Protecting backaction-evading measurements from parametric instability
Authors:
E. P. Ruddy,
Y. Jiang,
N. E. Frattini,
K. O. Quinlan,
K. W. Lehnert
Abstract:
Noiseless measurement of a single quadrature in systems of parametrically coupled oscillators is theoretically possible by pum** at the sum and difference frequencies of the two oscillators, realizing a backaction-evading (BAE) scheme. Although this would hold true in the simplest scenario for a system with pure three-wave mixing, implementations of this scheme are hindered by unwanted higher-or…
▽ More
Noiseless measurement of a single quadrature in systems of parametrically coupled oscillators is theoretically possible by pum** at the sum and difference frequencies of the two oscillators, realizing a backaction-evading (BAE) scheme. Although this would hold true in the simplest scenario for a system with pure three-wave mixing, implementations of this scheme are hindered by unwanted higher-order parametric processes that destabilize the system and add noise. We show analytically that detuning the two pumps from the sum and difference frequencies can stabilize the system and fully recover the BAE performance, enabling operation at otherwise inaccessible cooperativities. We also show that the acceleration demonstrated in a weak signal detection experiment [PRX QUANTUM 4, 020302 (2023)] was only achievable because of this detuning technique.
△ Less
Submitted 7 June, 2024; v1 submitted 17 August, 2023;
originally announced August 2023.
-
New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver
Authors:
HAYSTAC Collaboration,
M. J. Jewell,
A. F. Leder,
K. M. Backes,
Xiran Bai,
K. van Bibber,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Maryam H. Esmat,
Sumita Ghosh,
Eleanor Graham,
Gene C. Hilton,
H. Jackson,
Claire Laffan,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
E. P. Ruddy,
M. Simanovskaia,
Sukhman Singh
, et al. (4 additional authors not shown)
Abstract:
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr…
▽ More
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.
△ Less
Submitted 26 January, 2023; v1 submitted 23 January, 2023;
originally announced January 2023.
-
Bandwidth and visibility improvement in detection of a weak signal using mode entanglement and swap**
Authors:
Yue Jiang,
Elizabeth P. Ruddy,
Kyle O. Quinlan,
Maxime Malnou,
Nicholas E. Frattini,
Konrad W. Lehnert
Abstract:
Quantum fluctuations constitute the primary noise barrier limiting cavity-based axion dark matter searches. In an experiment designed to mimic a real axion search, we employ a quantum-enhanced sensing technique to detect a synthetic axion-like microwave tone at an unknown frequency weakly coupled to a resonator, demonstrating a factor of 5.6 acceleration relative to a quantum-limited search for th…
▽ More
Quantum fluctuations constitute the primary noise barrier limiting cavity-based axion dark matter searches. In an experiment designed to mimic a real axion search, we employ a quantum-enhanced sensing technique to detect a synthetic axion-like microwave tone at an unknown frequency weakly coupled to a resonator, demonstrating a factor of 5.6 acceleration relative to a quantum-limited search for the same tone. The acceleration comes from increases to both the visibility bandwidth and the peak visibility of a detector. This speedup is achieved by dynamically coupling the resonator mode to a second (readout) mode with balanced swap** and two-mode squeezing interactions. A small fractional imbalance between the two interaction rates yields further scan rate enhancement and we demonstrate that an 8-fold acceleration can be achieved.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
A cavity entanglement and state swap** method to accelerate the search for axion dark matter
Authors:
K. Wurtz,
B. M. Brubaker,
Y. Jiang,
E. P. Ruddy,
D. A. Palken,
K. W. Lehnert
Abstract:
In cavity-based axion dark matter detectors, quantum noise remains a primary barrier to achieving the scan rate necessary for a comprehensive search of axion parameter space. Here we introduce a method of scan rate enhancement in which an axion-sensitive cavity is coupled to an auxiliary resonant circuit through simultaneous two-mode squeezing (entangling) and state swap** interactions. We show…
▽ More
In cavity-based axion dark matter detectors, quantum noise remains a primary barrier to achieving the scan rate necessary for a comprehensive search of axion parameter space. Here we introduce a method of scan rate enhancement in which an axion-sensitive cavity is coupled to an auxiliary resonant circuit through simultaneous two-mode squeezing (entangling) and state swap** interactions. We show analytically that when combined, these interactions can amplify an axion signal before it becomes polluted by vacuum noise introduced by measurement. This internal amplification yields a wider bandwidth of axion sensitivity, increasing the rate at which the detector can search through frequency space. With interaction rates predicted by circuit simulations of this system, we show that this technique can increase the scan rate up to 15-fold relative to the scan rate of a detector limited by vacuum noise.
△ Less
Submitted 22 April, 2022; v1 submitted 8 July, 2021;
originally announced July 2021.