-
Experimental development and evaluation of a volume coil with slotted end-rings coil for rat MRI at 7 T
Authors:
S. Solis-Najera,
R. Martin,
F. Vazquez,
O. Marrufo,
A. O. Rodriguez
Abstract:
A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with simi…
▽ More
A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled cylindrical phantom and a digital brain of a rat. An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show an important decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, witch showed a 30% increase in experimental SNR. There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
Remote RF excitation for a small-bore MR imager at 15.2 T
Authors:
F. Vazquez,
S. E. Solis-Najera,
J. Lazovic,
L. M. Zopf,
R. Martin,
L. Medina,
O. Marrufo,
A. O. Rodriguez
Abstract:
The travelling-wave MRI approach is an alternative to overcome the B1 inhomogeneity at UHF MRI for human applications. More recently, this concept has been also used with animal MR imagers. We used a parallel-plate waveguide and a bio-inspired surface coil to generate mouse images at 15.2T. Ex vivo mouse images were acquired without high dielectric materials to conduct the signal at the right freq…
▽ More
The travelling-wave MRI approach is an alternative to overcome the B1 inhomogeneity at UHF MRI for human applications. More recently, this concept has been also used with animal MR imagers. We used a parallel-plate waveguide and a bio-inspired surface coil to generate mouse images at 15.2T. Ex vivo mouse images were acquired without high dielectric materials to conduct the signal at the right frequency. These results are in very good concordance with results obtained at 3T and 9.4T. These results show that travelling wave MRI with high SNR can be performed with a simple waveguide.
△ Less
Submitted 12 March, 2018;
originally announced March 2018.
-
Non-ergodic states induced by impurity levels in quantum spin chains
Authors:
A. O. García Rodríguez,
G. G. Cabrera
Abstract:
The semi-infinite XY spin chain with an impurity at the boundary has been chosen as a prototype of interacting many-body systems to test for non-ergodic behavior. The model is exactly solvable in analytic way in the thermodynamic limit, where energy eigenstates and the spectrum are obtained in closed form. In addition of a continuous band, localized states may split off from the continuum, for som…
▽ More
The semi-infinite XY spin chain with an impurity at the boundary has been chosen as a prototype of interacting many-body systems to test for non-ergodic behavior. The model is exactly solvable in analytic way in the thermodynamic limit, where energy eigenstates and the spectrum are obtained in closed form. In addition of a continuous band, localized states may split off from the continuum, for some values of the impurity parameters. In the next step, after the preparation of an arbitrary non-equilibrium state, we observe the time evolution of the site magnetization. Relaxation properties are described by the long-time behavior, which is estimated using the stationary phase method. Absence of localized states defines an ergodic region in parameter space, where the system relaxes to a homogeneous magnetization. Out of this region, impurity levels split from the band, and localization phenomena may lead to non-ergodicity.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Bio-inspired surface coil for small-bore MRI at 15.2 T
Authors:
S. E. Solis-Najera,
F. Vazquez,
J. Lazovic,
L. M. Zopf,
R. Martin,
L. Medina,
O. Marrufo,
A. O. Rodriguez
Abstract:
We looked for a biological analogy to developed an improved surface coil to acquire magnetic resonance images. Nature offers engineering solutions that can be exploited to improve the performance of devices, such as MRI RF coils. In this paper, we proposed a coil layout based on flower petal patterns for UHF MRI at 15.2 T. This particular configuration offers the possibility to use a different num…
▽ More
We looked for a biological analogy to developed an improved surface coil to acquire magnetic resonance images. Nature offers engineering solutions that can be exploited to improve the performance of devices, such as MRI RF coils. In this paper, we proposed a coil layout based on flower petal patterns for UHF MRI at 15.2 T. This particular configuration offers the possibility to use a different number of petals and shapes. The petal resonator coil and the magnetron coil have similar layouts, which have proved to outperform the popular circular coil. Phantom images were acquired with our coil prototype to demonstrate it feasibility. These phantom images show no image degradation caused by the mutual inductance of the adjacent petals in both orientations. The SNR was also calculated using the image data and giving 31.16. Phantom images showed the coil viability and compatibility with conventional pulse sequences at 15.2 T. It still remains to investigate whether this bio-inspired surface coil is able to outperformed the popular circular coil.
△ Less
Submitted 7 November, 2017;
originally announced November 2017.
-
Preparation of non-ergodic states in quantum spin chains
Authors:
A. O. García Rodríguez,
G. G. Cabrera
Abstract:
We test the time evolution of quite general initial states in a model that is exactly solvable, $i.e.$ a semi-infinite $XY$ spin chain with an impurity at the boundary. The dynamics is portrayed through the observation of the site magnetization along the chain, focusing on the long-time behavior of the magnetization, which is estimated using the stationary phase method. Localized states are split…
▽ More
We test the time evolution of quite general initial states in a model that is exactly solvable, $i.e.$ a semi-infinite $XY$ spin chain with an impurity at the boundary. The dynamics is portrayed through the observation of the site magnetization along the chain, focusing on the long-time behavior of the magnetization, which is estimated using the stationary phase method. Localized states are split off from the continuum for some regions of the impurity parameter space. Bound states are essential for the non-ergodic behavior reported here. When two impurity states exist, the quantum interference between them leads to magnetization oscillations which settle over very long times with the absence of dam**. The frequency of the remanent oscillation is recognized as being the Rabi frequency of the localized levels.
△ Less
Submitted 9 March, 2017;
originally announced March 2017.
-
Transmission of travelling-wave with a simple waveguide for rodents MRI at 9.4 T
Authors:
Fabian Vazquez,
Oscar Marrufo,
Rodrigo Martin,
Sergio Solis,
Alfredo O. Rodriguez
Abstract:
Standard coils can cause inhomogeneities due to the standing wave patterns at ultra high field MRI. This B1 inhomogeneity can be overcome using the travelling-wave MRI (twMRI) approach. The ma- jority of twMRI research has been done with clinical MRI scanners at 7T or above. More recently, this concept has been also used with animal MRI systems, using circular-cross section waveguides and dielectr…
▽ More
Standard coils can cause inhomogeneities due to the standing wave patterns at ultra high field MRI. This B1 inhomogeneity can be overcome using the travelling-wave MRI (twMRI) approach. The ma- jority of twMRI research has been done with clinical MRI scanners at 7T or above. More recently, this concept has been also used with animal MRI systems, using circular-cross section waveguides and dielectric materials for both type of scanners. We have demonstrated that twMRI can be used at 3 T with clinical systems and a parallel-plate waveguide. Here, we investigated the use of a parallel- plate waveguide and a RF circular coil to generate rat images with an animal MRI at 9.4 T.
△ Less
Submitted 10 November, 2015; v1 submitted 9 November, 2015;
originally announced November 2015.
-
Functional Magnetic Resonance Imaging: a study of malnourished rats
Authors:
R. Martin,
R. Godinez,
A. O. Rodriguez
Abstract:
Malnutrition is a main public health problem in develo** countries. Incidence is increasing and the mortality rate is still high. Malnutrition can leads mayor problems that can be irreversible if it is present before brain development is completed. We used BOLD (blood oxygen level-dependent effect) Functional Magnetic Resonance Imaging to investigate the regions of brain activity in malnourished…
▽ More
Malnutrition is a main public health problem in develo** countries. Incidence is increasing and the mortality rate is still high. Malnutrition can leads mayor problems that can be irreversible if it is present before brain development is completed. We used BOLD (blood oxygen level-dependent effect) Functional Magnetic Resonance Imaging to investigate the regions of brain activity in malnourished rats. The food competition method was applied to a rat model to provoke malnutrition during lactation. The weight increase is delayed even if there is plenty milk available. To localize those regions of activity resulting from the trigeminal nerve stimulation, the vibrissae-barrel axis was employed due to the functional and morphological correlation between the vibrissae and the barrels. BOLD response changes caused by the trigeminal nerve stimulation on brain activity of malnourished and control rats were obtained at 7T. Results showed a major neuronal activity in malnourished rats on regions like cerebellum, somatosensorial cortex, hippocampus, and hypothalamus. This is the first study in malnourished rats and illustrates BOLD activation in various brain structures.
△ Less
Submitted 15 January, 2013;
originally announced January 2013.
-
Travelling Wave Magnetic Resonance Imaging at 3 Tesla
Authors:
F. Vazquez,
R. Martin,
O. Marrufo,
A. O. Rodriguez
Abstract:
Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transversal electric modes and…
▽ More
Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transversal electric modes and it can propagate any frequency. To investigate the potential benefits for whole-body imaging at 3 T, we compare numerical simulations at 1.5 T, 3 T, 7 T, and 9 T via the propagation of the parallel-plate waveguide principal mode filled with a cylindrical phantom and two surface coils. B1 map** was computed to investigate the feasibility of this approach at 3T. The point spread function method was used to measure the imager performance for the traveling-wave magnetic resonance imaging experiment. Human leg images were acquired to experimentally validate this approach. The principal mode shows very little field magnitude variations along the propagation direction at 3 T when compared to other higher resonant frequencies. The B1 map** showed that it is possible to conduct experiments using the traveling-wave approach at 128 MHz. The point spread function results showed a good scanner performance for these type of experiments. Leg images were obtained with the whole-body birdcage coil and the waveguide with two circular coils for comparison purposes. The simulated and in vivo traveling-wave results correspond very well for both magnetic field and specific absorption rate. A pretty similar performance was observed for the traveling-wave approach and the conventional one. We have demonstrated the feasibility of traveling-wave magnetic resonance imaging at 3T for whole-body magnetic resonance systems, using a parallel-plate waveguide with standard pulse sequences and only one coil array.
△ Less
Submitted 15 January, 2013;
originally announced January 2013.
-
Theoretical signal-to-noise ratio of a slotted surface coil for magnetic resonance imaging
Authors:
K. Ocegueda,
S. S. Hidalgo,
S. E. Solis,
A. O. Rodriguez
Abstract:
The analytical expression for the signal-to-noise ratio of a slotted surface coil with an arbitrary number of slots was derived using the quasi-static approach. This surface coil based on the vane-type magnetron tube. To study the coil perfomance, the theoretical signal-to-noise ratio predictions of this coil design were computed using a different number of slots. Results were also compared with t…
▽ More
The analytical expression for the signal-to-noise ratio of a slotted surface coil with an arbitrary number of slots was derived using the quasi-static approach. This surface coil based on the vane-type magnetron tube. To study the coil perfomance, the theoretical signal-to-noise ratio predictions of this coil design were computed using a different number of slots. Results were also compared with theoretical results obtained for a circular coil with similar dimensions. It can be appreciated that slotted surface coil performance improves as the number of coils increases and, outperformed the circular-shaped coil. This makes it a good candidate for other MRI applications involving coil array techniques.
△ Less
Submitted 8 February, 2011;
originally announced February 2011.
-
Magnetic Resonance Imaging with a Dielectric Lens
Authors:
F. Vazquez,
O. Marrufo,
R. Martin,
A. O. Rodriguez
Abstract:
Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated w…
▽ More
Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated with single surface coils. Commercial polycarbonate glazing sheets were used together with a circular coil to generate phantom images at 3 Tesla on a clinical MR imager.
△ Less
Submitted 20 November, 2009;
originally announced November 2009.
-
Las ondas viajeras son los ojos nuevos de la resonancia en medicina
Authors:
A. O. Rodriguez,
S. S. Hidalgo
Abstract:
Magnetic Resonance Imaging is one of the most versatile experimental techniques in chemistry, physics and biology, providing insight into the structure and dynamics of matter at the molecular scale. A group led by Klaas Pruessmann at ETH Zurich (Brunner, D.O. et al. Travelling-wave nuclear magnetic resonance. Nature 457;994:2009) has now demonstrated an alternative approach that radically depart…
▽ More
Magnetic Resonance Imaging is one of the most versatile experimental techniques in chemistry, physics and biology, providing insight into the structure and dynamics of matter at the molecular scale. A group led by Klaas Pruessmann at ETH Zurich (Brunner, D.O. et al. Travelling-wave nuclear magnetic resonance. Nature 457;994:2009) has now demonstrated an alternative approach that radically departs from the conventional view of MRI as a near-field, inductive technique. This approach also required that radiofre-quency wave is propagated from an antenna positioned at one end of the cylindrical magnet; this wave travels through the specimen within the bore of the magnet, producing signals that are received either by the same antenna or by another one positioned at the opposite end. The resulting instrument considerably extends the scale of imaging possible with Magnetic Resonance Imaging, and initial tests demonstrated uniform high-field imaging of a variety of samples, both inorganic and inorganic.
△ Less
Submitted 14 July, 2009;
originally announced July 2009.
-
Domain-wall profile in the presence of anisotropic exchange interactions: Effective on-site anisotropy
Authors:
A. O. Garcia Rodriguez,
A. Villares Ferrer,
A. O. Caldeira
Abstract:
Starting from a D-dimensional XXZ ferromagnetic Heisenberg model in an hypercubic lattice, it is demonstrated that the anisotropy in the exchange coupling constant leads to a D-dependent effective on-site anisotropy interaction often ignored for D>1. As a result the effective width of the wall depends on the dimensionality of the system. It is shown that the effective one-dimensional Hamiltonian…
▽ More
Starting from a D-dimensional XXZ ferromagnetic Heisenberg model in an hypercubic lattice, it is demonstrated that the anisotropy in the exchange coupling constant leads to a D-dependent effective on-site anisotropy interaction often ignored for D>1. As a result the effective width of the wall depends on the dimensionality of the system. It is shown that the effective one-dimensional Hamiltonian is not the one-dimensional XXZ version as assumed in previous theoretical work. We derive a new expression for the wall profile that generalizes the standard Landau-Lifshitz form. Our results are found to be in very good agreement with earlier numerical work using the Monte Carlo method. Preceding theories concerning the domain wall contribution to magnetoresistance have considered the role of D only through the modification of the density of states in the electronic band structure. This Brief Report reveals that the wall profile itself contains an additional D dependence for the case of anisotropic exchange interactions.
△ Less
Submitted 31 May, 2004; v1 submitted 5 July, 2003;
originally announced July 2003.