Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
D. Bowles,
E. Chanel,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
O. Naviliat-Cuncic,
C. B. Doorenbos,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
V. Kletzl,
J. Krempel,
B. Lauss,
T. Lefort,
A. Lejuez
, et al. (25 additional authors not shown)
Abstract:
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optim…
▽ More
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
A large 'Active Magnetic Shield' for a high-precision experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. Harris,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel
, et al. (26 additional authors not shown)
Abstract:
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static s…
▽ More
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI
Authors:
N. J. Ayres,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
M. Fertl,
P. Flaux,
W. C. Griffith,
P. G. Harris,
N. Hild,
M. Kasprzak,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
P. Mohanmurthy
, et al. (22 additional authors not shown)
Abstract:
We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polari…
▽ More
We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polarized ultracold neutrons stored in vacuum. The dominant systematic uncertainty resulting from magnetic-field gradients was controlled to an unprecedented level of approximately 4 pT/cm using an array of optically-pumped cesium vapor magnetometers and magnetic-field maps independently recorded using a dedicated measurement device. No signature of a theoretically predicted new interaction was found, and we set a new limit on the product of the scalar and the pseudoscalar couplings $g_sg_pλ^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) in a range of $5\,μ\text{m} < λ< 25\,\text{mm}$ for the monopole-dipole interaction. This new result confirms and improves our previous limit by a factor of 2.7 and provides the current tightest limit obtained with free neutrons.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
A search for neutron-to-hidden-neutron oscillations in a ultra-cold neutron beam
Authors:
G. Ban,
J. Chen,
P. -J. Chiu,
B. Clément,
M. Guigue,
T. Jenke,
P. Larue,
T. Lefort,
O. Naviliat-Cuncic,
B. Perriolat,
G. Pignol,
S. Roccia,
W. Saenz-Arevalo,
P. Schmidt-Wellenburg
Abstract:
Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Among the possible mixing processes, neutron-to-hidden-neutron oscillations have been repeatedly tested with ultra-cold neutron storage and passing-through-wall experiments in the range of small ($δm<2$ peV) and large mass splitting ($δm>10$ neV),…
▽ More
Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Among the possible mixing processes, neutron-to-hidden-neutron oscillations have been repeatedly tested with ultra-cold neutron storage and passing-through-wall experiments in the range of small ($δm<2$ peV) and large mass splitting ($δm>10$ neV), respectively. In this work, we present a new constraint in the oscillation parameter space derived from neutron disappearance in ultra-cold neutron beam experiments. The overall limit, which covers the intermediate mass-splitting range, is given by $τ_{nn'}> 1$ s for $|δm| \in [2,69]$ peV (95\% C.L.).
△ Less
Submitted 18 March, 2023;
originally announced March 2023.
-
qBounce: Systematic shifts of transition frequencies of gravitational states of ultra-cold neutrons using Ramsey gravity resonance spectroscopy
Authors:
Jakob Micko,
J. Bosina,
S. S. Cranganore,
T. Jenke,
M. Pitschmann,
S. Roccia,
R. I. P. Sedmik,
H. Abele
Abstract:
qBounce is using quantum states of ultra-cold neutrons in the gravitational field of the Earth to investigate gravitation in the micrometre range. We present current measurements taken in 2021 at the Institut Laue-Langevin (ILL) to determine energy differences of these states by mechanically induced transitions. This allows a determination of the local acceleration $g$ using a quantum measurement.…
▽ More
qBounce is using quantum states of ultra-cold neutrons in the gravitational field of the Earth to investigate gravitation in the micrometre range. We present current measurements taken in 2021 at the Institut Laue-Langevin (ILL) to determine energy differences of these states by mechanically induced transitions. This allows a determination of the local acceleration $g$ using a quantum measurement. The data presented here results in $g=9.8120(18) m/s^2$. The classical local value at the experiment is $g_c=9.8049 m/s^2$. We present an analysis of systematic effects that induces shifts of the transition frequency of order 100 mHz. The inferred value for $g$ at the experiment shows a systematic shift of $δg\approx3.9σ$.
△ Less
Submitted 20 January, 2023;
originally announced January 2023.
-
qBounce: First Measurement of the Neutron Electric Charge with a Ramsey-type GRS Experiment
Authors:
Joachim Bosina,
Hanno Filter,
Jakob Micko,
Tobias Jenke,
Mario Pitschmann,
Stéphanie Roccia,
R. I. P. Sedmik,
Hartmut Abele
Abstract:
The qBounce collaboration built over the last years a new Ramsey-type Gravitational Resonance Spectroscopy (GRS) experiment. After commissioning between 2016 and 2018, the setup was able to measure the Ramsey transitions with GRS for the first time. Here we present a search of the hypothetical charge of the neutron as an application of GRS to study nonstandard model interactions. This article will…
▽ More
The qBounce collaboration built over the last years a new Ramsey-type Gravitational Resonance Spectroscopy (GRS) experiment. After commissioning between 2016 and 2018, the setup was able to measure the Ramsey transitions with GRS for the first time. Here we present a search of the hypothetical charge of the neutron as an application of GRS to study nonstandard model interactions. This article will describe the measuring principle and the setup in detail.
△ Less
Submitted 14 January, 2023;
originally announced January 2023.
-
Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
C. B. Crawford,
M. Daum,
B. Dechenaux,
S. Emmenegger,
P. Flaux,
W. C. Griffith,
P. G. Harris,
Y. Kermaidic,
K. Kirch,
S. Komposch,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
P. Mohanmurthy,
D. Pais,
F. M. Piegsa
, et al. (13 additional authors not shown)
Abstract:
Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we repor…
▽ More
Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we report on the null result of a demonstration experiment searching for a frequency modulation of the free spin-precession signal of \magHg in a \SI{1}{\micro\tesla} magnetic field. Our search covers the axion mass range $10^{-16}~\textrm{eV} \lesssim m_a \lesssim 10^{-13}~\textrm{eV}$ and achieves a peak sensitivity to the axion-nucleon coupling of $g_{aNN} \approx 3.5 \times 10^{-6}~\textrm{GeV}^{-1}$.
△ Less
Submitted 31 March, 2023; v1 submitted 2 December, 2022;
originally announced December 2022.
-
Muonic atom spectroscopy with microgram target material
Authors:
A. Adamczak,
A. Antognini,
N. Berger,
T. E. Cocolios,
N. Deokar,
Ch. E. Düllmann,
A. Eggenberger,
R. Eichler,
M. Heines,
H. Hess,
P. Indelicato,
K. Kirch,
A. Knecht,
J. J. Krauth,
J. Nuber,
A. Ouf,
A. Papa,
R. Pohl,
E. Rapisarda,
P. Reiter,
N. Ritjoho,
S. Roccia,
M. Seidlitz,
N. Severijns,
K. von Schoeler
, et al. (4 additional authors not shown)
Abstract:
Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However,…
▽ More
Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100-bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5-μg gold target.
△ Less
Submitted 2 June, 2023; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Determination of diffusion coefficients of mercury atoms in various gases from longitudinal spin relaxation in magnetic gradients
Authors:
B. Clément,
M. Guigue,
A. Leredde,
G. Pignol,
D. Rebreyend,
S. Roccia,
S. Touati
Abstract:
We present a method to measure the binary diffusion coefficient of mercury atoms in a gas at room temperature and low pressure. It is based on the measurement of the longitudinal spin relaxation of optically pumped mercury-199 atoms in a magnetic field gradient. We provide a consistent set of diffusion coefficients for helium-3, helium-4, argon, krypton, xenon, nitrogen, carbon dioxide, oxygen, an…
▽ More
We present a method to measure the binary diffusion coefficient of mercury atoms in a gas at room temperature and low pressure. It is based on the measurement of the longitudinal spin relaxation of optically pumped mercury-199 atoms in a magnetic field gradient. We provide a consistent set of diffusion coefficients for helium-3, helium-4, argon, krypton, xenon, nitrogen, carbon dioxide, oxygen, and air.
△ Less
Submitted 19 December, 2022; v1 submitted 14 September, 2022;
originally announced September 2022.
-
The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
B. Clement,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
A. Fratangelo,
M. Fertl,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa
, et al. (19 additional authors not shown)
Abstract:
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics.…
▽ More
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1m3 below 100pT, and a field below 600pT in the entire inner volume, up to 4\,cm to the walls. The quasi-static shielding factor at 0.01\,Hz measured with a sinusoidal 2muT peak-to-peak signal is about 100,000 in all three spatial directions and rises fast with frequency to reach 10^8 above 1Hz.
△ Less
Submitted 21 June, 2022;
originally announced June 2022.
-
$n-n'$ Oscillations: Sensitivity of a first UCN beam experiment
Authors:
G. Ban,
J. Chen,
P. -J. Chiu,
B. Clément,
M. Guigue,
T. Jenke,
P. Larue,
T. Lefort,
O. Naviliat-Cuncic,
B. Perriolat,
G. Pignol,
S. Roccia,
W. Saenz-Arevalo,
P. Schmidt-Wellenburg
Abstract:
Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experime…
▽ More
Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experiments, and at larger mass-splitting in passing-through-wall experiments. In this work, we present the expected sensitivity of an experiment searching for neutron hidden neutron oscillations at intermediate mass-splitting via the application of magnetic fields in the range $B_0=30-1100$ $μ$T. This experiment was performed at the Institut-Laue-Langevin using a novel UCN counter to monitor the beam flux. The measured UCN rate and the data collection technique predict a sensitivity on the oscillation time at the level of a couple of seconds.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Spatial resolution determination of a position sensitive ultra-cold neutron detector
Authors:
B. Clément,
L. Gesson,
T. Jenke,
V. V. Nesvizhevsky,
G. Pignol,
S. Roccia,
J. -P. Scordillis
Abstract:
The study of the properties of the quantum states of bouncing neutrons requires position sensitive detection with micro-metric spatial resolution. The UCNBoX detector relies on Charge Coupled Devices (CCD) coated with a thin boron-10 conversion layer to detect neutron hits. In this paper, we present an original experimental method to determine the spatial resolution of this device using micrometri…
▽ More
The study of the properties of the quantum states of bouncing neutrons requires position sensitive detection with micro-metric spatial resolution. The UCNBoX detector relies on Charge Coupled Devices (CCD) coated with a thin boron-10 conversion layer to detect neutron hits. In this paper, we present an original experimental method to determine the spatial resolution of this device using micrometric masks. The observed resolution is $2.0\pm0.3~μ$m.
△ Less
Submitted 17 March, 2022;
originally announced March 2022.
-
Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique
Authors:
Sayani Biswas,
Lars Gerchow,
Hubertus Luetkens,
Thomas Prokscha,
Aldo Antognini,
Niklaus Berger,
Thomas Elias Cocolios,
Rugard Dressler,
Paul Indelicato,
Klaus Jungmann,
Klaus Kirch,
Andreas Knecht,
Angela Papa,
Randolf Pohl,
Maxim Pospelov,
Elisa Rapisarda,
Peter Reiter,
Narongrit Ritjoho,
Stephanie Roccia,
Nathal Severijns,
Alexander Skawran,
Stergiani Marina Vogiatzi,
Frederik Wauters,
Lorenz Willmann,
Alex Amato
Abstract:
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the avail…
▽ More
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field
Authors:
Naoto Muto,
Hartmut Abele,
Tomoko Ariga,
Joachim Bosina,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Tobias Jenke,
Hiroaki Kawahara,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Jakob Micko,
Kenji Mishima,
Naotaka Naganawa,
Mitsuhiro Nakamura,
Stéphanie Roccia,
Osamu Sato,
René I. P. Sedmik,
Yoshichika Seki,
Hirohiko M. Shimizu,
Satomi Tada,
Atsuhiro Umemoto
Abstract:
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are develo** a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a la…
▽ More
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are develo** a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.
△ Less
Submitted 26 May, 2022; v1 submitted 12 January, 2022;
originally announced January 2022.
-
Map** of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clément,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
L. Hayen,
N. Hild,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (28 additional authors not shown)
Abstract:
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the large…
▽ More
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during map** campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.
△ Less
Submitted 3 May, 2022; v1 submitted 16 March, 2021;
originally announced March 2021.
-
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
K. Kirch,
P. A. Koss,
B. Lauss,
T. Lefort,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
D. Rebreyend
, et al. (15 additional authors not shown)
Abstract:
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and v…
▽ More
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped $^{133}$Cs magnetometers and $^{199}$Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of $4\,\times\,10^{-28}\,e\cdot{\rm cm}$ in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.
△ Less
Submitted 9 July, 2021; v1 submitted 2 February, 2021;
originally announced February 2021.
-
The design of the n2EDM experiment
Authors:
N. J. Ayres,
G. Ban,
L. Bienstman,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
P. -J. Chiu,
B. Clément,
C. Crawford,
M. Daum,
B. Dechenaux,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
P. Flaux,
D. Goupillière,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch
, et al. (36 additional authors not shown)
Abstract:
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit…
▽ More
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.
△ Less
Submitted 22 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Light and Slow-Neutron Diffraction by Nanodiamond-Dispersed Nanocomposite Holographic Gratings
Authors:
Y. Tomita,
A. Kageyama,
Y. Iso,
K. Umemoto,
A. Kume,
M. Liu,
C. Pruner,
T. Jenke,
S. Roccia,
P. Geltenbort,
M. Fally,
J. Klepp
Abstract:
We demonstrate the use of nanodiamond in constructing holographic nanoparticle-polymer composite transmission gratings with large saturated refractive index modulation amplitudes at both optical and slow-neutron wavelengths, resulting in efficient control of light and slow-neutron beams. Nanodiamond possesses a high refractive index at optical wavelengths and large coherent and small incoherent sc…
▽ More
We demonstrate the use of nanodiamond in constructing holographic nanoparticle-polymer composite transmission gratings with large saturated refractive index modulation amplitudes at both optical and slow-neutron wavelengths, resulting in efficient control of light and slow-neutron beams. Nanodiamond possesses a high refractive index at optical wavelengths and large coherent and small incoherent scattering cross sections with low absorption at slow-neutron wavelengths. We describe the synthesis of nanodiamond, the preparation of photopolymerizable nanodiamond-polymer composite films, the construction of transmission gratings in nanodiamond-polymer composite films and light optical diffraction experiments. Results of slow-neutron diffraction from such gratings are also presented.
△ Less
Submitted 1 October, 2020;
originally announced October 2020.
-
A search for neutron to mirror-neutron oscillations
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
R. T. Dinani,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujic,
N. Hild,
K. Kirch,
H. -C. Koch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
A. Leredde
, et al. (18 additional authors not shown)
Abstract:
It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold…
▽ More
It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold neutron storage measurements have investigated neutron to mirror-neutron oscillations and imposed constraints on the theoretical parameters. Recently, further analysis of these ultracold neutron storage experiments has yielded statistically significant anomalous signals that may be interpreted as neutron to mirror-neutron oscillations, assuming nonzero mirror magnetic fields. The neutron electric dipole moment collaboration performed a dedicated search at the Paul Scherrer Institute and found no evidence of neutron to mirror-neutron oscillations. Thereby, the following new lower limits on the oscillation time were obtained: $τ_{nn'} > 352~$s at $B'=0$ (95% C.L.), $τ_{nn'} > 6~\text{s}$ for all $0.4~μ\text{T}<B'<25.7~μ\text{T}$ (95% C.L.), and $τ_{nn'}/\sqrt{\cosβ}>9~\text{s}$ for all $5.0~μ\text{T}<B'<25.4~μ\text{T}$ (95% C.L.), where $β$ is the fixed angle between the applied magnetic field and the local mirror magnetic field which is assumed to be bound to the Earth. These new constraints are the best measured so far around $B'\sim10~μ$T, and $B'\sim20~μ$T.
△ Less
Submitted 19 November, 2020; v1 submitted 23 September, 2020;
originally announced September 2020.
-
The measurement of the quadrupole moment of 185-Re and 187-Re from the hyperfine structure of muonic X rays
Authors:
A. Antognini,
N. Berger,
T. E. Cocolios,
R. Dressler,
R. Eichler,
A. Eggenberger,
P. Indelicato,
K. -P. Jungmann,
C. H. Keitel,
K. Kirch,
A. Knecht,
N. Michel,
J. Nuber,
N. S. Oreshkina,
A. Ouf,
A. Papa,
R. Pohl,
M. Pospelov,
E. Rapisarda,
N. Ritjoho,
S. Roccia,
N. Severijns,
A. Skawran,
S. M. Vogiatzi,
F. Wauters
, et al. (1 additional authors not shown)
Abstract:
The hyperfine splitting of the 5g -> 4f transitions in muonic 185,187-Re has been measured using high resolution HPGe detectors and compared to state-of-the-art atomic theoretical predictions. The spectroscopic quadrupole moment has been extracted using modern fitting procedures and compared to the values available in literature obtained from muonic X rays of natural rhenium. The extracted values…
▽ More
The hyperfine splitting of the 5g -> 4f transitions in muonic 185,187-Re has been measured using high resolution HPGe detectors and compared to state-of-the-art atomic theoretical predictions. The spectroscopic quadrupole moment has been extracted using modern fitting procedures and compared to the values available in literature obtained from muonic X rays of natural rhenium. The extracted values of the nuclear spectroscopic quadrupole moment are 2.07(5) barn and 1.94(5) barn, respectively for 185-Re and 187-Re. This work is part of a larger effort at the Paul Scherrer Institut towards the measurement of the nuclear charge radii of radioactive elements.
△ Less
Submitted 5 March, 2020;
originally announced March 2020.
-
Measurement of the permanent electric dipole moment of the neutron
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Burghoff,
E. Chanel,
Z. Chowdhuri,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
B. Franke,
A. Fratangelo,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten
, et al. (59 additional authors not shown)
Abstract:
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19…
▽ More
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
Data blinding for the nEDM experiment at PSI
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
P. G Harris,
Z. Grujić,
N. Hild,
J. Hommet,
B. Lauss,
T. Lefort,
Y. Lemiere,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (20 additional authors not shown)
Abstract:
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.…
▽ More
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.
Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment, as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a fake signal.
We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons of each measurement cycle.
The flexible algorithm is applied twice to the data, to provide different data to various analysis teams. This gives us the option to sequentially apply various blinding offsets for separate analysis steps with independent teams. The subtle modification of the data allows us to modify the algorithm and to produce a re-blinded data set without revealing the blinding secret. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable efforts.
△ Less
Submitted 5 October, 2020; v1 submitted 19 December, 2019;
originally announced December 2019.
-
Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
Z. Chowdhuri,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
N. Hild,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles
, et al. (35 additional authors not shown)
Abstract:
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser…
▽ More
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.
△ Less
Submitted 28 April, 2020; v1 submitted 10 December, 2019;
originally announced December 2019.
-
Magnetic field uniformity in neutron electric dipole moment experiments
Authors:
C. Abel,
N. Ayres,
T. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
C. Crawford,
P. -J. Chiu,
E. Chanel,
Z. Chowdhuri,
M. Daum,
B. Dechenaux,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
P. G. Harris,
R. Henneck,
N. Hild,
P. Iaydjiev,
S. N. Ivanov
, et al. (31 additional authors not shown)
Abstract:
Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of…
▽ More
Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of neutrons and mercury atoms. The theoretical predictions for these effects were verified by dedicated measurements with the single-chamber nEDM apparatus installed at the Paul Scherrer Institute.
△ Less
Submitted 30 August, 2019; v1 submitted 13 November, 2018;
originally announced November 2018.
-
nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
W. C. Griffith P. G. Harris,
N. Hild,
Y. Kermaidic,
K. Kirch,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
A. Leredde,
P. Mohanmurthy,
M. Musgrave,
O. Naviliat-Cuncic
, et al. (18 additional authors not shown)
Abstract:
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and sh…
▽ More
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is better than 1*10-26 ecm. This contribution summarizes in a single coherent picture the results of the most recent publications of the collaboration.
△ Less
Submitted 9 November, 2018;
originally announced November 2018.
-
The n2EDM experiment at the Paul Scherrer Institute
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. Crawford,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort
, et al. (23 additional authors not shown)
Abstract:
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI…
▽ More
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
△ Less
Submitted 27 February, 2019; v1 submitted 6 November, 2018;
originally announced November 2018.
-
Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations
Authors:
C. Abel,
N. Ayres,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffth,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
A. Leredde,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
M. Rawlik
, et al. (11 additional authors not shown)
Abstract:
The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have…
▽ More
The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have been further analyzed by Berezhiani et al.(2009-2017), and signals, compatible with $n-n'$ oscillations in the presence of mirror magnetic fields, have been reported. The Neutron Electric Dipole Moment Collaboration based at the Paul Scherrer Institute performed a new series of experiments to further test these signals. In this paper, we describe and motivate our choice of run configurations with an optimal filling time of $29~$s, storage times of $180~$s and $380~$s, and applied magnetic fields of $10~μ$T and $20~μ$T. The choice of these run configurations ensures a reliable overlap in settings with the previous efforts and also improves the sensitivity to test the signals. We also elaborate on the technique of normalizing the neutron counts, making such a counting experiment at the ultra-cold neutron source at the Paul Scherrer Institute possible. Furthermore, the magnetic field characterization to meet the requirements of this $n-n'$ oscillation search is demonstrated. Finally, we show that this effort has a statistical sensitivity comparable to the current leading constraints for $n-n'$ oscillations.
△ Less
Submitted 19 December, 2019; v1 submitted 5 November, 2018;
originally announced November 2018.
-
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Authors:
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
W. Heil,
M. Horras,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozel,
J. Krempel,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
G. Pignol,
F. M. Piegsa,
P. Prashanth,
G. Quéméner,
M. Rawlik,
D. Rebreyend
, et al. (9 additional authors not shown)
Abstract:
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of…
▽ More
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Daum,
M. Fairbairn,
V. V. Flambaum,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujić,
P. G. Harris,
N. Hild,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
P. A. Koss,
A. Kozela
, et al. (23 additional authors not shown)
Abstract:
We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range…
▽ More
We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. Our null result sets the first laboratory constraints on the coupling of axion dark matter to gluons, which improve on astrophysical limits by up to 3 orders of magnitude, and also improves on previous laboratory constraints on the axion coupling to nucleons by up to a factor of 40.
△ Less
Submitted 21 August, 2017;
originally announced August 2017.
-
Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute
Authors:
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
P. Geltenbort,
W. C. Griffith,
V. Hélaine,
R. Henneck,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
M. Musgrave,
O. Naviliat-Cuncic,
F. M. Piegsa,
E. Pierre,
G. Pignol,
G. Quéméner
, et al. (10 additional authors not shown)
Abstract:
This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-dep…
▽ More
This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.
△ Less
Submitted 23 June, 2016;
originally announced June 2016.
-
A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
Authors:
J. M. Pendlebury,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss
, et al. (25 additional authors not shown)
Abstract:
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calcula…
▽ More
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL).
This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.
△ Less
Submitted 13 October, 2015; v1 submitted 15 September, 2015;
originally announced September 2015.
-
A highly stable atomic vector magnetometer based on free spin precession
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
Z. D. Grujic,
L. Hayen,
V. Helaine,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa,
P. N. Prashanth,
G. Quemener,
M. Rawlik,
D. Ries
, et al. (9 additional authors not shown)
Abstract:
We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scal…
▽ More
We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 $μ$rad for integration times from 10 s up to 2000 s.
△ Less
Submitted 30 July, 2015;
originally announced July 2015.
-
Gravitational Depolarization of Ultracold Neutrons: Comparison with Data
Authors:
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
W. Heil,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (25 additional authors not shown)
Abstract:
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency…
▽ More
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.
△ Less
Submitted 26 August, 2015; v1 submitted 22 June, 2015;
originally announced June 2015.
-
Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy
Authors:
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
V. Hélaine,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière
, et al. (23 additional authors not shown)
Abstract:
We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method…
▽ More
We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCN of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of $1.1~\text{pT/cm}$. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.
△ Less
Submitted 8 September, 2015; v1 submitted 1 June, 2015;
originally announced June 2015.
-
Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field
Authors:
S. Afach,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
Z. Grujic,
P. G. Harris,
W. Heil,
V. Hélaine,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (24 additional authors not shown)
Abstract:
We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to a…
▽ More
We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to an electric dipole moment (EDM) signal, although unlike an EDM this effect is P- and T-conserving. We have used a neutron magnetic resonance EDM spectrometer, featuring a mercury co-magnetometer and an array of external cesium magnetometers, to measure the shift as a function of the applied magnetic field gradient. Our results are in good agreement with theoretical expectations.
△ Less
Submitted 3 August, 2015; v1 submitted 30 March, 2015;
originally announced March 2015.
-
A device for simultaneous spin analysis of ultracold neutrons
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
R. Henneck,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa
, et al. (15 additional authors not shown)
Abstract:
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons.…
▽ More
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.
△ Less
Submitted 12 October, 2015; v1 submitted 24 February, 2015;
originally announced February 2015.
-
Constraining interactions mediated by axion-like particles with ultracold neutrons
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
V. Hélaine,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa,
G. Pignol
, et al. (13 additional authors not shown)
Abstract:
We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the P…
▽ More
We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the Paul Scherrer Institute. A possible coupling between freely precessing polarized neutron spins and unpolarized nucleons of the wall material can be investigated by searching for a tiny change of the precession frequencies of neutron and mercury spins. Such a frequency change can be interpreted as a consequence of a short range spin-dependent interaction that could possibly be mediated by axions or axion-like particles. The interaction strength is proportional to the CP violating product of scalar and pseudoscalar coupling constants $g_Sg_P$. Our result confirms limits from complementary experiments with spin-polarized nuclei in a model-independent way. Limits from other neutron experiments are improved by up to two orders of magnitude in the interaction range of $10^{-6}<λ<10^{-4}$ m.
△ Less
Submitted 11 December, 2014;
originally announced December 2014.
-
A measurement of the neutron to 199Hg magnetic moment ratio
Authors:
S. Afach,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
Z. Grujic,
P. G. Harris,
W. Heil,
V. Hélaine,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
A. Knecht
, et al. (29 additional authors not shown)
Abstract:
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.
△ Less
Submitted 31 October, 2014; v1 submitted 30 October, 2014;
originally announced October 2014.
-
Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute
Authors:
S. Afach,
G. Bison,
K. Bodek,
F. Burri,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
Z. Grujic,
V. Helaine,
R. Henneck,
M. Kasprzak,
K. Kirch,
H. -C. Koch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
M. Meier,
O. Naviliat-Cuncic,
F. M. Piegsa,
G. Pignol,
C. Plonka-Spehr,
P. N. Prashanth
, et al. (12 additional authors not shown)
Abstract:
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magn…
▽ More
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the nEDM measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.
△ Less
Submitted 28 August, 2014;
originally announced August 2014.
-
Experimental study of 199Hg spin anti-relaxation coatings
Authors:
Z. Chowdhuri,
M. Fertl,
M. Horras,
K. Kirch,
J. Krempel,
B. Lauss,
A. Mtchedlishvili,
D. Rebreyend,
S. Roccia,
P. Schmidt-Wellenburg,
G. Zsigmond
Abstract:
We report on a comparison of spin relaxation rates in a $^{199}$Hg magnetometer using different wall coatings. A compact mercury magnetometer was built for this purpose. Glass cells coated with fluorinated materials show longer spin coherence times than if coated with their hydrogenated homologues. The longest spin relaxation time of the mercury vapor was measured with a fluorinated paraffin wall…
▽ More
We report on a comparison of spin relaxation rates in a $^{199}$Hg magnetometer using different wall coatings. A compact mercury magnetometer was built for this purpose. Glass cells coated with fluorinated materials show longer spin coherence times than if coated with their hydrogenated homologues. The longest spin relaxation time of the mercury vapor was measured with a fluorinated paraffin wall coating.
△ Less
Submitted 4 September, 2013; v1 submitted 8 May, 2013;
originally announced May 2013.
-
Electric dipole moment searches: reexamination of frequency shifts for particles in traps
Authors:
Guillaume Pignol,
Stephanie Roccia
Abstract:
In experiments searching for a nonzero electric dipole moment of trapped particles, frequency shifts correlated with an applied electric field can be interpreted as a false signal. One such effect, referred to as the geometric phase effect, is known to occur in a magnetic field that is nonperfectly homogeneous. The increase in sensitivity of experiments demands improved theoretical description of…
▽ More
In experiments searching for a nonzero electric dipole moment of trapped particles, frequency shifts correlated with an applied electric field can be interpreted as a false signal. One such effect, referred to as the geometric phase effect, is known to occur in a magnetic field that is nonperfectly homogeneous. The increase in sensitivity of experiments demands improved theoretical description of this effect. In the case of fast particles, like atoms at room temperature and low pressure, the validity of established theories was limited to a cylindrical confinement cell in a uniform gradient with cylindrical symmetry. We develop a more general theory valid for an arbitrary shape of the magnetic field as well as for arbitrary geometry of the confinement cell. Our improved theory is especially relevant for experiments measuring the neutron electric dipole moment with an atomic comagnetometer. In this context, we have reproduced and extended earlier numerical studies of the geometric phase effect induced by localized magnetic impurities.
△ Less
Submitted 2 May, 2012; v1 submitted 3 January, 2012;
originally announced January 2012.
-
An Improved Search for the Neutron Electric Dipole Moment
Authors:
M. Burghoff,
A. Schnabel,
G. Ban,
T. Lefort,
Y. Lemiere,
O. Naviliat-Cuncic,
E. Pierre,
G. Quemener,
J. Zejma,
M. Kasprzak,
P. Knowles,
A. Weis,
G. Pignol,
D. Rebreyend,
S. Afach,
G. Bison,
J. Becker,
N. Severijns,
S. Roccia,
C. Plonka-Spehr,
J. Zennerz,
W. Heil,
H. C. Koch,
A. Kraft,
T. Lauer
, et al. (12 additional authors not shown)
Abstract:
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved…
▽ More
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
Hyperfine Field and Hyperfine Anomalies of Copper Impurities in Iron
Authors:
V. V. Golovko,
F. Wauters,
S. Cottenier,
M. Breitenfeldt,
V. De Leebeeck,
S. Roccia,
G. Soti,
M. Tandecki,
E. Traykov,
S. Van Gorp,
D. Zákoucký,
N. Severijns
Abstract:
A new value for the hyperfine magnetic field of copper impurities in iron is obtained by combining resonance frequencies from experiments involving β-NMR on oriented nuclei on 59-Cu, 69-Cu, and 71-Cu with magnetic moment values from collinear laser spectroscopy measurements on these isotopes. The resulting value, i.e., Bhf(CuFe) = -21.794(10) T, is in agreement with the value adopted until now but…
▽ More
A new value for the hyperfine magnetic field of copper impurities in iron is obtained by combining resonance frequencies from experiments involving β-NMR on oriented nuclei on 59-Cu, 69-Cu, and 71-Cu with magnetic moment values from collinear laser spectroscopy measurements on these isotopes. The resulting value, i.e., Bhf(CuFe) = -21.794(10) T, is in agreement with the value adopted until now but is an order of magnitude more precise. It is consistent with predictions from ab initio calculations. Comparing the hyperfine field values obtained for the individual isotopes, the hyperfine anomalies in Fe were determined to be 59Δ69=0.15(9)% and 71Δ69=0.07(11)%.
△ Less
Submitted 29 July, 2011;
originally announced July 2011.
-
The half-life of $^{221}$Fr in Si and Au at 4K and at mK temperatures
Authors:
F. Wauters,
B. Verstichel,
M. Breitenfeldt,
V. De Leebeeck,
V. Yu. Kozlov,
I. Kraev,
S. Roccia,
G. Soti,
M. Tandecki,
E. Traykov,
S. Van Gorp,
D. Z'akouck'y,
N. Severijns
Abstract:
The half-life of the $α$ decaying nucleus $^{221}$Fr was determined in different environments, i.e. embedded in Si at 4 K, and embedded in Au at 4 K and about 20 mK. No differences in half-life for these different conditions were observed within 0.1%. Furthermore, we quote a new value for the absolute half-life of $^{221}$Fr of t$_{1/2}$ = 286.1(10) s, which is of comparable precision to the mos…
▽ More
The half-life of the $α$ decaying nucleus $^{221}$Fr was determined in different environments, i.e. embedded in Si at 4 K, and embedded in Au at 4 K and about 20 mK. No differences in half-life for these different conditions were observed within 0.1%. Furthermore, we quote a new value for the absolute half-life of $^{221}$Fr of t$_{1/2}$ = 286.1(10) s, which is of comparable precision to the most precise value available in literature.
△ Less
Submitted 29 October, 2010;
originally announced October 2010.
-
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Authors:
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
P. Fierlinger,
B. Franke,
E. Gutsmiedl,
W. Heil,
R. Henneck,
M. Horras,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Kraft,
A. Knecht,
P. Knowles,
A. Kozela,
T. Lauer,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (16 additional authors not shown)
Abstract:
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in…
▽ More
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.
△ Less
Submitted 30 September, 2010;
originally announced September 2010.
-
New constraints on Lorentz invariance violation from the neutron electric dipole moment
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
P. G. Harris,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
A. Kozela,
F. Kuchler,
B. Lauss,
T. Lefort,
Y. Lemière
, et al. (18 additional authors not shown)
Abstract:
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrai…
▽ More
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrain such a modulation to $d_{12} < 15 \times 10^{-25} \ e\,{\rm cm}$ and $d_{24} < 10 \times 10^{-25} \ e\,{\rm cm}$ at 95~\% C.L. The result translates into a limit on the energy scale for this type of Lorentz violation effect at the level of ${\cal E}_{LV} > 10^{10}$~GeV.
△ Less
Submitted 25 June, 2010;
originally announced June 2010.
-
Precision measurements of the $^{60}$Co $β$-asymmetry parameter in search for tensor currents in weak interactions
Authors:
F. Wauters,
I. S. Kraev,
D. Zákoucký,
M. Beck,
M. Breitenfeldt,
V. De Leebeeck,
V. V. Golovko,
V. Yu. Kozlov,
T. Phalet,
S. Roccia,
G. Soti,
M. Tandecki,
I. S. Towner,
E. Traykov,
S. Van Gorp,
N. Severijns
Abstract:
The $β$-asymmetry parameter $\widetilde{A}$ for the Gamow-Teller decay of $^{60}$Co was measured by polarizing the radioactive nuclei with the brute force low-temperature nuclear-orientation method. The $^{60}$Co activity was cooled down to milliKelvin temperatures in a $^3$He-$^4$He dilution refrigerator in an external 13 T magnetic field. The $β$ particles were observed by a 500 $μm$ thick Si PI…
▽ More
The $β$-asymmetry parameter $\widetilde{A}$ for the Gamow-Teller decay of $^{60}$Co was measured by polarizing the radioactive nuclei with the brute force low-temperature nuclear-orientation method. The $^{60}$Co activity was cooled down to milliKelvin temperatures in a $^3$He-$^4$He dilution refrigerator in an external 13 T magnetic field. The $β$ particles were observed by a 500 $μm$ thick Si PIN diode operating at a temperature of about 10 K in a magnetic field of 0.6 T. Extensive GEANT4 Monte-Carlo simulations were performed to gain control over the systematic effects. Our result, $\widetilde{A} = -1.014(12)_{stat}(16)_{syst}$, is in agreement with the Standard-Model value of $-0.987(9)$, which includes recoil-order corrections that were addressed for the first time for this isotope. Further, it enables limits to be placed on possible tensor-type charged weak currents as well as other physics beyond the Standard Model.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
-
Neutron to Mirror-Neutron Oscillations in the Presence of Mirror Magnetic Fields
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
K. Bodek,
M. Daum,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
E. Gutsmiedl,
P. G. Harris,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
A. Kozela,
F. Kuchler,
M. Kuźniak,
T. Lauer,
B. Lauss
, et al. (21 additional authors not shown)
Abstract:
We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 1…
▽ More
We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 12.0 s at 95% C.L. for any B' between 0 and 12.5 uT.
△ Less
Submitted 18 August, 2009; v1 submitted 26 May, 2009;
originally announced May 2009.
-
Test of Lorentz invariance with spin precession of ultracold neutrons
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
E. Gutsmiedl,
P. G. Harris,
W. Heil,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
A. Kozela,
F. Kuchler,
M. Kuźniak
, et al. (21 additional authors not shown)
Abstract:
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This resu…
▽ More
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron $|g_n| < 0.3 $eV/$c^2$ m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit $|g_n| < 3 \times 10^{-4} $eV/$c^2 $m.
△ Less
Submitted 23 July, 2009; v1 submitted 20 May, 2009;
originally announced May 2009.
-
An Improved Neutron Electric Dipole Moment Experiment
Authors:
M. Kuźniak,
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
M. Daum,
K. Eberhardt,
P. Fierlinger,
E. Gutsmiedl,
G. Hampel,
W. Heil,
R. Henneck,
N. Khomutov,
K. Kirch,
St. Kistryn,
S. Knappe-Grueneberg,
A. Knecht,
P. Knowles,
J. V. Kratz,
T. Lauer,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (19 additional authors not shown)
Abstract:
A new measurement of the neutron EDM, using Ramsey's method of separated oscillatory fields, is in preparation at the new high intensity source of ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland (PSI). The existence of a non-zero nEDM would violate both parity and time reversal symmetry and, given the CPT theorem, might lead to a discovery of new CP violating mech…
▽ More
A new measurement of the neutron EDM, using Ramsey's method of separated oscillatory fields, is in preparation at the new high intensity source of ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland (PSI). The existence of a non-zero nEDM would violate both parity and time reversal symmetry and, given the CPT theorem, might lead to a discovery of new CP violating mechanisms. Already the current upper limit for the nEDM (|d_n|<2.9E-26 e.cm) constrains some extensions of the Standard Model.
The new experiment aims at a two orders of magnitude reduction of the experimental uncertainty, to be achieved mainly by (1) the higher UCN flux provided by the new PSI source, (2) better magnetic field control with improved magnetometry and (3) a double chamber configuration with opposite electric field directions.
The first stage of the experiment will use an upgrade of the RAL/Sussex/ILL group's apparatus (which has produced the current best result) moved from Institut Laue-Langevin to PSI. The final accuracy will be achieved in a further step with a new spectrometer, presently in the design phase.
△ Less
Submitted 5 August, 2008; v1 submitted 30 June, 2008;
originally announced June 2008.