-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Atomic fountains and optical clocks at SYRTE: status and perspectives
Authors:
M. Abgrall,
B. Chupin,
L. De Sarlo,
J. Guéna,
Ph. Laurent,
Y. Le Coq,
R. Le Targat,
J. Lodewyck,
M. Lours,
P. Rosenbusch,
D. Rovera,
S. Bize
Abstract:
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekee**. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w…
▽ More
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekee**. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
Frequency and time transfer for metrology and beyond using telecommunication network fibres
Authors:
Olivier Lopez,
Fabien Kéfélian,
Haifeng Jiang,
Adil Haboucha,
Anthony Bercy,
Fabio Stefani,
Bruno Chanteau,
Amale Kanj,
Daniele Rovera,
Joseph Achkar,
Christian Chardonnet,
Paul-Eric Pottie,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained.…
▽ More
The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained. We show that public telecommunication network carrying Internet data can be used to compare and distribute ultra-stable metrological signals over long distances. This novel technique paves the way for the deployment of a national and continental ultra-stable metrological optical network.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Testing local position and fundamental constant invariance due to periodic gravitation and boost using long-term comparison of the SYRTE atomic fountains and H-masers
Authors:
M. E. Tobar,
P. L. Stanwix,
J. J. McFerran,
J. Guéna,
M. Abgrall,
S. Bize,
A. Clairon,
Ph. Laurent,
P. Rosenbusch,
D. Rovera,
G. Santarelli
Abstract:
The frequencies of three separate Cs fountain clocks and one Rb fountain clock have been compared to various hydrogen masers to search for periodic changes correlated with the changing solar gravitational potential at the Earth and boost with respect to the Cosmic Microwave Background (CMB) rest frame. The data sets span over more than eight years. The main sources of long-term noise in such exper…
▽ More
The frequencies of three separate Cs fountain clocks and one Rb fountain clock have been compared to various hydrogen masers to search for periodic changes correlated with the changing solar gravitational potential at the Earth and boost with respect to the Cosmic Microwave Background (CMB) rest frame. The data sets span over more than eight years. The main sources of long-term noise in such experiments are the offsets and linear drifts associated with the various H-masers. The drift can vary from nearly immeasurable to as high as 1.3*10^-15 per day. To circumvent these effects we apply a numerical derivative to the data, which significantly reduces the standard error when searching for periodic signals. We determine a standard error for the putative Local Position Invariance (LPI) coefficient with respect to gravity for a Cs-Fountain H-maser comparison of 4.8*10^-6 and 10^-5 for a Rb-Fountain H-maser comparison. From the same data the putative boost LPI coefficients were measured to a precision of up to parts in 10^11 with respect to the CMB rest frame. By combining these boost invariance experiments to a Cryogenic Sapphire Oscillator versus H-maser comparison, independent limits on all nine coefficients of the boost violation vector with respect to fundamental constant invariance (fine structure constant, electron mass and quark mass respectively), were determined to a precision of parts up to 10^10.
△ Less
Submitted 6 June, 2013;
originally announced June 2013.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock
Authors:
J. Guéna,
P. Rosenbusch,
Ph. Laurent,
M. Abgrall,
D. Rovera,
M. Lours,
G. Santarelli,
M. E. Tobar,
S. Bize,
A. Clairon
Abstract:
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency meas…
▽ More
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency measurement campaign performed with FO2 in this dual atom clock configuration, including a new determination of the absolute 87Rb hyperfine frequency.
△ Less
Submitted 3 January, 2013;
originally announced January 2013.
-
Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network
Authors:
Olivier Lopez,
Amale Kanj,
Paul-Eric Pottie,
Giovanni D. Rovera,
Joseph Achkar,
Christian Chardonnet,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spr…
▽ More
In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spread spectrum signals using two-way satellite time transfer modems. The results in term of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.
△ Less
Submitted 4 October, 2012; v1 submitted 21 September, 2012;
originally announced September 2012.
-
Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Peter Rosenbusch,
Michael E. Tobar,
Philippe Laurent,
André Clairon,
Sébastien Bize
Abstract:
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H.…
▽ More
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.
△ Less
Submitted 22 August, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
Progress in Atomic Fountains at LNE-SYRTE
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Philippe Laurent,
Baptiste Chupin,
Michel Lours,
Giorgio Santarelli,
Peter Rosenbusch,
Michael E. Tobar,
Ruoxin Li,
Kurt Gibble,
André Clairon,
Sébastien Bize
Abstract:
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed…
▽ More
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
Improved Measurement of the Hydrogen 1S - 2S Transition Frequency
Authors:
Christian G. Parthey,
Arthur Matveev,
Janis Alnis,
Birgitta Bernhardt,
Axel Beyer,
Ronald Holzwarth,
Aliaksei Maistrou,
Randolf Pohl,
Katharina Predehl,
Thomas Udem,
Tobias Wilken,
Nikolai Kolachevsky,
Michel Abgrall,
Daniele Rovera,
Christophe Salomon,
Philippe Laurent,
Theodor W. Hänsch
Abstract:
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3.…
▽ More
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.
△ Less
Submitted 15 July, 2011;
originally announced July 2011.
-
Absolute frequency measurement of the 40Ca+ S1/2 - D5/2 clock transition
Authors:
M. Chwalla,
J. Benhelm,
K. Kim,
G. Kirchmair,
T. Monz,
M. Riebe,
P. Schindler,
A. S. Villar,
W. Haensel,
C. F. Roos,
R. Blatt,
M. Abgrall,
G. Santarelli,
G. D. Rovera,
Ph. Laurent
Abstract:
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the S1/2-D5/2 electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transi…
▽ More
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the S1/2-D5/2 electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency f_Ca+ = 411 042 129 776 393.2 (1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of three of the Cs standard. Future improvements are expected to lead to an uncertainty surpassing the best Cs fountain clocks. In addition, we determine the Lande g-factor of the D5/2 level to be gD5/2=1.2003340(3).
△ Less
Submitted 9 June, 2008;
originally announced June 2008.
-
An Optical Lattice Clock with Spin-polarized 87Sr Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Frédéric Chapelet,
Michel Abgrall,
Giovanni D. Rovera,
Philippe Laurent,
Peter Rosenbusch,
Sébastien Bize,
Giorgio Santarelli,
André Clairon,
Pierre Lemonde,
Gesine Grosche,
Burghard Lipphardt,
Harald Schnatz
Abstract:
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one o…
▽ More
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy.
△ Less
Submitted 29 September, 2007;
originally announced October 2007.
-
Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Yann Le Coq,
Giovanni D. Rovera,
Sebastien Bize,
Pierre Lemonde
Abstract:
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss…
▽ More
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss the conditions necessary to reach a clock accuracy of 10^{-17} or less using this scheme.
△ Less
Submitted 14 March, 2007;
originally announced March 2007.
-
An accurate optical lattice clock with 87Sr atoms
Authors:
Rodolphe Le Targat,
Xavier Baillard,
Mathilde Fouché,
Anders Brusch,
Olivier Tcherbakoff,
Giovanni D. Rovera,
Pierre Lemonde
Abstract:
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall. Two previous measurements of this transition were found to disagree by about 2x10^{-13}, i.e. almost four times the c…
▽ More
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall. Two previous measurements of this transition were found to disagree by about 2x10^{-13}, i.e. almost four times the combined error bar, instilling doubt on the potential of optical lattice clocks to perform at a high accuracy level. In perfect agreement with one of these two values, our measurement essentially dissipates this doubt.
△ Less
Submitted 23 May, 2006;
originally announced May 2006.
-
Accurate spectroscopy of Sr atoms
Authors:
Irene Courtillot,
Audrey Quessada-Vial,
Anders Brusch,
Dmitri Kolker,
Giovanni D. Rovera,
Pierre Lemonde
Abstract:
We report the frequency measurement with an accuracy in the 100 kHz range of several optical transitions of atomic Sr : $^1S_0- ^3P_1$ at 689 nm, $^3P_1- ^3S_1$ at 688 nm and $^3P_0- ^3S_1$ at 679 nm. Measurements are performed with a frequency chain based on a femtosecond laser referenced to primary frequency standards. They allowed the indirect determination with a 70 kHz uncertainty of the fr…
▽ More
We report the frequency measurement with an accuracy in the 100 kHz range of several optical transitions of atomic Sr : $^1S_0- ^3P_1$ at 689 nm, $^3P_1- ^3S_1$ at 688 nm and $^3P_0- ^3S_1$ at 679 nm. Measurements are performed with a frequency chain based on a femtosecond laser referenced to primary frequency standards. They allowed the indirect determination with a 70 kHz uncertainty of the frequency of the doubly forbidden $5s^2^1S_0- 5s5p^3P_0$ transition of $^{87}$Sr at 698 nm and in a second step its direct observation. Frequency measurements are performed for $^{88}$Sr and $^{87}$Sr, allowing the determination of $^3P_0$, $^3P_1$ and $^3S_1$ isotope shifts, as well as the $^3S_1$ hyperfine constants.
△ Less
Submitted 31 January, 2005; v1 submitted 15 October, 2004;
originally announced October 2004.
-
A clock transition for a future optical frequency standard with trapped atoms
Authors:
I. Courtillot,
A. Quessada,
R. P. Kovacich,
A. Brusch,
D. Kolker,
J-J. Zondy,
G. D. Rovera,
P. Lemonde
Abstract:
We report the first direct excitation of the strongly forbidden 5s2 1S0-5s5p 3P0 transition in 87Sr. Its frequency is 429 228 004 235 (20) kHz. A resonant laser creates a small leak in a magneto-optical trap (MOT): atoms build up to the metastable 3P0 state and escape the trap** process, leading to a detectable decrease in the MOT fluorescence. This line has a natural width of 10^{-3} Hz and c…
▽ More
We report the first direct excitation of the strongly forbidden 5s2 1S0-5s5p 3P0 transition in 87Sr. Its frequency is 429 228 004 235 (20) kHz. A resonant laser creates a small leak in a magneto-optical trap (MOT): atoms build up to the metastable 3P0 state and escape the trap** process, leading to a detectable decrease in the MOT fluorescence. This line has a natural width of 10^{-3} Hz and can be used for a new generation of optical frequency standards using atoms trapped in a light shift free dipole trap.
△ Less
Submitted 6 March, 2003;
originally announced March 2003.