-
Depth-dependent resolution quantification in 3D fluorescence microscopy
Authors:
Neil Wright,
Christopher J. Rowlands
Abstract:
A method is presented to quantify resolution as a function of depth in features of morphologically complex 3D samples. Applying the method to the brain of Drosophila, resolution is measured at increasing depth throughout the central brain region. The results quantify improvements in image quality when using two-photon microscopy compared to confocal. It is also demonstrated how resolution improvem…
▽ More
A method is presented to quantify resolution as a function of depth in features of morphologically complex 3D samples. Applying the method to the brain of Drosophila, resolution is measured at increasing depth throughout the central brain region. The results quantify improvements in image quality when using two-photon microscopy compared to confocal. It is also demonstrated how resolution improvements through tuning a single parameter, laser power, can be measured objectively. Since the metric is interpretable as the average resolution within a feature, it is suitable for comparing results across optical systems, and can be used to inform the design of biological experiments requiring resolution of structures at a specific scale.
△ Less
Submitted 9 June, 2023;
originally announced June 2023.
-
DIRECT, a low-cost system for high-speed, low-noise imaging of fluorescent biological samples
Authors:
Isabell Whiteley,
Chenchen Song,
Glenn A Howe,
Thomas Knöpfel,
Christopher J Rowlands
Abstract:
A targeted imaging system has been developed for applications requiring recording from stationary samples at high spatiotemporal resolutions. It works by illuminating regions of interest in rapid sequence, and recording the signal from the whole field of view onto a single photodetector, and can be implemented at low cost on an existing microscope without compromising existing functionality. The s…
▽ More
A targeted imaging system has been developed for applications requiring recording from stationary samples at high spatiotemporal resolutions. It works by illuminating regions of interest in rapid sequence, and recording the signal from the whole field of view onto a single photodetector, and can be implemented at low cost on an existing microscope without compromising existing functionality. The system is characterized in terms of speed, spatial resolution, and tissue penetration depth, before being used to record individual action potentials from ASAP-3 expressing neurons in an ex vivo mouse brain slice preparation.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
3D Super-Resolution Ultrasound with Adaptive Weight-Based Beamforming
Authors:
Jipeng Yan,
Bingxue Wang,
Kai Riemer,
Joseph Hansen-Shearer,
Marcelo Lerendegui,
Matthieu Toulemonde,
Christopher J Rowlands,
Peter D. Weinberg,
Meng-Xing Tang
Abstract:
Super-resolution ultrasound (SRUS) imaging through localising and tracking sparse microbubbles has been shown to reveal microvascular structure and flow beyond the wave diffraction limit. Most SRUS studies use standard delay and sum (DAS) beamforming, where large main lobe and significant side lobes make separation and localisation of densely distributed bubbles challenging, particularly in 3D due…
▽ More
Super-resolution ultrasound (SRUS) imaging through localising and tracking sparse microbubbles has been shown to reveal microvascular structure and flow beyond the wave diffraction limit. Most SRUS studies use standard delay and sum (DAS) beamforming, where large main lobe and significant side lobes make separation and localisation of densely distributed bubbles challenging, particularly in 3D due to the typically small aperture of matrix array probes. This study aims to improve 3D SRUS by implementing a low-cost 3D coherence beamformer based on channel signal variance, as well as two other adaptive weight-based coherence beamformers: nonlinear beamforming with p-th root compression and coherence factor. The 3D coherence beamformers, together with DAS, are compared in computer simulation, on a microflow phantom, and in vivo. Simulation results demonstrate that the adaptive weight-based beamformers can significantly narrow the main lobe and suppress the side lobes for modest computational cost. Significantly improved 3D SR images of microflow phantom and a rabbit kidney are obtained through the adaptive weight-based beamformers. The proposed variance-based beamformer performs best in simulations and experiments.
△ Less
Submitted 25 August, 2022;
originally announced August 2022.
-
MAI-SIM: interferometric multicolor structured illumination microscopy for everybody
Authors:
Edward N. Ward,
Lisa Hecker,
Charles N. Christensen,
Jacob R Lamb,
Meng Lu,
Luca Mascheroni,
Chyi Wei Chung,
Anna Wang,
Christopher J. Rowlands,
Gabriele S. Kaminski Schierle,
Clemens F. Kaminski
Abstract:
Sub-diffraction resolution, gentle sample illumination, and the possibility to image in multiple colors make Structured Illumination Microscopy (SIM) an imaging technique which is particularly well suited for live cell observations. Here, we present Machine learning Assisted Interferometric-SIM (MAI-SIM), an easy-to-implement method for high speed SIM imaging in multiple colors. The instrument is…
▽ More
Sub-diffraction resolution, gentle sample illumination, and the possibility to image in multiple colors make Structured Illumination Microscopy (SIM) an imaging technique which is particularly well suited for live cell observations. Here, we present Machine learning Assisted Interferometric-SIM (MAI-SIM), an easy-to-implement method for high speed SIM imaging in multiple colors. The instrument is based on an interferometer design in which illumination patterns are generated, rotated, and stepped in phase through movement of a single galvanometric mirror element. The design is robust, flexible, and the pattern generation process works for all wavelengths. We complement the unique properties of interferometric SIM with a machine learning toolbox that is simple and efficient to use and is superior to existing methods for the reconstruction of super-resolved images recorded by the instrument. The framework permits real-time SIM reconstructions to be performed in multiple colors, providing the user with instant visualization of the super-resolved images. We demonstrate the capability of MAI-SIM on live biological samples and capture super-resolution images in multiple colors simultaneously over large fields of view. Finally, we embrace a fully open design philosophy to bring the advantages of MAI-SIM to as many users as possible and provide full details on system design and software.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
A method for assessing the spatiotemporal resolution of Structured Illumination Microscopy (SIM)
Authors:
Abderrahim Boualam,
Christopher J Rowlands
Abstract:
A method is proposed for assessing the temporal resolution of Structured Illumination Microscopy (SIM), by tracking the amplitude of different spatial frequency components over time, and comparing them to a temporally-oscillating ground-truth. This method is used to gain insight into the performance limits of SIM, along with alternative reconstruction techniques (termed 'rolling SIM') that claim t…
▽ More
A method is proposed for assessing the temporal resolution of Structured Illumination Microscopy (SIM), by tracking the amplitude of different spatial frequency components over time, and comparing them to a temporally-oscillating ground-truth. This method is used to gain insight into the performance limits of SIM, along with alternative reconstruction techniques (termed 'rolling SIM') that claim to improve temporal resolution. Results show that the temporal resolution of SIM varies considerably between low and high spatial frequencies, and that, despite being used in several high profile papers and commercial microscope software, rolling SIM provides no increase in temporal resolution over conventional SIM.
△ Less
Submitted 3 August, 2020;
originally announced August 2020.