Incorporating Anatomical Awareness for Enhanced Generalizability and Progression Prediction in Deep Learning-Based Radiographic Sacroiliitis Detection
Authors:
Felix J. Dorfner,
Janis L. Vahldiek,
Leonhard Donle,
Andrei Zhukov,
Lina Xu,
Hartmut Häntze,
Marcus R. Makowski,
Hugo J. W. L. Aerts,
Fabian Proft,
Valeria Rios Rodriguez,
Judith Rademacher,
Mikhail Protopopov,
Hildrun Haibel,
Torsten Diekhoff,
Murat Torgutalp,
Lisa C. Adams,
Denis Poddubnyy,
Keno K. Bressem
Abstract:
Purpose: To examine whether incorporating anatomical awareness into a deep learning model can improve generalizability and enable prediction of disease progression.
Methods: This retrospective multicenter study included conventional pelvic radiographs of 4 different patient cohorts focusing on axial spondyloarthritis (axSpA) collected at university and community hospitals. The first cohort, whic…
▽ More
Purpose: To examine whether incorporating anatomical awareness into a deep learning model can improve generalizability and enable prediction of disease progression.
Methods: This retrospective multicenter study included conventional pelvic radiographs of 4 different patient cohorts focusing on axial spondyloarthritis (axSpA) collected at university and community hospitals. The first cohort, which consisted of 1483 radiographs, was split into training (n=1261) and validation (n=222) sets. The other cohorts comprising 436, 340, and 163 patients, respectively, were used as independent test datasets. For the second cohort, follow-up data of 311 patients was used to examine progression prediction capabilities. Two neural networks were trained, one on images cropped to the bounding box of the sacroiliac joints (anatomy-aware) and the other one on full radiographs. The performance of the models was compared using the area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity.
Results: On the three test datasets, the standard model achieved AUC scores of 0.853, 0.817, 0.947, with an accuracy of 0.770, 0.724, 0.850. Whereas the anatomy-aware model achieved AUC scores of 0.899, 0.846, 0.957, with an accuracy of 0.821, 0.744, 0.906, respectively. The patients who were identified as high risk by the anatomy aware model had an odds ratio of 2.16 (95% CI: 1.19, 3.86) for having progression of radiographic sacroiliitis within 2 years.
Conclusion: Anatomical awareness can improve the generalizability of a deep learning model in detecting radiographic sacroiliitis. The model is published as fully open source alongside this study.
△ Less
Submitted 12 May, 2024;
originally announced May 2024.
Mode-selective single-photon addition to a multimode quantum field
Authors:
Ganaël Roeland,
Srinivasan Kaali,
Victor Roman Rodriguez,
Nicolas Treps,
Valentina Parigi
Abstract:
Spectro-temporal modes of light can be exploited for the generation of high-dimensional Gaussian quantum states. Such states are at the basis of continuous variable quantum information protocols where they have to support mode-selective non-Gaussian operations. We develop a general framework for single-photon addition on multimode states of light via parametric down conversion processes. We identi…
▽ More
Spectro-temporal modes of light can be exploited for the generation of high-dimensional Gaussian quantum states. Such states are at the basis of continuous variable quantum information protocols where they have to support mode-selective non-Gaussian operations. We develop a general framework for single-photon addition on multimode states of light via parametric down conversion processes. We identify the analytical conditions for single-mode and mode-selective photon addition. We show that spectral mode selectivity can be achieved in the Type-II collinear down conversion, while single-mode condition are retrieved for noncollinear Type-I and Type-II processes. Numerical results are shown for photon addition in parametric down conversion process at near-infrared and telecommunications wavelengths.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
Feasibility of satellite-to-ground continuous-variable quantum key distribution
Authors:
Daniele Dequal,
Luis Trigo Vidarte,
Victor Roman Rodriguez,
Giuseppe Vallone,
Paolo Villoresi,
Anthony Leverrier,
Eleni Diamanti
Abstract:
Establishing secure communication links at a global scale is a major potential application of quantum information science but also extremely challenging for the underlying technology. While milestone experiments using satellite-to-ground links and exploiting singe-photon encoding for implementing quantum key distribution have shown recently that this goal is achievable, it is still necessary to fu…
▽ More
Establishing secure communication links at a global scale is a major potential application of quantum information science but also extremely challenging for the underlying technology. While milestone experiments using satellite-to-ground links and exploiting singe-photon encoding for implementing quantum key distribution have shown recently that this goal is achievable, it is still necessary to further investigate practical solutions compatible with classical optical communication systems. Here we examine the feasibility of establishing secret keys in a satellite-to-ground downlink configuration using continuous-variable encoding, which can be implemented using standard telecommunication components certified for space environment and able to operate at high symbol rates. Considering a realistic channel model and state-of-the-art technology, and exploiting an orbit subdivision technique for mitigating fluctuations in the transmission efficiency, we find positive secret key rates for a low-Earth-orbit scenario, while finite-size effects can be a limiting factor for higher orbits. Our analysis determines regions of values for important experimental parameters where secret key exchange is possible and can be used as a guideline for experimental efforts in this direction.
△ Less
Submitted 20 July, 2020; v1 submitted 5 February, 2020;
originally announced February 2020.