Construction and Performance of a Micro-Pattern Stereo Detector with Two Gas Electron Multipliers
Authors:
T. Barvich,
P. Bluem,
M. Erdmann,
M. Fahrer,
K. Kaercher,
F. Kuehn,
D. Moermann,
Th. Mueller,
D. Neuberger,
F. Roederer,
H. J. Simonis,
A. Skiba,
W. H. Thuemmel,
Th. Weiler,
S. Weseler
Abstract:
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same technology as the GEM foils. The strips of each layer cross at an effective crossing angle of 6.7 degrees and have a 406 um pitch. The performance of the detecto…
▽ More
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same technology as the GEM foils. The strips of each layer cross at an effective crossing angle of 6.7 degrees and have a 406 um pitch. The performance of the detector has been evaluated in a muon beam at CERN using a silicon telescope as reference system. The position resolutions of two orthogonal coordinates are measured to be 50 um and 1 mm, respectively. The muon detection efficiency for two-dimensional space points reaches 96%.
△ Less
Submitted 4 October, 2001;
originally announced October 2001.