-
Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
Authors:
D. Yu. Akimov,
I. S. Aleksandrov,
F. B. Ata Kurbonova,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
Yu. I. Koskin,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy recons…
▽ More
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy reconstruction procedures, and evaluation of the efficiency of electron extraction from the liquid xenon to the gas phase.
△ Less
Submitted 15 May, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant
Authors:
D. Y. Akimov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
B. O. Lavrov,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper descr…
▽ More
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper describes the external background conditions for the RED-100 experiment at Kalinin Nuclear Power Plant.
△ Less
Submitted 24 November, 2023; v1 submitted 1 November, 2023;
originally announced November 2023.
-
The RED-100 experiment
Authors:
D. Yu. Akimov,
I. S. Alexandrov,
R. R. Alyev,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
E. M. Glagovsky,
Y. V. Gusakov,
A. V. Khromov,
S. M. Kiselev,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is des…
▽ More
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is described. There is no correlation of the radioactive background at the experimental setup site with ON and OFF states of the reactor. The data taking run was carried out at the beginning of the year 2022 and covered both the reactor OFF and ON periods.
△ Less
Submitted 14 November, 2022; v1 submitted 30 September, 2022;
originally announced September 2022.
-
First ground-level laboratory test of the two-phase xenon emission detector RED-100
Authors:
D. Yu. Akimov,
V. A. Belov,
A. I. Bolozdynya,
Yu. V. Efremenko,
A. V. Etenko,
A. V. Galavanov,
D. V. Gouss,
Yu. V. Gusakov,
Dj. Ed. Kdib,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
Yu. A. Melikyan,
V. V. Moramzin,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
Yu. V. Stogov,
A. A. Vasin
Abstract:
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats…
▽ More
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamatsu R11410-20 PMTs assembled in two planes on top and bottom. The electrode system is equipped with an electron shutter (a patented device) to reduce a "spontaneous" single-electron noise. The detector was tested in a ground-level laboratory. The obtained results demonstrate that detection of coherent elastic scattering of reactor antineutrinos off xenon nuclei at Kalinin nuclear power plant with the RED-100 detector is feasible with a threshold of 4 ionization electrons.
△ Less
Submitted 14 October, 2019;
originally announced October 2019.
-
Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
Authors:
D. Yu. Akimov,
V. V. Afanasyev,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
Yu. V. Efremenko,
D. A. Egorov,
A. V. Etenko,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin,
A. M. Konovalov,
A. G. Kovalenko,
A. V. Kuchenkov,
A. V. Kumpan,
Yu. A. Melikyan,
R. I. Nikolaev,
D. G. Rudik,
V. V. Sosnovtsev
, et al. (1 additional authors not shown)
Abstract:
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predicti…
▽ More
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predictions. Decay time of scintillation at 2.82 keV is measured to be 25 +/- 3 ns at the electric field of 3.75 kV/cm.
△ Less
Submitted 8 August, 2014;
originally announced August 2014.
-
Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector
Authors:
RED Collaboration,
D. Yu. Akimov,
I. S. Alexandrov,
V. I. Aleshin,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. S. Chepurnov,
M. V. Danilov,
A. V. Derbin,
V. V. Dmitrenko,
A. G. Dolgolenko,
D. A. Egorov,
Yu. V. Efremenko,
A. V. Etenko,
M. B. Gromov,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kantserov,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin
, et al. (21 additional authors not shown)
Abstract:
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites…
▽ More
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites have advantages as well as limitations. However the experiment looks feasible at either location. Preliminary design of the detector and supporting R&D program are discussed.
△ Less
Submitted 9 December, 2012;
originally announced December 2012.