-
$^{171}$Yb$^+$ optical clock with $2.2\times 10^{-18}$ systematic uncertainty and absolute frequency measurements
Authors:
Alexandra Tofful,
Charles F. A. Baynham,
E. Anne Curtis,
Adam O. Parsons,
Billy I. Robertson,
Marco Schioppo,
Jacob Tunesi,
Helen S. Margolis,
Richard J. Hendricks,
Josh Whale,
Richard C. Thompson,
Rachel M. Godun
Abstract:
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of $2.2\times 10^{-18}$. Furthermore, the absolute frequency of the…
▽ More
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of $2.2\times 10^{-18}$. Furthermore, the absolute frequency of the E3 transition of the $^{171}$Yb$^+$ ion was measured between 2019 and 2023 via a link to International Atomic Time (TAI) and against the local caesium fountain NPL-CsF2. The absolute frequencies were measured with fractional standard uncertainties between $3.7 \times 10^{-16}$ and $1.1 \times 10^{-15}$, and all were in agreement with the 2021 BIPM recommended frequency.
△ Less
Submitted 21 March, 2024;
originally announced March 2024.
-
An ion trap design for a space-deployable strontium-ion optical clock
Authors:
Alessio Spampinato,
Jonathan Stacey,
Sean Mulholland,
Billy I. Robertson,
Hugh A. Klein,
Guilong Huang,
Geoffrey P. Barwood,
Patrick Gill
Abstract:
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and po…
▽ More
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and portable devices at this capability level. In this paper we discuss the design of a physics package for a compact laser-cooled 88Sr+ optical clock that would, with further development, be suitable for space deployment. We review the design parameters to target a relative frequency uncertainty at the low parts in 10^18 with this system. We then explain the results of finite element modelling to simulate the response of the ion trap and vacuum chamber to vibration, shock and thermal conditions expected during launch and space deployment. Additionally, an electrostatic model has been developed to investigate the relationship between the ion trap geometrical tolerances and the trap** efficiency. We present the results from these analyses that have led to the design of a more robust prototype ready for experimental testing.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Analysis of atomic-clock data to constrain variations of fundamental constants
Authors:
Nathaniel Sherrill,
Adam O. Parsons,
Charles F. A. Baynham,
William Bowden,
E. Anne Curtis,
Richard Hendricks,
Ian R. Hill,
Richard Hobson,
Helen S. Margolis,
Billy I. Robertson,
Marco Schioppo,
Krzysztof Szymaniec,
Alexandra Tofful,
Jacob Tunesi,
Rachel M. Godun,
Xavier Calmet
Abstract:
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio,…
▽ More
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio, $μ$. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
△ Less
Submitted 15 December, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Measuring the stability of fundamental constants with a network of clocks
Authors:
G. Barontini,
L. Blackburn,
V. Boyer,
F. Butuc-Mayer,
X. Calmet,
J. R. Crespo Lopez-Urrutia,
E. A. Curtis,
B. Darquie,
J. Dunningham,
N. J. Fitch,
E. M. Forgan,
K. Georgiou,
P. Gill,
R. M. Godun,
J. Goldwin,
V. Guarrera,
A. C. Harwood,
I. R. Hill,
R. J. Hendricks,
M. Jeong,
M. Y. H. Johnson,
M. Keller,
L. P. Kozhiparambil Sajith,
F. Kuipers,
H. S. Margolis
, et al. (19 additional authors not shown)
Abstract:
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the…
▽ More
The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the goal of the recently launched QSNET project: A network of clocks for measuring the stability of fundamental constants. QSNET will include state-of-the-art atomic clocks, but will also develop next-generation molecular and highly charged ion clocks with enhanced sensitivity to variations of fundamental constants. We describe the technological and scientific aims of QSNET and evaluate its expected performance. We show that in the range of parameters probed by QSNET, either we will discover new physics, or we will impose new constraints on violations of fundamental symmetries and a range of theories beyond the Standard Model, including dark matter and dark energy models.
△ Less
Submitted 11 May, 2022; v1 submitted 20 December, 2021;
originally announced December 2021.
-
Detection of Applied and Ambient Forces with a Matterwave Magnetic-Gradiometer
Authors:
Billy I. Robertson,
Andrew R. MacKellar,
James Halket,
Anna Gribbon,
Jonathan D. Pritchard,
Aidan S. Arnold,
Erling Riis,
Paul F. Griffin
Abstract:
An atom interferometer using a Bose-Einstein condensate of $^{87}$Rb atoms is utilized for the measurement of magnetic field gradients. Composite optical pulses are used to construct a spatially symmetric Mach-Zehnder geometry. Using a biased interferometer we demonstrate the ability to measure small residual forces in our system at the position of the atoms. These are a residual magnetic field gr…
▽ More
An atom interferometer using a Bose-Einstein condensate of $^{87}$Rb atoms is utilized for the measurement of magnetic field gradients. Composite optical pulses are used to construct a spatially symmetric Mach-Zehnder geometry. Using a biased interferometer we demonstrate the ability to measure small residual forces in our system at the position of the atoms. These are a residual magnetic field gradient of 15$\pm$2 mG/cm and and an inertial acceleration of 0.08$\pm$0.02 m/s$^2$. Our method has important applications in the calibration of precision measurement devices and the reduction of systematic errors.
△ Less
Submitted 3 November, 2017; v1 submitted 24 July, 2017;
originally announced July 2017.