-
Liger at Keck Observatory: Imager Detector and IFS Pick-off Mirror Assembly
Authors:
Maren Cosens,
Shelley A. Wright,
Aaron Brown,
Michael Fitzgerald,
Chris Johnson,
Tucker Jones,
Marc Kassis,
Evan Kress,
Renate Kupke,
James E. Larkin,
Kenneth Magnone,
Rosalie McGurk,
Nils-Erik Rundquist,
Ji Man Sohn,
Eric Wang,
James Wiley,
Sherry Yeh
Abstract:
Liger is a next-generation near-infrared imager and integral field spectrograph (IFS) planned for the W.M. Keck Observatory. Liger is designed to take advantage of improved adaptive optics (AO) from the Keck All-Sky Precision Adaptive Optics (KAPA) upgrade currently underway. Liger operates at 0.84-2.45 $μ$m with spectral resolving powers of R$\sim$4,000-10,000. Liger makes use of a sequential ima…
▽ More
Liger is a next-generation near-infrared imager and integral field spectrograph (IFS) planned for the W.M. Keck Observatory. Liger is designed to take advantage of improved adaptive optics (AO) from the Keck All-Sky Precision Adaptive Optics (KAPA) upgrade currently underway. Liger operates at 0.84-2.45 $μ$m with spectral resolving powers of R$\sim$4,000-10,000. Liger makes use of a sequential imager and spectrograph design allowing for simultaneous observations. There are two spectrograph modes: a lenslet with high spatial sampling of 14 and 31 mas, and a slicer with 75 and 150 mas sampling with an expanded field of view. Two pick-off mirrors near the imager detector direct light to these two IFS channels. We present the design and structural analysis for the imager detector and IFS pick-off mirror mounting assembly that will be used to align and maintain stability throughout its operation. A piezoelectric actuator will be used to step through $\rm3\,mm$ of travel during alignment of the instrument to determine the optimal focus for both the detector and pick-off mirrors which will be locked in place during normal operation. We will demonstrate that the design can withstand the required gravitational and ship** loads and can be aligned within the positioning tolerances for the optics.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Liger at Keck Observatory: Design of the Data Reduction System and Software Interfaces
Authors:
Nils Rundquist,
Andrea Zonca,
Arun Surya,
Shelley A. Wright,
Aaron Brown,
Maren Cosens,
Michael Fitzgerald,
Chris Johnson,
Marc Kassis,
Renate Kupke,
Kyle Lanclos,
James E. Larkin,
Kenneth Magnone,
Rosalie McGurk,
Ji Man Sohn,
Gregory Walth,
James Wiley,
Sherry Yeh
Abstract:
Liger is a second generation near-infrared imager and integral field spectrograph (IFS) for the W. M. Keck Observatory that will utilize the capabilities of the Keck All-sky Precision Adaptive-optics (KAPA) system. Liger operates at a wavelength range of 0.81 μm - 2.45 μm and utilizes a slicer and a lenslet array IFS with varying spatial plate scales and fields of view resulting in hundreds of mod…
▽ More
Liger is a second generation near-infrared imager and integral field spectrograph (IFS) for the W. M. Keck Observatory that will utilize the capabilities of the Keck All-sky Precision Adaptive-optics (KAPA) system. Liger operates at a wavelength range of 0.81 μm - 2.45 μm and utilizes a slicer and a lenslet array IFS with varying spatial plate scales and fields of view resulting in hundreds of modes available to the astronomer. Because of the high level of complexity in the raw data formats for the slicer and lenslet IFS modes, Liger must be designed in conjunction with a Data Reduction System (DRS) which will reduce data from the instrument in real-time and deliver science-ready data products to the observer. The DRS will reduce raw imager and IFS frames from the readout system and provide 2D and 3D data products via custom quick-look visualization tools suited to the presentation of IFS data. The DRS will provide the reduced data to the Keck Observatory Archive (KOA) and will be available to astronomers for offline post-processing of observer data. We present an initial design for the DRS and define the interfaces between observatory and instrument software systems.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Liger at Keck Observatory: Design of Imager Optical Assembly and Spectrograph Re-Imaging Optics
Authors:
James Wiley,
Aaron Brown,
Renate Kupke,
Maren Cosens,
Shelley A. Wright,
Michael Fitzgerald,
Chris Johnson,
Tucker Jones,
Marc Kassis,
Evan Kress,
James E. Larkin,
Kenneth Magnone,
Rosalie McGurk,
Nils Rundquist,
Eric Wang,
Sherry Yeh
Abstract:
Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade for the W.M. Keck Observatory. We present the design and analysis of the imager optical assembly including the spectrograph Re-Imaging Optics (RIO) which transfers the beam path from the imager focal plane to the IFS slicer module…
▽ More
Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade for the W.M. Keck Observatory. We present the design and analysis of the imager optical assembly including the spectrograph Re-Imaging Optics (RIO) which transfers the beam path from the imager focal plane to the IFS slicer module and lenslet array. Each imager component and the first two RIO mechanisms are assembled and individually aligned on the same optical plate. Baffling suppresses background radiation and scattered light, and a pupil viewing camera allows the imager detector to focus on an image of the telescope pupil. The optical plate mounts on an adapter frame for alignment of the overall system. The imager and RIO will be characterized in a cryogenic test chamber before installation in the final science cryostat.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric characterization of anisoplanatic PSFs and testing of PSF-Reconstruction via AIROPA
Authors:
Nils Rundquist,
Shelley A. Wright,
Matthias Schoeck,
Arun Surya,
Jessica Lu,
Paolo Turri,
Edward L. Chapin,
Eric Chisholm,
Tuan Dod,
Jennifer Dunn,
Andrea Ghez,
Yutaka Hayano,
Chris Johnson,
James E. Larkin,
Reed L. Riddle,
Ji Man Sohn,
Ryuji Suzuki,
Gregory Walth,
Andrea Zonca
Abstract:
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by the Narrow-Field Infrared Adaptive Optics System (NFIRAOS) with a near-infrared (0.8 - 2.4 $μ$m) imaging camera and integral field spectrograph. To better understand IRIS science specifications we use the IRIS data simulator to…
▽ More
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by the Narrow-Field Infrared Adaptive Optics System (NFIRAOS) with a near-infrared (0.8 - 2.4 $μ$m) imaging camera and integral field spectrograph. To better understand IRIS science specifications we use the IRIS data simulator to characterize relative photometric precision and accuracy across the IRIS imaging camera 34"x34" field of view. Because the Point Spread Function (PSF) varies due to the effects of anisoplanatism, we use the Anisoplanatic and Instrumental Reconstruction of Off-axis PSFs for AO (AIROPA) software package to conduct photometric measurements on simulated frames using PSF-fitting as the PSF varies in single-source, binary, and crowded field use cases. We report photometric performance of the imaging camera as a function of the instrumental noise properties including dark current and read noise. Using the same methods, we conduct comparisons of photometric performance with reconstructed PSFs, in order to test the veracity of the current PSF-Reconstruction algorithms for IRIS/TMT.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric precision and ghost analysis
Authors:
Nils Rundquist,
Gregory Walth,
Shelley A. Wright,
Ryuji Suzuki,
Tuan Do,
Edward L. Chapin,
Eric Chisholm,
Jennifer Dunn,
Yutaka Hayano,
Chris Johnson,
James E. Larkin,
Reed L. Riddle,
Matthias Schoeck,
Ji Man Sohn
Abstract:
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by NFIRAOS with a near-infrared (0.8 - 2.4 $μ$m) imaging camera and Integral Field Spectrograph (IFS). In order to understand the science case specifications of the IRIS instrument, we use the IRIS data simulator to characterize p…
▽ More
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by NFIRAOS with a near-infrared (0.8 - 2.4 $μ$m) imaging camera and Integral Field Spectrograph (IFS). In order to understand the science case specifications of the IRIS instrument, we use the IRIS data simulator to characterize photometric precision and accuracy of the IRIS imager. We present the results of investigation into the effects of potential ghosting in the IRIS optical design. Each source in the IRIS imager field of view results in ghost images on the detector from IRIS's wedge filters, entrance window, and Atmospheric Dispersion Corrector (ADC) prism. We incorporated each of these ghosts into the IRIS simulator by simulating an appropriate magnitude point source at a specified pixel distance, and for the case of the extended ghosts redistributing flux evenly over the area specified by IRIS's optical design. We simulate the ghosting impact on the photometric capabilities, and found that ghosts generally contribute negligible effects on the flux counts for point sources except for extreme cases where ghosts coalign with a star of $Δ$m$>$2 fainter than the ghost source. Lastly, we explore the photometric precision and accuracy for single sources and crowded field photometry on the IRIS imager.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
The Infrared Imaging Spectrograph (IRIS) for TMT: advancing the data reduction system
Authors:
Gregory L. Walth,
Shelley A. Wright,
Nils-Erik Rundquist,
David Andersen,
Edward Chapin,
Eric Chisholm,
Tuan Do,
Jennifer Dunn,
Brent Ellerbroek,
Kim Gillies,
Yutaka Hayano,
Chris Johnson,
James Larkin,
Takashi Nakamoto,
Reed Riddle,
Luc Simard,
Roger Smith,
Ryuji Suzuki,
Ji Man Sohn,
Robert Weber,
Jason Weissd,
Kai Zhang
Abstract:
Infrared Imaging Spectrograph (IRIS) is the first light instrument for the Thirty Meter Telescope (TMT) that consists of a near-infrared (0.84 to 2.4 micron) imager and integral field spectrograph (IFS) which operates at the diffraction-limit utilizing the Narrow-Field Infrared Adaptive Optics System (NFIRAOS). The imager will have a 34 arcsec x 34 arcsec field of view with 4 milliarcsecond (mas)…
▽ More
Infrared Imaging Spectrograph (IRIS) is the first light instrument for the Thirty Meter Telescope (TMT) that consists of a near-infrared (0.84 to 2.4 micron) imager and integral field spectrograph (IFS) which operates at the diffraction-limit utilizing the Narrow-Field Infrared Adaptive Optics System (NFIRAOS). The imager will have a 34 arcsec x 34 arcsec field of view with 4 milliarcsecond (mas) pixels. The IFS consists of a lenslet array and slicer, enabling four plate scales from 4 mas to 50 mas, multiple gratings and filters, which in turn will operate hundreds of individual modes. IRIS, operating in concert with NFIRAOS will pose many challenges for the data reduction system (DRS). Here we present the updated design of the real-time and post-processing DRS. The DRS will support two modes of operation of IRIS: (1) writing the raw readouts sent from the detectors and performing the sampling on all of the readouts for a given exposure to create a raw science frame; and (2) reduction of data from the imager, lenslet array and slicer IFS. IRIS is planning to save the raw readouts for a given exposure to enable sophisticated processing capabilities to the end users, such as the ability to remove individual poor seeing readouts to improve signal-to-noise, or from advanced knowledge of the point spread function (PSF). The readout processor (ROP) is a key part of the IRIS DRS design for writing and sampling of the raw readouts into a raw science frame, which will be passed to the TMT data archive. We discuss the use of sub-arrays on the imager detectors for saturation/persistence mitigation, on-detector guide windows, and fast readout science cases (< 1 second).
△ Less
Submitted 22 August, 2018;
originally announced August 2018.