Showing 1–2 of 2 results for author: Rotinberg, P
-
Extremely low-frequency electromagnetic fields cause DNA strand breaks in normal Vero cells
Authors:
Cosmin Teodor Miha,
Gabriela Vochita,
Florin Brinza,
Pincu Rotinberg
Abstract:
Extremely low frequency electromagnetic fields aren't considered as a real carcinogenic agent despite the fact that some studies have showed impairment of the DNA integrity in different cells lines. The aim of this study was evaluation of the late effects of a 100 Hz and 5.6 mT electromagnetic field, applied continuously or discontinuously, on the DNA integrity of Vero cells assessed by alkaline C…
▽ More
Extremely low frequency electromagnetic fields aren't considered as a real carcinogenic agent despite the fact that some studies have showed impairment of the DNA integrity in different cells lines. The aim of this study was evaluation of the late effects of a 100 Hz and 5.6 mT electromagnetic field, applied continuously or discontinuously, on the DNA integrity of Vero cells assessed by alkaline Comet assay and by cell cycle analysis. Normal Vero cells were exposed to extremely low frequency electromagnetic fields (100 Hz, 5.6 mT) for 45 minutes. The Comet assay and cell cycle analysis were performed 48 hours after the treatment. Exposed samples presented an increase of the number of cells with high damaged DNA as compared with non-exposed cells. Quantitative evaluation of the comet assay showed a significantly ($<$0.001) increase of the tail lengths, of the quantity of DNA in tail and of Olive tail moments, respectively. The analysis of the registered comet indices showed that an extremely low frequency electromagnetic field of 100 Hz and 5.6 mT had a genotoxic impact on Vero cells. Cell cycle analysis showed an increase of the frequency of the cells in S phase, proving the occurrence of single strand breaks. The most probable mechanism of induction of the registered effects is the production of different types of reactive oxygen species.
△ Less
Submitted 23 January, 2013;
originally announced January 2013.
-
In vitro investigation of the effects of X- rays carried by a photon beam upon the cell cycle progression in Vero cells
Authors:
Cosmin Teodor Mihai,
Gabriela Vochita,
Ramona Focea,
Pincu Rotinberg
Abstract:
The effects of the X-rays carried out in a photon beam produced by a medical linear particle accelerator on the progression of the cell cycle in normal cells Vero were evaluated by flow cytometric mean. The evaluation of the consequences of 1 and 3 Gy irradiation upon cell cycle development was performed after 96 and 120 hours from the exposure moment, in order to register the late effects of irra…
▽ More
The effects of the X-rays carried out in a photon beam produced by a medical linear particle accelerator on the progression of the cell cycle in normal cells Vero were evaluated by flow cytometric mean. The evaluation of the consequences of 1 and 3 Gy irradiation upon cell cycle development was performed after 96 and 120 hours from the exposure moment, in order to register the late effects of irradiation. As compared with the control group (sham exposed) the treated cells with the dose of 1 Gy have shown an increase of the frequency of cells blocked in S and G2/M stages and also of the apoptotic cells at 96 hours from the treatment. After another 24 hours, the frequency of the blocked cells in S and G2/M has decreased. The response of the 96 hours cell cultures to 3 Gy treatment was faster, as suggested by the increased number of apoptotic cells and by reduced frequency of the arrested cells in S and G2/M. The blockage of Vero cells in different phases of the cell-cycle and the presence of active repairing systems reveals the reduced risk of the malignant transformation of the exposed normal cells and could offer an enhanced cell protection to another damaging agents.
△ Less
Submitted 15 January, 2013;
originally announced January 2013.