Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
A. Curto,
F. Cuttaia,
R. J. Davis,
J. Dick,
M. Frailis,
S. Galeotta,
A. Gregorio,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
S. Lowe,
D. Maino,
N. Mandolesi,
M. Maris,
E. Martínez-González,
P. R. Meinhold,
G. Morgante,
D. Pearson,
F. Perrotta,
G. Polenta,
T. Poutanen
, et al. (136 additional authors not shown)
Abstract:
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t…
▽ More
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
△ Less
Submitted 19 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
LFI 30 and 44 GHz receivers Back-End Modules
Authors:
E. Artal,
B. Aja,
M. L. de la Fuente,
J. P. Pascual,
A. Mediavilla,
E. Martinez-Gonzalez,
L. Pradell,
P. de Paco,
M. Bara,
E. Blanco,
E. Garcia,
R. Davis,
D. Kettle,
N. Roddis,
A. Wilkinson,
M. Bersanelli,
A. Mennella,
M. Tomasi,
R. C. Butler,
F. Cuttaia,
N. Mandolesi,
L. Stringhetti
Abstract:
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered and finally converted to DC by a detector diode. Each receiver has two identical branches following the differential scheme of the Planck radiometers. The BEM d…
▽ More
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered and finally converted to DC by a detector diode. Each receiver has two identical branches following the differential scheme of the Planck radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs P-HEMT devices, microstrip filters and Schottky diode detectors. Their manufacturing development has included elegant breadboard prototypes and finally qualification and flight model units. Electrical, mechanical and environmental tests were carried out for the characterization and verification of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules of Planck-LFI radiometers is given, with details of the tests done to determine their electrical and environmental performances. The electrical performances of the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth, equivalent noise temperature, 1/f noise and linearity are presented.
△ Less
Submitted 27 January, 2010; v1 submitted 26 January, 2010;
originally announced January 2010.
-
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
Authors:
R. J. Davis,
A. Wilkinson,
R. D. Davies,
W. F. Winder,
N. Roddis,
E. J. Blackhurst,
D. Lawson,
S. R. Lowe,
C. Baines,
M. Butlin,
A. Galtress,
D. Shepherd,
B. Aja,
E. Artal,
M. Bersanelli,
R. C. Butler,
C. Castelli,
F. Cuttaia,
O. D'Arcangelo,
T. Gaier,
R. Hoyland,
D. Kettle,
R. Leonardi,
N. Mandolesi,
A. Mennella
, et al. (6 additional authors not shown)
Abstract:
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo…
▽ More
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band.
The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Thermal susceptibility of the Planck-LFI receivers
Authors:
L Terenzi,
M J Salmon,
A Colin,
A Mennella,
G Morgante,
M Tomasi,
P Battaglia,
M Lapolla,
M Bersanelli,
R C Butler,
F Cuttaia,
O D'Arcangelo,
R Davis,
C Franceschet,
S Galeotta,
A Gregorio,
N Hughes,
P Jukkala,
D Kettle,
M Laaninen,
P Leutenegger,
R Leonardi,
N Mandolesi,
M Maris,
P Meinhold
, et al. (11 additional authors not shown)
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st .
This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on t…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st .
This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main results obtained are discussed and compared to the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck-LFI radiometers tuning
Authors:
Francesco Cuttaia,
Aniello Mennella,
Luca Stringhetti,
Michele Maris,
Luca Terenzi,
Maurizio Tomasi,
Fabrizio Villa,
Marco Bersanelli,
Christopher Reginald Butler,
Benedetta Cappellini,
Leticia Perez Cuevas,
Ocleto D'Arcangelo,
Richard Davis,
Marco Frailis,
Cristian Franceschet,
Enrico Franceschi,
Anna Gregorio,
Roger Hoyland,
Rodrigo Leonardi,
Stuart Lowe,
Nazzareno Mandolesi,
Peter Meinhold,
Luis Mendes,
Neil Roddis,
Maura Sandri
, et al. (11 additional authors not shown)
Abstract:
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st"
This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal…
▽ More
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st"
This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning philosophy, the activities and the obtained results, highlighting developments and changes occurred during test campaigns. The paper concludes with an overview of tuning performed during the satellite cryogenic test campaign (Summer 2008) and of the plans for the just started in-flight calibration.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The linearity response of the Planck-LFI flight model receivers
Authors:
A. Mennella,
F. Villa,
L. Terenzi,
F. Cuttaia,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
O. D'Arcangelo,
E. Artal,
R. Davis,
M. Frailis,
C. Franceschet,
S. Galeotta,
A. Gregorio,
N. Hughes,
P. Jukkala,
D. Kettle,
V. -H. Kilpiä,
M. Laaninen,
P. M. Lapolla,
R. Leonardi,
P. Leutenegger,
S. Lowe,
N. Mandolesi,
M. Maris
, et al. (15 additional authors not shown)
Abstract:
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best para…
▽ More
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Noise Properties of the Planck-LFI Receivers
Authors:
P. Meinhold,
R. Leonardi,
B. Aja,
E. Artal,
P. Battaglia,
M. Bersanelli,
E. Blackhurst,
C. R. Butler,
L. P. Cuevas,
F. Cuttaia,
O. D'Arcangelo,
R. Davis,
M. L. de la Fuente,
M. Frailis,
C. Franceschet,
E. Franceschi,
T. Gaier,
S. Galeotta,
A. Gregorio,
R. Hoyland,
N. Hughes,
P. Jukkala,
D. Kettle,
M. Laaninen,
P. Leutenegger
, et al. (25 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: the Planck-LFI programme
Authors:
N. Mandolesi,
M. Bersanelli,
R. C. Butler,
E. Artal,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
M. Bartelmann,
K. Bennett,
P. Bhandari,
A. Bonaldi,
J. Borrill,
M. Bremer,
C. Burigana,
R. C. Bowman,
P. Cabella,
C. Cantalupo,
B. Cappellini,
T. Courvoisier,
G. Crone,
F. Cuttaia,
L. Danese,
O. D'Arcangelo,
R. D. Davies
, et al. (118 additional authors not shown)
Abstract:
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic…
▽ More
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
△ Less
Submitted 15 January, 2010;
originally announced January 2010.
-
Offset balancing in pseudo-correlation radiometers for CMB measurements
Authors:
Aniello Mennella,
Marco Bersanelli,
Michael Seiffert,
Danielle Kettle,
Neil Roddis,
Althea Wilkinson,
Peter Meinhold
Abstract:
Radiometeric CMB measurements need to be highly stable and this stability is best obtained with differential receivers. The residual 1/f noise in the differential output is strongly dependent on the radiometer input offset which can be cancelled using various balancing strategies. In this paper we discuss a software method implemented in the Planck-LFI pseudo-correlation receivers which uses a t…
▽ More
Radiometeric CMB measurements need to be highly stable and this stability is best obtained with differential receivers. The residual 1/f noise in the differential output is strongly dependent on the radiometer input offset which can be cancelled using various balancing strategies. In this paper we discuss a software method implemented in the Planck-LFI pseudo-correlation receivers which uses a tunable "gain modulation factor, r, in the sky-load difference. Numerical simulations and experimental data show how proper tuning of the parameter r ensures a very stable differential output with knee frequencies of the order of few mHz. Various approaches to calculate r using the radiometer total power data are discussed with some examples relevant to Planck-LFI. Although the paper focuses on pseudo-correlation receivers and the examples are relative to Planck-LFI, the proposed method and its analysis is general and can be applied to a large class of differential radiometric receivers.
△ Less
Submitted 25 August, 2003; v1 submitted 31 July, 2003;
originally announced July 2003.
-
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
D. Maino,
N. Mandolesi,
G. Morgante,
L. Valenziano,
F. Villa,
T. Gaier,
M. Seiffert,
S. Levin,
C. Lawrence,
P. Meinhold,
P. Lubin,
J. Tuovinen,
J. Varis,
T. Karttaavi,
N. Hughes,
P. Jukkala,
P. Sjman,
P. Kangaslahti,
N. Roddis,
D. Kettle,
F. Winder,
E. Blackhurst
, et al. (12 additional authors not shown)
Abstract:
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing te…
▽ More
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing technique (with a tunable parameter called gain modulation factor) which is effective in reducing the radiometer susceptibility to amplifier instabilities also in presence of small non-idealities in the radiometric chain components, provided that the gain modulation factor is estimated with an accuracy of the order of 0.2%. These results have been recently confirmed by experimental laboratory measurements conducted on the LFI prototype radiometers at 30, 70 and 100 GHz.
△ Less
Submitted 7 July, 2003;
originally announced July 2003.