-
On-chip fully reconfigurable Artificial Neural Network in 16 nm FinFET for Positron Emission Tomography
Authors:
Andrada Muntean,
Yonatan Shoshan,
Slava Yuzhaninov,
Emanuele Ripiccini,
Claudio Bruschini,
Alexander Fish,
Edoardo Charbon
Abstract:
Smarty is a fully-reconfigurable on-chip feed-forward artificial neural network (ANN) with ten integrated time-to-digital converters (TDCs) designed in a 16 nm FinFET CMOS technology node. The integration of TDCs together with an ANN aims to reduce system complexity and minimize data throughput requirements in positron emission tomography (PET) applications. The TDCs have an average LSB of 53.5 ps…
▽ More
Smarty is a fully-reconfigurable on-chip feed-forward artificial neural network (ANN) with ten integrated time-to-digital converters (TDCs) designed in a 16 nm FinFET CMOS technology node. The integration of TDCs together with an ANN aims to reduce system complexity and minimize data throughput requirements in positron emission tomography (PET) applications. The TDCs have an average LSB of 53.5 ps. The ANN is fully reconfigurable, the user being able to change its topology as desired within a set of constraints. The chip can execute 363 MOPS with a maximum power consumption of 1.9 mW, for an efficiency of 190 GOPS/W. The system performance was tested in a coincidence measurement setup interfacing Smarty with two groups of five 4 mm x 4 mm analog silicon photomultipliers (A-SiPMs) used as inputs for the TDCs. The ANN successfully distinguished between six different positions of a radioactive source placed between the two photodetector arrays by solely using the TDC timestamps.
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
Sub-10 ps Minimum Ionizing Particle Detection with Geiger-Mode APDs
Authors:
Francesco Gramuglia,
Emanuele Ripiccini,
Carlo Alberto Fenoglio,
Ming-Lo Wu,
Lorenzo Paolozzi,
Claudio Bruschini,
Edoardo Charbon
Abstract:
Major advances in silicon pixel detectors, with outstanding timing performance, have recently attracted significant attention in the community. In this work we present and discuss the use of state-of-the-art Geiger-mode APDs, also known as single-photon avalanche diodes (SPADs), for the detection of minimum ionizing particles (MIPs) with best-in-class timing resolution. The SPADs were implemented…
▽ More
Major advances in silicon pixel detectors, with outstanding timing performance, have recently attracted significant attention in the community. In this work we present and discuss the use of state-of-the-art Geiger-mode APDs, also known as single-photon avalanche diodes (SPADs), for the detection of minimum ionizing particles (MIPs) with best-in-class timing resolution. The SPADs were implemented in standard CMOS technology and integrated with on-chip quenching and recharge circuitry. Two devices in coincidence allowed to measure the time-of-flight of 180 GeV/c momentum pions with a coincidence time resolution of 22 ps FWHM (9.5 ps Gaussian sigma). Radiation hardness measurements, also presented here, highlight the suitability of this family of devices for a wide range of high energy physics (HEP) applications.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Detailed analysis of chemical corrosion of ultra-thin wires used in drift chamber detectors
Authors:
A. M. Baldini,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
G. Cocciolo,
A. Corvaglia,
F. Cuna,
M. Francesconi,
L. Galli,
F. Grancagnolo,
M. Grassi,
R. Ishak,
M. Meucci,
D. Nicoló,
M. Panareo,
A. Papa,
A. Pepino,
F. Raffaelli,
F. Renga,
E. Ripiccini,
G. Signorelli,
G. F. Tassielli,
R. Valentini
, et al. (2 additional authors not shown)
Abstract:
Ultra-thin metallic anodic and cathodic wires are frequently employed in low-mass gaseous detectors for precision experiments, where the amount of material crossed by charged particles must be minimised. We present here the results of an analysis of the mechanical stress and chemical corrosion effects observed in $40$ and $50~{\rm{μm}}$ diameter silver plated aluminum wires mounted within the volu…
▽ More
Ultra-thin metallic anodic and cathodic wires are frequently employed in low-mass gaseous detectors for precision experiments, where the amount of material crossed by charged particles must be minimised. We present here the results of an analysis of the mechanical stress and chemical corrosion effects observed in $40$ and $50~{\rm{μm}}$ diameter silver plated aluminum wires mounted within the volume of the MEG\,II drift chamber, which caused the breaking of about one hundred wires (over a total of $\approx 12000$). This analysis is based on the accurate inspection of the broken wires by means of optical and electronic microscopes and on a detailed recording of all breaking accidents. We present a simple empirical model which relates the number of broken wires to their exposure time to atmospheric humidity and to their mechanical tension, which is necessary for mechanical stability in the presence of electrostatic fields of several kV/cm. Finally we discuss how wire breakings can be avoided or at least strongly reduced by operating in controlled atmosphere during the mounting stages of the wires within the drift chamber and by choosing a $25\,\%$ thicker wire diameter, which has very small effects on the detector resolution and efficiency and can be obtained by using a safer fabrication technique.
△ Less
Submitted 22 November, 2021; v1 submitted 31 August, 2021;
originally announced August 2021.
-
The TT-PET Data Acquisition and Trigger System
Authors:
Y. Bandi,
Y. Favre,
D. Ferrere,
D. Forshaw,
R. Hanni,
D. Hayakawa,
G. Iacobucci,
P. Lutz,
A. Miucci,
L. Paolozzi,
E. Ripiccini,
C. Tognina,
P. Valerio,
M. Weber
Abstract:
This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal to each sensor in order to measure time differences of better than 30 ps. This clock distribution is measured to have a jitter of less than 4 ps at the sensors…
▽ More
This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal to each sensor in order to measure time differences of better than 30 ps. This clock distribution is measured to have a jitter of less than 4 ps at the sensors. Collected data is locally processed before being forwarded to storage. Data flow as well as control, configuration and monitoring aspects are are also addressed.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Module concept and thermo-mechanical studies of the silicon-based TT-PET small-animal scanner
Authors:
Didier Ferrere,
Yves Bandi,
Frank Cadoux,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Sebastien Michal,
Antonio Miucci,
Marzio Nessi,
Lorenzo Paolozzi,
Emanuele Ripiccini,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is develo** an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2…
▽ More
The TT-PET collaboration is develo** an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity for precise depth-of-interaction measurement. In this paper we present the results of simulation studies for the expected data rate, time-of-flight and spatial resolution, as well as the performance of image reconstruction with and without the use of timing information.
△ Less
Submitted 12 March, 2019; v1 submitted 29 November, 2018;
originally announced December 2018.
-
Expected performance of the TT-PET scanner
Authors:
Emanuele Ripiccini,
Daiki Hayakawa,
Giuseppe Iacobucci,
Marzio Nessi,
Elzbieta Nowak,
Lorenzo Paolozzi,
Osman Ratib,
Pierpaolo Valerio,
Daniele Vitturini
Abstract:
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers of high-Z photon-converter and 100 $\mathrm{μm}$ thick silicon sensors, to achieve a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2…
▽ More
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers of high-Z photon-converter and 100 $\mathrm{μm}$ thick silicon sensors, to achieve a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity, with precise depth-of-interaction measurement. In this paper we present the results of the Monte Carlo studies for the expected data rate, time resolution on the TOF measurements, spatial resolution and image reconstruction with and without the use of the timing information. Most of the studies have been performed according to the international standards used to assess the performance of small-animal PET system.
△ Less
Submitted 29 November, 2018;
originally announced November 2018.
-
The Quest for $μ\to e γ$ and its Experimental Limiting Factors at Future High Intensity Muon Beams
Authors:
Francesco Renga,
Gianluca Cavoto,
Angela Papa,
Emanuele Ripiccini,
Cecilia Voena
Abstract:
The search for the Lepton Flavor Violating decay $μ\to e γ$ exploits the most intense continuous muon beams, which can currently deliver $\sim 10^8$ muons per second. In the next decade, accelerator upgrades are expected in various facilities, making it feasible to have continuous beams with an intensity of $10^9$ or even $10^{10}$ muons per second. We investigate the experimental limiting factors…
▽ More
The search for the Lepton Flavor Violating decay $μ\to e γ$ exploits the most intense continuous muon beams, which can currently deliver $\sim 10^8$ muons per second. In the next decade, accelerator upgrades are expected in various facilities, making it feasible to have continuous beams with an intensity of $10^9$ or even $10^{10}$ muons per second. We investigate the experimental limiting factors that will define the ultimate performances, and hence the sensitivity, in the search for $μ\to e γ$ with a continuous beam at these extremely high rates. We then consider some conceptual detector designs and evaluate the corresponding sensitivity as a function of the beam intensity.
△ Less
Submitted 29 November, 2018;
originally announced November 2018.
-
Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project
Authors:
Lorenzo Paolozzi,
Yves Bandi,
Roberto Cardarelli,
Stephane Debieux,
Yannick Favre,
Didier Ferrere,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Mehmet Kaynak,
Antonio Miucci,
Marzio Nessi,
Emanuele Ripiccini,
Holger Ruecker,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage…
▽ More
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9 % and a time resolution down to 110 ps.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
A monolithic ASIC demonstrator for the Thin Time-of-Flight PET scanner
Authors:
Pierpaolo Valerio,
Roberto Cardarelli,
Giuseppe Iacobucci,
Lorenzo Paolozzi,
Emanuele Ripiccini,
Daiki Hayakawa,
Salvatore Bruno,
Alessandro Caltabiano,
Mehmet Kaynak,
Holger Rueker,
Marzio Nessi
Abstract:
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-b…
▽ More
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-based front-end per channel, integrated on the same 100 $μ m$ thick die. The target timing resolution is 30 ps RMS for electrons from the conversion of 511 keV photons. A novel synchronization scheme using a patent-pending TDC is used to allow the synchronization of 1.6 million channels across almost 2000 different chips at picosecond-level. A full-featured demonstrator chip with a 3x10 matrix of 500x500 $μ m^{2}$ pixels was produced to validate each block. Its design and experimental results are presented here.
△ Less
Submitted 26 November, 2018;
originally announced November 2018.
-
Gas Distribution and Monitoring for the Drift Chamber of the MEG-II Experiment
Authors:
A. M. Baldini,
E. Baracchini,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
M. Francesconi,
L. Galli,
F. Grancagnolo,
M. Grassi,
M. Hildebrandt,
V. Martinelli,
M. Meucci,
D. Nicolò,
M. Panareo,
A. Papa,
A. Pepino,
B. Pruneti,
F. Raffaelli,
F. Renga,
E. Ripiccini,
G. Signorelli,
G. F. Tassielli,
C. Voena
Abstract:
The reconstruction of the positron trajectory in the MEG-II experiment searching for the $μ^+ \to e^+ γ$ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitore…
▽ More
The reconstruction of the positron trajectory in the MEG-II experiment searching for the $μ^+ \to e^+ γ$ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitored. In this paper we describe the strategies adopted to meet the requirements imposed by the target sensitivity of MEG-II, including the construction and commissioning of a small chamber for an online monitoring of the gas quality.
△ Less
Submitted 23 April, 2018;
originally announced April 2018.
-
Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project
Authors:
L. Paolozzi,
Y. Bandi,
M. Benoit,
R. Cardarelli,
S. Débieux,
D. Forshaw,
D. Hayakawa,
G. Iacobucci,
M. Kaynak,
A. Miucci,
M. Nessi,
O. Ratib,
E. Ripiccini,
H. Rücker,
P. Valerio,
M. Weber
Abstract:
The TT-PET collaboration is develo** a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. Th…
▽ More
The TT-PET collaboration is develo** a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e- RMS and a pulse rise time of less than 2 ns, in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps.
△ Less
Submitted 6 February, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
The design of the MEG II experiment
Authors:
A. M. Baldini,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
G. Cocciolo,
A. Corvaglia,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
M. Francesconi,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
D. N. Grigoriev,
M. Hildebrandt
, et al. (55 additional authors not shown)
Abstract:
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation…
▽ More
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.
△ Less
Submitted 15 January, 2018;
originally announced January 2018.
-
The Quest for $μ\to e γ$ and its Experimental Limiting Factors at Future High Intensity Muon Beams
Authors:
G. Cavoto,
A. Papa,
F. Renga,
E. Ripiccini,
C. Voena
Abstract:
The search for the Lepton Flavor Violating decay mu into e gamma will reach an unprecedented level of sensitivity within the next five years thanks to the MEG-II experiment. This experiment will take data at the Paul Scherrer Institut where continuous muon beams are delivered at a rate of about 10^8 muons per second. On the same time scale, accelerator upgrades are expected in various facilities,…
▽ More
The search for the Lepton Flavor Violating decay mu into e gamma will reach an unprecedented level of sensitivity within the next five years thanks to the MEG-II experiment. This experiment will take data at the Paul Scherrer Institut where continuous muon beams are delivered at a rate of about 10^8 muons per second. On the same time scale, accelerator upgrades are expected in various facilities, making it feasible to have continuous beams with an intensity of 10^9 or even 10^10 muons per second. We investigate the experimental limiting factors that will define the ultimate performances, and hence the sensitivity, in the search for mu into e gamma with a continuous beam at these extremely high rates. We then consider some conceptual detector designs and evaluate the corresponding sensitivity as a function of the beam intensity.
△ Less
Submitted 17 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Single-hit resolution measurement with MEG II drift chamber prototypes
Authors:
A. M. Baldini,
E. Baracchini,
G. Cavoto,
M. Cascella,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
S. Dussoni,
L. Galli,
F. Grancagnolo,
M. Grassi,
V. Martinelli,
D. Nicolò,
M. Panareo,
A. Pepino,
G. Piredda,
F. Renga,
E. Ripiccini,
G. Signorelli,
G. F. Tassielli,
F. Tenchini,
M. Venturini,
C. Voena
Abstract:
Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles kee** the material budget in the sensitive volume to a minimum. The drawback of this solution is the worsening of the spatial resolution due to primary ionisation fluctuations, which is a limiting factor for high granularity drift chambers like the MEG II tracker. We report on the me…
▽ More
Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles kee** the material budget in the sensitive volume to a minimum. The drawback of this solution is the worsening of the spatial resolution due to primary ionisation fluctuations, which is a limiting factor for high granularity drift chambers like the MEG II tracker. We report on the measurements performed on three different prototypes of the MEG II drift chamber aimed at determining the achievable single-hit resolution. The prototypes were operated with helium/isobutane gas mixtures and exposed to cosmic rays, electron beams and radioactive sources. Direct measurements of the single hit resolution performed with an external tracker returned a value of 110 $μ$m, consistent with the values obtained with indirect measurements performed with the other prototypes.
△ Less
Submitted 25 May, 2016;
originally announced May 2016.
-
Muon polarization in the MEG experiment: predictions and measurements
Authors:
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. De Bari,
M. De Gerone,
A. DÓnofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama,
M. Hildebrandt
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stop** target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at…
▽ More
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stop** target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stop** target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.
△ Less
Submitted 28 April, 2016; v1 submitted 15 October, 2015;
originally announced October 2015.
-
Study of the single cluster response of a helium-isobutane drift chamber prototype using 8 keV X-rays
Authors:
G. Cavoto,
S. Dabagov,
D. Hampai,
G. Piredda,
F. Renga,
E. Ripiccini,
C. Voena
Abstract:
The identification of single clusters in the electronic signals produced by ionizing particles within a drift chamber is expected to significantly improve the performances of this kind of detectors in terms of particle identification capabilities and space resolution. In order to develop refined cluster recognition algorithms, it is essential to measure the response of the chamber and its electron…
▽ More
The identification of single clusters in the electronic signals produced by ionizing particles within a drift chamber is expected to significantly improve the performances of this kind of detectors in terms of particle identification capabilities and space resolution. In order to develop refined cluster recognition algorithms, it is essential to measure the response of the chamber and its electronics to single ionization clusters. This can be done by irradiating the chamber with X-rays. We report here on the studies performed on a drift chamber prototype for the MEG-II experiment at the X-ray facility of the INFN Frascati's National Laboratories "XLab Frascati". The prototype is operated with a helium-isobutane mixture and instrumented with high bandwidth custom pre-amplifiers. The results of this study have been used to develop an innovative method for cluster recognition, based on the Wiener filter technique. As a side measurement, we also performed a study of the gas gain in a configuration which is similar to that of the MEG-II experiment.
△ Less
Submitted 31 October, 2014;
originally announced October 2014.
-
Measurement of the radiative decay of polarized muons in the MEG experiment
Authors:
MEG Collaboration,
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama
, et al. (46 additional authors not shown)
Abstract:
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV…
▽ More
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.
△ Less
Submitted 7 March, 2016; v1 submitted 11 December, 2013;
originally announced December 2013.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
The MEG detector for $μ+\to e+γ$ decay search
Authors:
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
M. Corbo,
N. Curalli,
A. De Bari,
M. De Gerone,
L. Del Frate,
S. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
S. Galeotti,
G. Gallucci,
F. Gatti,
B. Golden
, et al. (51 additional authors not shown)
Abstract:
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and…
▽ More
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.
△ Less
Submitted 10 April, 2013; v1 submitted 10 March, 2013;
originally announced March 2013.
-
New constraint on the existence of the mu+-> e+ gamma decay
Authors:
MEG Collaboration,
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
A. de Bari,
M. De Gerone,
T. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
G. Gallucci,
F. Gatti,
B. Golden,
M. Grassi,
A. Graziosi,
D. N. Grigoriev
, et al. (49 additional authors not shown)
Abstract:
The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% conf…
▽ More
The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.
△ Less
Submitted 23 April, 2013; v1 submitted 4 March, 2013;
originally announced March 2013.
-
MEG Upgrade Proposal
Authors:
A. M. Baldini,
F. Cei,
C. Cerri,
S. Dussoni,
L. Galli,
M. Grassi,
D. Nicolò,
F. Raffaelli,
F. Sergiampietri,
G. Signorelli,
F. Tenchini,
D. Bagliani,
M. De Gerone,
F. Gatti,
E. Baracchini,
Y. Fujii,
T. Iwamoto,
D. Kaneko,
T. Mori,
M. Nishimura,
W. Ootani,
R. Sawada,
Y. Uchiyama,
G. Boca,
P. W. Cattaneo
, et al. (43 additional authors not shown)
Abstract:
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to ena…
▽ More
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stop** target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.
△ Less
Submitted 4 February, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.