequency millimeter-wave receiver designed for observations of the Cosmic Microwave Background (CMB) and the Sunyaev-Zel'dovich effect in clusters of galaxies. The ACBAR focal plane consists of a 16-pixel, background-limited, 240 mK bolometer array that can be configured to observe simultaneously at 150, 220, 280, and 350 GHz. With 4-5' FWHM Gaussian beam sizes and a 3 degree azimuth chop, ACBAR is sensitive to a wide range of angular scales. ACBAR was installed on the 2 m Viper telescope at the South Pole in January 2001. We describe the design of the instrument and its performance during the 2001 and 2002 observing seasons.
△ Less
Submitted 22 April, 2004; v1 submitted 24 March, 2003;
originally announced March 2003.
-
Peculiar Velocity Limits from Measurements of the Spectrum of the Sunyaev-Zel'dovich Effect in Six Clusters of Galaxies
Authors:
B. A. Benson,
S. E. Church,
P. A. R. Ade,
J. J. Bock,
K. M. Ganga,
J. R. Hinderks,
P. D. Mauskopf,
B. Philhour,
M. C. Runyan,
K. L. Thompson
Abstract:
We have made measurements of the Sunyaev-Zel'dovich (SZ) effect in six galaxy clusters at z > 0.2 using the Sunyaev-Zel'dovich Infrared Experiment (SuZIE II) in three frequency bands between 150 and 350 GHz. Simultaneous multi-frequency measurements have been used to distinguish between thermal and kinematic components of the SZ effect, and to significantly reduce the effects of variations in at…
▽ More
We have made measurements of the Sunyaev-Zel'dovich (SZ) effect in six galaxy clusters at z > 0.2 using the Sunyaev-Zel'dovich Infrared Experiment (SuZIE II) in three frequency bands between 150 and 350 GHz. Simultaneous multi-frequency measurements have been used to distinguish between thermal and kinematic components of the SZ effect, and to significantly reduce the effects of variations in atmospheric emission which can otherwise dominate the noise. We have set limits to the peculiar velocities of each cluster with respect to the Hubble flow, and have used the cluster sample to set a 95% confidence limit of < 1410 km/s to the bulk flow of the intermediate-redshift universe in the direction of the CMB dipole. This is the first time that SZ measurements have been used to constrain bulk flows. We show that systematic uncertainties in peculiar velocity determinations from the SZ effect are likely to be dominated by submillimeter point sources and we discuss the level of this contamination.
△ Less
Submitted 22 March, 2003;
originally announced March 2003.
-
First Results From an X-ray, Weak Lensing, and Sunyaev-Zeldovich Effect Survey of Nearby Clusters: Abell 3266
Authors:
P. L. Gomez,
A. K. Romer,
J. B. Peterson,
C. M. Cantalupo,
S. W. L. Holzapfel,
C. L. Kuo,
M. Newcomb,
J. Ruhl,
J. Goldstein,
E. Torbet,
M. C. Runyan
Abstract:
As part of a combined Sunyaev-Zeldovich Effect (SZE), X-ray and weak lensing survey of low redshift (z<0.1) X-ray clusters, we present SZE images of the z=0.059 X-ray cluster Abell 3266 at three observing frequencies (150, 220, 275 GHz) and after the spectral subtraction of primary Cosmic Microwave Background (CMB) anisotropies. These images were generated using the ACBAR bolometer array operate…
▽ More
As part of a combined Sunyaev-Zeldovich Effect (SZE), X-ray and weak lensing survey of low redshift (z<0.1) X-ray clusters, we present SZE images of the z=0.059 X-ray cluster Abell 3266 at three observing frequencies (150, 220, 275 GHz) and after the spectral subtraction of primary Cosmic Microwave Background (CMB) anisotropies. These images were generated using the ACBAR bolometer array operated on the Viper telescope at the South Pole. The multi-frequency data from ACBAR should allow us to overcome one of the main obstacles facing the analysis of SZE observations of nearby clusters, i.e. contamination from primary Cosmic Microwave Background (CMB) anisotropies.
△ Less
Submitted 2 January, 2003;
originally announced January 2003.
-
Estimates of Cosmological Parameters Using the CMB Angular Power Spectrum of ACBAR
Authors:
J. H. Goldstein,
P. A. R. Ade,
J. J. Bock,
J. R. Bond,
C. Cantalupo,
C. R. Contaldi,
M. D. Daub,
W. L. Holzapfel,
C. Kuo,
A. E. Lange,
M. Lueker,
M. Newcomb,
J. B. Peterson,
D. Pogosyan,
J. E. Ruhl,
M. C. Runyan,
E. Torbet
Abstract:
We report an investigation of cosmological parameters based on the measurements of anisotropy in the cosmic microwave background radiation (CMB) made by ACBAR. We use the ACBAR data in concert with other recent CMB measurements to derive Bayesian estimates of parameters in inflation-motivated adiabatic cold dark matter models. We apply a series of additional cosmological constraints on the shape…
▽ More
We report an investigation of cosmological parameters based on the measurements of anisotropy in the cosmic microwave background radiation (CMB) made by ACBAR. We use the ACBAR data in concert with other recent CMB measurements to derive Bayesian estimates of parameters in inflation-motivated adiabatic cold dark matter models. We apply a series of additional cosmological constraints on the shape and amplitude of the density power spectrum, the Hubble parameter and from supernovae to further refine our parameter estimates. Previous estimates of parameters are confirmed, with sensitive measurements of the power spectrum now ranging from \ell \sim 3 to 2800. Comparing individual best model fits, we find that the addition of Ω_Λas a parameter dramatically improves the fits. We also use the high-\ell data of ACBAR, along with similar data from CBI and BIMA, to investigate potential secondary anisotropies from the Sunyaev-Zeldovich effect. We show that the results from the three experiments are consistent under this interpretation, and use the data, combined and individually, to estimate σ_8 from the Sunyaev-Zeldovich component.
△ Less
Submitted 24 December, 2002; v1 submitted 23 December, 2002;
originally announced December 2002.
-
High Resolution Observations of the CMB Power Spectrum with ACBAR
Authors:
C. L. Kuo,
P. A. R. Ade,
J. J. Bock,
C. Cantalupo,
M. D. Daub,
J. Goldstein,
W. L. Holzapfel,
A. E. Lange,
M. Lueker,
M. Newcomb,
J. B. Peterson,
J. Ruhl,
M. C. Runyan,
E. Torbet
Abstract:
We report the first measurements of anisotropy in the cosmic microwave background (CMB) radiation with the Arcminute Cosmology Bolometer Array Receiver (ACBAR). The instrument was installed on the 2.1m Viper telescope at the South Pole in January 2001; the data presented here are the product of observations up to and including July 2002. The two deep fields presented here, have had offsets remov…
▽ More
We report the first measurements of anisotropy in the cosmic microwave background (CMB) radiation with the Arcminute Cosmology Bolometer Array Receiver (ACBAR). The instrument was installed on the 2.1m Viper telescope at the South Pole in January 2001; the data presented here are the product of observations up to and including July 2002. The two deep fields presented here, have had offsets removed by subtracting lead and trail observations and cover approximately 24 deg^2 of sky selected for low dust contrast. These results represent the highest signal to noise observations of CMB anisotropy to date; in the deepest 150GHz band map, we reached an RMS of 8.0μK per 5' beam. The 3 degree extent of the maps, and small beamsize of the experiment allow the measurement of the CMB anisotropy power spectrum over the range \ell = 150-3000 with resolution of Δ\ell=150. The contributions of galactic dust and radio sources to the observed anisotropy are negligible and are removed in the analysis. The resulting power spectrum is found to be consistent with the primary anisotropy expected in a concordance ΛCDM Universe.
△ Less
Submitted 12 December, 2002;
originally announced December 2002.