-
Designing a boron nitride polyethylene composite for shielding neutrons
Authors:
Alisha D. Vira,
Elizabeth Mone,
Emily Ryan,
Patrick Connolly,
Karl Smith,
Caleb Roecker,
Katherine Mesick,
Thomas M. Orlando,
Zhigang Jiang,
Phillip N. First
Abstract:
Neutrons are encountered in many different fields, including condensed matter physics, space exploration, nuclear power, and healthcare. Neutrons interacting with a biological target produce secondary charged particles that are damaging to human health. The most effective way to shield neutrons is to slow them to thermal energies and then capture the thermalized neutrons. These factors lead us to…
▽ More
Neutrons are encountered in many different fields, including condensed matter physics, space exploration, nuclear power, and healthcare. Neutrons interacting with a biological target produce secondary charged particles that are damaging to human health. The most effective way to shield neutrons is to slow them to thermal energies and then capture the thermalized neutrons. These factors lead us to consider potential materials solutions for neutron shields that maximize the protection of humans while minimizing the shield mass, and which adapt well to modern additive manufacturing techniques. Using hexagonal boron nitride (hBN) as a capture medium and high-density polyethylene (HDPE) as a thermalization medium, we aim to design the optimal internal structure of h$^{10}$BN/HDPE composites by minimizing the effective dose, which is a measure of the estimated radiation damage exposure for a human. Through Monte Carlo simulations in Geant4, we find that the optimal structure reduces the effective dose up to a factor of 72x over aluminum (Al) and 4x over HDPE; this is a significant improvement in shielding effectiveness that could dramatically reduce the radiation exposure of occupational workers.
△ Less
Submitted 4 October, 2023; v1 submitted 16 November, 2022;
originally announced November 2022.
-
Measurement of Muon-induced High-energy Neutrons from Rock in an Underground Gd-doped Water Detector
Authors:
F. Sutanto,
O. A. Akindele,
M. Askins,
M. Bergevin,
A. Bernstein,
N. S. Bowden,
S. Dazeley,
P. Jaffke,
I. Jovanovic,
S. Quillin,
C. Roecker,
S. D. Rountree
Abstract:
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results w…
▽ More
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results with the expected rate of correlated neutron captures arising from high-energy neutrons incident on the outside of the WATCHBOY shield, predicted by a hybrid FLUKA/GEANT4-based simulation. The incident neutron energy distribution used in the simulation was measured by a fast neutron spectrometer, the 1.8-ton Multiplicity and Recoil Spectrometer (MARS) detector, at the same depth. We find that the measured detection rate of two correlated neutrons is consistent with that predicted by simulation. The result lends additional confidence in the detection technique used by MARS, and therefore in the MARS spectra as measured at three different depths. Confirmation of the fast neutron flux and spectrum is important as it helps validate the scaling models used to predict the fast neutron fluxes at different overburdens.
△ Less
Submitted 30 August, 2020;
originally announced August 2020.
-
Precision and accuracy of single-molecule FRET measurements - a worldwide benchmark study
Authors:
Björn Hellenkamp,
Sonja Schmid,
Olga Doroshenko,
Oleg Opanasyuk,
Ralf Kühnemuth,
Soheila Rezaei Adariani,
Anders Barth,
Victoria Birkedal,
Mark E. Bowen,
Hongtao Chen,
Thorben Cordes,
Tobias Eilert,
Carel Fijen,
Markus Götz,
Giorgos Gouridis,
Enrico Gratton,
Taekjip Ha,
Christian A. Hanke,
Andreas Hartmann,
Jelle Hendrix,
Lasse L. Hildebrandt,
Johannes Hohlbein,
Christian G. Hübner,
Eleni Kallis,
Achillefs N. Kapanidis
, et al. (28 additional authors not shown)
Abstract:
Single-molecule Förster resonance energy transfer (smFRET) is increasingly being used to determine distances, structures, and dynamics of biomolecules in vitro and in vivo. However, generalized protocols and FRET standards ensuring both the reproducibility and accuracy of measuring FRET efficiencies are currently lacking. Here we report the results of a worldwide, comparative, blind study, in whic…
▽ More
Single-molecule Förster resonance energy transfer (smFRET) is increasingly being used to determine distances, structures, and dynamics of biomolecules in vitro and in vivo. However, generalized protocols and FRET standards ensuring both the reproducibility and accuracy of measuring FRET efficiencies are currently lacking. Here we report the results of a worldwide, comparative, blind study, in which 20 labs determined the FRET efficiencies of several dye-labeled DNA duplexes. Using a unified and straightforward method, we show that FRET efficiencies can be obtained with a standard deviation between $Δ$E = +-0.02 and +-0.05. We further suggest an experimental and computational procedure for converting FRET efficiencies into accurate distances. We discuss potential uncertainties in the experiment and the modelling. Our extensive quantitative assessment of intensity-based smFRET measurements and correction procedures serve as an essential step towards validation of distance networks with the ultimate aim to archive reliable structural models of biomolecular systems obtained by smFRET-based hybrid methods.
△ Less
Submitted 29 December, 2017; v1 submitted 10 October, 2017;
originally announced October 2017.
-
The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos
Authors:
M. Askins,
M. Bergevin,
A. Bernstein,
S. Dazeley,
S. T. Dye,
T. Handler,
A. Hatzikoutelis,
D. Hellfeld,
P. Jaffke,
Y. Kamyshkov,
B. J. Land,
J. G. Learned,
P. Marleau,
C. Mauger,
G. D. Orebi Gann,
C. Roecker,
S. D. Rountree,
T. M. Shokair,
M. B. Smy,
R. Svoboda,
M. Sweany,
M. R. Vagins,
K. A. van Bibber,
R. B. Vogelaar,
M. J. Wetstein
, et al. (1 additional authors not shown)
Abstract:
This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational stat…
▽ More
This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a first- ever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications.
During its first phase, the detector will provide a critical large-scale test of the ability to tag neutrons and thus distinguish low energy electron neutrinos and antineutrinos. This would make WATCHMAN the only detector capable of providing both direction and flavor identification of supernova neutrinos. It would also be the third largest supernova detector, and the largest underground in the western hemisphere. In a follow-on phase incorporating the IsoDAR neutrino beam, the detector would have world-class sensitivity to sterile neutrino signatures and to non-standard electroweak interactions (NSI). WATCHMAN will also be a major, U.S. based integration platform for a host of technologies relevant for the Long-Baseline Neutrino Facility (LBNF) and other future large detectors.
This white paper describes the WATCHMAN conceptual design,and presents the results of detailed simulations of sensitivity for the project's nonproliferation and physics goals. It also describes the advanced technologies to be used in WATCHMAN, including high quantum efficiency photomultipliers, Water-Based Liquid Scintillator (WbLS), picosecond light sensors such as the Large Area Picosecond Photo Detector (LAPPD), and advanced pattern recognition and particle identification methods.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
Scanning Gate Microscopy on Graphene: Charge Inhomogeneity and Extrinsic Do**
Authors:
Romaneh Jalilian,
Luis A. Jauregui,
Gabriel Lopez,
Jifa Tian,
Caleb Roecker,
Mehdi M. Yazdanpanah,
Robert W. Cohn,
Igor Jovanovic,
Yong P. Chen
Abstract:
We have performed scanning gate microscopy (SGM) on graphene field effect transistors (GFET), using a biased metallic nanowire coated with a dielectric layer as a contact mode tip and local top gate. Electrical transport through graphene at various back gate voltages is monitored as a function of tip voltage and tip position. Near the Dirac point, the dependence of graphene resistance on tip volta…
▽ More
We have performed scanning gate microscopy (SGM) on graphene field effect transistors (GFET), using a biased metallic nanowire coated with a dielectric layer as a contact mode tip and local top gate. Electrical transport through graphene at various back gate voltages is monitored as a function of tip voltage and tip position. Near the Dirac point, the dependence of graphene resistance on tip voltage shows a significant variation with tip position. SGM imaging reveals mesoscopic domains of electron-doped and hole-doped regions. Our measurements indicate a substantial spatial fluctuation (on the order of 10^12/cm^2) in the carrier density in graphene due to extrinsic local do**. Important sources for such do** found in our samples include metal contacts, edges of graphene, structural defects, and resist residues.
△ Less
Submitted 28 March, 2010;
originally announced March 2010.